Linux Bash script that reports the Write Amplification Factor (WAF) of a workload over a defined period and estimates the Drive Life in years of a new drive under this workload.
endurance_profiler.sh - Extracting Write Amplification Factor (WAF) on Intel PCIe/NVMe based SSDs.
endurance_profiler.sh [options]
start
Starts the endurance_profiler service. It will log all the required Vendor Unique Smart Attributes to calculate the Write Amplification Factor.
When endurance_profiler.sh start is called it will complete immediately and a background process will keep running until endurance_profiler.sh stop is called.
The status of the service can be checked with the option status.
Start will fail if no NVMe device is set with setDevice option.
stop
Stops the endurance_profiler service and stop logging the Vendor Unique Smart Attributes.
restart
Stops and restarts the endurance_profiler service.
status
Returns the status of the service. The status can be running or not running.
resetWorkloadTimer
Resets the workload timer.
WAFinfo
Prints the Write Amplification Factor (WAF) and other information for the NVMe SSD.
setDevice nvmeXnX
Sets the NVMe device to be monitored.
This option has one mandatory parameter: the nvme device e.g. nvme1n1
The option is required before the service can be started.
- Ubuntu 18.04, 20.04
- CentOS 7, CentOS 8
Calling the script without a parameter will result in printing the supported options.
# ./endurance_profiler.sh
[start|stop|restart|status|resetWorkloadTimer|WAFinfo|setDevice]
Check the status of the service:
# ./endurance_profiler.sh status
[STATUS] Service ./endurance_profiler.sh not running
Set the NVMe device to be monitored:
# ./endurance_profiler.sh setDevice nvme1n1
[CHECKNVMENAMESPACE] nvme device nvme1n1 exists
[SETDEVICE] Device set to nvme1n1
Start the service:
# ./endurance_profiler.sh start
[START] Starting ./endurance_profiler.sh
[START} /var/log/endurance_profiler/endurance_profiler.nvmenamespace.var exists and device=nvme1n1
[CHECKNVMENAMESPACE] nvme device nvme1n1 exists
[START] Logging on nvme1n1. Log filename /var/log/endurance_profiler/endurance_profiler.log
[START] ./endurance_profiler.sh has pid=7936
[STATUS] Service ./endurance_profiler.sh with pid=7936 running
Check the status of the service:
# ./endurance_profiler.sh status
[STATUS] Service ./endurance_profiler.sh with pid=7936 running
It is suggested to run a workload for longer than 1 hour.
Check the Write Amplification Info:
# ./endurance_profiler.sh WAFinfo
Drive : Intel(R) SSD DC P5316 Series 15362GB
Serial number : PHAC121300TN15PHGN
Device : /dev/nvme3n1
smart.write_amplification_factor : 2.34
smart.media_wear_percentage : 0.030%
smart.host_reads : 81%
smart.timed_work_load : 653 minutes
Drive life : 4.007 years (2106451 minutes)
Stop the service:
# ./endurance_profiler.sh stop
[STOP] Stopping ./endurance_profiler.sh with pid=7936
[STOP] kill 7936
Check the status:
# ./endurance_profiler.sh status
[STATUS] Service ./endurance_profiler.sh not running
The following variables in the ./endurance_profiler.sh script are configurable.
_db=console
_nc_graphite_destination=localhost
_nc_graphite_port=2003
_db
The variable indicates if and where the evaluated SMART attributes and bandwidth will be logged.
Logging is not required to get the Write Amplification Factor through the WAFinfo option.
- supported values: graphite, logfile, console
- default: console
The following SMART attributes are evaluated:
- media_wear_percentage
- host_reads
- timed_work_load
- write_amplicifation_factor
- host_bytes_written
- temperature
- percentage_used
The following bandwidth metrics are evaluated:
- readBW
- writeBW
_nc_graphite_destination
This variable will be used as destination address when _db=graphite.
The destination address can be localhost or a remote IP address.
- supported values: all IP addresses
- default: localhost
_nc_graphite_port
This variable will be used as destination port when _db=graphite.
The destination port can be any IP port.
- supported values: all IP ports
- default: 2003