[1.3.12rc1] Weird "M112 sent" message in log on connection error #3282

Closed
foosel opened this issue Sep 23, 2019 · 1 comment

Comments

@foosel
Copy link
Owner

commented Sep 23, 2019

Problem

See #3268 (comment)

Connecting to: /dev/ttyUSB0
Changing monitoring state from "Offline" to "Error: Connection error, see Terminal tab"
Closing serial port due to emergency stop M112.       <-- this doesn't belong
Unexpected error while connecting to serial port: /dev/ttyUSB0 SerialException: '[Errno 11] Could not exclusively lock port /dev/ttyUSB0: [Errno 11] Resource temporarily unavailable' @ comm.py:_openSerial:2661 (hook default)

Solution

Don't trigger M112 routine on connection error.

Already fixed in commit b9665a8 for 1.3.12rc3

@foosel

This comment has been minimized.

Copy link
Owner Author

commented Sep 23, 2019

1.3.12rc3 is out