SharpXR is a dual-decoder U-Net for denoising low-dose pediatric chest X-rays while preserving diagnostically relevant structure. This repo contains the implementation, training and evaluation scripts used in our MIRASOL, MICCAI 2025 work.
SharpXR: Structure-Aware Denoising for Pediatric Chest X-Rays
Code: https://github.com/ileri-oluwa-kiiye/SharpXR
- Dual-decoder U-Net: one decoder for noise suppression, one Laplacian-enhanced decoder for edge preservation.
- Learnable fusion: pixel-wise attention weights balance smoothness vs. structure.
- Realistic noise simulation: hybrid Poisson–Gaussian model for low-dose conditions.
- Comprehensive benchmarks: BM3D, DnCNN, REDCNN, ResUNet++, Attention U-Net, Sharp U-Net, Hformer.
- Downstream utility: boosts pneumonia classification accuracy (88.8% → 92.5%).
├── checkpoints/ # Pretrained weights / saved states
├── config/ # YAML/JSON configs (training, eval, paths, noise)
├── data/ # Datasets & loaders
├── evaluation/ # Metrics (RMSE, PSNR, SSIM, SNR) + scripts
├── models/ # SharpXR modules and baselines
├── training/ # Trainer, loops, logging
├── utils/ # Preprocessing, augmentation, misc helpers
├── main.py # Entry point (train/eval)
└── README.md
git clone https://github.com/ileri-oluwa-kiiye/SharpXR.git
cd SharpXR
pip install -r requirements.txt
Requires: Python 3.8+, PyTorch, torchvision, numpy, scikit-image, tqdm.
We use the Pediatric Pneumonia Chest X-ray dataset (Kermany et al., 2018):
https://www.kaggle.com/datasets/andrewmvd/pediatric-pneumonia-chest-xray
Preprocessing:
- Resize to 256×256, normalize to [0,1].
- Split: 75% train / 10% val / 15% test (stratified).
- Augment: horizontal flip (p=0.5), ±10% brightness/contrast, ±15° rotation.
Configure dataset paths in config/dataset.yaml.
Noise model (applied to training inputs)
Poisson–Gaussian:
[
\tilde{X} = \frac{1}{\eta},\mathrm{Poisson}(\eta X) + \mathcal{N}(0,\sigma^2),;
\eta \in [50,300],; \sigma \in [5,30]
]
python main.py --config config/train.yaml
python main.py --config config/eval.yaml --checkpoint checkpoints/sharpxr_best.pth
RMSE, PSNR, SSIM, SNR (logged to evaluation/).
Overall benchmark on pediatric chest X-rays (lower RMSE is better; higher PSNR/SSIM/SNR is better).
| Model | RMSE ↓ | PSNR ↑ | SSIM ↑ | SNR ↑ |
|---|---|---|---|---|
| BM3D | 0.0346 | 29.45 | 0.7003 | 22.85 |
| DnCNN | 0.0203 | 33.97 | 0.8945 | 28.29 |
| REDCNN | 0.0181 | 34.95 | 0.9140 | 29.20 |
| Sharp U-Net | 0.0172 | 35.40 | 0.9261 | 29.72 |
| SharpXR | 0.0170 | 35.52 | 0.9263 | 29.84 |
Downstream classification
Using SharpXR-denoised images improves pneumonia classification accuracy from 88.8% → 92.5% (clean: 93.7%).
Qualitative examples
See evaluation/qualitative_results/ for ROI crops highlighting rib and lung boundary preservation.
- Optimizer: Adam (lr=1e-4), batch size=4, epochs=50.
- Fixed random seeds in training scripts for determinism (subject to CUDA/cuDNN).
If this repository helps your research, please cite:
@inproceedings{abolade2025sharpxr,
title = {SharpXR: Structure-Aware Denoising for Pediatric Chest X-Rays},
author = {Abolade, Ilerioluwakiiye and Idoko, Emmanuel and Odelola, Solomon and Omoigui, Promise and Adebanwo, Adetola and Iorumbur, Aondana and Anazodo, Udunna and Crimi, Alessandro and Confidence, Raymond},
booktitle = {Medical Image Computing and Computer-Assisted Intervention (MICCAI)},
year = {2025}
}
We thank ML Collective for compute and weekly feedback, and AFRICAI for mentorship.
Supported in part by the Italian Ministry of University and Research (MUR), project PE0000013 – FAIR.