HomeWizard gas values/sensors not available anymore #117557
Comments
Hey there @DCSBL, mind taking a look at this issue as it has been labeled with an integration ( Code owner commandsCode owners of
(message by CodeOwnersMention) homewizard documentation |
I see that also the "P1 meter energy import" and "P1 meter energy export" is not working the same as the "sensor.p1_meter_total_energy_export" and "sensor.p1_meter_total_energy_import" I had before... |
@vincentvdb1987 check if can reach your meters local api on |
I can reach it without issue and get this info: The P1 meter is also available in HA but I only get electricity and water values, no gas information |
@Willem-Dekker, I think you issue is #87432 @vincentvdb1987, can you see if you still have some old entities alive in your instance? Maybe you can (backup and) remove those. I suspect we do not handle unique ID's + migration properly (introduced in #100684) |
@DCSBL thanks for the reply. I checked and indeed some old entities were available, I deleted them and reloaded the integration but still no luck. Anything else I should do? |
Oh, I've just checked your diagnostic file. I see two things that may be concerning;
If you have discord, can you message me privately with the result of |
I had the same thought that they fkd up but in the diagnostics file I see this: So it looks to me like there is something available? I am not using discord so I paste the info here, no idea if there is anything sensitive? :-D /FLU5\253967035_D 0-0:96.1.4(50221) |
Your gasmeter and watermeter both have the EAN Because we use this value as So we have to figure out if this is something we could/should fix is to determine if this is new behaviour from Fluvius or just one installer that had pressed the wrong button or something. Can you get in contact with Fluvius? Just send them the telegram and tell them |
I called with Fluvius, apparently they have some issues "in transition" where a lot of EAN numbers got locked, that's why I get all 0. They are working on but it can take some months :-| |
Okay, bummer! Having one that is unique should do the trick indeed. (Maybe you have to remove the 'old' 000-watermeter first.) It may be possible to add something to fix this issue (temporary) as this may cause issues with more customers in the near-future. We may create an unique_id based on the smart meter EAN + 'It is a gasmeter', that combo is pretty unique in most cases 🤞. I will ping the core developers to join the discussion. |
That would be indeed a good workaround since I don't believe that the water-people are smart enough to program a serial number in that thing :-s EAN+'it is a gasmeter' should indeed be unique in most households, unless in apartment or business buildings with multiple devices where the owner wants to control everything :-) |
Proposed a fix in #117940 |
Nice! Thanks a lot!!! |
@vincentvdb1987 as beta week is coming close I think it is the best to wait for that. Otherwise you have to set up a development environment. Besides this, can we add you to a firmware beta? We have developed a fix which should solve this issue. If so please fill in this form and I will add your P1 Meter to the beta channel. |
I wanted to let you know that I installed 2024.6.0 and the problem is solved now! All devices (gas, electricity, water) are available again! I removed everything because the entities names where a bit messed up (gas meter was named as water etc) but after adding again everything looks perfect! Thanks a lot for the quick effort! |
Great to hear! Thanks for the feedback 👊 |
The problem
Few days ago my digital gas and electricity devices were replaced with new onces since the previous stopped communicating. Since then I don't get the GAS information anymore from my HomeWizard P1 meter.
I tried removing the integration, restarted HA and add again but still the same. I also restarted the P1 meter multiple times. The gas values are still available in the diagnostics file but I don't have any sensor available in HA. Previously the integration showed 3 devices (P1 electricity, Gas, Water), now only P1 and water.
What version of Home Assistant Core has the issue?
2024.5.3
What was the last working version of Home Assistant Core?
No response
What type of installation are you running?
Home Assistant OS
Integration causing the issue
HomeWizard
Link to integration documentation on our website
No response
Diagnostics information
config_entry-homewizard-faeaed9652a01d5fe687706c2b3b051d (2).json
Example YAML snippet
No response
Anything in the logs that might be useful for us?
Additional information
No response
The text was updated successfully, but these errors were encountered: