Fix fritzbox climate HVAC mode / temperature #25275

Merged
merged 4 commits into from Jul 19, 2019
Merged
Changes from 1 commit
Commits
File filter...
Filter file types
Jump to…
Jump to file or symbol
Failed to load files and symbols.

Always

Just for now

Update tests

  • Loading branch information...
cgtobi committed Jul 19, 2019
commit 1cc1ba990ba42b0ed2cc272175835d8113c5093d
@@ -111,7 +111,10 @@ def set_temperature(self, **kwargs):
@property
def hvac_mode(self):
"""Return the current operation mode."""
if self._target_temperature == OFF_REPORT_SET_TEMPERATURE:
if (
self._target_temperature == OFF_REPORT_SET_TEMPERATURE or
self._target_temperature == OFF_API_TEMPERATURE
):
return HVAC_MODE_OFF

return HVAC_MODE_HEAT
@@ -103,7 +103,7 @@ def test_hvac_mode(self):
self.thermostat._target_temperature = 127.0
assert 'heat' == self.thermostat.hvac_mode
self.thermostat._target_temperature = 126.5
assert 'heat' == self.thermostat.hvac_mode
assert 'off' == self.thermostat.hvac_mode
self.thermostat._target_temperature = 22.0
assert 'heat' == self.thermostat.hvac_mode
self.thermostat._target_temperature = 16.0
ProTip! Use n and p to navigate between commits in a pull request.