# Sample Rejection & Recollection When a sample is unfit for analysis, the laboratory can reject it and — where appropriate — request that a fresh sample be collected from the patient. This article explains the rejection workflow, the recollection request process, and how to track and complete a recollection. --- ## Common Reasons for Rejection | Reason | Description | |---|---| | **Haemolysis** | Red blood cells have broken down, affecting biochemistry results | | **Insufficient volume** | Not enough sample to run all ordered tests | | **Wrong container** | Sample collected in the incorrect tube type (e.g., EDTA instead of plain) | | **Clotted blood** | Coagulation occurred in an anticoagulant tube | | **Delayed transit** | Sample arrived too late for the test's stability window | | **Unlabelled / mislabelled** | Sticker missing or belongs to a different patient | | **Lipemia** | Excessive fat in serum, interfering with certain assays | | **Contamination** | Sample contaminated during collection | --- ## Rejecting a Sample 1. Go to **Lab → Sample Management** or the **Laboratory Dashboard > Samples** tab. 2. Locate the investigation by scanning the container barcode or searching by patient name or bill number. 3. Click **Reject Sample**. 4. In the rejection dialog, choose one of two options: ### Option A: Request Recollection Select **Request Recollection** when the test must still be performed and a new sample can be obtained from the patient. - The investigation status moves to **Recollection Requested**. - A notification is sent to the collection point (phlebotomy area or collecting centre) indicating that this sample requires recollection. - The patient or collection staff will need to arrange a new sample. ### Option B: Reject Without Recollection Select **Reject Without Recollection** when the test will not be repeated (patient discharged, test no longer required, or clinician advised to cancel). - The investigation status moves to **Sample Rejected**. - No further action is expected in the system. - The ordering clinician should be informed manually if the test result is clinically urgent. 5. Enter a **rejection reason** in the comments field (recommended for audit purposes). 6. Click **Confirm**. --- ## Recollection Workflow Once recollection is requested, the following steps apply: ### At the Collection Point 1. The phlebotomist or collector sees the recollection request in **Lab → Sample Management** — investigations with status **Recollection Requested** are highlighted. 2. The patient is called back or informed to return for a repeat sample. 3. A **new barcode sticker** is printed for the replacement sample container. 4. The new sample is collected and the sticker attached. 5. The collector marks the sample as collected; the status moves to **Recollection Pending** or **Sample Collected** depending on configuration. ### At the Lab 1. The replacement sample arrives at the lab reception. 2. The technician scans the barcode and accepts the new sample. 3. The investigation status updates to **Sample Accepted** and the investigation rejoins the normal workflow. --- ## Tracking Rejected and Recollection Requests To view all pending recollection requests: 1. Go to **Lab → Sample Management** or the **Laboratory Dashboard**. 2. Filter by status **Recollection Requested** or **Recollection Pending**. 3. The list shows the patient name, investigation, original rejection reason, and rejection date/time. To view the complete rejection history for a specific investigation, open the investigation record. The system records each rejection with the technician's name, timestamp, and reason. --- ## Reverting a Rejection If a sample was rejected in error: 1. Find the investigation in the sample management screen. 2. Click **Revert** (only available to authorised users). 3. The investigation status returns to the previous state so it can be re-assessed and accepted. --- ## Cancelling a Sample Collection Once the laboratory has accepted a sample, its bill cannot be cancelled or refunded. If the bill must be cancelled (for example, the wrong test was billed or the patient left before the test was done), a laboratory user with the **Lab Revert Sample** privilege first cancels the sample collection. 1. Open the sample. You can do this from either screen: - **Laboratory Dashboard > Samples** tab - **Lab > Sample Management** 2. Tick the sample. 3. Enter the **Reason for cancelling sample collection**. 4. Click **Cancel Sample Collection** and confirm. **What this does:** - The sample goes back to **Barcode Generated**. Its collected, sent and received details are cleared. - Any draft (unapproved) results for the test are discarded. - The test no longer counts as accepted, so the bill can now be cancelled or refunded. - The action is recorded in the audit log, with the reason. **When it is refused:** - The report has already been **approved or printed**. - The sample was never collected. - No reason was entered. - You do not have the **Lab Revert Sample** privilege. The button stays disabled. > **Note:** If **all** samples of a test are rejected, the test no longer blocks cancellation. Its bill can then be cancelled or refunded without cancelling the sample collection. --- ## Tips and Best Practices - Always document the rejection reason — this data feeds into quality monitoring reports. - For urgent tests (e.g., stat electrolytes), escalate verbally to the clinical team immediately when rejecting, even if a recollection request is sent through the system. - Maintain a log of recollection turnaround times. Long delays between rejection and receipt of replacement sample may indicate a process issue at the collection point. - If the same investigation is repeatedly rejected for the same reason, inform the lab administrator — there may be a training or equipment issue at the collection point. --- [Back to LIMS](https://github.com/hmislk/hmis/wiki/LIMS)