From 1d6994d49c6df972d3357620941a2882c11ece2a Mon Sep 17 00:00:00 2001 From: Trevor Pering Date: Sat, 10 Dec 2022 12:42:11 -0800 Subject: [PATCH] Updating writeback sequence.md --- docs/specs/sequences/generated.md | 19 ------------------- .../sequences/writeback_failure/sequence.md | 7 ------- .../sequences/writeback_invalid/sequence.md | 7 ------- .../sequences/writeback_success/sequence.md | 5 ----- 4 files changed, 38 deletions(-) diff --git a/docs/specs/sequences/generated.md b/docs/specs/sequences/generated.md index dff39335df..c5d55d8676 100644 --- a/docs/specs/sequences/generated.md +++ b/docs/specs/sequences/generated.md @@ -177,13 +177,6 @@ Restart and connect to same endpoint and expect it returns. ## writeback_failure -1. Update config before point filter_alarm_pressure_status to have value_state default (null): - * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_alarm_pressure_status to have value_state default (null) 1. Update config before point filter_alarm_pressure_status to have value_state failure: * Add `pointset.points.filter_alarm_pressure_status.set_value` = `false` @@ -191,13 +184,6 @@ Restart and connect to same endpoint and expect it returns. ## writeback_invalid -1. Update config before point filter_differential_pressure_sensor to have value_state default (null): - * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_differential_pressure_sensor to have value_state default (null) 1. Update config before point filter_differential_pressure_sensor to have value_state invalid: * Add `pointset.points.filter_differential_pressure_sensor.set_value` = `15` @@ -207,11 +193,6 @@ Restart and connect to same endpoint and expect it returns. 1. Update config before point filter_differential_pressure_setpoint to have value_state default (null): * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_differential_pressure_setpoint to have value_state default (null) 1. Update config before point filter_differential_pressure_setpoint to have value_state applied: * Add `pointset.points.filter_differential_pressure_setpoint.set_value` = `60` diff --git a/validator/sequences/writeback_failure/sequence.md b/validator/sequences/writeback_failure/sequence.md index b9403c23d9..b244f3a15b 100644 --- a/validator/sequences/writeback_failure/sequence.md +++ b/validator/sequences/writeback_failure/sequence.md @@ -1,13 +1,6 @@ ## writeback_failure -1. Update config before point filter_alarm_pressure_status to have value_state default (null): - * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_alarm_pressure_status to have value_state default (null) 1. Update config before point filter_alarm_pressure_status to have value_state failure: * Add `pointset.points.filter_alarm_pressure_status.set_value` = `false` diff --git a/validator/sequences/writeback_invalid/sequence.md b/validator/sequences/writeback_invalid/sequence.md index 84d64e1433..d9ebcfe8cc 100644 --- a/validator/sequences/writeback_invalid/sequence.md +++ b/validator/sequences/writeback_invalid/sequence.md @@ -1,13 +1,6 @@ ## writeback_invalid -1. Update config before point filter_differential_pressure_sensor to have value_state default (null): - * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_differential_pressure_sensor to have value_state default (null) 1. Update config before point filter_differential_pressure_sensor to have value_state invalid: * Add `pointset.points.filter_differential_pressure_sensor.set_value` = `15` diff --git a/validator/sequences/writeback_success/sequence.md b/validator/sequences/writeback_success/sequence.md index 0fb493e996..dc3e8bdcc0 100644 --- a/validator/sequences/writeback_success/sequence.md +++ b/validator/sequences/writeback_success/sequence.md @@ -3,11 +3,6 @@ 1. Update config before point filter_differential_pressure_setpoint to have value_state default (null): * Remove `pointset.points.filter_differential_pressure_setpoint.set_value` - * Remove `pointset.points.filter_differential_pressure_setpoint.units` - * Remove `pointset.points.filter_alarm_pressure_status.ref` - * Remove `pointset.points.filter_alarm_pressure_status.units` - * Remove `pointset.points.filter_differential_pressure_sensor.ref` - * Remove `pointset.points.filter_differential_pressure_sensor.units` 1. Wait for point filter_differential_pressure_setpoint to have value_state default (null) 1. Update config before point filter_differential_pressure_setpoint to have value_state applied: * Add `pointset.points.filter_differential_pressure_setpoint.set_value` = `60`