Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Confusing error message for StrictErrorHandler #563

Closed
jasminas opened this issue Feb 16, 2017 · 1 comment
Closed

Confusing error message for StrictErrorHandler #563

jasminas opened this issue Feb 16, 2017 · 1 comment

Comments

@jasminas
Copy link

@jasminas jasminas commented Feb 16, 2017

I am trying to validate DSTU2 RI Structures using a RequestValidatingInterceptor with custom structure definitions (I am also encountering #552, so the validation is still made against the base profiles).
After setting the parser error handler to StrictErrorHandler I'm trying to post the following resource:
{ "resourceType": "Observation", "identifier": [{ "use": "usual", "type": { "coding": [{ "system": "http://hl7.org/fhir/v2/0203", "code": "MR" }] }, "system": "urn:oid:1.2.36.146.595.217.0.1", "value": "12345", "period": { "start": "2001-05-06" }, "assigner": { "display": "Acme Healthcare" } }], "status": "final", "category": { "coding": [{ "system": "http://hl7.org/fhir/observation-category", "version": "Version 1", "code": "social-history", "display": "social-history", "userSelected": false }], "text": "Some text for CodeableConcept" }, "code": { "coding": [{ "system": "http://loinc.org", "code": "55284-4", "display": "Blood pressure systolic & diastolic" }] }, "subject": { "reference": "Patient/1", "display": "Patient 1" }, "encounter": "Encounter/1", "specimen": "Specimen/1", "device": "Device/1", "effectiveDateTime": "2012-09-17", "issued": "2013-04-04T14:34:00+01:00", "performer": [{ "reference": "Patient/1" }], "valueQuantity": { "value": "222", "comparator": "<", "unit": "m", "system": "http://loinc.org", "code": "222m" }, "dataAbsentReason": { "coding": [{ "system": "http://hl7.org/fhir/data-absent-reason", "code": "not-asked", "display": "Not Asked" }] }, "interpretation": { "coding": [{ "system": "http://hl7.org/fhir/v2/0078", "code": "L", "display": "Below low normal" }], "text": "low" }, "comments": "Comments", "bodySite": { "coding": [{ "system": "http://snomed.info/sct", "code": "368209003", "display": "Right arm" }] }, "method": { "coding": [{ "system": "http://hl7.org/fhir/v3/ObservationMethod", "version": "Version 1", "code": "ALGM", "display": "algorithm", "userSelected": false }], "text": "Some text for CodeableConcept" }, "referenceRange": [{ "low": { "value": 3.1, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" }, "high": { "value": 6.2, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" }, "meaning": { "coding": [{ "system": "http://hl7.org/fhir/referencerange-meaning", "version": "Version 1", "code": "type", "display": "type", "userSelected": false }], "text": "Some text for CodeableConcept" }, "age": { "low": { "value": 3, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" }, "high": { "value": 6, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" } }, "text": "Some text" }], "related": { "type": "has-member", "target": "Observation/1" }, "component": [{ "code": { "coding": [{ "system": "http://loinc.org", "code": "1-8", "display": "Systolic blood pressure" }, { "system": "http://snomed.info/sct", "code": "10-9", "display": "Systolic blood pressure" }, { "system": "http://acme.org/devices/clinical-codes", "code": "100-8", "display": "Systolic Blood pressure" }] }, "valueQuantity": { "value": 107, "unit": "mm[Hg]" } }, { "code": { "coding": [{ "system": "http://loinc.org", "code": "1-8", "display": "Systolic blood pressure" }] }, "valueQuantity": { "value": "222", "comparator": "<", "unit": "mm[Hg]", "system": "http://loinc.org", "code": "222m" } }] }

...receiving the following error message:
{ "severity": "error", "code": "processing", "diagnostics": "Failed to parse request body as JSON resource. Error was: Unknown attribute 'value' found during parse" }

The hardcoded 'value' hint is misleading. It should actually be pointing to one of the 'encounter', 'specimen', 'device' attributes which are having the wrong format for a reference field.

@jamesagnew
Copy link
Owner

@jamesagnew jamesagnew commented May 15, 2017

Thanks for reporting! Checking in a fix shortly.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Linked pull requests

Successfully merging a pull request may close this issue.

None yet
2 participants
You can’t perform that action at this time.