runtime: frequent failures with sys: trap on plan9/386 and plan9/amd64 #50137

Open
bcmills opened this issue Dec 13, 2021 · 28 comments
Open

runtime: frequent failures with sys: trap on plan9/386 and plan9/amd64 #50137

bcmills opened this issue Dec 13, 2021 · 28 comments
Labels
compiler/runtime Issues related to the Go compiler and/or runtime. NeedsInvestigation Someone must examine and confirm this is a valid issue and not a duplicate of an existing one. OS-Plan9
Milestone

Comments

@bcmills
Copy link
Member

bcmills commented Dec 13, 2021

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
# internal/poll [io.test]
compile 11275: suicide: sys: trap: fault write addr=0x0 pc=0x00040481
FAIL	io [build failed]

These occur in lots of different binaries, and have occurred (but much less frequently) on plan9-arm.
@0intro, could you investigate? This appears to be one of the more frequent failure modes on the plan9-386-0intro builder, and since it appears to affect all Go binaries we cannot easily work around it by skipping one or more tests.

greplogs --dashboard -md -l -e 'suicide: sys: trap: fault'

2021-12-13T18:41:35-083ef54/plan9-386-0intro
2021-12-09T19:01:08-8ff254e/plan9-386-0intro
2021-12-09T16:59:48-307d7c6/plan9-386-0intro
2021-12-07T20:14:56-d3358c1-b37a539/plan9-386-0intro
2021-11-29T00:58:50-1ea4d3b/plan9-386-0intro
2021-11-26T13:18:11-7703804/plan9-386-0intro
2021-11-24T20:54:12-696515e/plan9-386-0intro
2021-11-17T19:51:32-9a33945/plan9-386-0intro
2021-11-08T14:49:56-ab31dbc/plan9-386-0intro
2021-11-06T19:41:14-cfb3dc7/plan9-386-0intro
2021-11-06T16:43:43-3544082/plan9-386-0intro
2021-11-05T22:57:08-09e8de7/plan9-386-0intro
2021-11-05T22:54:47-ba79c1e/plan9-386-0intro
2021-11-05T22:53:55-3b7e376/plan9-386-0intro
2021-11-05T22:28:32-feb024f/plan9-386-0intro
2021-11-05T22:27:21-8f923a4/plan9-386-0intro
2021-11-05T22:03:24-035963c/plan9-386-0intro
2021-11-05T22:00:16-755ede0/plan9-386-0intro
2021-11-05T21:48:25-6b223e8/plan9-386-0intro
2021-11-05T21:28:34-90462df/plan9-386-0intro
2021-09-07T19:39:04-d92101f/plan9-arm
2021-08-17T02:50:08-29ec74f/plan9-386-0intro
2021-08-15T19:56:18-98d530a-717894c/plan9-386-0intro
2021-08-15T19:56:18-717894c/plan9-386-0intro
2021-05-14T07:53:46-c925e15/plan9-386-0intro
2021-05-10T19:19:34-dc50683/plan9-386-0intro
2021-05-10T15:47:41-e18a8b4/plan9-386-0intro
2021-05-06T17:09:23-51ff3a6/plan9-386-0intro
2021-05-06T16:00:55-6c591f7/plan9-386-0intro
2021-04-29T13:24:00-858fdbe-eb3fe28/plan9-arm
2021-04-28T20:36:50-fa6ed6e/plan9-386-0intro
2021-04-27T21:44:16-645cb62/plan9-386-0intro
2021-04-27T19:53:45-d0768c9-b9dfaf7/plan9-386-0intro
2021-04-21T16:26:01-b8a359d/plan9-386-0intro
2021-04-21T15:57:05-f9e2dbb/plan9-386-0intro
2021-04-16T20:18:11-4fb74e0/plan9-386-0intro
2021-04-14T21:00:20-23f8c20/plan9-386-0intro
2021-03-25T14:46:50-4d66d77/plan9-386-0intro
2021-03-25T04:06:37-c69515c/plan9-386-0intro
2021-03-13T11:26:35-83e79c7/plan9-386-0intro
2021-03-13T00:32:00-7b47f9a/plan9-386-0intro
2021-03-04T16:21:10-3778f8e/plan9-386-0intro
2021-03-04T03:30:55-4532467/plan9-386-0intro
2021-02-19T19:28:53-06b86e9/plan9-386-0intro
2021-02-11T01:10:35-930c2c9/plan9-386-0intro
2021-02-03T15:04:02-e491c6e/plan9-386-0intro
2021-01-25T23:52:43-a51921f/plan9-386-0intro
2020-12-14T22:04:37-278b9a8/plan9-386-0intro
2020-12-11T22:02:02-1430552/plan9-arm
2020-11-30T17:21:22-294c214/plan9-arm
2020-11-27T23:29:38-cb84d83/plan9-386-0intro
2020-11-27T22:28:11-0252cfd/plan9-386-0intro
2020-11-25T19:46:00-4481ad6/plan9-386-0intro
2020-11-25T19:21:55-ef603be/plan9-386-0intro
2020-11-10T18:42:47-9e8e0b3-8f2db14/plan9-arm
2020-11-06T10:45:31-854e892/plan9-amd64-9front
2020-11-02T16:14:49-05e6d28/plan9-arm
2020-10-21T13:19:35-54c0237/plan9-386-0intro
2020-10-21T09:34:39-9848e93/plan9-386-0intro
2020-10-01T16:43:20-ad8447b/plan9-386-0intro
2020-09-28T18:13:48-a424f6e/plan9-386-0intro
2020-09-25T19:10:05-8266570/plan9-386-0intro
2020-09-11T15:07:26-ffd95aa/plan9-386-0intro
2020-08-26T21:11:51-bf869c6/plan9-386-0intro
2020-08-16T13:55:00-cf9b4f6/plan9-386-0intro
2020-08-02T00:04:25-f923374/plan9-386-0intro
2020-06-08T21:36:04-2cd2ff6/plan9-386-0intro
2020-06-02T20:44:05-c082c1f/plan9-arm
2020-05-01T18:47:23-8be365f/plan9-386-0intro
2020-04-15T16:37:53-555d28b-813f8ea/plan9-arm
2020-04-11T02:04:15-59c9f1b-06314b6/plan9-arm
2020-04-07T21:51:03-0a82000/plan9-386-0intro
2020-04-07T15:03:09-553a862/plan9-386-0intro
2020-04-06T18:06:41-e3b113b-74d6de0/plan9-arm
2020-03-30T03:39:49-0b7c202/plan9-386-0intro
2020-03-27T17:14:16-e5e73c1-0cc1290/plan9-arm
2020-03-27T15:27:59-827a7a9/plan9-386-0intro
2020-03-27T14:49:08-dbd22c7/plan9-386-0intro
2020-03-26T19:07:15-437bd90/plan9-386-0intro
2020-03-26T17:48:20-918d4d4/plan9-386-0intro
2020-03-25T13:10:07-16cfab8/plan9-386-0intro
2020-03-25T04:06:34-6b6414c/plan9-386-0intro
2020-03-23T03:31:16-328b4cd-ab2cc45/plan9-arm
2020-03-23T03:31:16-118fecf-ab2cc45/plan9-arm
2020-03-21T06:00:19-d467f3b/plan9-386-0intro
2020-03-20T00:49:34-63522db-d55e0c1/plan9-arm
2020-03-18T16:00:44-5766fd3-0c0e8f2/plan9-arm
2020-03-17T20:48:23-adf48cb-0eeec4f/plan9-arm
2020-03-16T22:31:39-adf48cb-2fbca94/plan9-arm
2020-03-15T08:14:24-dc32553/plan9-386-0intro
2020-03-15T06:17:36-2b920cb/plan9-386-0intro
2020-03-14T04:12:41-5c8b2ff-70dc28f/plan9-arm
2020-03-13T22:25:52-e8ecda8/plan9-386-0intro
2020-03-11T22:32:55-67d93cf/plan9-386-0intro
2020-03-10T19:41:44-78000ba-5db3c8f/plan9-arm
2020-03-10T00:47:00-a79ac2b/plan9-386-0intro
2020-03-06T14:41:22-2b0f481/plan9-arm
2020-03-03T18:42:30-7b0b6c2/plan9-arm
2020-03-03T04:56:11-5b15941/plan9-386-0intro
2020-03-01T21:02:40-e44cda3/plan9-386-0intro
2020-02-26T21:54:09-8bdd24d/plan9-386-0intro
2020-02-26T14:31:35-26aadfa/plan9-386-0intro
2020-02-17T10:30:03-88e564e/plan9-386-0intro
2020-02-05T00:06:37-f770366/plan9-386-0intro
2020-01-30T02:33:27-0d34f5f/plan9-386-0intro
2020-01-29T02:43:35-212c0bf/plan9-386-0intro
2020-01-28T22:08:43-e7f9e17/plan9-386-0intro
2020-01-23T19:11:41-39ea3d0/plan9-386-0intro
2020-01-23T18:03:09-8689ea6/plan9-386-0intro
2020-01-23T00:22:41-9f1d55c/plan9-386-0intro
2020-01-22T00:45:41-71bbffb/plan9-386-0intro
2020-01-18T14:41:40-98d2717/plan9-386-0intro
2020-01-13T23:35:18-563287a/plan9-386-0intro
2020-01-03T19:04:06-4ffd1a0/plan9-386-0intro
2019-12-27T03:36:24-2d6f8cc/plan9-386-0intro
2019-12-24T16:07:08-2e320a2/plan9-386-0intro
2019-12-11T22:01:13-a15b5d3/plan9-386-0intro
2019-12-09T02:02:17-daaab44/plan9-386-0intro
2019-11-22T19:01:42-c931f1b/plan9-386-0intro
2019-11-19T06:08:56-1046a9c/plan9-386-0intro
2019-11-18T05:26:46-f9c8255-2bde3c1/plan9-386-0intro
2019-11-16T02:06:39-a1ab85d-c20b71e/plan9-386-0intro
2019-11-15T18:52:11-e1fa960/plan9-386-0intro
2019-11-14T01:57:00-3f21c23/plan9-386-0intro
2019-11-13T23:05:47-608b94b/plan9-386-0intro
2019-11-13T21:24:35-718f553/plan9-386-0intro
2019-11-12T21:02:24-00e14af/plan9-386-0intro
2019-11-12T17:14:12-07513d2/plan9-386-0intro
2019-11-09T19:25:46-6e11195/plan9-386-0intro
2019-11-08T20:05:25-7a5e0fe/plan9-386-0intro
2019-11-08T19:28:49-f6ff806/plan9-386-0intro
2019-11-08T18:25:40-aff3aaa/plan9-386-0intro
2019-11-08T16:20:17-4208dbe/plan9-386-0intro
2019-11-04T18:51:13-bf7e55b/plan9-arm
2019-11-04T15:18:34-d3660e8/plan9-386-0intro
2019-10-22T21:23:03-7d891d5/plan9-386-0intro
2019-09-18T20:51:31-e13dd94/plan9-arm
2019-09-10T23:01:30-b970487/plan9-386-0intro
2019-08-31T14:56:29-c96d794/plan9-amd64-9front
2019-06-19T19:37:19-0ab1cc3/plan9-386-0intro
2018-12-18T12:02:45-42b3178-c52beb1/plan9-386
2018-10-12T23:17:42-49bb7ce-b4150f7/plan9-386
2018-10-05T20:30:11-e363607-3d19d95/plan9-386
2018-08-03T03:58:03-56440b8-4cc09cd/plan9-386
2018-07-24T23:54:08-3673e40-5f5402b/plan9-386
2018-07-13T03:53:00-a49355c-8a33045/plan9-386
2018-07-10T03:00:05-292b43b-5a8b652/plan9-386
2018-06-29T17:44:10-3d766fa-cbce223/plan9-386
2018-06-26T23:56:13-af66def-f040e43/plan9-386
2018-06-25T18:17:49-af66def-4f172e7/plan9-386
2018-06-18T23:20:57-af66def-c993002/plan9-386
2018-06-09T07:34:45-1e49130-d67db88/plan9-386
2018-06-08T02:11:51-0d7a669-1425412/plan9-386
2018-06-01T15:24:42-5ba7f63-3d6e4ec/plan9-386
2018-05-31T22:48:13-5ba7f63-a7e0a92/plan9-386
2018-04-25T17:08:07-b0697ec-f2df0ec/plan9-386
2018-03-13T16:09:57-182114d-518e6f0/plan9-386
2018-03-10T21:20:50-ea1fc7e-c15b7b2/plan9-386
2018-03-09T01:58:41-c7dcf10-6b5a0b5/plan9-386

@bcmills bcmills added this to the Backlog milestone Dec 13, 2021
@bcmills bcmills added the NeedsInvestigation Someone must examine and confirm this is a valid issue and not a duplicate of an existing one. label Dec 13, 2021
@bcmills
Copy link
Member Author

bcmills commented Jan 6, 2022

This also appears to manifest as fatal error: fault:

greplogs --dashboard -md -l -e 'fatal error: fault\n\[signal sys: trap: fault'

2022-01-06T15:00:16-da7891f/plan9-386-0intro
2022-01-02T14:27:43-ee1ca4f-c886143/plan9-386-0intro
2021-12-17T00:14:53-18b340f-2e6e9df/plan9-arm
2021-12-15T00:33:55-27fc764-9d0ca26/plan9-386-0intro
2021-12-14T20:25:03-27fc764-0f05ed3/plan9-386-0intro
2021-12-14T19:53:20-4570a08-d407a8c/plan9-386-0intro
2021-12-13T06:35:06-4570a08-9bfe09d/plan9-386-0intro
2021-12-04T17:16:07-18b340f-3396878/plan9-arm
2021-11-19T21:41:33-ba9f0f6/plan9-386-0intro
2021-11-18T02:10:22-e3b48af/plan9-386-0intro
2021-11-04T15:43:59-6ba68a0/plan9-386-0intro
2021-10-26T22:05:53-80be4a4/plan9-386-0intro
2021-10-15T20:29:36-a17b2e8/plan9-386-0intro
2021-10-09T23:29:26-b99abf3/plan9-386-0intro
2021-10-08T18:07:25-d480b5c/plan9-386-0intro
2021-10-08T17:32:31-d7ba1d2/plan9-386-0intro
2021-10-07T14:37:36-375a1fb/plan9-arm
2021-09-02T17:00:30-acc2957/plan9-386-0intro
2021-06-24T00:39:41-d824a74-73496e0/plan9-386-0intro
2021-06-10T20:20:58-770f1de/plan9-386-0intro
2021-05-07T17:43:31-b44c78b/plan9-386-0intro
2021-05-07T03:55:29-f5423ea/plan9-386-0intro
2021-05-04T20:18:55-10a082a/plan9-386-0intro
2021-04-21T21:14:04-54af9fd/plan9-386-0intro
2021-03-19T17:08:02-836dbdb/plan9-386-0intro
2021-03-11T20:01:00-4dd9c7c/plan9-386-0intro
2021-03-11T19:11:46-5ea612d-43d5f21/plan9-386-0intro
2021-03-11T18:25:30-bbf7979/plan9-386-0intro
2021-02-19T23:22:33-26713b5/plan9-386-0intro
2021-02-01T05:14:58-6ac91e4/plan9-386-0intro
2021-01-28T16:02:12-725a642/plan9-386-0intro
2021-01-27T21:11:22-00f2ff5/plan9-386-0intro
2021-01-27T20:44:24-a5a5e2c/plan9-386-0intro
2021-01-27T12:18:00-cd176b3/plan9-386-0intro
2021-01-26T00:30:18-1d5e146/plan9-386-0intro
2021-01-25T16:08:46-54b251f/plan9-386-0intro
2021-01-25T12:30:58-044f937/plan9-386-0intro
2021-01-19T12:48:38-61debff/plan9-386-0intro
2021-01-08T05:00:06-304f769/plan9-386-0intro
2021-01-08T03:43:44-ae97717/plan9-386-0intro
2021-01-07T19:31:03-fa90aac/plan9-386-0intro
2020-12-23T14:16:32-98a7303/plan9-386-0intro
2020-12-17T20:25:45-8fcf318/plan9-386-0intro
2020-12-14T17:37:52-be10af7/plan9-386-0intro
2020-11-09T20:02:56-5e18135/plan9-386-0intro
2020-11-09T14:17:30-f858c22/plan9-386-0intro
2020-11-09T13:12:41-2231243/plan9-386-0intro
2020-10-23T20:38:27-75032ad/plan9-386-0intro
2020-10-06T22:56:00-f8e5540/plan9-386-0intro
2020-09-28T06:38:58-e572218/plan9-386-0intro
2020-09-28T06:01:37-8ab020a/plan9-386-0intro
2020-09-24T22:45:05-ea106cc/plan9-386-0intro
2020-09-24T21:51:51-f765dcb/plan9-386-0intro
2020-09-24T16:22:34-0f55d37/plan9-386-0intro
2020-09-24T15:48:24-8e8bfb6/plan9-386-0intro
2020-09-24T13:29:01-9e073b5/plan9-386-0intro
2020-09-23T18:12:59-a413908/plan9-386-0intro
2020-09-18T07:56:50-06f7e65/plan9-386-0intro
2020-09-18T04:16:08-234e23d/plan9-386-0intro
2020-09-17T23:22:34-982ac06/plan9-386-0intro
2020-08-24T19:20:59-bb99874/plan9-386-0intro
2020-07-08T19:50:20-9699086/plan9-386-0intro
2020-07-06T21:47:57-6a167c7/plan9-386-0intro
2020-07-01T09:07:18-84152d5/plan9-386-0intro
2020-06-29T21:33:02-2ca0f5a/plan9-386-0intro
2020-06-29T08:06:23-a980e8a/plan9-386-0intro
2020-06-18T01:14:19-d872bbc/plan9-386-0intro
2020-06-18T01:12:21-84baf41/plan9-386-0intro
2020-06-17T00:18:55-e25aa4f/plan9-386-0intro
2020-06-16T21:19:08-9ca2474/plan9-386-0intro
2020-06-16T19:29:32-844bf11/plan9-386-0intro
2020-06-15T18:03:08-8c8045f/plan9-386-0intro
2020-06-11T22:17:59-7495a42/plan9-386-0intro
2020-06-10T20:58:11-ec177e4/plan9-386-0intro
2020-06-08T12:11:01-5c6b2b1/plan9-386-0intro
2020-06-03T22:07:42-279210d-429d2c5/plan9-386-0intro
2020-06-03T19:07:55-9984ef8/plan9-386-0intro
2020-06-03T18:03:41-09e791f/plan9-386-0intro
2020-06-03T14:51:34-5aaeda1/plan9-386-0intro
2020-06-02T21:19:07-ee776b4/plan9-386-0intro
2020-06-02T20:59:16-1193958/plan9-386-0intro
2020-06-01T21:59:51-612da6b/plan9-386-0intro
2020-06-01T15:54:29-eecc628/plan9-386-0intro
2020-05-31T18:35:04-0452f94/plan9-386-0intro
2020-05-31T09:48:08-7dbbb5b/plan9-386-0intro
2020-05-31T00:55:05-8da7862/plan9-386-0intro
2020-05-31T00:38:00-fc40beb/plan9-386-0intro
2020-05-30T03:20:54-1ed57c1/plan9-386-0intro
2020-05-28T21:41:10-86ed095/plan9-386-0intro
2020-05-28T19:51:59-2711127/plan9-386-0intro
2020-05-27T19:54:12-0d20a49/plan9-386-0intro
2020-05-27T15:26:40-902d8de/plan9-386-0intro
2020-05-27T13:37:56-c0e8e40/plan9-386-0intro
2020-05-23T06:47:06-b68fa57/plan9-386-0intro
2020-05-21T21:17:48-9f4aeb3/plan9-386-0intro
2020-05-21T14:45:26-fed33d7/plan9-386-0intro
2020-05-19T19:55:14-1361738/plan9-386-0intro
2020-05-19T15:34:47-d87ec0c-8fa468d/plan9-386-0intro
2020-05-19T15:34:47-8fa468d/plan9-386-0intro
2020-05-19T11:38:04-d87ec0c-c88f698/plan9-386-0intro
2020-05-19T04:10:43-a91f071-c88f698/plan9-386-0intro
2020-05-18T23:09:31-a91f071-185c3d4/plan9-386-0intro
2020-05-18T23:09:31-185c3d4/plan9-386-0intro
2020-05-18T23:04:48-b0bc18d/plan9-386-0intro
2020-05-18T13:11:11-afd477f/plan9-386-0intro
2020-05-18T13:11:11-a91f071-afd477f/plan9-386-0intro
2020-05-18T09:13:38-bb59a13/plan9-386-0intro
2020-05-15T16:15:25-a91f071-2b70ffe/plan9-386-0intro
2020-05-14T21:41:46-881d540/plan9-386-0intro
2020-05-14T18:58:17-f474e9e/plan9-386-0intro
2020-05-13T22:15:39-a91f071-a88c26e/plan9-386-0intro
2020-05-13T22:15:39-a88c26e/plan9-386-0intro
2020-05-13T18:57:01-a91f071-14bec27/plan9-386-0intro
2020-05-13T18:00:00-b819adf/plan9-386-0intro
2020-05-13T18:00:00-7e3656a-b819adf/plan9-386-0intro
2020-05-13T17:48:20-ee0d40c/plan9-386-0intro
2020-05-12T19:15:34-cb11c98/plan9-386-0intro
2020-05-12T15:01:56-a0698a6/plan9-386-0intro
2020-05-11T22:38:32-afb9336-8c1db77/plan9-386-0intro
2020-05-11T22:38:32-7e3656a-8c1db77/plan9-386-0intro
2020-05-11T22:26:51-910fee4/plan9-386-0intro
2020-05-11T16:23:52-7e3656a-2cb10d4/plan9-386-0intro
2020-05-08T21:21:40-7cfa7d6/plan9-386-0intro
2020-05-07T02:45:57-05e3ad3/plan9-386-0intro
2020-05-06T17:06:02-e538b7e/plan9-386-0intro
2020-04-28T17:42:24-0ddde4a/plan9-386-0intro
2020-04-24T23:56:54-b3e8a00/plan9-386-0intro
2020-04-02T15:54:17-aa4d92b/plan9-386-0intro
2020-03-25T15:37:25-2568d32/plan9-386-0intro
2020-03-24T19:06:22-e0deacd/plan9-386-0intro
2020-03-22T00:10:27-36b815e/plan9-386-0intro
2020-03-20T08:42:30-9d468f4/plan9-386-0intro
2020-03-20T00:33:16-a3a9901/plan9-386-0intro
2020-03-19T00:08:40-b3b174f/plan9-386-0intro
2020-03-17T17:10:51-14d20dc/plan9-386-0intro
2020-03-17T01:24:30-0e44c69/plan9-386-0intro
2020-03-16T20:59:27-ff1eb42/plan9-386-0intro
2020-03-04T23:08:10-17e6252/plan9-386-0intro
2020-03-02T08:32:38-b79acf9/plan9-386-0intro
2020-03-01T22:26:33-529988d/plan9-386-0intro
2020-03-01T02:18:27-c1abd5a/plan9-386-0intro
2020-02-28T19:09:53-5a61de3/plan9-386-0intro
2020-02-28T19:05:54-d11e1f9/plan9-386-0intro
2020-02-28T13:21:44-a3fc77a/plan9-386-0intro
2020-02-27T23:19:45-7340e5a/plan9-386-0intro
2020-02-26T17:58:41-a1103dc/plan9-386-0intro
2020-02-26T08:43:57-42b93b7/plan9-386-0intro
2020-02-25T18:40:19-2783249/plan9-386-0intro
2020-02-20T22:34:08-8484d40/plan9-386-0intro
2020-01-23T20:44:44-8453844/plan9-386-0intro
2020-01-23T16:52:00-64378c2/plan9-386-0intro
2020-01-22T18:10:42-895b7c8/plan9-386-0intro
2020-01-20T14:57:06-94506bc-df2999e/plan9-386-0intro
2020-01-19T14:04:09-8e0be05/plan9-386-0intro
2020-01-16T22:25:09-574c286/plan9-386-0intro
2020-01-15T22:02:44-f77e7ed/plan9-386-0intro
2020-01-15T18:49:52-5a3a5d3/plan9-386-0intro
2020-01-15T05:32:51-ee55dd6/plan9-386-0intro
2020-01-14T17:13:34-86b9105-71154e0/plan9-386-0intro
2020-01-14T15:51:35-0c65531/plan9-386-0intro
2020-01-13T21:49:46-9ead772/plan9-386-0intro
2020-01-13T07:00:18-52c4488/plan9-386-0intro
2020-01-10T21:04:43-ae0b735/plan9-386-0intro
2020-01-10T19:19:22-e6bbe96/plan9-386-0intro
2020-01-09T19:50:42-10bfe5b/plan9-386-0intro
2020-01-09T17:52:45-509592d/plan9-386-0intro
2020-01-09T17:28:58-957259b/plan9-386-0intro
2020-01-09T15:38:00-6dbcc8b/plan9-386-0intro
2020-01-08T18:43:55-2248fc6/plan9-386-0intro
2020-01-08T14:58:33-4b1b18d/plan9-386-0intro
2020-01-07T18:35:31-b8e2ffc/plan9-386-0intro
2020-01-07T18:00:57-249c85d/plan9-386-0intro
2020-01-07T17:52:37-c399afe/plan9-386-0intro
2020-01-07T16:24:34-bc91947/plan9-386-0intro
2020-01-06T18:12:55-822094f/plan9-386-0intro
2020-01-06T16:22:05-cf7a46c/plan9-386-0intro
2020-01-06T15:56:20-9d3d446/plan9-386-0intro
2020-01-06T15:47:54-2863969/plan9-386-0intro
2020-01-06T09:24:06-fc5eee3/plan9-386-0intro
2020-01-03T19:05:09-c57665f/plan9-386-0intro
2020-01-03T17:08:02-a7be8cc/plan9-386-0intro
2019-12-30T20:44:00-aa175a1/plan9-386-0intro
2019-12-19T17:22:29-a197c7b/plan9-386-0intro
2019-12-11T19:37:19-9d78e75/plan9-386-0intro
2019-12-11T01:10:28-a1a67e6/plan9-386-0intro
2019-12-11T00:32:53-9641acd/plan9-386-0intro
2019-12-10T18:30:47-ecde0bf/plan9-386-0intro
2019-12-07T15:57:30-e7e4b65-da4d585/plan9-386-0intro
2019-12-07T14:55:58-c8ca962-bff4ebb/plan9-386-0intro
2019-12-07T00:46:38-ecb187b-bff4ebb/plan9-386-0intro
2019-12-07T00:46:38-e7e4b65-bff4ebb/plan9-386-0intro
2019-12-07T00:46:38-c1d9249-bff4ebb/plan9-386-0intro
2019-12-07T00:46:38-bff4ebb/plan9-386-0intro
2019-12-07T00:46:38-788aebd-bff4ebb/plan9-386-0intro
2019-12-06T23:53:46-ecb187b-33d2076/plan9-386-0intro
2019-12-06T23:53:46-33d2076/plan9-386-0intro
2019-12-06T23:44:51-94ddb2d/plan9-386-0intro
2019-12-06T23:12:11-1ddd1de-df0ac45/plan9-386-0intro
2019-12-06T22:06:42-c1d9249-1de3131/plan9-386-0intro
2019-12-06T20:31:18-788aebd-1de3131/plan9-386-0intro
2019-12-06T20:31:18-1de3131/plan9-386-0intro
2019-12-06T19:49:21-b2a5893/plan9-386-0intro
2019-12-06T18:04:42-a6c8fac/plan9-386-0intro
2019-12-06T15:32:53-3765179-69614c0/plan9-386-0intro
2019-12-06T15:19:52-ecb187b-69614c0/plan9-386-0intro
2019-12-06T15:19:52-69614c0/plan9-386-0intro
2019-12-06T15:19:52-1ddd1de-69614c0/plan9-386-0intro
2019-12-06T10:30:17-1ddd1de-0915a19/plan9-386-0intro
2019-12-06T10:28:45-afd1edf-0915a19/plan9-386-0intro
2019-12-06T05:12:15-ce4227a-0915a19/plan9-386-0intro
2019-12-06T05:10:34-6ef7794/plan9-386-0intro
2019-12-06T03:52:48-ecb187b-b81e01d/plan9-386-0intro
2019-12-06T03:52:48-b81e01d/plan9-386-0intro
2019-12-03T04:15:58-386b1a4/plan9-386-0intro
2019-12-02T20:12:54-a18608a/plan9-386-0intro
2019-12-02T16:11:24-3edd1d8/plan9-386-0intro
2019-11-24T15:06:38-b81dd1c/plan9-386-0intro
2019-11-23T11:00:41-bd43791-6f7b96f/plan9-386-0intro
2019-11-23T09:35:22-c2e2296/plan9-386-0intro
2019-11-22T15:34:14-3922c00/plan9-386-0intro
2019-11-22T14:32:02-ea18a1c/plan9-386-0intro
2019-11-22T14:32:02-4b67af8-ea18a1c/plan9-386-0intro
2019-11-22T03:06:22-fc4aabc-0e02cfb/plan9-386-0intro
2019-11-21T22:20:17-4f8c1d8-94e9a5e/plan9-386-0intro
2019-11-11T22:40:24-49ac23a/plan9-386-0intro
2019-11-11T12:40:04-f07059d/plan9-386-0intro
2019-11-10T20:36:44-47bc240/plan9-386-0intro
2019-11-10T17:13:25-298be61/plan9-386-0intro
2019-11-10T04:23:22-e6fb39a/plan9-386-0intro
2019-11-09T22:14:01-78d4560/plan9-386-0intro
2019-11-08T17:56:35-a84ac18/plan9-386-0intro
2019-10-31T17:09:48-a9b37ae/plan9-386-0intro
2019-10-16T21:57:24-943df4f/plan9-386-0intro
2019-10-16T20:38:29-2718789/plan9-386-0intro
2019-10-14T21:00:36-19532d0/plan9-386-0intro
2019-10-12T08:01:10-e79c238/plan9-386-0intro
2019-10-11T18:31:46-0e3e46f/plan9-386-0intro
2019-10-11T18:09:33-2686e74/plan9-386-0intro
2019-10-08T10:45:48-cedb561/plan9-386-0intro
2019-10-03T20:31:11-2bf7a92/plan9-386-0intro
2019-09-24T16:15:36-904fdb3/plan9-386-0intro
2019-09-22T17:10:30-20f0bcb/plan9-386-0intro
2019-09-20T14:33:26-dfbc9c8/plan9-386-0intro
2019-09-20T12:41:45-3507551/plan9-386-0intro
2019-09-19T15:36:49-5d548f1/plan9-386-0intro
2019-09-19T01:54:17-b7e9c7a/plan9-386-0intro
2019-09-18T20:32:43-bcf6f9f/plan9-386-0intro
2019-09-13T09:04:48-98aa978/plan9-386-0intro
2019-09-11T12:26:35-0e015e2/plan9-386-0intro
2019-09-06T01:35:46-1406ece/plan9-386-0intro
2019-07-08T18:21:41-0fddd66/plan9-386-0intro

@bcmills bcmills changed the title runtime: frequent failures with "suicide: sys: trap: fault" on plan9-386-0intro runtime: frequent failures with "suicide: sys: trap: fault" or "signal sys: trap: fault" on plan9-386-0intro Jan 6, 2022
@bcmills bcmills changed the title runtime: frequent failures with "suicide: sys: trap: fault" or "signal sys: trap: fault" on plan9-386-0intro runtime: frequent failures with "sys: trap: fault" or "fatal error: fault" on plan9-386-0intro Jan 28, 2022
@bcmills
Copy link
Member Author

bcmills commented Apr 7, 2022

This is still a frequent failure mode on the plan9-386-0intro builder:

greplogs --dashboard -md -l -e 'fatal error: fault\n\[signal sys: trap: fault' --since=2022-01-07

2022-04-07T10:41:34-ae2d966-3a0cda4/plan9-386-0intro
2022-04-07T05:42:16-b92514a-870256e/plan9-386-0intro
2022-04-05T23:32:55-0bd8c7d-2de2f6d/plan9-386-0intro
2022-04-05T18:58:52-6242fa9-5a6a830/plan9-386-0intro
2022-04-05T18:01:26-9e16cc1/plan9-386-0intro
2022-04-04T21:43:42-605edab-cd33b40/plan9-386-0intro
2022-04-04T15:58:39-7d125fe-c8110c3/plan9-386-0intro
2022-04-03T23:48:16-153e30b-ba6df85/plan9-386-0intro
2022-04-03T21:26:39-6242fa9-3451844/plan9-386-0intro
2022-04-02T17:45:45-b92514a-01c83be/plan9-386-0intro
2022-03-31T21:17:08-434b2a5/plan9-386-0intro
2022-03-31T16:58:48-b76863e-3706584/plan9-386-0intro
2022-03-31T14:57:35-378221b/plan9-386-0intro
2022-03-31T14:51:17-2ea9376/plan9-386-0intro
2022-03-17T00:08:36-8d4da2c/plan9-386-0intro
2022-03-16T16:06:15-a3fcc75/plan9-386-0intro
2022-03-16T00:34:27-6e49c59/plan9-386-0intro
2022-03-15T18:37:49-db3045b/plan9-386-0intro
2022-03-15T17:29:54-4e26ab0/plan9-386-0intro
2022-03-15T15:21:54-b054c7d/plan9-386-0intro
2022-03-15T02:22:54-e475cf2/plan9-386-0intro
2022-03-15T00:19:35-41a82aa/plan9-386-0intro
2022-03-14T20:05:58-dff7c5f-41fe746/plan9-386-0intro
2022-03-14T11:03:14-198cae3-7900576/plan9-386-0intro
2022-03-11T00:42:08-9743e9b/plan9-386-0intro
2022-03-07T18:19:44-7dc6c5e/plan9-386-0intro
2022-03-04T21:06:05-bf97c99/plan9-386-0intro
2022-03-03T22:52:16-3ce7728-4f80943/plan9-386-0intro
2022-03-03T16:02:44-d3fe4e1/plan9-386-0intro
2022-03-03T14:42:03-09e0201-86371b0/plan9-386-0intro
2022-02-18T20:32:59-61b5c86/plan9-386-0intro
2022-02-10T15:23:05-452f24a/plan9-386-0intro
2022-02-01T20:55:43-a6a7c7a/plan9-arm
2022-01-26T19:33:44-da31bd3-8cfbb58/plan9-386-0intro
2022-01-12T19:47:40-f005df8/plan9-386-0intro

@gopherbot
Copy link

Change https://go.dev/cl/408698 mentions this issue: dashboard: add known issues for plan9-386, plan9-386-0intro, and plan9-amd64-0intro

gopherbot pushed a commit to golang/build that referenced this issue May 26, 2022
…9-amd64-0intro

For golang/go#52653.
Updates golang/go#29801.
Updates golang/go#49756.
Updates golang/go#50137.

Change-Id: Ided04da5c1e403c4a194c8c645c5179534a00907
Reviewed-on: https://go-review.googlesource.com/c/build/+/408698
TryBot-Result: Gopher Robot <gobot@golang.org>
Run-TryBot: Bryan Mills <bcmills@google.com>
Reviewed-by: Alex Rakoczy <alex@golang.org>
Auto-Submit: Bryan Mills <bcmills@google.com>
@gopherbot gopherbot added the compiler/runtime Issues related to the Go compiler and/or runtime. label Jul 7, 2022
@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|signal) sys: trap: fault`
2022-12-02 16:30 plan9-386-0intro go@d71b1c3d io.test [build] (log)
link 16879: suicide: sys: trap: fault write addr=0x766e652f pc=0x000060ad
2022-12-06 17:44 plan9-amd64-0intro tools@aee3994b go@dfd13ce5 x/tools/cmd/callgraph (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x4ea454]

goroutine 971 [running]:
golang.org/x/tools/go/packages.(*loader).loadRecursive(0x31b3a160?, 0x380e2420?)
	/tmp/workdir-gnot/gopath/src/golang.org/x/tools/go/packages/packages.go:838 +0x14
golang.org/x/tools/go/packages.(*loader).loadRecursive.func1.1(0x0?)
	/tmp/workdir-gnot/gopath/src/golang.org/x/tools/go/packages/packages.go:845 +0x2c
created by golang.org/x/tools/go/packages.(*loader).loadRecursive.func1
	/tmp/workdir-gnot/gopath/src/golang.org/x/tools/go/packages/packages.go:844 +0x85

watchflakes

@bcmills bcmills changed the title runtime: frequent failures with "sys: trap: fault" or "fatal error: fault" on plan9-386-0intro runtime: frequent failures with "sys: trap: fault" or "fatal error: fault" on plan9/386 and plan9/amd64 Dec 7, 2022
@bcmills bcmills changed the title runtime: frequent failures with "sys: trap: fault" or "fatal error: fault" on plan9/386 and plan9/amd64 runtime: frequent failures with sys: trap on plan9/386 and plan9/amd64 Dec 7, 2022
@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2022-12-06 20:08 plan9-386-0intro net@1e63c2f0 go@a3989632 x/net/idna.test [build] (log)
fatal error: sys: trap: general protection violation pc=0x006fa005
[signal sys: trap: code=0x0 addr=0x0 pc=0x6fa005]

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2022-12-06 18:24 plan9-arm text@ec5565b1 go@d03231d9 (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0xa pc=0x10f34]

goroutine 5266 [running]:
syscall.WaitProcess(0x703, 0x9e5c528)
	/boot/workdir/go/src/syscall/exec_plan9.go:593 +0xb4
os.(*Process).wait(0x9d954d0)
	/boot/workdir/go/src/os/exec_plan9.go:73 +0x40
os.(*Process).Wait(...)
	/boot/workdir/go/src/os/exec.go:132
os/exec.(*Cmd).Wait(0x9b63e00)
	/boot/workdir/go/src/os/exec/exec.go:890 +0x38
os/exec.(*Cmd).Run(0x9b63e00)
	/boot/workdir/go/src/os/exec/exec.go:590 +0x48
cmd/go/internal/work.(*Builder).runOut(0x9c91340, 0x9c489c0, {0x94fe4b0, 0x30}, {0x9943dfc, 0x1, 0x1}, {0x9943e1c, 0x4, 0x4})
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:2263 +0x608
cmd/go/internal/work.(*Builder).run(0x9c91340, 0x9c489c0, {0x94fe4b0, 0x30}, {0x958d7de, 0x1b}, {0x9943dfc, 0x1, 0x1}, {0x9943e1c, ...})
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:2172 +0x64
cmd/go/internal/work.(*Builder).vet(0x9c91340, {0x6e06b4, 0x94240dc}, 0x9c489c0)
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:1269 +0xc84
cmd/go/internal/work.ActorFunc.Act(0x64a9e0, 0x9c91340, {0x6e06b4, 0x94240dc}, 0x9c489c0)
	/boot/workdir/go/src/cmd/go/internal/work/action.go:76 +0x3c
cmd/go/internal/work.(*Builder).Do.func2({0x6e06b4, 0x94240dc}, 0x9c489c0)
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:143 +0x6f0
cmd/go/internal/work.(*Builder).Do.func3()
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:211 +0xc8
created by cmd/go/internal/work.(*Builder).Do
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:197 +0x394

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2022-12-21 20:05 plan9-arm go@c9a10d48 (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x15aa8]

goroutine 1412 [running]:
runtime.throw({0x43c0a8, 0x2a})
	/boot/workdir/go/src/runtime/panic.go:1047 +0x4c fp=0x92a5440 sp=0x92a542c pc=0x3b840
runtime.sigpanic()
	/boot/workdir/go/src/runtime/os_plan9.go:80 +0x4e8 fp=0x92a5480 sp=0x92a5440 pc=0x37510
runtime.writeHeapBits.flush({0x9200000, 0x1, 0x1, 0x0}, 0x9200000, 0x0)
	/boot/workdir/go/src/runtime/mbitmap.go:898 +0x160 fp=0x92a5490 sp=0x92a5484 pc=0x15aa8
runtime.heapBitsSetType(0x9200000, 0x0, 0x8, 0x3e2748)
	/boot/workdir/go/src/runtime/mbitmap.go:1082 +0x298 fp=0x92a5500 sp=0x92a5490 pc=0x15db8
runtime.mallocgc(0x8, 0x3e2748, 0x1)
	/boot/workdir/go/src/runtime/malloc.go:1074 +0x730 fp=0x92a5538 sp=0x92a5500 pc=0xd55c
runtime.convTstring({0x9471c22, 0xf})
	/boot/workdir/go/src/runtime/iface.go:392 +0x44 fp=0x92a554c sp=0x92a5538 pc=0xae24
cmd/go/internal/work.(*Builder).buildActionID(0x95a6770, 0x95bf500)
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:383 +0x1fac fp=0x92a578c sp=0x92a554c pc=0x331b54
cmd/go/internal/work.(*Builder).build(0x95a6770, {0x4cf7dc, 0x90243ac}, 0x95bf500)
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:467 +0x210 fp=0x92a5e78 sp=0x92a578c pc=0x3321d4
cmd/go/internal/work.ActorFunc.Act(0x468abc, 0x95a6770, {0x4cf7dc, 0x90243ac}, 0x95bf500)
	/boot/workdir/go/src/cmd/go/internal/work/action.go:76 +0x3c fp=0x92a5e94 sp=0x92a5e78 pc=0x31f7d4
cmd/go/internal/work.(*Builder).Do.func2({0x4cf7dc, 0x90243ac}, 0x95bf500)
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:143 +0x6f0 fp=0x92a5f84 sp=0x92a5e94 pc=0x32f838
cmd/go/internal/work.(*Builder).Do.func3()
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:211 +0xc8 fp=0x92a5fec sp=0x92a5f84 pc=0x32efc0
runtime.goexit()
	/boot/workdir/go/src/runtime/asm_arm.s:831 +0x4 fp=0x92a5fec sp=0x92a5fec pc=0x6b358
created by cmd/go/internal/work.(*Builder).Do
	/boot/workdir/go/src/cmd/go/internal/work/exec.go:197 +0x394

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-01-19 20:44 plan9-arm go@3bb8864e (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0xd2c0]

runtime stack:
runtime.throw({0x43be80, 0x2a})
	/boot/workdir/go/src/runtime/panic.go:1047 +0x4c fp=0x3ffffc80 sp=0x3ffffc6c pc=0x3b840
runtime.sigpanic()
	/boot/workdir/go/src/runtime/os_plan9.go:80 +0x4e8 fp=0x3ffffcc0 sp=0x3ffffc80 pc=0x37510
runtime.nextFreeFast(...)
	/boot/workdir/go/src/runtime/malloc.go:819
runtime.mallocgc(0x21c, 0x423210, 0x1)
	/boot/workdir/go/src/runtime/malloc.go:1040 +0x494 fp=0x3ffffcfc sp=0x3ffffcc4 pc=0xd2c0
runtime.newobject(0x423210)
	/boot/workdir/go/src/runtime/malloc.go:1254 +0x2c fp=0x3ffffd10 sp=0x3ffffcfc pc=0xda48
runtime.allocm(0x903a600, 0x468d88, 0xc)
	/boot/workdir/go/src/runtime/proc.go:1831 +0x9c fp=0x3ffffd3c sp=0x3ffffd10 pc=0x42308
runtime.newm(0x468d88, 0x903a600, 0xc)
	/boot/workdir/go/src/runtime/proc.go:2196 +0x4c fp=0x3ffffd54 sp=0x3ffffd3c pc=0x429e8
runtime.startm(0x903a600, 0x1)
	/boot/workdir/go/src/runtime/proc.go:2411 +0x110 fp=0x3ffffd80 sp=0x3ffffd54 pc=0x42fbc
runtime.wakep()
	/boot/workdir/go/src/runtime/proc.go:2541 +0xcc fp=0x3ffffda0 sp=0x3ffffd80 pc=0x43650
runtime.resetspinning()
	/boot/workdir/go/src/runtime/proc.go:3244 +0x50 fp=0x3ffffdb0 sp=0x3ffffda0 pc=0x457c8
runtime.schedule()
	/boot/workdir/go/src/runtime/proc.go:3366 +0xd8 fp=0x3ffffdcc sp=0x3ffffdb0 pc=0x45d94
runtime.park_m(0x90032c0)
	/boot/workdir/go/src/runtime/proc.go:3511 +0x150 fp=0x3ffffde0 sp=0x3ffffdcc pc=0x46558
runtime.mcall()
	/boot/workdir/go/src/runtime/asm_arm.s:265 +0x48 fp=0x3ffffde8 sp=0x3ffffde0 pc=0x697e0

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-03-07 14:28 plan9-arm benchmarks@2652dad2 go@d6fa0d2e (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x1b29c]

goroutine 31826 [running]:
io.copyBuffer({0x925f878, 0x9a82460}, {0x707ea0, 0x9882bb0}, {0x0, 0x0, 0x0})
	io/io.go:424 +0x118
io.Copy(...)
	io/io.go:386
cmd/go/internal/cache.FileHash({0x9c54750, 0x2a})
	cmd/go/internal/cache/hash.go:165 +0x244
cmd/go/internal/work.(*Builder).fileHash(0x9fe5180, {0x9c54750, 0x2a})
	cmd/go/internal/work/buildid.go:388 +0x38
cmd/go/internal/work.(*Builder).buildActionID(0x9fe5180, 0x9cad8c0)
	cmd/go/internal/work/exec.go:386 +0x1f28
cmd/go/internal/work.(*Builder).build(0x9fe5180, {0x70a788, 0x9f6a0c}, 0x9cad8c0)
	cmd/go/internal/work/exec.go:470 +0x1fc
cmd/go/internal/work.ActorFunc.Act(0x670448, 0x9fe5180, {0x70a788, 0x9f6a0c}, 0x9cad8c0)
	cmd/go/internal/work/action.go:77 +0x3c
cmd/go/internal/work.(*Builder).Do.func2({0x70a788, 0x9f6a0c}, 0x9cad8c0)
	cmd/go/internal/work/exec.go:146 +0x764
cmd/go/internal/work.(*Builder).Do.func3()
	cmd/go/internal/work/exec.go:214 +0xc8
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:200 +0x3a0

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-03-09 22:21 plan9-arm net@9f24bb44 go@7c019c62 (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0xa2 pc=0x4e5280]

goroutine 6770 [running]:
cmd/go/internal/work.(*Builder).Do.func2({0x7098a0, 0x9f695c}, 0x97e7c80)
	cmd/go/internal/work/exec.go:177 +0x664
cmd/go/internal/work.(*Builder).Do.func3()
	cmd/go/internal/work/exec.go:214 +0xc8
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:200 +0x3a0

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-03-28 22:22 plan9-arm go@91a40f43 (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x20 pc=0x3ed540]

goroutine 409 [running]:
panic({0x5cb8a0, 0x9e60e8})
	runtime/panic.go:1016 +0x434 fp=0x96a7438 sp=0x96a73e4 pc=0x3ba40
runtime.panicmem(...)
	runtime/panic.go:260
runtime.sigpanic()
	runtime/os_plan9.go:97 +0x388 fp=0x96a7478 sp=0x96a7438 pc=0x37b2c
cmd/go/internal/cache.(*Hash).Write(0x9506888, {0x9414d80, 0x23, 0x80})
	cmd/go/internal/cache/hash.go:99 +0xf8 fp=0x96a74b8 sp=0x96a747c pc=0x3ed540
fmt.Fprintf({0x70d9c8, 0x9506888}, {0x62b247, 0x11}, {0x96a7650, 0x3, 0x3})
	fmt/print.go:225 +0x78 fp=0x96a74e8 sp=0x96a74b8 pc=0xf1e6c
cmd/go/internal/work.(*Builder).buildActionID(0x9656bd0, 0x986cb40)
	cmd/go/internal/work/exec.go:324 +0x1134 fp=0x96a7708 sp=0x96a74e8 pc=0x4eb724
cmd/go/internal/work.(*Builder).build(0x9656bd0, {0x710d08, 0xa019d4}, 0x986cb40)
	cmd/go/internal/work/exec.go:470 +0x1fc fp=0x96a7e54 sp=0x96a7708 pc=0x4ecba0
cmd/go/internal/work.ActorFunc.Act(0x675d3c, 0x9656bd0, {0x710d08, 0xa019d4}, 0x986cb40)
	cmd/go/internal/work/action.go:77 +0x3c fp=0x96a7e70 sp=0x96a7e54 pc=0x4da284
cmd/go/internal/work.(*Builder).Do.func2({0x710d08, 0xa019d4}, 0x986cb40)
	cmd/go/internal/work/exec.go:146 +0x764 fp=0x96a7f84 sp=0x96a7e70 pc=0x4ea27c
cmd/go/internal/work.(*Builder).Do.func3()
	cmd/go/internal/work/exec.go:214 +0xc8 fp=0x96a7fec sp=0x96a7f84 pc=0x4e9988
runtime.goexit()
	runtime/asm_arm.s:859 +0x4 fp=0x96a7fec sp=0x96a7fec pc=0x708ac
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:200 +0x3a0

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-04-13 22:30 plan9-arm go@11dd32d7 (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x12c7c]

runtime stack:
runtime.throw({0x133f3d, 0x2a})
	/boot/workdir/go1.4/src/runtime/panic.go:1198 +0x5c
runtime.sigpanic()
	/boot/workdir/go1.4/src/runtime/os_plan9.go:79 +0x4b4
runtime.spanOf(...)
	/boot/workdir/go1.4/src/runtime/mheap.go:652
runtime.findObject(0x10a061e0, 0x10ab4150, 0x0)
	/boot/workdir/go1.4/src/runtime/mbitmap.go:385 +0x10
runtime.scanobject(0x10ab4150, 0x10832b84)
	/boot/workdir/go1.4/src/runtime/mgcmark.go:1280 +0x160
runtime.gcDrainN(0x10832b84, 0x10000)
	/boot/workdir/go1.4/src/runtime/mgcmark.go:1141 +0x1e0
runtime.gcAssistAlloc1(0x10bb4e10, 0x10000)
	/boot/workdir/go1.4/src/runtime/mgcmark.go:537 +0x16c
runtime.gcAssistAlloc.func1()
	/boot/workdir/go1.4/src/runtime/mgcmark.go:448 +0x2c
runtime.systemstack()
	/boot/workdir/go1.4/src/runtime/asm_arm.s:318 +0x60

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-05-17 20:54 plan9-arm tools@8b4b27bc go@7b0835d4 x/tools/go/analysis/passes/reflectvaluecompare.TestReflectValueCompare (log)
fatal: systemstack called from unexpected goroutinereflectvaluecompare.test 10783: suicide: sys: trap: fault read va=0x4 pc=0x7660c
panic: test timed out after 30m0s
running tests:
	TestReflectValueCompare (30m0s)

golang.org/x/tools/internal/gocommand.runCmdContext({0x3324a0, 0x8c1b5f0}, 0x8ca4840)
	/boot/workdir/gopath/src/golang.org/x/tools/internal/gocommand/invoke.go:376 +0x468
golang.org/x/tools/internal/gocommand.(*Invocation).run(0x8cad3bc, {0x3324a0, 0x8c1b5f0}, {0x330d54, 0x8c8e648}, {0x330d54, 0x8c8e660})
	/boot/workdir/gopath/src/golang.org/x/tools/internal/gocommand/invoke.go:267 +0xf88
golang.org/x/tools/internal/gocommand.(*Invocation).runWithFriendlyError(0x8cad3bc, {0x3324a0, 0x8c1b5f0}, {0x330d54, 0x8c8e648}, {0x330d54, 0x8c8e660})
...
	/boot/workdir/gopath/src/golang.org/x/tools/go/packages/packages.go:278 +0x58
golang.org/x/tools/go/packages.Load(0x8c38ea4, {0x8c1ee08, 0x1, 0x1})
	/boot/workdir/gopath/src/golang.org/x/tools/go/packages/packages.go:261 +0x4c
golang.org/x/tools/go/analysis/analysistest.loadPackages(0x492ef0, {0x8c2c1e0, 0x5b}, {0x8c1ee08, 0x1, 0x1})
	/boot/workdir/gopath/src/golang.org/x/tools/go/analysis/analysistest/analysistest.go:332 +0x1b0
golang.org/x/tools/go/analysis/analysistest.Run({0x330c20, 0x8cc40f0}, {0x8c2c1e0, 0x5b}, 0x492ef0, {0x8c1ee08, 0x1, 0x1})
	/boot/workdir/gopath/src/golang.org/x/tools/go/analysis/analysistest/analysistest.go:286 +0x80
golang.org/x/tools/go/analysis/passes/reflectvaluecompare_test.TestReflectValueCompare(0x8cc40f0)
	/boot/workdir/gopath/src/golang.org/x/tools/go/analysis/passes/reflectvaluecompare/reflectvaluecompare_test.go:16 +0x8c
testing.tRunner(0x8cc40f0, 0x2df2ec)

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-05-31 21:19 plan9-arm go@bf146639 (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x10 pc=0x123f88]

goroutine 695 [running]:
panic({0x60c938, 0xa657a0})
	runtime/panic.go:1017 +0x434 fp=0x94d9358 sp=0x94d9304 pc=0x40934
runtime.panicmem(...)
	runtime/panic.go:261
runtime.sigpanic()
	runtime/os_plan9.go:92 +0x388 fp=0x94d9398 sp=0x94d9358 pc=0x3ca48
...
	cmd/go/internal/work/exec.go:219 +0xcc fp=0x94d9fec sp=0x94d9f84 pc=0x5280a4
runtime.goexit()
	runtime/asm_arm.s:859 +0x4 fp=0x94d9fec sp=0x94d9fec pc=0x76b6c
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:205 +0x3b0

goroutine 36 [running]:
	goroutine running on other thread; stack unavailable
created by runtime.gcBgMarkStartWorkers in goroutine 17
	runtime/mgc.go:1217 +0x20

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-07-20 19:30 plan9-arm go@3ffc8a25 (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x1a0ac]

runtime stack:
runtime.throw({0x4a30d4, 0x2a})
	/boot/workdir/go/src/runtime/panic.go:1077 +0x4c fp=0x3ffffc8c sp=0x3ffffc78 pc=0x40c68
runtime.sigpanic()
	/boot/workdir/go/src/runtime/os_plan9.go:75 +0x4d4 fp=0x3ffffccc sp=0x3ffffc8c pc=0x3cb08
runtime.(*mcache).prepareForSweep(0x0)
	/boot/workdir/go/src/runtime/mcache.go:321 +0x14 fp=0x3ffffce8 sp=0x3ffffcd0 pc=0x1a0ac
runtime.acquirep(0x9039900)
	/boot/workdir/go/src/runtime/proc.go:5339 +0x2c fp=0x3ffffd08 sp=0x3ffffce8 pc=0x4f5fc
runtime.stopm()
	/boot/workdir/go/src/runtime/proc.go:2538 +0xb4 fp=0x3ffffd1c sp=0x3ffffd08 pc=0x48398
runtime.findRunnable()
	/boot/workdir/go/src/runtime/proc.go:3233 +0xd58 fp=0x3ffffdc4 sp=0x3ffffd1c pc=0x49f40
runtime.schedule()
	/boot/workdir/go/src/runtime/proc.go:3587 +0xac fp=0x3ffffde0 sp=0x3ffffdc4 pc=0x4b128
runtime.park_m(0x9202d00)
	/boot/workdir/go/src/runtime/proc.go:3750 +0x160 fp=0x3ffffdfc sp=0x3ffffde0 pc=0x4b9b4
runtime.mcall()
	/boot/workdir/go/src/runtime/asm_arm.s:265 +0x48 fp=0x3ffffe04 sp=0x3ffffdfc pc=0x74f78

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-07-31 18:04 plan9-arm go@24af43fa (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x49408]

runtime stack:
runtime.throw({0x68f521, 0x2a})
	runtime/panic.go:837 +0x4c fp=0x3ffffba0 sp=0x3ffffb8c pc=0x40b9c
runtime.sigpanic()
	runtime/os_plan9.go:75 +0x4d4 fp=0x3ffffbe0 sp=0x3ffffba0 pc=0x3cfa0
runtime.findRunnable()
	runtime/proc.go:2953 +0x240 fp=0x3ffffc94 sp=0x3ffffbe4 pc=0x49408
runtime.schedule()
	runtime/proc.go:3605 +0xac fp=0x3ffffcb0 sp=0x3ffffc94 pc=0x4b1e0
runtime.park_m(0x9402800)
	runtime/proc.go:3768 +0x160 fp=0x3ffffccc sp=0x3ffffcb0 pc=0x4ba6c
runtime.mcall()
	runtime/asm_arm.s:265 +0x48 fp=0x3ffffcd4 sp=0x3ffffccc pc=0x74ef0

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-07 00:23 plan9-arm go@b55e4a7e (log)
runtime: g 679: unknown pc 0xfdab8
stack: frame={sp:0x95b182c, fp:0x0} stack=[0x95b0000,0x95b2000)
0x095b17ac:  0x00000001  0x0933fc68  0x00a80778  0x00040734 
0x095b17bc:  0x000403e8  0x095b17c4  0x0004074c  0x095b17f4 
0x095b17cc:  0x096cbd00  0x095b17dc  0x0003fca0  0x095b17f4 
0x095b17dc:  0x00002000  0x096cbd00  0x000fdab8  0x095b17f4 
0x095b17ec:  0x000fdab8  0x095b182c  0x00000000  0x00000000 
0x095b17fc:  0x00000000  0x00000000  0x0003fca0  0x095b17e4 
0x095b180c:  0x00000000  0x000fdab8  0x095b182c  0x00000000 
0x095b181c:  0x00000000  0x00000000  0x00000000  0x01000000 
...
fatal error: unknown pc

runtime stack:
runtime: g 0: unknown pc 0x40bbc
stack: frame={sp:0x3ffff9d0, fp:0x0} stack=[0x3ffefc4c,0x3ffffc4c)
0x3ffff950:  0x3ffff9d0  0x00000000  0x09403700  0x00000001 
0x3ffff960:  0x00040fb8  0x00040bbc  0x3ffff9d0  0x00000000 
0x3ffff970:  0x09403700  0x00000000  0x01000000  0x00000000 
0x3ffff980:  0x00040f9c  0x00a75178  0x00000001  0x00000001 
0x3ffff990:  0x09403700  0x00040f58  0x09403700  0x00040bbc 
...
0x095b1798:  0x00000020  0x000fe5c8  0x00610608  0x005f6698 
0x095b17a8:  0x00098b20  0x00000001  0x0933fc68  0x00a80778 
0x095b17b8: <0x00040734  0x000403e8  0x095b17c4  0x0004074c 
0x095b17c8:  0x095b17f4  0x096cbd00  0x095b17dc  0x0003fca0 
0x095b17d8:  0x095b17f4  0x00002000  0x096cbd00  0x000fdab8 
0x095b17e8:  0x095b17f4  0x000fdab8  0x095b182c  0x00000000 
0x095b17f8:  0x00000000  0x00000000  0x00000000  0x0003fca0 
0x095b1808:  0x095b17e4  0x00000000  0x000fdab8  0x095b182c 
0x095b1818:  0x00000000  0x00000000  0x00000000  0x00000000 
0x095b1828:  0x01000000  0x000fe5c8  0x00610608  0x005f6698 

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-07 12:58 plan9-arm tools@2dc7ebab go@009c628b x/tools/gopls/internal/lsp/analysis/deprecated.Test (log)
--- FAIL: Test (12.16s)
    analysistest.go:292: loading [a]: err: exit status: 'go 18728: 2': stderr: fatal error: unexpected signal during runtime execution
        [signal sys: trap: fault read code=0x0 addr=0x0 pc=0x3b39c]

        runtime stack:
        runtime.throw({0x68ec49, 0x2a})
        	runtime/panic.go:845 +0x4c fp=0x3ffffa74 sp=0x3ffffa60 pc=0x40bbc
        runtime.sigpanic()
        	runtime/os_plan9.go:75 +0x4d4 fp=0x3ffffab4 sp=0x3ffffa74 pc=0x3cf74
        runtime.(*spanSet).push(0xa69bc0, 0x9389d70)
...
        runtime.gcMarkTermination()
        	runtime/mgc.go:1101 +0x6f8 fp=0x9905f4c sp=0x9905da0 pc=0x20368
        runtime.gcMarkDone()
        	runtime/mgc.go:941 +0x2fc fp=0x9905f80 sp=0x9905f4c pc=0x1fb28
        runtime.gcBgMarkWorker()
        	runtime/mgc.go:1445 +0x3e8 fp=0x9905fec sp=0x9905f80 pc=0x21614
        runtime.goexit()
        	runtime/asm_arm.s:859 +0x4 fp=0x9905fec sp=0x9905fec pc=0x76a5c
        created by runtime.gcBgMarkStartWorkers in goroutine 1
        	runtime/mgc.go:1237 +0x20

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-06-21 11:18 plan9-arm mod@baa5c2d0 go@8a6acecf (log)
panic: runtime error: invalid memory address or nil pointer dereference [recovered]
	panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x4 pc=0x1b11a8]

goroutine 2278 [running]:
encoding/json.(*encodeState).marshal.func1()
	encoding/json/encode.go:291 +0x90
panic({0x617060, 0xa598a0})
	runtime/panic.go:612 +0xfc
encoding/json.appendString[...]({0x9a720ac, 0x0, 0x1f54}, {0x4, 0x98ea000}, 0x1)
...
cmd/go/internal/work.(*Builder).vet(0x9808af0, {0x76e928, 0xa76090}, 0x9abbb00)
	cmd/go/internal/work/exec.go:1294 +0x798
cmd/go/internal/work.ActorFunc.Act(0x6c7080, 0x9808af0, {0x76e928, 0xa76090}, 0x9abbb00)
	cmd/go/internal/work/action.go:78 +0x3c
cmd/go/internal/work.(*Builder).Do.func3({0x76e928, 0xa76090}, 0x9abbb00)
	cmd/go/internal/work/exec.go:151 +0x764
cmd/go/internal/work.(*Builder).Do.func4()
	cmd/go/internal/work/exec.go:219 +0xcc
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:205 +0x3a8

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-07 22:48 plan9-arm go@b9153f6e (log)
panic: runtime error: invalid memory address or nil pointer dereference
[signal sys: trap: fault read code=0x0 addr=0x2 pc=0xf0c3c]

goroutine 562 [running]:
panic({0x617160, 0xa5a8a0})
	runtime/panic.go:621 +0x12c fp=0x962ff14 sp=0x962fec0 pc=0x400dc
runtime.panicmem(...)
	runtime/panic.go:261
runtime.sigpanic()
	runtime/os_plan9.go:92 +0x390 fp=0x962ff54 sp=0x962ff14 pc=0x3ce30
os.(*file).close(0x2)
	os/file_plan9.go:153 +0x14 fp=0x962ff74 sp=0x962ff58 pc=0xf0c3c
os.(*File).Close(...)
	os/file_plan9.go:149
os/exec.(*Cmd).writerDescriptor.func1()
	os/exec/exec.go:561 +0x7c fp=0x962ffb0 sp=0x962ff74 pc=0x1262a0
os/exec.(*Cmd).Start.func2(0x9688220)
	os/exec/exec.go:689 +0x30 fp=0x962ffe4 sp=0x962ffb0 pc=0x126eb4
os/exec.(*Cmd).Start.func3()
	os/exec/exec.go:701 +0x30 fp=0x962ffec sp=0x962ffe4 pc=0x126e58
runtime.goexit()
	runtime/asm_arm.s:859 +0x4 fp=0x962ffec sp=0x962ffec pc=0x76b64
created by os/exec.(*Cmd).Start in goroutine 400
	os/exec/exec.go:688 +0x96c

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-16 16:38 plan9-arm go@9049d77d (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0xe54c]

goroutine 718 [running]:
runtime.throw({0x688394, 0x2a})
	runtime/panic.go:859 +0x4c fp=0x96ef38c sp=0x96ef378 pc=0x410a0
runtime.sigpanic()
	runtime/os_plan9.go:75 +0x4d4 fp=0x96ef3cc sp=0x96ef38c pc=0x3d434
runtime.lock2(0x6a)
	runtime/lock_sema.go:46 +0x30 fp=0x96ef3f8 sp=0x96ef3d0 pc=0xe54c
...
cmd/go/internal/work.ActorFunc.Act(0x6bfaa0, 0x9812c40, {0x766770, 0xa69fc0}, 0x983b8c0)
	cmd/go/internal/work/action.go:78 +0x3c fp=0x96efe70 sp=0x96efe54 pc=0x5116a0
cmd/go/internal/work.(*Builder).Do.func3({0x766770, 0xa69fc0}, 0x983b8c0)
	cmd/go/internal/work/exec.go:151 +0x764 fp=0x96eff84 sp=0x96efe70 pc=0x5217f8
cmd/go/internal/work.(*Builder).Do.func4()
	cmd/go/internal/work/exec.go:219 +0xcc fp=0x96effec sp=0x96eff84 pc=0x520f08
runtime.goexit()
	runtime/asm_arm.s:859 +0x4 fp=0x96effec sp=0x96effec pc=0x77148
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:205 +0x3a8

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-17 21:51 plan9-arm go@639f6f7e (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x3b85c]

goroutine 603 [running]:
runtime.throw({0x689d3c, 0x2a})
	runtime/panic.go:1018 +0x4c fp=0x966bb44 sp=0x966bb30 pc=0x41224
runtime.sigpanic()
	runtime/os_plan9.go:75 +0x4d4 fp=0x966bb84 sp=0x966bb44 pc=0x3d434
runtime.(*spanSet).push(0xa60d08, 0xa822d8)
	runtime/mspanset.go:136 +0x228 fp=0x966bbc8 sp=0x966bb88 pc=0x3b85c
...
cmd/go/internal/work.ActorFunc.Act(0x6c1474, 0x967e460, {0x768ae0, 0xa6cfc0}, 0x967b200)
	cmd/go/internal/work/action.go:78 +0x3c fp=0x966be70 sp=0x966be54 pc=0x513024
cmd/go/internal/work.(*Builder).Do.func3({0x768ae0, 0xa6cfc0}, 0x967b200)
	cmd/go/internal/work/exec.go:151 +0x764 fp=0x966bf84 sp=0x966be70 pc=0x523184
cmd/go/internal/work.(*Builder).Do.func4()
	cmd/go/internal/work/exec.go:219 +0xcc fp=0x966bfec sp=0x966bf84 pc=0x52288c
runtime.goexit()
	runtime/asm_arm.s:859 +0x4 fp=0x966bfec sp=0x966bfec pc=0x773b0
created by cmd/go/internal/work.(*Builder).Do in goroutine 1
	cmd/go/internal/work/exec.go:205 +0x3a8

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-21 18:18 plan9-arm arch@b6e87532 go@05f95115 (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x4bb74]

runtime stack:
runtime.throw({0x689c39, 0x2a})
	runtime/panic.go:1018 +0x4c fp=0x3ffffa94 sp=0x3ffffa80 pc=0x41218
runtime.sigpanic()
	runtime/os_plan9.go:75 +0x4d4 fp=0x3ffffad4 sp=0x3ffffa94 pc=0x3d42c
runtime.schedule()
	runtime/proc.go:3645 +0x2a4 fp=0x3ffffaf4 sp=0x3ffffad8 pc=0x4bb74
runtime.park_m(0x9ac3a00)
	runtime/proc.go:3765 +0x160 fp=0x3ffffb10 sp=0x3ffffaf4 pc=0x4c208
runtime.mcall()
	runtime/asm_arm.s:265 +0x48 fp=0x3ffffb18 sp=0x3ffffb10 pc=0x757dc

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-08-25 15:10 plan9-arm go@882a356e (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x15bc0]

runtime stack:
runtime.throw({0x15cc18, 0x2a})
	/boot/workdir/go1.4/src/runtime/panic.go:1047 +0x4c fp=0x3ffffce0 sp=0x3ffffccc pc=0x3927c
runtime.sigpanic()
	/boot/workdir/go1.4/src/runtime/os_plan9.go:80 +0x4e8 fp=0x3ffffd20 sp=0x3ffffce0 pc=0x352dc
runtime.(*mcache).prepareForSweep(0x0)
	/boot/workdir/go1.4/src/runtime/mcache.go:321 +0x14 fp=0x3ffffd3c sp=0x3ffffd24 pc=0x15bc0
runtime.acquirep(0x8c32000)
	/boot/workdir/go1.4/src/runtime/proc.go:5115 +0x2c fp=0x3ffffd44 sp=0x3ffffd3c pc=0x4743c
runtime.stopm()
	/boot/workdir/go1.4/src/runtime/proc.go:2336 +0xb0 fp=0x3ffffd58 sp=0x3ffffd44 pc=0x40394
runtime.findRunnable()
	/boot/workdir/go1.4/src/runtime/proc.go:3025 +0xd44 fp=0x3ffffdf8 sp=0x3ffffd58 pc=0x41f04
runtime.schedule()
	/boot/workdir/go1.4/src/runtime/proc.go:3378 +0xac fp=0x3ffffe14 sp=0x3ffffdf8 pc=0x431fc
runtime.park_m(0x8c02b40)
	/boot/workdir/go1.4/src/runtime/proc.go:3529 +0x150 fp=0x3ffffe28 sp=0x3ffffe14 pc=0x439ec
runtime.mcall()
	/boot/workdir/go1.4/src/runtime/asm_arm.s:265 +0x48 fp=0x3ffffe30 sp=0x3ffffe28 pc=0x6664c

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-09-15 20:17 plan9-arm tools@866a6b0f go@c05fceb7 x/tools/go/analysis/passes/lostcancel.Test (log)
--- FAIL: Test (11.33s)
    analysistest.go:319: loading [a b typeparams]: err: exit status: 'go 12268: 2': stderr: fatal error: unexpected signal during runtime execution
        [signal sys: trap: fault read code=0x0 addr=0x0 pc=0x1946c]

        goroutine 230 [running]:
        runtime.throw({0x685615, 0x2a})
        	runtime/panic.go:1018 +0x4c fp=0x96b13a0 sp=0x96b138c pc=0x41354
        runtime.sigpanic()
        	runtime/os_plan9.go:75 +0x4d4 fp=0x96b13e0 sp=0x96b13a0 pc=0x3d57c
        runtime.writeHeapBits.flush({0x9780000, 0x25, 0x6, 0x0}, 0x9780000, 0x0)
...
        cmd/go/internal/work.ActorFunc.Act(0x6bce70, 0x9420930, {0x764b90, 0xa6c170}, 0x973a0c0)
        	cmd/go/internal/work/action.go:78 +0x3c fp=0x96b1e70 sp=0x96b1e54 pc=0x5141e8
        cmd/go/internal/work.(*Builder).Do.func3({0x764b90, 0xa6c170}, 0x973a0c0)
        	cmd/go/internal/work/exec.go:151 +0x764 fp=0x96b1f84 sp=0x96b1e70 pc=0x524188
        cmd/go/internal/work.(*Builder).Do.func4()
        	cmd/go/internal/work/exec.go:219 +0xcc fp=0x96b1fec sp=0x96b1f84 pc=0x523890
        runtime.goexit({})
        	runtime/asm_arm.s:859 +0x4 fp=0x96b1fec sp=0x96b1fec pc=0x770ec
        created by cmd/go/internal/work.(*Builder).Do in goroutine 1
        	cmd/go/internal/work/exec.go:205 +0x3a8

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-09-20 18:05 plan9-arm go@bebf82cb (log)
Test {"go_test:internal/poll" "internal/poll"} ran over 1h0m0s limit (1h0m0.000786691s); saw output:


XXXBANNERXXX:Testing packages.
fatal: systemstack called from unexpected goroutinego 28976: suicide: sys: trap: fault read va=0x4 pc=0x77ea4
2023-09-25 14:43 plan9-arm go@de3bae19 (log)
fatal error: unexpected signal during runtime execution
fatal error: unexpected signal during runtime execution
panic during panic
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x3f554]

runtime stack:
runtime.throw({0x61f923, 0x2a})
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/panic.go:1047 +0x4c fp=0x3ffffbdc sp=0x3ffffbc8 pc=0x3aca0
runtime.sigpanic()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/os_plan9.go:80 +0x4e8 fp=0x3ffffc1c sp=0x3ffffbdc pc=0x36aa4
runtime.preemptall(...)
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/proc.go:5531
runtime.freezetheworld()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/proc.go:916 +0x170 fp=0x3ffffc30 sp=0x3ffffc20 pc=0x3f554
runtime.startpanic_m()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/panic.go:1220 +0x15c fp=0x3ffffc44 sp=0x3ffffc30 pc=0x3b2d0
runtime.fatalthrow.func1()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/panic.go:1125 +0x2c fp=0x3ffffc64 sp=0x3ffffc44 pc=0x3afc8
runtime.fatalthrow(0x2)
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/panic.go:1120 +0x64 fp=0x3ffffc80 sp=0x3ffffc64 pc=0x3af84
runtime.throw({0x61f923, 0x2a})
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/panic.go:1047 +0x4c fp=0x3ffffc94 sp=0x3ffffc80 pc=0x3aca0
runtime.sigpanic()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/os_plan9.go:80 +0x4e8 fp=0x3ffffcd4 sp=0x3ffffc94 pc=0x36aa4
runtime.forEachP(0x6565d0)
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/proc.go:1673 +0xe4 fp=0x3ffffd10 sp=0x3ffffcd8 pc=0x41094
runtime.gcMarkDone.func1()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/mgc.go:814 +0x4c fp=0x3ffffd24 sp=0x3ffffd10 pc=0x663e4
runtime.systemstack()
	/tmp/genbootstrap-3479644045/go-plan9-arm-bootstrap/src/runtime/asm_arm.s:317 +0x60 fp=0x3ffffd28 sp=0x3ffffd24 pc=0x69950

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-09-22 21:51 plan9-arm oauth2@14b275c9 go@5152be39 (log)
runtime: program exceeds 0-thread limit
fatal error: thread exhaustion

runtime stack:
runtime.throw({0x670c18, 0x11})
	runtime/panic.go:1018 +0x4c fp=0x3ffffd74 sp=0x3ffffd60 pc=0x41354
runtime.checkmcount()
	runtime/proc.go:805 +0xd4 fp=0x3ffffd90 sp=0x3ffffd74 pc=0x45874
runtime.mReserveID()
	runtime/proc.go:821 +0x74 fp=0x3ffffda4 sp=0x3ffffd90 pc=0x4591c
...
runtime.retake(0x1788ab41d31b6a80)
	runtime/proc.go:5745 +0x2f8 fp=0x3ffffe20 sp=0x3ffffdf8 pc=0x513a4
runtime.sysmon()
	runtime/proc.go:5653 +0x5d0 fp=0x3ffffe8c sp=0x3ffffe20 pc=0x50eb8
runtime.mstart1()
	runtime/proc.go:1601 +0x7c fp=0x3ffffe9c sp=0x3ffffe8c pc=0x47604
runtime.mstart0()
	runtime/proc.go:1558 +0x64 fp=0x3ffffeac sp=0x3ffffe9c pc=0x47578
runtime.mstart()
	runtime/asm_arm.s:210 +0x8 fp=0x3ffffeb0 sp=0x3ffffeac pc=0x754d4

watchflakes

@gopherbot
Copy link

Found new dashboard test flakes for:

#!watchflakes
post <- builder ~ `^plan9-.*` && `(suicide:|fatal error:|signal) sys: trap: (fault|general protection violation)`
2023-10-02 20:28 plan9-arm go@eb070d74 (log)
fatal error: unexpected signal during runtime execution
[signal sys: trap: fault read code=0x0 addr=0x0 pc=0x1a904]

runtime stack:
runtime.throw({0x686517, 0x2a})
	runtime/panic.go:1018 +0x4c fp=0x3ffffb74 sp=0x3ffffb60 pc=0x4122c
runtime.sigpanic()
	runtime/os_plan9.go:75 +0x4d4 fp=0x3ffffbb4 sp=0x3ffffb74 pc=0x3d454
runtime.(*mcache).prepareForSweep(0x0)
	runtime/mcache.go:321 +0x14 fp=0x3ffffbd0 sp=0x3ffffbb8 pc=0x1a904
runtime.acquirep(0x9435900)
	runtime/proc.go:5347 +0x2c fp=0x3ffffbf0 sp=0x3ffffbd0 pc=0x4fde8
runtime.exitsyscallfast_pidle()
	runtime/proc.go:4322 +0xcc fp=0x3ffffc0c sp=0x3ffffbf0 pc=0x4d8f8
runtime.exitsyscallfast.func1()
	runtime/proc.go:4271 +0x2c fp=0x3ffffc24 sp=0x3ffffc0c pc=0x4d6f0
traceback: unexpected SPWRITE function runtime.systemstack
runtime.systemstack(0x1)
	runtime/asm_arm.s:317 +0x60 fp=0x3ffffc28 sp=0x3ffffc24 pc=0x75484

watchflakes

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
compiler/runtime Issues related to the Go compiler and/or runtime. NeedsInvestigation Someone must examine and confirm this is a valid issue and not a duplicate of an existing one. OS-Plan9
Projects
Status: Triage Backlog
Status: No status
Development

No branches or pull requests

2 participants