From 5a9db5198745fd9dc1be713bda97975c38b0b477 Mon Sep 17 00:00:00 2001 From: HOS Date: Thu, 15 Sep 2022 14:08:51 +0200 Subject: [PATCH] The dT is a temperature difference, so converting it to celsius shouldn't use an offset. --- Modelica/Fluid/Examples/HeatExchanger.mo | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Modelica/Fluid/Examples/HeatExchanger.mo b/Modelica/Fluid/Examples/HeatExchanger.mo index 9c11affb53..734c71aa44 100644 --- a/Modelica/Fluid/Examples/HeatExchanger.mo +++ b/Modelica/Fluid/Examples/HeatExchanger.mo @@ -419,7 +419,7 @@ The design flow direction with positive m_flow variables is counterflow.

"Formulation of energy balance" annotation(Evaluate=true, Dialog(tab = "Assumptions", group="Dynamics")); parameter SI.Temperature T_start "Wall temperature start value"; - parameter SI.Temperature dT "Start value for port_b.T - port_a.T"; + parameter SI.TemperatureDifference dT "Start value for port_b.T - port_a.T"; //Temperatures SI.Temperature[n] Tb(each start=T_start+0.5*dT); SI.Temperature[n] Ta(each start=T_start-0.5*dT);