time: decide unit using largest value #6714

Merged
merged 1 commit into from Mar 6, 2020
Merged

time: decide unit using largest value #6714

merged 1 commit into from Mar 6, 2020

Conversation

afq984
Copy link
Contributor

@afq984 afq984 commented Mar 5, 2020

Using a unit based on (usr + sys) / 2 could cause one of them to overflow the %6.2F format and mess up alignment. This PR changes it to max(usr, sys).

This PR changes this:

> time sleep 0

________________________________________________________
Executed in    1.62 millis    fish           external 
   usr time  1622.00 micros  409.00 micros  1213.00 micros 
   sys time   50.00 micros   50.00 micros    0.00 micros

to this:

> time sleep 0

________________________________________________________
Executed in    1.90 millis    fish           external 
   usr time    1.43 millis    0.00 micros    1.43 millis 
   sys time    0.52 millis  522.00 micros    0.00 millis

@faho faho added this to the fish 3.2.0 milestone Mar 6, 2020
@faho faho merged commit f0d42ea into fish-shell:master Mar 6, 2020
@faho
Copy link
Member

faho commented Mar 6, 2020

Yeah, that's better! Thanks, merged!