Wrong decoding of INNR Remote ( 0x8085 doesn't report the reallity ) #194

Closed
pipiche38 opened this issue May 3, 2019 · 4 comments

Comments

@pipiche38
Copy link

commented May 3, 2019

It seems that there is some descrapancy in the way the Zigate is decoding and providing information to the 0x8085 message with the INNR RC110 remote controller

the Left/Right button are always providing the same infos, while when sniffing the messages with Ubiqua we see the right things

With Ubiqua, we see
Level Control: Move Up , Move Down, Stop

with Zigate, we see only Release Down, Stop

@pipiche38

This comment has been minimized.

Copy link
Author

commented May 3, 2019

Capture-move-down

@pipiche38

This comment has been minimized.

Copy link
Author

commented May 3, 2019

Capture-move-up

@fairecasoimeme

This comment has been minimized.

Copy link
Owner

commented May 4, 2019

Normally fixed in v3.1a

@pipiche38

This comment has been minimized.

Copy link
Author

commented Jul 8, 2019

Thanks , it works !

@pipiche38 pipiche38 closed this Jul 8, 2019

@fairecasoimeme fairecasoimeme referenced this issue Jul 12, 2019

Merged

V3.1a #209

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment