Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

Already on GitHub? Sign in to your account

Incorrect trigger position using original SUMP logic #116

Open
jawi opened this Issue Sep 9, 2012 · 0 comments

Comments

Projects
None yet
1 participant
Owner

jawi commented Sep 9, 2012

When i used the OLS, with original sump logic:

Recording Size 128K, Trigger ratio 50/50, worked correctly.
Recording Size 256K, Trigger ratio 50/50, worked incorrectly, there was no pretrigger data showed. I captured the wrong command using LA.

128K, Trigger ratio 50/50, Set Read & Delay Count command was 0x81 0xFF 0x7F 0x00 0x40, while
256K, Trigger ratio 50/50, Set Read & Delay Count command was 0x81 0xFF 0xFF 0xFF 0xFF, it should be 0x81 0xFF 0xFF 0xFF 0x7F.

(reported by alexli)

@ghost ghost assigned jawi Sep 9, 2012

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment