[s6-init] making user provided files available at /var/run/s6/etc...exited 0. [s6-init] ensuring user provided files have correct perms...exited 0. [fix-attrs.d] applying ownership & permissions fixes... [fix-attrs.d] done. [cont-init.d] executing container initialization scripts... [cont-init.d] done. [services.d] starting services [services.d] done. [21:09:32] INFO: Starting xcomfortd version 0.2 (alpha) 2020/05/05 21:09:32 Dp 2: device Dimming Actuator (CDAx-01/xx), serial 5740117, channel 0, '1.etg sov 4' 2020/05/05 21:09:32 Dp 3: device Dimming Actuator (CDAx-01/xx), serial 5734031, channel 0, '1.etg sov 3' 2020/05/05 21:09:32 Dp 4: device Dimming Actuator (CDAx-01/xx), serial 5740097, channel 0, '1.etg sov 2' 2020/05/05 21:09:32 Dp 5: device Dimming Actuator (CDAx-01/xx), serial 5733990, channel 0, '1.etg sov.1' 2020/05/05 21:09:32 Dp 6: device Dimming Actuator (CDAx-01/xx), serial 5736891, channel 0, '1.etg bad speil' 2020/05/05 21:09:32 Dp 7: device Dimming Actuator (CDAx-01/xx), serial 5736925, channel 0, '1.etg bad tak' 2020/05/05 21:09:32 Dp 8: device Dimming Actuator (CDAx-01/xx), serial 5734000, channel 0, '1.etg stor gang' 2020/05/05 21:09:32 Dp 10: device Dimming Actuator (CDAx-01/xx), serial 5733992, channel 0, '1.etg tv stue' 2020/05/05 21:09:32 Dp 11: device Dimming Actuator (CDAx-01/xx), serial 5734068, channel 0, '1.etg liten gang' 2020/05/05 21:09:32 Dp 13: device Dimming Actuator (CDAx-01/xx), serial 5741956, channel 0, '1.etg stue lampe spi' 2020/05/05 21:09:32 Dp 14: device Switching Actuator (CSAx-01/xx), serial 5733605, channel 0, 'utelys terrasse' 2020/05/05 21:09:32 Dp 16: device Switching Actuator (CSAx-01/xx), serial 5727387, channel 0, '1.etg bad vk' 2020/05/05 21:09:32 Dp 17: device Switching Actuator (CSAx-01/xx), serial 5727252, channel 0, 'utelys hovedd�r' 2020/05/05 21:09:32 Dp 18: device Switching Actuator (CSAx-01/xx), serial 5709360, channel 0, 'bakd�r utelys' 2020/05/05 21:09:32 Dp 19: device Dimming Actuator (CDAx-01/xx), serial 5734274, channel 0, '1.etg kj�kken spotter' 2020/05/05 21:09:32 Dp 20: device Switching Actuator (CSAx-01/xx), serial 5727267, channel 0, '1.etg dusj/bad vk' 2020/05/05 21:09:32 Dp 22: device Switching Actuator (CSAx-01/xx), serial 5733608, channel 0, '1.etg liten gang vk' 2020/05/05 21:09:32 Dp 24: device Switching Actuator (CSAx-01/xx), serial 5733583, channel 0, '1.etg stor gang vk' 2020/05/05 21:09:32 Dp 25: device Dimming Actuator (CDAx-01/xx), serial 5740172, channel 0, '1.etg dusj/bad' 2020/05/05 21:09:32 Dp 26: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879411, channel 0, 'Utelys_leil (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 27: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882335, channel 0, 'hybel stue tak (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 28: device Dimming Actuator New Generation (CDAx-01/xx), serial 6881943, channel 0, 'hybel kj�kken tak (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 29: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879566, channel 0, 'hybel sov tak (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 30: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6736735, channel 0, 'hybel bad vk (Aktuator)' 2020/05/05 21:09:32 Dp 31: device Dimming Actuator New Generation (CDAx-01/xx), serial 6924775, channel 0, 'hybel bad tak (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 34: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882567, channel 0, 'kjeller vaskerom tak (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 35: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6927276, channel 0, 'kjeller vaskerom vk (Aktuator)' 2020/05/05 21:09:32 Dp 38: device Dimming Actuator New Generation (CDAx-01/xx), serial 6881934, channel 0, 'kjeller trappegang (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 39: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6789326, channel 0, 'kjeller inngang vk (Aktuator)' 2020/05/05 21:09:32 Dp 40: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882130, channel 0, 'kjeller inngang (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 41: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6788682, channel 0, 'kjeller vk.bad (Aktuator)' 2020/05/05 21:09:32 Dp 44: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882123, channel 0, 'kjeller bad taklys (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 45: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882540, channel 0, 'kjeller bad overlys (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 48: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882412, channel 0, 'kjeller gang1 (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 49: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882008, channel 0, 'kjeller tvstue 2 (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 50: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879924, channel 0, 'kjeller tvstue (Dimmeaktuator)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879411, channel 0, 'Utelys_leil (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882335, channel 0, 'hybel stue tak (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6881943, channel 0, 'hybel kj�kken tak (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879566, channel 0, 'hybel sov tak (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6736735, channel 0, 'hybel bad vk (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6924775, channel 0, 'hybel bad tak (Statusforbindelse)' 2020/05/05 21:09:32 Dp 32: device Room Controller Touch (CRCA-00/xx), serial 7417943, channel 4, 'hybel bad temp (Touch-sensor A)' 2020/05/05 21:09:32 Dp 33: device Room Controller Touch (CRCA-00/xx), serial 7417943, channel 5, 'hybel bad temp (Touch-sensor B)' 2020/05/05 21:09:32 Dp 60: device Room Controller Touch (CRCA-00/xx), serial 7417943, channel 0, 'hybel bad temp (Temperatur)' 2020/05/05 21:09:32 Dp 61: device Room Controller Touch (CRCA-00/xx), serial 7417943, channel 1, 'hybel bad temp (Fuktighet)' 2020/05/05 21:09:32 Dp 64: device Room Controller Touch (CRCA-00/xx), serial 7417943, channel 6, 'hybel bad temp (ekstern Sensor (PT1000))' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882567, channel 0, 'kjeller vaskerom tak (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6927276, channel 0, 'kjeller vaskerom vk (Statusforbindelse)' 2020/05/05 21:09:32 Dp 36: device Room Controller Touch (CRCA-00/xx), serial 6807667, channel 4, 'kjeller vaskerom temp (Touch-sensor A)' 2020/05/05 21:09:32 Dp 37: device Room Controller Touch (CRCA-00/xx), serial 6807667, channel 5, 'kjeller vaskerom temp (Touch-sensor B)' 2020/05/05 21:09:32 Dp 58: device Room Controller Touch (CRCA-00/xx), serial 6807667, channel 0, 'kjeller vaskerom temp (Temperatur)' 2020/05/05 21:09:32 Dp 59: device Room Controller Touch (CRCA-00/xx), serial 6807667, channel 1, 'kjeller vaskerom temp (Fuktighet)' 2020/05/05 21:09:32 Dp 62: device Room Controller Touch (CRCA-00/xx), serial 6807667, channel 6, 'kjeller vaskerom temp (ekstern Sensor (PT1000))' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6881934, channel 0, 'kjeller trappegang (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6788682, channel 0, 'kjeller vk.bad (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882123, channel 0, 'kjeller bad taklys (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882540, channel 0, 'kjeller bad overlys (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882412, channel 0, 'kjeller gang1 (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882008, channel 0, 'kjeller tvstue 2 (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6879924, channel 0, 'kjeller tvstue (Statusforbindelse)' 2020/05/05 21:09:32 Dp 23: device Temperature Input (CTEU-02/xx), serial 5881353, channel 1, '1.etg liten gang temp (Kanal B)' 2020/05/05 21:09:32 Dp 15: device Temperature Input (CTEU-02/xx), serial 5881341, channel 1, '1.etg stor gang temp (Kanal A)' 2020/05/05 21:09:32 Dp 21: device Temperature Input (CTEU-02/xx), serial 5881271, channel 1, '1.etg bad temp (Kanal A)' 2020/05/05 21:09:32 Dp 51: device Room Controller Touch (CRCA-00/xx), serial 6809944, channel 6, 'kjeller bad temp (ekstern Sensor (PT1000))' 2020/05/05 21:09:32 Dp 52: device Room Controller Touch (CRCA-00/xx), serial 6809944, channel 0, 'kjeller bad temp (Temperatur)' 2020/05/05 21:09:32 Dp 53: device Room Controller Touch (CRCA-00/xx), serial 6809944, channel 1, 'kjeller bad temp (Fuktighet)' 2020/05/05 21:09:32 Dp 46: device Room Controller Touch (CRCA-00/xx), serial 6809944, channel 4, 'kjeller bad temp (Touch-sensor A)' 2020/05/05 21:09:32 Dp 47: device Room Controller Touch (CRCA-00/xx), serial 6809944, channel 5, 'kjeller bad temp (Touch-sensor B)' 2020/05/05 21:09:32 Dp 1: device Room Controller Touch (CRCA-00/xx), serial 6784078, channel 0, '1.etg dusj/bad (Temperatur)' 2020/05/05 21:09:32 Dp 9: device Room Controller Touch (CRCA-00/xx), serial 6784078, channel 1, '1.etg dusj/bad (Fuktighet)' 2020/05/05 21:09:32 Dp 12: device Room Controller Touch (CRCA-00/xx), serial 6784078, channel 6, '1.etg dusj/bad (ekstern Sensor (PT1000))' 2020/05/05 21:09:32 Dp 56: device Room Controller Touch (CRCA-00/xx), serial 6784078, channel 4, '1.etg dusj/bad (Touch-sensor A)' 2020/05/05 21:09:32 Dp 57: device Room Controller Touch (CRCA-00/xx), serial 6784078, channel 5, '1.etg dusj/bad (Touch-sensor B)' 2020/05/05 21:09:32 Dp 0: device Switching Actuator New Generation (CSAU-01/01-1xxx), serial 6789326, channel 0, 'kjeller inngang vk (Statusforbindelse)' 2020/05/05 21:09:32 Dp 0: device Dimming Actuator New Generation (CDAx-01/xx), serial 6882130, channel 0, 'kjeller inngang (Statusforbindelse)' 2020/05/05 21:09:32 Dp 54: device Room Controller Touch (CRCA-00/xx), serial 6783968, channel 0, 'kjeller inngang temp (Temperatur)' 2020/05/05 21:09:32 Dp 55: device Room Controller Touch (CRCA-00/xx), serial 6783968, channel 1, 'kjeller inngang temp (Fuktighet)' 2020/05/05 21:09:32 Dp 63: device Room Controller Touch (CRCA-00/xx), serial 6783968, channel 6, 'kjeller inngang temp (ekstern Sensor (PT1000))' 2020/05/05 21:09:32 Dp 42: device Room Controller Touch (CRCA-00/xx), serial 6783968, channel 4, 'kjeller inngang temp (Touch-sensor A)' 2020/05/05 21:09:32 Dp 43: device Room Controller Touch (CRCA-00/xx), serial 6783968, channel 5, 'kjeller inngang temp (Touch-sensor B)' 2020/05/05 21:09:32 Connecting to MQTT broker 'tcp://core-mosquitto:1883' with id 'xcomfort' 2020/05/05 21:09:32 Connected to broker 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5727267_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879411_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879411_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882130_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882130_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5733990_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5734000_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5741956_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6736735_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6736735_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881341_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6783968_battery/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6783968_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5734031_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5727252_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5740172_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_7417943_battery/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_7417943_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881353_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5740117_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5727387_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882123_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882123_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6789326_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6789326_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882412_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882412_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5736891_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5734068_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6927276_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6927276_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882335_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882335_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879924_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879924_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6807667_battery/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6807667_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6809944_battery/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6809944_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5709360_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5734274_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5733583_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5736925_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5733605_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879566_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6879566_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882008_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882008_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5740097_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6924775_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6924775_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6881934_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6881934_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882567_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882567_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6788682_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6788682_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882540_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6882540_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881271_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6784078_battery/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6784078_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5733992_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5733608_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6881943_internal_temperature/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6881943_rssi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881341_1_etg_stor_gang_temp_Kanal_A_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881271_1_etg_bad_temp_Kanal_A_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5734031_1_etg_sov_3/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5734000_1_etg_stor_gang/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5734068_1_etg_liten_gang/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5733583_1_etg_stor_gang_vk/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_A__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5709360_bakd_r_utelys/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6881934_kjeller_trappegang_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6784078_1_etg_dusj_bad_Temperatur_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6784078_1_etg_dusj_bad_ekstern_Sensor_PT1000_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5740172_1_etg_dusj_bad/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_7417943_hybel_bad_temp_ekstern_Sensor_PT1000_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6807667_kjeller_vaskerom_temp_ekstern_Sensor_PT1000_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5736925_1_etg_bad_tak/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5727267_1_etg_dusj_bad_vk/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_A__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5733605_utelys_terrasse/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882130_kjeller_inngang_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6807667_kjeller_vaskerom_temp_Temperatur_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5733990_1_etg_sov_1/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5733992_1_etg_tv_stue/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6736735_hybel_bad_vk_Aktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882540_kjeller_bad_overlys_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5727387_1_etg_bad_vk/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6881943_hybel_kj_kken_tak_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6784078_1_etg_dusj_bad_Touch_sensor_B__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_5881353_1_etg_liten_gang_temp_Kanal_B_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_B__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6783968_kjeller_inngang_temp_Temperatur_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6879411_Utelys_leil_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882335_hybel_stue_tak_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6924775_hybel_bad_tak_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6879924_kjeller_tvstue_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_7417943_hybel_bad_temp_Touch_sensor_B__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_A__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5727252_utelys_hovedd_r/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6789326_kjeller_inngang_vk_Aktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_7417943_hybel_bad_temp_Temperatur_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6783968_kjeller_inngang_temp_ekstern_Sensor_PT1000_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6879566_hybel_sov_tak_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6927276_kjeller_vaskerom_vk_Aktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_A__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6809944_kjeller_bad_temp_Temperatur_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6807667_kjeller_vaskerom_temp_Touch_sensor_B__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6809944_kjeller_bad_temp_Touch_sensor_A__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5740097_1_etg_sov_2/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5733608_1_etg_liten_gang_vk/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6788682_kjeller_vk_bad_Aktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882123_kjeller_bad_taklys_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5736891_1_etg_bad_speil/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5741956_1_etg_stue_lampe_spi/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5734274_1_etg_kj_kken_spotter/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__on/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__upPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__upReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__downPressed/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__downReleased/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/device_automation/xcomfort_6783968_kjeller_inngang_temp_Touch_sensor_B__off/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_5740117_1_etg_sov_4/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882567_kjeller_vaskerom_tak_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882412_kjeller_gang1_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/light/xcomfort_6882008_kjeller_tvstue_2_Dimmeaktuator_/config 2020/05/05 21:09:32 Sending HA discovery add message: homeassistant/sensor/xcomfort_6809944_kjeller_bad_temp_ekstern_Sensor_PT1000_/config 2020/05/05 21:09:32 Opened USB device 0 2020/05/05 21:09:32 CI HW/RF/FW revision: 0, 13.0, 0 2020/05/05 21:09:33 CI RF/Firmware release: 2.11, 2.05 2020/05/05 21:09:33 CI serial number: 7606894 2020/05/05 21:09:51 RX: [c10c620300011100002d240c] 2020/05/05 21:09:51 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/05 21:10:00 RX: [c1007339005fcb66004a04101a00000044100d] 2020/05/05 21:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/05 21:11:49 RX: [c13c62420010a9b9104a04101a00000044100da50ca500000046240f] 2020/05/05 21:11:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/05 21:11:49 Message not handled [c13c62420010a9b9104a04101a00000044100da50ca500000046240f] 2020/05/05 21:13:40 RX: [c137620400421533332d240a] 2020/05/05 21:13:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.3 2020/05/05 21:14:01 RX: [c13a62170000d200c13c2409] 2020/05/05 21:14:01 dropping wheel position on the ground: 19.3 2020/05/05 21:14:01 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/05 21:15:21 RX: [c13b620400423400003c240d] 2020/05/05 21:15:21 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 45 2020/05/05 21:15:41 RX: [c10c620300011200002d240d] 2020/05/05 21:15:41 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/05 21:19:10 RX: [c13c623f00b301b7002d240da500000044100da50ca5000000452400] 2020/05/05 21:19:10 (partially decoded) temp 18.3C moisture 43.5% 2020/05/05 21:19:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 21:19:10 Message not handled [c13c623f00b301b7002d240da500000044100da50ca5000000452400] 2020/05/05 21:19:20 RX: [c13c624200b3c52e102d240da500000044100da50ca5000000462401] 2020/05/05 21:19:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 21:19:20 Message not handled [c13c624200b3c52e102d240da500000044100da50ca5000000462401] 2020/05/05 21:20:41 RX: [c109620400421266662d2405] 2020/05/05 21:20:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.6 2020/05/05 21:24:01 RX: [c13e62030000f800003c240f] 2020/05/05 21:24:01 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/05 21:24:34 RX: [c11762030000d60000492504] 2020/05/05 21:24:34 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/05 21:25:35 RX: [c13c6242003a5f0f10492504a500000044100da50ca5000000462402] 2020/05/05 21:25:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 21:25:35 Message not handled [c13c6242003a5f0f10492504a500000044100da50ca5000000462402] 2020/05/05 21:25:43 RX: [c133620300ffff000036240c] 2020/05/05 21:25:43 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 21:26:20 RX: [c13662170000d900b52e2404] 2020/05/05 21:26:20 dropping wheel position on the ground: 18.1 2020/05/05 21:26:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.7 2020/05/05 21:28:11 RX: [c10162170000ee00de2d240e] 2020/05/05 21:28:11 dropping wheel position on the ground: 22.2 2020/05/05 21:28:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/05 21:31:43 RX: [c135620400425f999a362405] 2020/05/05 21:31:43 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.9 2020/05/05 21:31:50 RX: [c13c62420012d11f10362405a500000044100da50ca5000000462403] 2020/05/05 21:31:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 21:31:50 Message not handled [c13c62420012d11f10362405a500000044100da50ca5000000462403] 2020/05/05 21:32:23 RX: [c13462170000cb0000362406] 2020/05/05 21:32:23 dropping wheel position on the ground: 0.0 2020/05/05 21:32:23 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/05 21:35:01 RX: [c10f620300011700003b2503] 2020/05/05 21:35:01 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/05 21:35:19 RX: [c11562030001110000492508] 2020/05/05 21:35:19 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/05 21:36:31 RX: [c10c620300010b00002d240e] 2020/05/05 21:36:31 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/05 21:39:00 RX: [c13f62030000fa00002d240a] 2020/05/05 21:39:00 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/05 21:43:40 RX: [c1376204004215999a2d240b] 2020/05/05 21:43:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.4 2020/05/05 21:44:00 RX: [c13a62170000d100c13d240a] 2020/05/05 21:44:00 dropping wheel position on the ground: 19.3 2020/05/05 21:44:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.9 2020/05/05 21:45:20 RX: [c13b6204004234cccd3c240e] 2020/05/05 21:45:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 45.2 2020/05/05 21:46:31 RX: [c10c620300011000002e240f] 2020/05/05 21:46:31 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/05 21:49:20 RX: [c13c62420012635c102e240fa500000044100da50ca5000000462404] 2020/05/05 21:49:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 21:49:20 Message not handled [c13c62420012635c102e240fa500000044100da50ca5000000462404] 2020/05/05 21:50:41 RX: [c1096204004213999a2d2406] 2020/05/05 21:50:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.9 2020/05/05 21:54:00 RX: [c13e62030000f500003d2400] 2020/05/05 21:54:00 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/05 21:54:36 RX: [c11762030000d60000482506] 2020/05/05 21:54:36 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/05 21:55:35 RX: [c13c6242001aed4c10482506a500000044100da50ca5000000462405] 2020/05/05 21:55:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 21:55:35 Message not handled [c13c6242001aed4c10482506a500000044100da50ca5000000462405] 2020/05/05 21:55:43 RX: [c133620300ffff000035240d] 2020/05/05 21:55:43 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 21:56:20 RX: [c13662170000d600b52d2405] 2020/05/05 21:56:20 dropping wheel position on the ground: 18.1 2020/05/05 21:56:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.4 2020/05/05 21:57:20 RX: [c13e62030000fa00003d2401] 2020/05/05 21:57:20 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/05 21:58:11 RX: [c10162170000ed00de2d240f] 2020/05/05 21:58:11 dropping wheel position on the ground: 22.2 2020/05/05 21:58:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/05 21:59:40 RX: [c13f62030000f500002d240b] 2020/05/05 21:59:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/05 22:00:00 RX: [c1007339005fcb66004a04201900000044100e] 2020/05/05 22:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/05 22:01:43 RX: [c13562040042606666352406] 2020/05/05 22:01:43 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 56.1 2020/05/05 22:01:51 RX: [c13c62420012776d10352406a500000044100ea50ca5000000472406] 2020/05/05 22:01:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:01:51 Message not handled [c13c62420012776d10352406a500000044100ea50ca5000000472406] 2020/05/05 22:02:23 RX: [c13462170000cc0000362407] 2020/05/05 22:02:23 dropping wheel position on the ground: 0.0 2020/05/05 22:02:23 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/05 22:04:00 RX: [c13e62030000f500003c2402] 2020/05/05 22:04:00 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/05 22:05:03 RX: [c10f620300011400003b2505] 2020/05/05 22:05:03 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/05 22:05:21 RX: [c115620300010e000048250a] 2020/05/05 22:05:21 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/05 22:09:11 RX: [c13c623f00af01b60048250aa500000044100ea50ca5000000452407] 2020/05/05 22:09:11 (partially decoded) temp 18.2C moisture 43.1% 2020/05/05 22:09:11 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT OUT 2020/05/05 22:09:11 Message not handled [c13c623f00af01b60048250aa500000044100ea50ca5000000452407] 2020/05/05 22:09:22 RX: [c13c624200d21bfa1048250aa500000044100ea50ca5000000462408] 2020/05/05 22:09:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 22:09:22 Message not handled [c13c624200d21bfa1048250aa500000044100ea50ca5000000462408] 2020/05/05 22:09:40 RX: [c13f62030000f600002e240c] 2020/05/05 22:09:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/05 22:10:00 RX: [c1007339005fcb66004a04101a00000044100f] 2020/05/05 22:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/05 22:13:40 RX: [c137620400421666662d240c] 2020/05/05 22:13:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.6 2020/05/05 22:14:00 RX: [c13a62170000cf00c13d240b] 2020/05/05 22:14:00 dropping wheel position on the ground: 19.3 2020/05/05 22:14:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/05 22:15:20 RX: [c13b6204004231999a3d240f] 2020/05/05 22:15:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.4 2020/05/05 22:15:37 RX: [c13c6242001295ea103d240fa500000044100fa50ca5000000462409] 2020/05/05 22:15:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:15:37 Message not handled [c13c6242001295ea103d240fa500000044100fa50ca5000000462409] 2020/05/05 22:16:31 RX: [c10c620300010c00002d2400] 2020/05/05 22:16:31 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.8 2020/05/05 22:20:41 RX: [c109620400421333332d2407] 2020/05/05 22:20:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.8 2020/05/05 22:21:52 RX: [c13c624200120fcb102d2407a500000044100fa50ca500000046240a] 2020/05/05 22:21:52 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:21:52 Message not handled [c13c624200120fcb102d2407a500000044100fa50ca500000046240a] 2020/05/05 22:24:38 RX: [c11762030000d20000492508] 2020/05/05 22:24:38 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/05 22:25:20 RX: [c13e62030000f700003d2403] 2020/05/05 22:25:20 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/05 22:25:43 RX: [c133620300ffff000035240e] 2020/05/05 22:25:43 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 22:26:20 RX: [c13662170000d300b52d2406] 2020/05/05 22:26:20 dropping wheel position on the ground: 18.1 2020/05/05 22:26:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/05 22:26:31 RX: [c10c620300010500002d2401] 2020/05/05 22:26:31 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.1 2020/05/05 22:28:11 RX: [c10162170000ed00de2d2400] 2020/05/05 22:28:11 dropping wheel position on the ground: 22.2 2020/05/05 22:28:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/05 22:31:43 RX: [c13562040042600000352407] 2020/05/05 22:31:43 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 56 2020/05/05 22:32:23 RX: [c13462170000cb0000362408] 2020/05/05 22:32:23 dropping wheel position on the ground: 0.0 2020/05/05 22:32:23 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/05 22:35:05 RX: [c10f620300011400003b2507] 2020/05/05 22:35:05 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/05 22:35:23 RX: [c115620300010a000048250c] 2020/05/05 22:35:23 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.6 2020/05/05 22:39:22 RX: [c13c6242003281db1048250ca500000044100fa50ca500000045240b] 2020/05/05 22:39:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 22:39:22 Message not handled [c13c6242003281db1048250ca500000044100fa50ca500000045240b] 2020/05/05 22:39:40 RX: [c13f62030000f500002e240d] 2020/05/05 22:39:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/05 22:43:40 RX: [c137620400421733332e240d] 2020/05/05 22:43:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.8 2020/05/05 22:44:00 RX: [c13a62170000cd00c13d240c] 2020/05/05 22:44:00 dropping wheel position on the ground: 19.3 2020/05/05 22:44:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/05 22:45:20 RX: [c13b6204004231999a3d2400] 2020/05/05 22:45:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.4 2020/05/05 22:45:37 RX: [c13c624200123398103d2400a500000044100fa50ca500000046240c] 2020/05/05 22:45:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:45:37 Message not handled [c13c624200123398103d2400a500000044100fa50ca500000046240c] 2020/05/05 22:47:21 RX: [c10c620300010500002d2402] 2020/05/05 22:47:21 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.1 2020/05/05 22:50:41 RX: [c109620400421400002d2408] 2020/05/05 22:50:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37 2020/05/05 22:51:53 RX: [c13c62420012bd88102d2408a500000044100fa50ca500000045240d] 2020/05/05 22:51:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:51:53 Message not handled [c13c62420012bd88102d2408a500000044100fa50ca500000045240d] 2020/05/05 22:54:40 RX: [c11762030000d600004a250a] 2020/05/05 22:54:40 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/05 22:55:20 RX: [c13e62030000f400003c2404] 2020/05/05 22:55:20 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/05 22:55:40 RX: [c13f62030000f000002e240e] 2020/05/05 22:55:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/05 22:55:43 RX: [c133620300ffff000036240f] 2020/05/05 22:55:43 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 22:56:20 RX: [c13662170000d000b52e2407] 2020/05/05 22:56:20 dropping wheel position on the ground: 18.1 2020/05/05 22:56:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/05 22:58:11 RX: [c10162170000ec00de2e2401] 2020/05/05 22:58:11 dropping wheel position on the ground: 22.2 2020/05/05 22:58:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/05 22:59:13 RX: [c13c623f00ad01b6002e2401a500000044100fa50ca500000046240e] 2020/05/05 22:59:13 (partially decoded) temp 18.2C moisture 42.9% 2020/05/05 22:59:13 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 22:59:13 Message not handled [c13c623f00ad01b6002e2401a500000044100fa50ca500000046240e] 2020/05/05 22:59:23 RX: [c13c624200ada9b9102e2401a500000044100fa50ca500000046240f] 2020/05/05 22:59:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 22:59:23 Message not handled [c13c624200ada9b9102e2401a500000044100fa50ca500000046240f] 2020/05/05 23:00:00 RX: [c1007339005fcb66004a042019000000441000] 2020/05/05 23:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/05 23:01:43 RX: [c13562040042600000362408] 2020/05/05 23:01:43 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 56 2020/05/05 23:02:23 RX: [c13462170000cb0000362409] 2020/05/05 23:02:23 dropping wheel position on the ground: 0.0 2020/05/05 23:02:23 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/05 23:05:07 RX: [c10f620300011400003b2509] 2020/05/05 23:05:07 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/05 23:05:25 RX: [c115620300010a000049250e] 2020/05/05 23:05:25 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.6 2020/05/05 23:05:39 RX: [c13c624200064b3e1049250ea5000000441000a50ca5000000472400] 2020/05/05 23:05:39 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 23:05:39 Message not handled [c13c624200064b3e1049250ea5000000441000a50ca5000000472400] 2020/05/05 23:10:00 RX: [c1007339005fcb66004a04101a000000441001] 2020/05/05 23:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/05 23:10:20 RX: [c13f62030000f200002d240f] 2020/05/05 23:10:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/05 23:11:54 RX: [c13c62420012c52e102d240fa5000000441001a50ca5000000462401] 2020/05/05 23:11:54 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 23:11:54 Message not handled [c13c62420012c52e102d240fa5000000441001a50ca5000000462401] 2020/05/05 23:13:40 RX: [c1376204004218cccd2d240e] 2020/05/05 23:13:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.2 2020/05/05 23:14:00 RX: [c13a62170000cb00c13c240d] 2020/05/05 23:14:00 dropping wheel position on the ground: 19.3 2020/05/05 23:14:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/05 23:15:20 RX: [c13b620400423133333c2401] 2020/05/05 23:15:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.3 2020/05/05 23:17:21 RX: [c10c620300010200002e2403] 2020/05/05 23:17:21 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.8 2020/05/05 23:20:41 RX: [c1096204004215999a2d2409] 2020/05/05 23:20:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.4 2020/05/05 23:24:42 RX: [c11762030000d6000049250c] 2020/05/05 23:24:42 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/05 23:25:20 RX: [c13e62030000f700003c2405] 2020/05/05 23:25:20 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/05 23:25:43 RX: [c133620300ffff0000352400] 2020/05/05 23:25:43 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 23:26:20 RX: [c13662170000ce00b52e2408] 2020/05/05 23:26:20 dropping wheel position on the ground: 18.1 2020/05/05 23:26:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/05 23:26:34 RX: [c13c623f00ac01b5002e2408a5000000441001a50ca5000000462402] 2020/05/05 23:26:34 (partially decoded) temp 18.1C moisture 42.8% 2020/05/05 23:26:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 23:26:34 Message not handled [c13c623f00ac01b5002e2408a5000000441001a50ca5000000462402] 2020/05/05 23:27:00 RX: [c13f62030000ec00002d2400] 2020/05/05 23:27:00 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/05 23:28:11 RX: [c10162170000eb00de2d2402] 2020/05/05 23:28:11 dropping wheel position on the ground: 22.2 2020/05/05 23:28:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.5 2020/05/05 23:28:40 RX: [c13e62030000f200003d2406] 2020/05/05 23:28:40 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/05 23:29:14 RX: [c13c623f00ac01b5003d2406a5000000441001a50ca5000000462403] 2020/05/05 23:29:14 (partially decoded) temp 18.1C moisture 42.8% 2020/05/05 23:29:14 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 23:29:14 Message not handled [c13c623f00ac01b5003d2406a5000000441001a50ca5000000462403] 2020/05/05 23:29:24 RX: [c13c624200ac635c103d2406a5000000441001a50ca5000000462404] 2020/05/05 23:29:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 23:29:24 Message not handled [c13c624200ac635c103d2406a5000000441001a50ca5000000462404] 2020/05/05 23:30:20 RX: [c13f62030000f100002d2401] 2020/05/05 23:30:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.1 2020/05/05 23:31:43 RX: [c135620400425f999a362409] 2020/05/05 23:31:43 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.9 2020/05/05 23:32:23 RX: [c13462170000cb000037240a] 2020/05/05 23:32:23 dropping wheel position on the ground: 0.0 2020/05/05 23:32:23 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/05 23:35:09 RX: [c10f620300011000003b250b] 2020/05/05 23:35:09 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/05 23:35:27 RX: [c11562030001030000482500] 2020/05/05 23:35:27 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/05 23:35:39 RX: [c13c62420031ed4c10482500a5000000441001a50ca5000000462405] 2020/05/05 23:35:39 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 23:35:39 Message not handled [c13c62420031ed4c10482500a5000000441001a50ca5000000462405] 2020/05/05 23:41:40 RX: [c13f62030000ef00002e2402] 2020/05/05 23:41:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/05 23:41:55 RX: [c13c62420012776d102e2402a5000000441001a50ca5000000452406] 2020/05/05 23:41:55 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 23:41:55 Message not handled [c13c62420012776d102e2402a5000000441001a50ca5000000452406] 2020/05/05 23:43:40 RX: [c1376204004219999a2e240f] 2020/05/05 23:43:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.4 2020/05/05 23:44:00 RX: [c13a62170000ca00c13c240e] 2020/05/05 23:44:00 dropping wheel position on the ground: 19.3 2020/05/05 23:44:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/05 23:45:20 RX: [c13b620400423200003c2402] 2020/05/05 23:45:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.5 2020/05/05 23:47:21 RX: [c10c620300010400002d2404] 2020/05/05 23:47:21 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26 2020/05/05 23:48:35 RX: [c13c623f00ad01b5002d2404a5000000441001a50ca5000000472407] 2020/05/05 23:48:35 (partially decoded) temp 18.1C moisture 42.9% 2020/05/05 23:48:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 23:48:35 Message not handled [c13c623f00ad01b5002d2404a5000000441001a50ca5000000472407] 2020/05/05 23:49:15 RX: [c13c623f00ae01b5002d2404a5000000441001a50ca5000000452408] 2020/05/05 23:49:15 (partially decoded) temp 18.1C moisture 43.0% 2020/05/05 23:49:15 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/05 23:49:15 Message not handled [c13c623f00ae01b5002d2404a5000000441001a50ca5000000452408] 2020/05/05 23:49:25 RX: [c13c624200ae95ea102d2404a5000000441001a50ca5000000472409] 2020/05/05 23:49:25 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/05 23:49:25 Message not handled [c13c624200ae95ea102d2404a5000000441001a50ca5000000472409] 2020/05/05 23:50:41 RX: [c109620400421b999a2d240a] 2020/05/05 23:50:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.9 2020/05/05 23:54:44 RX: [c11762030000dd000049250e] 2020/05/05 23:54:44 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/05 23:55:40 RX: [c13c6242007e0fcb1049250ea5000000441001a50ca500000046240a] 2020/05/05 23:55:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/05 23:55:40 Message not handled [c13c6242007e0fcb1049250ea5000000441001a50ca500000046240a] 2020/05/05 23:55:42 RX: [c133620300ffff0000352401] 2020/05/05 23:55:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/05 23:56:00 RX: [c13e62030000f200003c2407] 2020/05/05 23:56:00 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/05 23:56:20 RX: [c13662170000cc00b52d2409] 2020/05/05 23:56:20 dropping wheel position on the ground: 18.1 2020/05/05 23:56:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/05 23:58:11 RX: [c10162170000ea00de2d2403] 2020/05/05 23:58:11 dropping wheel position on the ground: 22.2 2020/05/05 23:58:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/05 23:58:20 RX: [c13f62030000ea00002d2403] 2020/05/05 23:58:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 00:00:00 RX: [c1007339005fcb66004a042019000000441002] 2020/05/06 00:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 00:01:42 RX: [c135620400425e666635240a] 2020/05/06 00:01:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.6 2020/05/06 00:01:56 RX: [c13c6242001281db1035240aa5000000441002a50ca500000046240b] 2020/05/06 00:01:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 00:01:56 Message not handled [c13c6242001281db1035240aa5000000441002a50ca500000046240b] 2020/05/06 00:02:22 RX: [c13462170000ca000035240b] 2020/05/06 00:02:22 dropping wheel position on the ground: 0.0 2020/05/06 00:02:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 00:05:11 RX: [c10f620300011000003b250d] 2020/05/06 00:05:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 00:05:29 RX: [c11562030001030000482502] 2020/05/06 00:05:29 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/06 00:05:41 RX: [c10c62030000fd00002e2405] 2020/05/06 00:05:41 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 00:08:36 RX: [c13c623f00ac01b5002e2405a5000000441002a50ca500000044240c] 2020/05/06 00:08:36 (partially decoded) temp 18.1C moisture 42.8% 2020/05/06 00:08:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 00:08:36 Message not handled [c13c623f00ac01b5002e2405a5000000441002a50ca500000044240c] 2020/05/06 00:10:00 RX: [c1007339005fcb66004a04101a000000431003] 2020/05/06 00:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/06 00:12:20 RX: [c13f62030000ed00002e2404] 2020/05/06 00:12:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 00:13:16 RX: [c13c623f00ac01b5002e2404a5000000431003a50ca500000046240d] 2020/05/06 00:13:16 (partially decoded) temp 18.1C moisture 42.8% 2020/05/06 00:13:16 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 00:13:16 Message not handled [c13c623f00ac01b5002e2404a5000000431003a50ca500000046240d] 2020/05/06 00:13:40 RX: [c137620400421acccd2e2400] 2020/05/06 00:13:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.7 2020/05/06 00:14:00 RX: [c13a62170000c900c13c240f] 2020/05/06 00:14:00 dropping wheel position on the ground: 19.3 2020/05/06 00:14:00 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 00:15:20 RX: [c13b620400423266663c2403] 2020/05/06 00:15:20 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.6 2020/05/06 00:18:11 RX: [c10c62030000ff00002d2406] 2020/05/06 00:18:11 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 00:19:26 RX: [c13c6242001227a9102d2406a5000000431003a50ca500000046240e] 2020/05/06 00:19:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 00:19:26 Message not handled [c13c6242001227a9102d2406a5000000431003a50ca500000046240e] 2020/05/06 00:20:41 RX: [c109620400421a00002e240b] 2020/05/06 00:20:41 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.5 2020/05/06 00:24:46 RX: [c11762030000d60000492500] 2020/05/06 00:24:46 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 00:25:41 RX: [c13c6242007aa9b910492500a5000000431003a50ca500000046240f] 2020/05/06 00:25:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 00:25:41 Message not handled [c13c6242007aa9b910492500a5000000431003a50ca500000046240f] 2020/05/06 00:25:42 RX: [c133620300ffff0000352402] 2020/05/06 00:25:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 00:25:59 RX: [c13e62030000f200003c2408] 2020/05/06 00:25:59 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/06 00:26:20 RX: [c13662170000cb00b52e240a] 2020/05/06 00:26:20 dropping wheel position on the ground: 18.1 2020/05/06 00:26:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/06 00:28:11 RX: [c10162170000e900de2d2404] 2020/05/06 00:28:11 dropping wheel position on the ground: 22.2 2020/05/06 00:28:11 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 00:31:42 RX: [c135620400425ecccd37240b] 2020/05/06 00:31:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.7 2020/05/06 00:31:57 RX: [c13c624200124b3e1037240ba5000000431003a50ca5000000462400] 2020/05/06 00:31:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 00:31:57 Message not handled [c13c624200124b3e1037240ba5000000431003a50ca5000000462400] 2020/05/06 00:32:22 RX: [c13462170000cb000035240c] 2020/05/06 00:32:22 dropping wheel position on the ground: 0.0 2020/05/06 00:32:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/06 00:33:40 RX: [c13f62030000e800002d2405] 2020/05/06 00:33:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 00:35:13 RX: [c10f620300011000003b250f] 2020/05/06 00:35:13 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 00:35:31 RX: [c11562030001030000492504] 2020/05/06 00:35:31 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/06 00:39:17 RX: [c13c623f00e101b500492504a5000000431003a50ca5000000452401] 2020/05/06 00:39:17 (partially decoded) temp 18.1C moisture 48.1% 2020/05/06 00:39:17 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT OUT 2020/05/06 00:39:17 Message not handled [c13c623f00e101b500492504a5000000431003a50ca5000000452401] 2020/05/06 00:39:27 RX: [c13c624200b25f0f10492504a5000000431003a50ca5000000462402] 2020/05/06 00:39:27 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 00:39:27 Message not handled [c13c624200b25f0f10492504a5000000431003a50ca5000000462402] 2020/05/06 00:43:00 RX: [c13f62030000ea00002e2406] 2020/05/06 00:43:00 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 00:43:40 RX: [c137620400421c00002d2401] 2020/05/06 00:43:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39 2020/05/06 00:43:59 RX: [c13a62170000c800c13c2400] 2020/05/06 00:43:59 dropping wheel position on the ground: 19.3 2020/05/06 00:43:59 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 00:45:19 RX: [c13b620400422f33333c2404] 2020/05/06 00:45:19 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.8 2020/05/06 00:45:42 RX: [c13c62420012d11f103c2404a5000000431003a50ca5000000462403] 2020/05/06 00:45:42 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 00:45:42 Message not handled [c13c62420012d11f103c2404a5000000431003a50ca5000000462403] 2020/05/06 00:48:10 RX: [c10c62030000fd00002d2407] 2020/05/06 00:48:10 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 00:50:40 RX: [c1096204004219999a2d240c] 2020/05/06 00:50:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.4 2020/05/06 00:51:19 RX: [c13e62030000ec00003c2409] 2020/05/06 00:51:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/06 00:51:58 RX: [c13c62420012635c103c2409a5000000431003a50ca5000000472404] 2020/05/06 00:51:58 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 00:51:58 Message not handled [c13c62420012635c103c2409a5000000431003a50ca5000000472404] 2020/05/06 00:54:39 RX: [c13e62030000f200003c240a] 2020/05/06 00:54:39 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/06 00:54:48 RX: [c11762030000d60000492502] 2020/05/06 00:54:48 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 00:55:42 RX: [c133620300ffff0000352403] 2020/05/06 00:55:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 00:56:20 RX: [c13662170000c900b52d240b] 2020/05/06 00:56:20 dropping wheel position on the ground: 18.1 2020/05/06 00:56:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 00:56:51 RX: [c10f620300010900003b2501] 2020/05/06 00:56:51 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 00:57:19 RX: [c13e62030000f000003d240b] 2020/05/06 00:57:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/06 00:58:10 RX: [c10162170000e800de2e2405] 2020/05/06 00:58:10 dropping wheel position on the ground: 22.2 2020/05/06 00:58:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 01:00:00 RX: [c1007339005fcb66004a042019000000441004] 2020/05/06 01:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 01:01:42 RX: [c135620400425e000036240c] 2020/05/06 01:01:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.5 2020/05/06 01:02:22 RX: [c13462170000ca000036240d] 2020/05/06 01:02:22 dropping wheel position on the ground: 0.0 2020/05/06 01:02:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 01:05:33 RX: [c11562030000ff0000492506] 2020/05/06 01:05:33 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/06 01:09:27 RX: [c13c62420095ed4c10492506a5000000441004a50ca5000000452405] 2020/05/06 01:09:27 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 01:09:27 Message not handled [c13c62420095ed4c10492506a5000000441004a50ca5000000452405] 2020/05/06 01:10:01 RX: [c1007339005fcb66004a04101a000000441005] 2020/05/06 01:10:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 01:13:00 RX: [c13f62030000ea00002e2407] 2020/05/06 01:13:00 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 01:13:40 RX: [c137620400421c66662d2402] 2020/05/06 01:13:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.1 2020/05/06 01:13:59 RX: [c13a62170000c600c13c2401] 2020/05/06 01:13:59 dropping wheel position on the ground: 19.3 2020/05/06 01:13:59 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/06 01:15:19 RX: [c13b620400422ecccd3c2405] 2020/05/06 01:15:19 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.7 2020/05/06 01:15:43 RX: [c13c62420012776d103c2405a5000000441005a50ca5000000472406] 2020/05/06 01:15:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 01:15:43 Message not handled [c13c62420012776d103c2405a5000000441005a50ca5000000472406] 2020/05/06 01:18:10 RX: [c10c62030000fd00002e2408] 2020/05/06 01:18:10 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 01:20:40 RX: [c109620400421933332d240d] 2020/05/06 01:20:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.3 2020/05/06 01:21:59 RX: [c13c62420012f97d102d240da5000000441005a50ca5000000452407] 2020/05/06 01:21:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 01:21:59 Message not handled [c13c62420012f97d102d240da5000000441005a50ca5000000452407] 2020/05/06 01:24:50 RX: [c11762030000d60000482504] 2020/05/06 01:24:50 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 01:25:42 RX: [c133620300ffff0000362404] 2020/05/06 01:25:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 01:26:20 RX: [c13662170000c800b52d240c] 2020/05/06 01:26:20 dropping wheel position on the ground: 18.1 2020/05/06 01:26:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 01:26:53 RX: [c10f620300010900003b2503] 2020/05/06 01:26:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 01:27:19 RX: [c13e62030000ef00003c240c] 2020/05/06 01:27:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 01:28:10 RX: [c10162170000e800de2d2406] 2020/05/06 01:28:10 dropping wheel position on the ground: 22.2 2020/05/06 01:28:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 01:29:19 RX: [c13c623f00b301b5002d2406a5000000441005a50ca5000000462408] 2020/05/06 01:29:19 (partially decoded) temp 18.1C moisture 43.5% 2020/05/06 01:29:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 01:29:19 Message not handled [c13c623f00b301b5002d2406a5000000441005a50ca5000000462408] 2020/05/06 01:29:29 RX: [c13c624200b395ea102d2406a5000000441005a50ca5000000462409] 2020/05/06 01:29:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 01:29:29 Message not handled [c13c624200b395ea102d2406a5000000441005a50ca5000000462409] 2020/05/06 01:31:42 RX: [c135620400425e666636240d] 2020/05/06 01:31:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.6 2020/05/06 01:32:22 RX: [c13462170000ca000037240e] 2020/05/06 01:32:22 dropping wheel position on the ground: 0.0 2020/05/06 01:32:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 01:33:10 RX: [c10c62030000f600002d2409] 2020/05/06 01:33:10 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 01:35:35 RX: [c11562030000ff0000492508] 2020/05/06 01:35:35 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/06 01:35:44 RX: [c13c624200750fcb10492508a5000000441005a50ca500000047240a] 2020/05/06 01:35:44 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 01:35:44 Message not handled [c13c624200750fcb10492508a5000000441005a50ca500000047240a] 2020/05/06 01:37:40 RX: [c13f62030000e400002e2408] 2020/05/06 01:37:40 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 01:42:00 RX: [c13c624200f281db102e2408a5000000441005a50ca500000046240b] 2020/05/06 01:42:00 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 01:42:00 Message not handled [c13c624200f281db102e2408a5000000441005a50ca500000046240b] 2020/05/06 01:43:40 RX: [c137620400421ccccd2e2403] 2020/05/06 01:43:40 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/06 01:43:41 RX: [c13f62030000e900002e2409] 2020/05/06 01:43:41 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 01:43:59 RX: [c13a62170000c600c13c2402] 2020/05/06 01:43:59 dropping wheel position on the ground: 19.3 2020/05/06 01:43:59 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/06 01:44:20 RX: [c13f62030000e900002d240a] 2020/05/06 01:44:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 01:45:19 RX: [c13b620400422f999a3c2406] 2020/05/06 01:45:19 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.9 2020/05/06 01:49:00 RX: [c10c62030000f900002d240a] 2020/05/06 01:49:00 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 01:50:40 RX: [c109620400421a00002d240e] 2020/05/06 01:50:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.5 2020/05/06 01:54:52 RX: [c11762030000d60000492506] 2020/05/06 01:54:52 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 01:55:42 RX: [c133620300ffff0000352405] 2020/05/06 01:55:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 01:56:20 RX: [c13662170000c700b52d240d] 2020/05/06 01:56:20 dropping wheel position on the ground: 18.1 2020/05/06 01:56:20 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/06 01:56:55 RX: [c10f620300010900003b2505] 2020/05/06 01:56:55 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 01:57:19 RX: [c13e62030000f000003c240d] 2020/05/06 01:57:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/06 01:58:10 RX: [c10162170000e600de2d2407] 2020/05/06 01:58:10 dropping wheel position on the ground: 22.2 2020/05/06 01:58:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/06 01:59:29 RX: [c13c624200123398102d2407a5000000441005a50ca500000046240c] 2020/05/06 01:59:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 01:59:29 Message not handled [c13c624200123398102d2407a5000000441005a50ca500000046240c] 2020/05/06 02:00:00 RX: [c1007339005fcb66004a042019000000441006] 2020/05/06 02:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 02:01:42 RX: [c135620400425e000035240e] 2020/05/06 02:01:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.5 2020/05/06 02:02:22 RX: [c13462170000ca000035240f] 2020/05/06 02:02:22 dropping wheel position on the ground: 0.0 2020/05/06 02:02:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 02:02:59 RX: [c13f62030000e400002d240b] 2020/05/06 02:02:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 02:05:37 RX: [c11562030000ff000049250a] 2020/05/06 02:05:37 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/06 02:05:45 RX: [c13c62420055bd881049250aa5000000441006a50ca500000046240d] 2020/05/06 02:05:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 02:05:45 Message not handled [c13c62420055bd881049250aa5000000441006a50ca500000046240d] 2020/05/06 02:07:59 RX: [c13e62030000ea00003c240e] 2020/05/06 02:07:59 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 02:10:04 RX: [c1007339005fcb66004a04101a000000451007] 2020/05/06 02:10:04 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 02:11:19 RX: [c13e62030000ef00003c240f] 2020/05/06 02:11:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 02:12:01 RX: [c13c6242001227a9103c240fa5000000451007a50ca500000045240e] 2020/05/06 02:12:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:12:01 Message not handled [c13c6242001227a9103c240fa5000000451007a50ca500000045240e] 2020/05/06 02:13:39 RX: [c137620400421d999a2d2404] 2020/05/06 02:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.4 2020/05/06 02:13:59 RX: [c13a62170000c500c13c2403] 2020/05/06 02:13:59 dropping wheel position on the ground: 19.3 2020/05/06 02:13:59 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.7 2020/05/06 02:14:59 RX: [c13f62030000e200002d240c] 2020/05/06 02:14:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.6 2020/05/06 02:15:19 RX: [c13b6204004231999a3c2407] 2020/05/06 02:15:19 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.4 2020/05/06 02:19:00 RX: [c10c62030000f800002e240b] 2020/05/06 02:19:00 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 02:19:21 RX: [c13c623f00ad01b4002e240ba5000000451007a50ca500000045240f] 2020/05/06 02:19:21 (partially decoded) temp 18.0C moisture 42.9% 2020/05/06 02:19:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 02:19:21 Message not handled [c13c623f00ad01b4002e240ba5000000451007a50ca500000045240f] 2020/05/06 02:19:31 RX: [c13c624200ad4b3e102e240ba5000000451007a50ca5000000462400] 2020/05/06 02:19:31 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:19:31 Message not handled [c13c624200ad4b3e102e240ba5000000451007a50ca5000000462400] 2020/05/06 02:20:40 RX: [c1096204004219999a2e240f] 2020/05/06 02:20:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.4 2020/05/06 02:21:59 RX: [c13e62030000ea00003c2400] 2020/05/06 02:21:59 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 02:24:53 RX: [c11762030000d60000482508] 2020/05/06 02:24:53 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 02:25:19 RX: [c13e62030000ef00003c2401] 2020/05/06 02:25:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 02:25:42 RX: [c133620300ffff0000352406] 2020/05/06 02:25:42 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 02:25:46 RX: [c13c62420012c52e10352406a5000000451007a50ca5000000452401] 2020/05/06 02:25:46 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:25:46 Message not handled [c13c62420012c52e10352406a5000000451007a50ca5000000452401] 2020/05/06 02:26:19 RX: [c13662170000c600b52e240e] 2020/05/06 02:26:19 dropping wheel position on the ground: 18.1 2020/05/06 02:26:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/06 02:26:20 RX: [c13f62030000e700002d240d] 2020/05/06 02:26:20 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/06 02:26:57 RX: [c10f620300010900003b2507] 2020/05/06 02:26:57 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 02:28:10 RX: [c10162170000e600de2d2408] 2020/05/06 02:28:10 dropping wheel position on the ground: 22.2 2020/05/06 02:28:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/06 02:29:59 RX: [c13e62030000ee00003c2402] 2020/05/06 02:29:59 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 02:31:42 RX: [c135620400425ccccd36240f] 2020/05/06 02:31:42 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.2 2020/05/06 02:32:01 RX: [c13c624200125f0f1036240fa5000000451007a50ca5000000462402] 2020/05/06 02:32:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:32:01 Message not handled [c13c624200125f0f1036240fa5000000451007a50ca5000000462402] 2020/05/06 02:32:22 RX: [c13462170000ca0000362400] 2020/05/06 02:32:22 dropping wheel position on the ground: 0.0 2020/05/06 02:32:22 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 02:33:19 RX: [c13e62030000e800003c2403] 2020/05/06 02:33:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 02:33:39 RX: [c13f62030000e200002d240e] 2020/05/06 02:33:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.6 2020/05/06 02:35:39 RX: [c11562030000fc000049250c] 2020/05/06 02:35:39 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.2 2020/05/06 02:37:19 RX: [c13e62030000ed00003d2404] 2020/05/06 02:37:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 02:41:22 RX: [c13c623f00ad01b3003d2404a5000000451007a50ca5000000462403] 2020/05/06 02:41:22 (partially decoded) temp 17.9C moisture 42.9% 2020/05/06 02:41:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 02:41:22 Message not handled [c13c623f00ad01b3003d2404a5000000451007a50ca5000000462403] 2020/05/06 02:43:39 RX: [c137620400421d999a2e2405] 2020/05/06 02:43:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.4 2020/05/06 02:43:59 RX: [c13a62170000c400c13c2404] 2020/05/06 02:43:59 dropping wheel position on the ground: 19.3 2020/05/06 02:43:59 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 02:44:02 RX: [c13c623f00ac01b4003c2404a5000000451007a50ca5000000472404] 2020/05/06 02:44:02 (partially decoded) temp 18.0C moisture 42.8% 2020/05/06 02:44:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 02:44:02 Message not handled [c13c623f00ac01b4003c2404a5000000451007a50ca5000000472404] 2020/05/06 02:45:19 RX: [c13b620400423133333c2408] 2020/05/06 02:45:19 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.3 2020/05/06 02:46:19 RX: [c13f62030000e500002d240f] 2020/05/06 02:46:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 02:49:00 RX: [c10c62030000f400002e240c] 2020/05/06 02:49:00 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 02:49:31 RX: [c13c62420012ed4c102e240ca5000000451007a50ca5000000452405] 2020/05/06 02:49:31 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:49:31 Message not handled [c13c62420012ed4c102e240ca5000000451007a50ca5000000452405] 2020/05/06 02:50:40 RX: [c109620400421a00002d2400] 2020/05/06 02:50:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.5 2020/05/06 02:51:39 RX: [c13f62030000de00002d2400] 2020/05/06 02:51:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.2 2020/05/06 02:54:55 RX: [c11762030000d2000049250a] 2020/05/06 02:54:55 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 02:54:59 RX: [c13f62030000e400002d2401] 2020/05/06 02:54:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 02:55:41 RX: [c133620300ffff0000352407] 2020/05/06 02:55:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 02:55:46 RX: [c13c62420012776d10352407a5000000451007a50ca5000000452406] 2020/05/06 02:55:46 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 02:55:46 Message not handled [c13c62420012776d10352407a5000000451007a50ca5000000452406] 2020/05/06 02:56:19 RX: [c13662170000c500b52d240f] 2020/05/06 02:56:19 dropping wheel position on the ground: 18.1 2020/05/06 02:56:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.7 2020/05/06 02:56:59 RX: [c10f620300010900003b2509] 2020/05/06 02:56:59 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 02:58:10 RX: [c10162170000e500de2e2409] 2020/05/06 02:58:10 dropping wheel position on the ground: 22.2 2020/05/06 02:58:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 03:00:00 RX: [c1007339005fcb66004a042019000000441008] 2020/05/06 03:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 03:01:19 RX: [c13e62030000ec00003c2405] 2020/05/06 03:01:19 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/06 03:01:41 RX: [c135620400425ccccd362400] 2020/05/06 03:01:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.2 2020/05/06 03:02:02 RX: [c13c62420012f97d10362400a5000000441008a50ca5000000452407] 2020/05/06 03:02:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:02:02 Message not handled [c13c62420012f97d10362400a5000000441008a50ca5000000452407] 2020/05/06 03:02:21 RX: [c13462170000ca0000362401] 2020/05/06 03:02:21 dropping wheel position on the ground: 0.0 2020/05/06 03:02:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 03:05:40 RX: [c11562030000fc000048250e] 2020/05/06 03:05:40 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.2 2020/05/06 03:08:59 RX: [c13f62030000df00002d2402] 2020/05/06 03:08:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.3 2020/05/06 03:09:23 RX: [c13c623f00ad01b3002d2402a5000000441008a50ca5000000462408] 2020/05/06 03:09:23 (partially decoded) temp 17.9C moisture 42.9% 2020/05/06 03:09:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 03:09:23 Message not handled [c13c623f00ad01b3002d2402a5000000441008a50ca5000000462408] 2020/05/06 03:09:33 RX: [c13c624200ad95ea102d2402a5000000441008a50ca5000000472409] 2020/05/06 03:09:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:09:33 Message not handled [c13c624200ad95ea102d2402a5000000441008a50ca5000000472409] 2020/05/06 03:10:00 RX: [c1007339005fcb66004a04101a000000441009] 2020/05/06 03:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 03:13:39 RX: [c137620400421e66662d2406] 2020/05/06 03:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.6 2020/05/06 03:13:58 RX: [c13a62170000c300c13c2405] 2020/05/06 03:13:58 dropping wheel position on the ground: 19.3 2020/05/06 03:13:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 03:15:00 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 03:15:00 RX: [c1147000010000000037100c] 2020/05/06 03:15:00 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 03:15:02 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 03:15:02 RX: [c11870000100000000431004] 2020/05/06 03:15:02 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 03:15:06 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 03:15:06 RX: [c110700001000000004d100b] 2020/05/06 03:15:06 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal weak, cyclic false) status switched on 2020/05/06 03:15:10 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 03:15:12 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 03:15:18 RX: [c13b620400423200003c2409] 2020/05/06 03:15:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.5 2020/05/06 03:15:48 RX: [c13c624200120fcb103c2409a5004310041009a50ca500000046240a] 2020/05/06 03:15:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:15:48 Message not handled [c13c624200120fcb103c2409a5004310041009a50ca500000046240a] 2020/05/06 03:18:19 RX: [c13f62030000e000002e2403] 2020/05/06 03:18:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.4 2020/05/06 03:18:55 RX: [c10f620300011000003b250b] 2020/05/06 03:18:55 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 03:19:00 RX: [c10c62030000f600002e240d] 2020/05/06 03:19:00 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 03:20:40 RX: [c1096204004219999a2d2401] 2020/05/06 03:20:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.4 2020/05/06 03:22:03 RX: [c13c6242001281db102d2401a5004310041009a50ca500000045240b] 2020/05/06 03:22:03 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:22:03 Message not handled [c13c6242001281db102d2401a5004310041009a50ca500000045240b] 2020/05/06 03:24:50 RX: [c10c62030000fe00002d240e] 2020/05/06 03:24:50 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 03:24:56 RX: [c10f620300011700003b250c] 2020/05/06 03:24:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 03:24:57 RX: [c11762030000d6000048250c] 2020/05/06 03:24:57 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 03:25:41 RX: [c133620300ffff0000362408] 2020/05/06 03:25:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 03:26:19 RX: [c13662170000c400b52d2400] 2020/05/06 03:26:19 dropping wheel position on the ground: 18.1 2020/05/06 03:26:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 03:27:18 RX: [c13e62030000f100003c2406] 2020/05/06 03:27:18 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.1 2020/05/06 03:28:10 RX: [c10162170000e500de2d240a] 2020/05/06 03:28:10 dropping wheel position on the ground: 22.2 2020/05/06 03:28:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 03:28:50 RX: [c10f620300012200003b250d] 2020/05/06 03:28:50 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 03:31:30 RX: [c10c620300010700002e240f] 2020/05/06 03:31:30 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/06 03:31:41 RX: [c135620400425d3333362401] 2020/05/06 03:31:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.3 2020/05/06 03:31:58 RX: [c13e62030000f400003c2407] 2020/05/06 03:31:58 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 03:32:17 MQTT message; topic: 'xcomfort/26/set/switch', message: 'false' 2020/05/06 03:32:19 RX: [c100733900b3f868004d000100001d00000052100b] 2020/05/06 03:32:19 Device 6879411, type CDAU 01/04 sent extended status message: value 0, temp 29C (battery mains-powered, signal weak) 2020/05/06 03:32:21 RX: [c13462170000c90000362402] 2020/05/06 03:32:21 dropping wheel position on the ground: 0.0 2020/05/06 03:32:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 03:32:43 RX: [c13c623f00ac01b300362402a5001d00000052100ba500000046240c] 2020/05/06 03:32:43 (partially decoded) temp 17.9C moisture 42.8% 2020/05/06 03:32:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 03:32:43 Message not handled [c13c623f00ac01b300362402a5001d00000052100ba500000046240c] 2020/05/06 03:35:23 RX: [c13c623f00ab01b300362402a5001d00000052100ba500000046240d] 2020/05/06 03:35:23 (partially decoded) temp 17.9C moisture 42.7% 2020/05/06 03:35:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 03:35:23 Message not handled [c13c623f00ab01b300362402a5001d00000052100ba500000046240d] 2020/05/06 03:35:42 RX: [c11562030000ff0000492500] 2020/05/06 03:35:42 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/06 03:37:20 RX: [c10c620300010e00002d2400] 2020/05/06 03:37:20 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 03:38:38 RX: [c13e62030000f900003c2408] 2020/05/06 03:38:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 03:39:33 RX: [c13c6242001227a9103c2408a5001d00000052100ba500000046240e] 2020/05/06 03:39:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:39:33 Message not handled [c13c6242001227a9103c2408a5001d00000052100ba500000046240e] 2020/05/06 03:42:58 RX: [c10f620300012900003b250f] 2020/05/06 03:42:58 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 03:42:58 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 03:42:59 RX: [c11870000000000000451006] 2020/05/06 03:42:59 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 03:43:10 RX: [c10c620300011500002d2401] 2020/05/06 03:43:10 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/06 03:43:10 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 03:43:10 RX: [c1147000000000000038100e] 2020/05/06 03:43:10 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 03:43:39 RX: [c137620400421f33332d2407] 2020/05/06 03:43:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/06 03:43:58 RX: [c13a62170000c300c13c2406] 2020/05/06 03:43:58 dropping wheel position on the ground: 19.3 2020/05/06 03:43:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 03:45:18 RX: [c13b6204004231999a3c240a] 2020/05/06 03:45:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.4 2020/05/06 03:45:48 RX: [c13c62420012a9b9103c240aa5002d24010052100ba500000045240f] 2020/05/06 03:45:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:45:48 Message not handled [c13c62420012a9b9103c240aa5002d24010052100ba500000045240f] 2020/05/06 03:47:58 RX: [c13e62030000fe00003c2409] 2020/05/06 03:47:58 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 03:47:58 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 03:48:19 RX: [c13f62030000e300002d2404] 2020/05/06 03:48:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.7 2020/05/06 03:48:58 RX: [c10f620300011e00003b2500] 2020/05/06 03:48:58 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 03:48:58 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 03:48:59 RX: [c11870000100000000441008] 2020/05/06 03:48:59 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 03:50:40 RX: [c109620400421933332d2402] 2020/05/06 03:50:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.3 2020/05/06 03:52:04 RX: [c13c624200124b3e102d2402a5003b25000052100ba5000000472400] 2020/05/06 03:52:04 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:52:04 Message not handled [c13c624200124b3e102d2402a5003b25000052100ba5000000472400] 2020/05/06 03:52:20 RX: [c10c620300011600002d2402] 2020/05/06 03:52:20 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.8 2020/05/06 03:54:59 RX: [c11762030000d2000049250e] 2020/05/06 03:54:59 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 03:55:41 RX: [c133620300ffff0000352409] 2020/05/06 03:55:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 03:56:19 RX: [c13662170000c400b52d2401] 2020/05/06 03:56:19 dropping wheel position on the ground: 18.1 2020/05/06 03:56:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 03:58:10 RX: [c10162170000e600de2d240b] 2020/05/06 03:58:10 dropping wheel position on the ground: 22.2 2020/05/06 03:58:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/06 03:59:24 RX: [c13c623f00aa01b4002d240ba5003b25000052100ba5000000452401] 2020/05/06 03:59:24 (partially decoded) temp 18.0C moisture 42.6% 2020/05/06 03:59:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 03:59:24 Message not handled [c13c623f00aa01b4002d240ba5003b25000052100ba5000000452401] 2020/05/06 03:59:34 RX: [c13c624200aa5f0f102d240ba5003b25000052100ba5000000462402] 2020/05/06 03:59:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 03:59:34 Message not handled [c13c624200aa5f0f102d240ba5003b25000052100ba5000000462402] 2020/05/06 03:59:47 RX: [c10f620300012500003b2501] 2020/05/06 03:59:47 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 03:59:47 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 03:59:47 RX: [c1187000000000000045100a] 2020/05/06 03:59:47 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 04:00:00 RX: [c1007339005fcb66004a04201900000044100a] 2020/05/06 04:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 04:00:40 RX: [c10c620300010e00002d2403] 2020/05/06 04:00:40 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 04:01:41 RX: [c135620400425d3333362402] 2020/05/06 04:01:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 55.3 2020/05/06 04:02:21 RX: [c13462170000c90000352403] 2020/05/06 04:02:21 dropping wheel position on the ground: 0.0 2020/05/06 04:02:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 04:03:18 RX: [c13e62030000fe00003c240a] 2020/05/06 04:03:18 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 04:04:53 RX: [c10f620300011b00003b2502] 2020/05/06 04:04:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 04:04:53 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 04:04:54 RX: [c1187000010000000044100c] 2020/05/06 04:04:54 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 04:05:44 RX: [c115620300010a0000492502] 2020/05/06 04:05:44 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.6 2020/05/06 04:05:50 RX: [c13c624200c6d11f10492502a5003b2502100aa50ba5000000462403] 2020/05/06 04:05:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 04:05:50 Message not handled [c13c624200c6d11f10492502a5003b2502100aa50ba5000000462403] 2020/05/06 04:10:00 RX: [c1007339005fcb66004a04101a00000043100b] 2020/05/06 04:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/06 04:10:55 RX: [c10f620300012200003b2504] 2020/05/06 04:10:55 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 04:12:05 RX: [c13c62420012635c103b2504a500000043100ba50ba5000000462404] 2020/05/06 04:12:05 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 04:12:05 Message not handled [c13c62420012635c103b2504a500000043100ba50ba5000000462404] 2020/05/06 04:13:39 RX: [c1376204004220cccd2d2408] 2020/05/06 04:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.2 2020/05/06 04:13:58 RX: [c13a62170000c400c13c2407] 2020/05/06 04:13:58 dropping wheel position on the ground: 19.3 2020/05/06 04:13:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 04:15:18 RX: [c13b6204004230cccd3c240b] 2020/05/06 04:15:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.2 2020/05/06 04:18:19 RX: [c13f62030000e400002d2405] 2020/05/06 04:18:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 04:20:40 RX: [c109620400421866662d2403] 2020/05/06 04:20:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.1 2020/05/06 04:22:20 RX: [c10c620300010700002d2404] 2020/05/06 04:22:20 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/06 04:22:20 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 04:22:20 RX: [c11470000100000000371000] 2020/05/06 04:22:20 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 04:22:38 RX: [c13e62030000f800003c240b] 2020/05/06 04:22:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 04:24:00 RX: [c10c620300010400002d2405] 2020/05/06 04:24:00 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26 2020/05/06 04:25:01 RX: [c11762030000cf0000482500] 2020/05/06 04:25:01 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 04:25:41 RX: [c133620300ffff000035240a] 2020/05/06 04:25:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 04:26:19 RX: [c13662170000c400b52d2402] 2020/05/06 04:26:19 dropping wheel position on the ground: 18.1 2020/05/06 04:26:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 04:26:38 RX: [c13e62030000fd00003c240c] 2020/05/06 04:26:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 04:28:10 RX: [c10162170000e400de2d240c] 2020/05/06 04:28:10 dropping wheel position on the ground: 22.2 2020/05/06 04:28:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 04:28:37 RX: [c10f620300012900003b2505] 2020/05/06 04:28:37 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 04:28:37 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 04:28:38 RX: [c1187000000000000045100e] 2020/05/06 04:28:38 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 04:29:35 RX: [c13c62420029ed4c1045100ea5003b2505100ba50ba5000000452405] 2020/05/06 04:29:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 04:29:35 Message not handled [c13c62420029ed4c1045100ea5003b2505100ba50ba5000000452405] 2020/05/06 04:29:39 RX: [c13f62030000e900002d2406] 2020/05/06 04:29:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 04:29:50 RX: [c10c620300010b00002d2406] 2020/05/06 04:29:50 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 04:31:41 RX: [c1356204004259999a352403] 2020/05/06 04:31:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54.4 2020/05/06 04:32:21 RX: [c13462170000c90000342404] 2020/05/06 04:32:21 dropping wheel position on the ground: 0.0 2020/05/06 04:32:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 04:34:37 RX: [c10f620300012200003b2506] 2020/05/06 04:34:37 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 04:34:38 RX: [c13e62030000fc00003c240d] 2020/05/06 04:34:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 04:35:40 RX: [c10c620300011200002d2407] 2020/05/06 04:35:40 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 04:35:40 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 04:35:40 RX: [c11470000000000000371002] 2020/05/06 04:35:40 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 04:35:46 RX: [c115620300011100004b2504] 2020/05/06 04:35:46 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 04:35:50 RX: [c13c624200d7776d104b2504a5002d2407100ba50ba5000000452406] 2020/05/06 04:35:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 04:35:50 Message not handled [c13c624200d7776d104b2504a5002d2407100ba50ba5000000452406] 2020/05/06 04:38:32 RX: [c10f620300011700003b2507] 2020/05/06 04:38:32 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 04:38:32 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 04:38:33 RX: [c11870000100000000431000] 2020/05/06 04:38:33 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 04:42:06 RX: [c13c62420032f97d10431000a5003b2507100ba50ba5000000462407] 2020/05/06 04:42:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 04:42:06 Message not handled [c13c62420032f97d10431000a5003b2507100ba50ba5000000462407] 2020/05/06 04:42:20 RX: [c10c620300011900002d2408] 2020/05/06 04:42:20 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28.1 2020/05/06 04:43:39 RX: [c1376204004220cccd2d2409] 2020/05/06 04:43:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.2 2020/05/06 04:43:58 RX: [c13a62170000c300c13d2408] 2020/05/06 04:43:58 dropping wheel position on the ground: 19.3 2020/05/06 04:43:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 04:44:34 RX: [c10f620300011e00003b2509] 2020/05/06 04:44:34 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 04:45:18 RX: [c13b6204004230cccd3c240c] 2020/05/06 04:45:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.2 2020/05/06 04:48:59 RX: [c13f62030000ea00002d2407] 2020/05/06 04:48:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 04:49:26 RX: [c13c623f00ac01b3002d2407a5003b2507100ba50ba5000000462408] 2020/05/06 04:49:26 (partially decoded) temp 17.9C moisture 42.8% 2020/05/06 04:49:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 04:49:26 Message not handled [c13c623f00ac01b3002d2407a5003b2507100ba50ba5000000462408] 2020/05/06 04:49:36 RX: [c13c624200ac95ea102d2407a5003b2507100ba50ba5000000452409] 2020/05/06 04:49:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 04:49:36 Message not handled [c13c624200ac95ea102d2407a5003b2507100ba50ba5000000452409] 2020/05/06 04:50:40 RX: [c109620400421acccd2d2404] 2020/05/06 04:50:40 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.7 2020/05/06 04:50:48 RX: [c115620300011c00004b2506] 2020/05/06 04:50:48 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.4 2020/05/06 04:50:48 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 04:50:49 RX: [c1107000000000000049100d] 2020/05/06 04:50:49 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 04:51:58 RX: [c13e62030000f500003c240e] 2020/05/06 04:51:58 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 04:51:58 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 04:52:40 RX: [c10f620300012500003b250a] 2020/05/06 04:52:40 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 04:52:40 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 04:52:41 RX: [c11870000000000000451002] 2020/05/06 04:52:41 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 04:55:03 RX: [c11762030000cf0000472502] 2020/05/06 04:55:03 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 04:55:40 RX: [c10c620300011200002d2409] 2020/05/06 04:55:40 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 04:55:41 RX: [c133620300ffff000036240b] 2020/05/06 04:55:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 04:55:51 RX: [c13c624200120fcb1036240ba5003b250a100ba50ba500000045240a] 2020/05/06 04:55:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 04:55:51 Message not handled [c13c624200120fcb1036240ba5003b250a100ba50ba500000045240a] 2020/05/06 04:56:19 RX: [c13662170000c500b52d2403] 2020/05/06 04:56:19 dropping wheel position on the ground: 18.1 2020/05/06 04:56:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.7 2020/05/06 04:57:19 RX: [c10c620300011100002d240a] 2020/05/06 04:57:19 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/06 04:58:10 RX: [c10162170000e500de2d240d] 2020/05/06 04:58:10 dropping wheel position on the ground: 22.2 2020/05/06 04:58:10 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 04:58:40 RX: [c10f620300011b00003b250b] 2020/05/06 04:58:40 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 04:58:40 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 04:58:41 RX: [c11870000100000000441004] 2020/05/06 04:58:41 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 04:59:58 RX: [c13e62030000fa00003c240f] 2020/05/06 04:59:58 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 05:00:00 RX: [c1007339005fcb66004a04201900000045100c] 2020/05/06 05:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 05:00:59 RX: [c13f62030000ef00002d2408] 2020/05/06 05:00:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 05:01:41 RX: [c13562040042580000352404] 2020/05/06 05:01:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 05:02:07 RX: [c13c6242001281db10352404a500000045100ca50ba500000046240b] 2020/05/06 05:02:07 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 05:02:07 Message not handled [c13c6242001281db10352404a500000045100ca50ba500000046240b] 2020/05/06 05:02:21 RX: [c13462170000c90000342405] 2020/05/06 05:02:21 dropping wheel position on the ground: 0.0 2020/05/06 05:02:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 05:04:41 RX: [c10f620300012200003b250c] 2020/05/06 05:04:41 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 05:05:39 RX: [c13f62030000ea00002d2409] 2020/05/06 05:05:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 05:05:58 RX: [c13e62030000fc00003c2400] 2020/05/06 05:05:58 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 05:09:18 RX: [c13e620300010100003c2401] 2020/05/06 05:09:18 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 05:09:18 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 05:09:39 RX: [c13f62030000ef00002d240a] 2020/05/06 05:09:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 05:10:00 RX: [c1007339005fcb66004a04101a00000045100d] 2020/05/06 05:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 05:13:39 RX: [c137620400422000002d240a] 2020/05/06 05:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40 2020/05/06 05:13:58 RX: [c13a62170000c300c13d2409] 2020/05/06 05:13:58 dropping wheel position on the ground: 19.3 2020/05/06 05:13:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 05:15:18 RX: [c13b6204004230cccd3c240d] 2020/05/06 05:15:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.2 2020/05/06 05:17:00 RX: [c10f620300012900003b250e] 2020/05/06 05:17:00 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 05:17:01 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 05:17:01 RX: [c118700000000000004a1006] 2020/05/06 05:17:01 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 05:17:20 RX: [c11970006200000000391003] 2020/05/06 05:17:20 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 05:18:29 RX: [c108700062000000003a1009] 2020/05/06 05:18:29 Device 5734000 (channel 0-'1.etg stor gang') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 05:19:37 RX: [c13c6242002b3398103a1009a500391003100da50ba500000045240c] 2020/05/06 05:19:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 05:19:37 Message not handled [c13c6242002b3398103a1009a500391003100da50ba500000045240c] 2020/05/06 05:20:39 RX: [c109620400421a00002c2405] 2020/05/06 05:20:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.5 2020/05/06 05:20:51 RX: [c11562030001190000482508] 2020/05/06 05:20:51 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 05:20:59 RX: [c13f62030000f200002d240b] 2020/05/06 05:20:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/06 05:21:52 RX: [c102700062000000004a1004] 2020/05/06 05:21:52 Device 5740117 (channel 0-'1.etg sov 4') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/06 05:23:01 RX: [c10f620300012200003a250f] 2020/05/06 05:23:01 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 05:25:05 RX: [c11762030000cf0000482504] 2020/05/06 05:25:05 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 05:25:41 RX: [c133620300ffff000035240c] 2020/05/06 05:25:41 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 05:25:52 RX: [c13c62420012bd881035240ca5002d240b100da50ba500000046240d] 2020/05/06 05:25:52 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 05:25:52 Message not handled [c13c62420012bd881035240ca5002d240b100da50ba500000046240d] 2020/05/06 05:25:55 RX: [c103700062000000004a100f] 2020/05/06 05:25:55 Device 5734031 (channel 0-'1.etg sov 3') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/06 05:26:19 RX: [c13662170000c600b52c2404] 2020/05/06 05:26:19 dropping wheel position on the ground: 18.1 2020/05/06 05:26:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/06 05:26:55 RX: [c10f620300011700003a2500] 2020/05/06 05:26:55 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 05:26:55 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 05:26:56 RX: [c11870000100000000461008] 2020/05/06 05:26:56 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 05:27:18 RX: [c113700062000000002d1005] 2020/05/06 05:27:18 Device 5734274 (channel 0-'1.etg kj�kken spotter') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 05:27:19 RX: [c10c620300010b00002c240b] 2020/05/06 05:27:19 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 05:27:20 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 05:27:20 RX: [c11470000100000000361004] 2020/05/06 05:27:20 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 05:28:09 RX: [c10162170000e400de2d240e] 2020/05/06 05:28:09 dropping wheel position on the ground: 22.2 2020/05/06 05:28:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 05:31:41 RX: [c13562040042580000372405] 2020/05/06 05:31:41 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 05:32:08 RX: [c13c6242001227a910372405a5002c240b100da50ba500000045240e] 2020/05/06 05:32:08 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 05:32:08 Message not handled [c13c6242001227a910372405a5002c240b100da50ba500000045240e] 2020/05/06 05:32:21 RX: [c13462170000c90000352406] 2020/05/06 05:32:21 dropping wheel position on the ground: 0.0 2020/05/06 05:32:21 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 05:32:55 RX: [c10f620300011e00003a2501] 2020/05/06 05:32:55 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 05:35:39 RX: [c13f62030000ed00002c240c] 2020/05/06 05:35:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 05:35:39 RX: [c10c620300011200002c240c] 2020/05/06 05:35:39 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 05:35:39 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 05:35:40 RX: [c11470000000000000371006] 2020/05/06 05:35:40 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 05:36:38 RX: [c13e62030000ff00003e2402] 2020/05/06 05:36:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 05:39:28 RX: [c13c623f00ac01b3003e2402a5002c240c100da50ba500000045240f] 2020/05/06 05:39:28 (partially decoded) temp 17.9C moisture 42.8% 2020/05/06 05:39:28 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 05:39:28 Message not handled [c13c623f00ac01b3003e2402a5002c240c100da50ba500000045240f] 2020/05/06 05:39:38 RX: [c13c624200ac4b3e103e2402a5002c240c100da50ba5000000452400] 2020/05/06 05:39:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 05:39:38 Message not handled [c13c624200ac4b3e103e2402a5002c240c100da50ba5000000452400] 2020/05/06 05:40:27 RX: [c10f620300012500003c2503] 2020/05/06 05:40:27 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 05:40:27 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 05:40:28 RX: [c1187000000000000044100a] 2020/05/06 05:40:28 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 05:43:39 RX: [c137620400421f33332d240b] 2020/05/06 05:43:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/06 05:43:58 RX: [c13a62170000c300c13e240a] 2020/05/06 05:43:58 dropping wheel position on the ground: 19.3 2020/05/06 05:43:58 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 05:44:19 RX: [c13f62030000f200002d240d] 2020/05/06 05:44:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/06 05:45:18 RX: [c13b620400423000003f240e] 2020/05/06 05:45:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44 2020/05/06 05:45:53 RX: [c13c62420012c52e103f240ea5003c2503100da50ba5000000462401] 2020/05/06 05:45:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 05:45:53 Message not handled [c13c62420012c52e103f240ea5003c2503100da50ba5000000462401] 2020/05/06 05:46:28 RX: [c10f620300011b0000382504] 2020/05/06 05:46:28 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 05:46:28 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 05:46:28 RX: [c1187000010000000041100c] 2020/05/06 05:46:28 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 05:49:18 RX: [c13e62030000fa00003f2403] 2020/05/06 05:49:18 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 05:50:39 RX: [c109620400421ccccd2d2406] 2020/05/06 05:50:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/06 05:50:52 RX: [c1156203000111000049250a] 2020/05/06 05:50:52 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 05:52:09 RX: [c13c624200375f0f1049250aa500382504100da50ba5000000452402] 2020/05/06 05:52:09 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 05:52:09 Message not handled [c13c624200375f0f1049250aa500382504100da50ba5000000452402] 2020/05/06 05:52:19 RX: [c13f62030000f500002d240e] 2020/05/06 05:52:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 05:52:28 RX: [c10f62030001220000372505] 2020/05/06 05:52:28 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 05:52:38 RX: [c13e62030000ff00003d2404] 2020/05/06 05:52:38 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 05:54:06 RX: [c1007339006c0469004d0002ff001e0000003d1003] 2020/05/06 05:54:06 Device 6882412, type CDAU 01/04 sent extended status message: value 255, temp 30C (battery mains-powered, signal good) 2020/05/06 05:54:07 RX: [c1007339008e0269004d0002ff001d0000002d1001] 2020/05/06 05:54:07 Device 6881934, type CDAU 01/04 sent extended status message: value 255, temp 29C (battery mains-powered, signal good) 2020/05/06 05:55:07 RX: [c11762030000cf0000482506] 2020/05/06 05:55:07 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 05:55:40 RX: [c133620300ffff000035240d] 2020/05/06 05:55:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 05:56:19 RX: [c13662170000c700b52d2405] 2020/05/06 05:56:19 dropping wheel position on the ground: 18.1 2020/05/06 05:56:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/06 05:57:57 RX: [c13e62030000fa00003e2405] 2020/05/06 05:57:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 05:58:09 RX: [c10162170000e300de2d240f] 2020/05/06 05:58:09 dropping wheel position on the ground: 22.2 2020/05/06 05:58:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.7 2020/05/06 05:58:10 RX: [c10c620300011000002d240d] 2020/05/06 05:58:10 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 06:00:00 RX: [c1007339005fcb66004a04201900000044100e] 2020/05/06 06:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 06:01:40 RX: [c13562040042580000342406] 2020/05/06 06:01:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 06:01:46 RX: [c10f62030001290000382506] 2020/05/06 06:01:46 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 06:01:46 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 06:01:47 RX: [c1187000000000000045100e] 2020/05/06 06:01:47 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 06:01:52 RX: [c100733900520369004d0002ff001d00000047100d] 2020/05/06 06:01:52 Device 6882130, type CDAU 01/04 sent extended status message: value 255, temp 29C (battery mains-powered, signal normal) 2020/05/06 06:02:03 RX: [c100733900520369004d0002d3001d00000048100e] 2020/05/06 06:02:03 Device 6882130, type CDAU 01/04 sent extended status message: value 211, temp 29C (battery mains-powered, signal normal) 2020/05/06 06:02:20 RX: [c13462170000c90000362407] 2020/05/06 06:02:20 dropping wheel position on the ground: 0.0 2020/05/06 06:02:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 06:07:47 RX: [c10f62030001220000382507] 2020/05/06 06:07:47 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 06:08:37 RX: [c13e62030000fb00003e2406] 2020/05/06 06:08:37 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 06:09:38 RX: [c13c62420012d11f103e2406a5001d00000048100ea5000000462403] 2020/05/06 06:09:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 06:09:38 Message not handled [c13c62420012d11f103e2406a5001d00000048100ea5000000462403] 2020/05/06 06:10:01 RX: [c1007339005fcb66004a04101a00000046100f] 2020/05/06 06:10:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 06:11:42 RX: [c10f62030001170000382509] 2020/05/06 06:11:42 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 06:11:42 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 06:11:43 RX: [c11870000100000000421000] 2020/05/06 06:11:43 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 06:13:39 RX: [c137620400421866662d240c] 2020/05/06 06:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.1 2020/05/06 06:13:57 RX: [c13a62170000c300c13c240b] 2020/05/06 06:13:57 dropping wheel position on the ground: 19.3 2020/05/06 06:13:57 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 06:15:17 RX: [c13b620400422f999a3d240f] 2020/05/06 06:15:17 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.9 2020/05/06 06:15:54 RX: [c13c62420012635c103d240fa500382509100fa50ea5000000452404] 2020/05/06 06:15:54 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 06:15:54 Message not handled [c13c62420012635c103d240fa500382509100fa50ea5000000452404] 2020/05/06 06:17:25 RX: [c10f6203000122000038250a] 2020/05/06 06:17:25 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 06:20:39 RX: [c109620400421ccccd2d2407] 2020/05/06 06:20:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/06 06:20:54 RX: [c115620300010e00004b250c] 2020/05/06 06:20:54 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 06:20:55 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 06:20:55 RX: [c1107000010000000045100f] 2020/05/06 06:20:55 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 06:22:10 RX: [c13c62420022ed4c1045100fa5004b250c100fa50ea5000000442405] 2020/05/06 06:22:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 06:22:10 Message not handled [c13c62420022ed4c1045100fa5004b250c100fa50ea5000000442405] 2020/05/06 06:22:19 RX: [c13f62030000f700002d240f] 2020/05/06 06:22:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 06:24:49 RX: [c10c620300010900002d240e] 2020/05/06 06:24:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.5 2020/05/06 06:24:49 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 06:24:50 RX: [c11470000100000000361008] 2020/05/06 06:24:50 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 06:25:09 RX: [c11762030000cf0000452508] 2020/05/06 06:25:09 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 06:25:40 RX: [c133620300ffff000036240e] 2020/05/06 06:25:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 06:26:19 RX: [c13662170000c800b52d2406] 2020/05/06 06:26:19 dropping wheel position on the ground: 18.1 2020/05/06 06:26:19 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 06:27:37 RX: [c10f6203000129000038250b] 2020/05/06 06:27:37 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 06:27:37 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 06:27:38 RX: [c11870000000000000431002] 2020/05/06 06:27:38 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 06:28:09 RX: [c10162170000e400de2d2400] 2020/05/06 06:28:09 dropping wheel position on the ground: 22.2 2020/05/06 06:28:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 06:28:59 RX: [c10c620300010b00002d240f] 2020/05/06 06:28:59 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 06:29:30 RX: [c13c623f00ae01b3002d240fa50038250b100fa50ea5000000442406] 2020/05/06 06:29:30 (partially decoded) temp 17.9C moisture 43.0% 2020/05/06 06:29:30 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 06:29:30 Message not handled [c13c623f00ae01b3002d240fa50038250b100fa50ea5000000442406] 2020/05/06 06:29:40 RX: [c13c624200aef97d102d240fa50038250b100fa50ea5000000442407] 2020/05/06 06:29:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 06:29:40 Message not handled [c13c624200aef97d102d240fa50038250b100fa50ea5000000442407] 2020/05/06 06:31:40 RX: [c1356204004257999a352407] 2020/05/06 06:31:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 53.9 2020/05/06 06:32:20 RX: [c13462170000c80000362408] 2020/05/06 06:32:20 dropping wheel position on the ground: 0.0 2020/05/06 06:32:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 06:33:09 RX: [c10c620300011200002d2400] 2020/05/06 06:33:09 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 06:33:09 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 06:33:10 RX: [c1147000000000000037100a] 2020/05/06 06:33:10 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 06:33:37 RX: [c10f6203000122000038250c] 2020/05/06 06:33:37 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 06:35:55 RX: [c13c624200121bfa1038250ca5002d2400100fa50ea5000000462408] 2020/05/06 06:35:55 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 06:35:55 Message not handled [c13c624200121bfa1038250ca5002d2400100fa50ea5000000462408] 2020/05/06 06:36:37 RX: [c13e62030000f500003e2407] 2020/05/06 06:36:37 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 06:36:37 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 06:37:32 RX: [c10f6203000117000038250d] 2020/05/06 06:37:32 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 06:37:32 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 06:37:32 RX: [c11870000100000000411004] 2020/05/06 06:37:32 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 06:39:17 RX: [c13e62030000f800003d2408] 2020/05/06 06:39:17 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 06:42:11 RX: [c13c6242005295ea103d2408a50038250d100fa50ea5000000452409] 2020/05/06 06:42:11 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 06:42:11 Message not handled [c13c6242005295ea103d2408a50038250d100fa50ea5000000452409] 2020/05/06 06:43:15 RX: [c10f6203000122000038250f] 2020/05/06 06:43:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 06:43:39 RX: [c137620400421ccccd2c240d] 2020/05/06 06:43:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/06 06:43:57 RX: [c13a62170000c300c13d240c] 2020/05/06 06:43:57 dropping wheel position on the ground: 19.3 2020/05/06 06:43:57 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 06:45:18 RX: [c13b620400422f999a3d2400] 2020/05/06 06:45:18 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.9 2020/05/06 06:46:20 RX: [c115620300011900004a250d] 2020/05/06 06:46:20 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 06:46:20 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 06:46:20 RX: [c11070000000000000441001] 2020/05/06 06:46:20 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 06:46:59 RX: [c13f62030000fc00002d2400] 2020/05/06 06:46:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 06:47:57 RX: [c13e62030000fd00003d2409] 2020/05/06 06:47:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 06:47:57 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 06:50:39 RX: [c1096204004225999a2d2408] 2020/05/06 06:50:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.4 2020/05/06 06:52:59 RX: [c13f62030000f800002d2401] 2020/05/06 06:52:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 06:53:46 RX: [c10f62030001290000372500] 2020/05/06 06:53:46 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 06:53:46 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 06:53:47 RX: [c11870000000000000441006] 2020/05/06 06:53:47 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 06:55:11 RX: [c11762030000cf000046250a] 2020/05/06 06:55:11 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 06:55:39 RX: [c13662170000cd00b52d2407] 2020/05/06 06:55:39 dropping wheel position on the ground: 18.1 2020/05/06 06:55:39 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 06:55:40 RX: [c133620300ffff000035240f] 2020/05/06 06:55:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 06:56:59 RX: [c13662170000cd00b52d2408] 2020/05/06 06:56:59 dropping wheel position on the ground: 18.1 2020/05/06 06:56:59 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 06:58:09 RX: [c10162170000e500de2d2401] 2020/05/06 06:58:09 dropping wheel position on the ground: 22.2 2020/05/06 06:58:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 06:59:40 RX: [c13c624200120fcb102d2401a500372500100fa50ea500000046240a] 2020/05/06 06:59:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 06:59:40 Message not handled [c13c624200120fcb102d2401a500372500100fa50ea500000046240a] 2020/05/06 06:59:46 RX: [c10f62030001220000382501] 2020/05/06 06:59:46 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 06:59:49 RX: [c10c620300011100002d2401] 2020/05/06 06:59:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/06 07:00:00 RX: [c1007339005fcb66004a042019000000461000] 2020/05/06 07:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 07:01:40 RX: [c13562040042580000352408] 2020/05/06 07:01:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 07:02:20 RX: [c13462170000c90000362409] 2020/05/06 07:02:20 dropping wheel position on the ground: 0.0 2020/05/06 07:02:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 07:04:17 RX: [c10f62030001170000382502] 2020/05/06 07:04:17 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 07:04:17 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 07:04:17 RX: [c11870000100000000421008] 2020/05/06 07:04:17 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 07:05:56 RX: [c13c6242002581db10421008a5003825021000a50ea500000046240b] 2020/05/06 07:05:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 07:05:56 Message not handled [c13c6242002581db10421008a5003825021000a50ea500000046240b] 2020/05/06 07:07:39 RX: [c13f62030000fe00002e2402] 2020/05/06 07:07:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 07:07:39 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 07:08:11 RX: [c10f62030001220000382503] 2020/05/06 07:08:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 07:09:57 RX: [c13e62030000fc00003f240a] 2020/05/06 07:09:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 07:10:01 RX: [c1007339005fcb66004a04101a000000461001] 2020/05/06 07:10:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 07:10:59 RX: [c13f62030000f900002e2403] 2020/05/06 07:10:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 07:12:12 RX: [c13c624200123398102e2403a5000000461001a50ea500000046240c] 2020/05/06 07:12:12 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 07:12:12 Message not handled [c13c624200123398102e2403a5000000461001a50ea500000046240c] 2020/05/06 07:13:39 RX: [c137620400421c00002d240e] 2020/05/06 07:13:39 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39 2020/05/06 07:13:57 RX: [c13a62170000c300c13d240d] 2020/05/06 07:13:57 dropping wheel position on the ground: 19.3 2020/05/06 07:13:57 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/06 07:14:19 RX: [c13f62030000fe00002d2404] 2020/05/06 07:14:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 07:15:17 RX: [c13b6204004230cccd3d2401] 2020/05/06 07:15:17 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.2 2020/05/06 07:16:01 RX: [c10f62030001290000382505] 2020/05/06 07:16:01 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 07:16:01 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 07:16:01 RX: [c1187000000000000045100a] 2020/05/06 07:16:01 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 07:16:22 RX: [c115620300011500004a250f] 2020/05/06 07:16:22 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.7 2020/05/06 07:19:32 RX: [c13c623f00b201b4004a250fa5003825051001a50ea500000045240d] 2020/05/06 07:19:32 (partially decoded) temp 18.0C moisture 43.4% 2020/05/06 07:19:32 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT OUT 2020/05/06 07:19:32 Message not handled [c13c623f00b201b4004a250fa5003825051001a50ea500000045240d] 2020/05/06 07:19:42 RX: [c13c624200b227a9104a250fa5003825051001a50ea500000047240e] 2020/05/06 07:19:42 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 07:19:42 Message not handled [c13c624200b227a9104a250fa5003825051001a50ea500000047240e] 2020/05/06 07:20:39 RX: [c1096204004223999a2d2409] 2020/05/06 07:20:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.9 2020/05/06 07:21:39 RX: [c13f62030000f900002e2405] 2020/05/06 07:21:39 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 07:22:19 RX: [c10f62030001220000392506] 2020/05/06 07:22:19 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 07:24:58 RX: [c13f62030000ff00002e2406] 2020/05/06 07:24:58 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 07:25:12 RX: [c11762030000cf000046250c] 2020/05/06 07:25:12 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 07:25:40 RX: [c133620300ffff0000352400] 2020/05/06 07:25:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 07:25:57 RX: [c13c62420012a9b910352400a5003825051001a50ea500000046240f] 2020/05/06 07:25:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 07:25:57 Message not handled [c13c62420012a9b910352400a5003825051001a50ea500000046240f] 2020/05/06 07:26:19 RX: [c13f62030000ff00002e2407] 2020/05/06 07:26:19 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 07:26:59 RX: [c13662170000ce00b52d2409] 2020/05/06 07:26:59 dropping wheel position on the ground: 18.1 2020/05/06 07:26:59 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/06 07:27:25 RX: [c10f62030001170000382507] 2020/05/06 07:27:25 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 07:27:26 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 07:27:26 RX: [c1187000010000000043100c] 2020/05/06 07:27:26 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 07:28:09 RX: [c10162170000e600de2e2402] 2020/05/06 07:28:09 dropping wheel position on the ground: 22.2 2020/05/06 07:28:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/06 07:29:49 RX: [c10c620300010b00002e2402] 2020/05/06 07:29:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 07:29:49 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 07:29:49 RX: [c1147000010000000036100c] 2020/05/06 07:29:49 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 07:31:38 RX: [c10f62030001220000382508] 2020/05/06 07:31:38 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 07:31:40 RX: [c13562040042580000362409] 2020/05/06 07:31:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 07:32:12 RX: [c13c624200124b3e10362409a5002e24021001a50ea5000000452400] 2020/05/06 07:32:12 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 07:32:12 Message not handled [c13c624200124b3e10362409a5002e24021001a50ea5000000452400] 2020/05/06 07:32:20 RX: [c13462170000c9000035240a] 2020/05/06 07:32:20 dropping wheel position on the ground: 0.0 2020/05/06 07:32:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 07:37:04 RX: [c1067000000000000051100d] 2020/05/06 07:37:04 Device 5736891 (channel 0-'1.etg bad speil') sent message (battery mains-powered, signal weak, cyclic false) value 0 2020/05/06 07:37:05 RX: [c113700000000000002d1006] 2020/05/06 07:37:05 Device 5734274 (channel 0-'1.etg kj�kken spotter') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 07:37:05 RX: [c108700000000000003c1005] 2020/05/06 07:37:05 Device 5734000 (channel 0-'1.etg stor gang') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 07:37:05 RX: [c11970000000000000391004] 2020/05/06 07:37:05 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 07:37:06 RX: [c111700001000000003a1007] 2020/05/06 07:37:06 Device 5727252 (channel 0-'utelys hovedd�r') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 07:37:08 RX: [c10a700062000000003b100e] 2020/05/06 07:37:08 Device 5733992 (channel 0-'1.etg tv stue') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 07:37:08 RX: [c10b7000620000000046100d] 2020/05/06 07:37:08 Device 5734068 (channel 0-'1.etg liten gang') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/06 07:37:08 RX: [c1067000620000000052100e] 2020/05/06 07:37:08 Device 5736891 (channel 0-'1.etg bad speil') sent message (battery mains-powered, signal weak, cyclic false) value 98 2020/05/06 07:37:09 RX: [c10770006200000000431001] 2020/05/06 07:37:09 Device 5736925 (channel 0-'1.etg bad tak') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 07:37:09 RX: [c113700062000000002d1008] 2020/05/06 07:37:09 Device 5734274 (channel 0-'1.etg kj�kken spotter') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 07:37:10 RX: [c108700062000000003d1007] 2020/05/06 07:37:10 Device 5734000 (channel 0-'1.etg stor gang') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 07:37:10 RX: [c11970006200000000391006] 2020/05/06 07:37:10 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 07:37:12 RX: [c10d70006200000000441001] 2020/05/06 07:37:12 Device 5741956 (channel 0-'1.etg stue lampe spi') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/06 07:37:17 RX: [c1007339006c0469004d0002ff00260000003d1004] 2020/05/06 07:37:17 Device 6882412, type CDAU 01/04 sent extended status message: value 255, temp 38C (battery mains-powered, signal good) 2020/05/06 07:37:19 RX: [c100733900d80269004d0002ff0023000000371003] 2020/05/06 07:37:19 Device 6882008, type CDAU 01/04 sent extended status message: value 255, temp 35C (battery mains-powered, signal good) 2020/05/06 07:37:20 RX: [c100733900b4fa68004d0002ff001b000000441004] 2020/05/06 07:37:20 Device 6879924, type CDAU 01/04 sent extended status message: value 255, temp 27C (battery mains-powered, signal normal) 2020/05/06 07:37:21 RX: [c100733900520369004d0002d3002600000011100f] 2020/05/06 07:37:21 Device 6882130, type CDAU 01/04 sent extended status message: value 211, temp 38C (battery mains-powered, signal good) 2020/05/06 07:37:21 RX: [c100733900070569004d0002ff0020000000111000] 2020/05/06 07:37:21 Device 6882567, type CDAU 01/04 sent extended status message: value 255, temp 32C (battery mains-powered, signal good) 2020/05/06 07:37:22 RX: [c1007339008e0269004d0002ff00240000002e1002] 2020/05/06 07:37:22 Device 6881934, type CDAU 01/04 sent extended status message: value 255, temp 36C (battery mains-powered, signal good) 2020/05/06 07:37:23 RX: [c1007339004b0369004d0002ff001f0000003a100a] 2020/05/06 07:37:23 Device 6882123, type CDAU 01/04 sent extended status message: value 255, temp 31C (battery mains-powered, signal good) 2020/05/06 07:37:24 RX: [c100733900ec0469004d0002ff001e0000003e100c] 2020/05/06 07:37:24 Device 6882540, type CDAU 01/04 sent extended status message: value 255, temp 30C (battery mains-powered, signal good) 2020/05/06 07:38:09 RX: [c10c620300011200002f2403] 2020/05/06 07:38:09 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 07:38:09 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 07:38:09 RX: [c1147000000000000036100e] 2020/05/06 07:38:09 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 07:38:50 RX: [c10f620300012900003c2509] 2020/05/06 07:38:50 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 07:38:50 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 07:38:51 RX: [c1187000000000000046100e] 2020/05/06 07:38:51 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 07:39:57 RX: [c13e62030000fa00003d240b] 2020/05/06 07:39:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 07:42:53 RX: [c13c623f00bc01b4003d240ba5003c2509003e100ca5000000462401] 2020/05/06 07:42:53 (partially decoded) temp 18.0C moisture 44.4% 2020/05/06 07:42:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 07:42:53 Message not handled [c13c623f00bc01b4003d240ba5003c2509003e100ca5000000462401] 2020/05/06 07:43:38 RX: [c137620400421ccccd2e240f] 2020/05/06 07:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/06 07:43:57 RX: [c13a62170000c400c13d240e] 2020/05/06 07:43:57 dropping wheel position on the ground: 19.3 2020/05/06 07:43:57 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 07:44:52 RX: [c10f620300012200003c250b] 2020/05/06 07:44:52 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 07:44:58 RX: [c13f62030000f800002e2408] 2020/05/06 07:44:58 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 07:45:17 RX: [c13b620400423000003d2402] 2020/05/06 07:45:17 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44 2020/05/06 07:45:33 RX: [c13c623f00bb01b4003d2402a5003c2509003e100ca5000000462402] 2020/05/06 07:45:33 (partially decoded) temp 18.0C moisture 44.3% 2020/05/06 07:45:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 07:45:33 Message not handled [c13c623f00bb01b4003d2402a5003c2509003e100ca5000000462402] 2020/05/06 07:46:24 RX: [c11562030001110000482501] 2020/05/06 07:46:24 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 07:49:34 RX: [c10a700000000000003b1001] 2020/05/06 07:49:34 Device 5733992 (channel 0-'1.etg tv stue') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 07:49:41 RX: [c10f620300011700003b250c] 2020/05/06 07:49:41 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 07:49:41 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 07:49:41 RX: [c11870000100000000431000] 2020/05/06 07:49:41 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 07:50:22 RX: [c13c62420026d11f10431000a5003b250c003e100ca5000000452403] 2020/05/06 07:50:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 07:50:22 Message not handled [c13c62420026d11f10431000a5003b250c003e100ca5000000452403] 2020/05/06 07:50:39 RX: [c109620400422133332e240a] 2020/05/06 07:50:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.3 2020/05/06 07:53:53 RX: [c10f620300012200003c250d] 2020/05/06 07:53:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 07:55:14 RX: [c11762030000cf00004b250e] 2020/05/06 07:55:14 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 07:55:40 RX: [c133620300ffff0000372401] 2020/05/06 07:55:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 07:56:37 RX: [c13c62420012635c10372401a5003b250c003e100ca5000000472404] 2020/05/06 07:56:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 07:56:37 Message not handled [c13c62420012635c10372401a5003b250c003e100ca5000000472404] 2020/05/06 07:56:58 RX: [c13662170000cf00b52e240a] 2020/05/06 07:56:58 dropping wheel position on the ground: 18.1 2020/05/06 07:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 07:56:59 RX: [c13f62030000fd00002e2409] 2020/05/06 07:56:59 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 07:57:38 RX: [c13f62030000fa00002e240a] 2020/05/06 07:57:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 07:58:09 RX: [c10162170000e700de2e2403] 2020/05/06 07:58:09 dropping wheel position on the ground: 22.2 2020/05/06 07:58:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/06 08:00:00 RX: [c1007339005fcb66004a042019000000451002] 2020/05/06 08:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 08:00:39 RX: [c10c620300011200002e2404] 2020/05/06 08:00:39 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 08:01:40 RX: [c1356204004258000035240a] 2020/05/06 08:01:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 54 2020/05/06 08:01:41 RX: [c10f620300012900003c250e] 2020/05/06 08:01:41 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 08:01:41 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 08:01:42 RX: [c11870000000000000461002] 2020/05/06 08:01:42 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 08:02:20 RX: [c13462170000c9000037240b] 2020/05/06 08:02:20 dropping wheel position on the ground: 0.0 2020/05/06 08:02:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 08:02:52 RX: [c13c62420012ed4c1037240ba5003c250e1002a50ca5000000462405] 2020/05/06 08:02:52 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:02:52 Message not handled [c13c62420012ed4c1037240ba5003c250e1002a50ca5000000462405] 2020/05/06 08:07:42 RX: [c10f620300012200003c250f] 2020/05/06 08:07:42 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 08:09:34 RX: [c13c623f00cf01b4003c250fa5003c250e1002a50ca5000000452406] 2020/05/06 08:09:34 (partially decoded) temp 18.0C moisture 46.3% 2020/05/06 08:09:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT OUT 2020/05/06 08:09:34 Message not handled [c13c623f00cf01b4003c250fa5003c250e1002a50ca5000000452406] 2020/05/06 08:09:44 RX: [c13c624200cff97d103c250fa5003c250e1002a50ca5000000452407] 2020/05/06 08:09:44 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 08:09:44 Message not handled [c13c624200cff97d103c250fa5003c250e1002a50ca5000000452407] 2020/05/06 08:09:57 RX: [c13e62030000f500003d240c] 2020/05/06 08:09:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 08:09:57 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 08:10:00 RX: [c1007339005fcb66004a04101a000000451003] 2020/05/06 08:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 08:10:37 RX: [c13e62030000f500003e240d] 2020/05/06 08:10:37 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 08:12:13 RX: [c10f620300011700003d2501] 2020/05/06 08:12:13 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 08:12:14 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 08:12:14 RX: [c11870000100000000441004] 2020/05/06 08:12:14 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 08:13:38 RX: [c137620400421e66662d2400] 2020/05/06 08:13:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.6 2020/05/06 08:13:57 RX: [c13a62170000c400c13d240f] 2020/05/06 08:13:57 dropping wheel position on the ground: 19.3 2020/05/06 08:13:57 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/06 08:14:37 RX: [c13e62030000fa00003d240e] 2020/05/06 08:14:37 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 08:14:49 RX: [c10c620300010b00002e2405] 2020/05/06 08:14:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 08:14:49 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 08:14:49 RX: [c11470000100000000341000] 2020/05/06 08:14:49 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 08:15:17 RX: [c13b620400422ecccd3e2403] 2020/05/06 08:15:17 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.7 2020/05/06 08:15:59 RX: [c13c624200121bfa103e2403a5002e24051003a50ca5000000452408] 2020/05/06 08:15:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:15:59 Message not handled [c13c624200121bfa103e2403a5002e24051003a50ca5000000452408] 2020/05/06 08:16:26 RX: [c115620300010e0000482503] 2020/05/06 08:16:26 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 08:16:26 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 08:16:26 RX: [c110700001000000004c1003] 2020/05/06 08:16:26 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal weak, cyclic false) status switched on 2020/05/06 08:17:20 RX: [c10f620300012200003c2502] 2020/05/06 08:17:20 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 08:20:39 RX: [c1096204004236cccd2e240b] 2020/05/06 08:20:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 45.7 2020/05/06 08:22:14 RX: [c13c6242001295ea102e240ba5004825031003a50ca5000000462409] 2020/05/06 08:22:14 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:22:14 Message not handled [c13c6242001295ea102e240ba5004825031003a50ca5000000462409] 2020/05/06 08:23:59 RX: [c10c620300011300002e2406] 2020/05/06 08:23:59 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.5 2020/05/06 08:23:59 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 08:23:59 RX: [c11470000000000000351002] 2020/05/06 08:23:59 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 08:24:32 RX: [c10f620300012900003b2503] 2020/05/06 08:24:32 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 08:24:32 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 08:24:33 RX: [c11870000000000000451006] 2020/05/06 08:24:33 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 08:25:16 RX: [c11762030000cf0000482500] 2020/05/06 08:25:16 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 20.7 2020/05/06 08:25:40 RX: [c133620300ffff0000352402] 2020/05/06 08:25:40 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 08:25:57 RX: [c13e62030000ff00003d240f] 2020/05/06 08:25:57 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 08:25:57 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 08:26:58 RX: [c13662170000cf00b52e240b] 2020/05/06 08:26:58 dropping wheel position on the ground: 18.1 2020/05/06 08:26:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 08:27:38 RX: [c13f62030000fa00002e240b] 2020/05/06 08:27:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 08:28:09 RX: [c10162170000e800de2e2404] 2020/05/06 08:28:09 dropping wheel position on the ground: 22.2 2020/05/06 08:28:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 08:30:32 RX: [c10f620300012200003b2504] 2020/05/06 08:30:32 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 08:31:40 RX: [c1356204004257333336240b] 2020/05/06 08:31:40 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 53.8 2020/05/06 08:32:19 RX: [c10c620300011600002e2407] 2020/05/06 08:32:19 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.8 2020/05/06 08:32:20 RX: [c13462170000ca000036240c] 2020/05/06 08:32:20 dropping wheel position on the ground: 0.0 2020/05/06 08:32:20 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 08:36:33 RX: [c10f620300011700003c2505] 2020/05/06 08:36:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 08:36:33 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 08:36:34 RX: [c11870000100000000421008] 2020/05/06 08:36:34 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 08:36:58 RX: [c13f62030000f500002d240c] 2020/05/06 08:36:58 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 08:36:58 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 08:39:44 RX: [c13c624200120fcb102d240ca5003c25051003a50ca500000047240a] 2020/05/06 08:39:44 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:39:44 Message not handled [c13c624200120fcb102d240ca5003c25051003a50ca500000047240a] 2020/05/06 08:41:41 RX: [c10f620300012200003c2507] 2020/05/06 08:41:41 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 08:41:56 RX: [c13e620300010000003c2400] 2020/05/06 08:41:56 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 08:43:09 RX: [c10c620300010f00002e2408] 2020/05/06 08:43:09 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/06 08:43:38 RX: [c137620400421e00002e2401] 2020/05/06 08:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.5 2020/05/06 08:43:56 RX: [c13a62170000c600c13d2400] 2020/05/06 08:43:56 dropping wheel position on the ground: 19.3 2020/05/06 08:43:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/06 08:45:16 RX: [c13b620400422f33333d2404] 2020/05/06 08:45:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.8 2020/05/06 08:45:59 RX: [c13c6242001281db103d2404a5003c25051003a50ca500000046240b] 2020/05/06 08:45:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:45:59 Message not handled [c13c6242001281db103d2404a5003c25051003a50ca500000046240b] 2020/05/06 08:46:28 RX: [c11562030001110000452505] 2020/05/06 08:46:28 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 08:49:11 RX: [c10f620300012900003c2508] 2020/05/06 08:49:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 08:49:11 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 08:49:12 RX: [c1187000000000000045100a] 2020/05/06 08:49:12 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 08:49:49 RX: [c10c620300010800002e2409] 2020/05/06 08:49:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.4 2020/05/06 08:49:49 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 08:49:49 RX: [c11470000100000000361004] 2020/05/06 08:49:49 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 08:50:39 RX: [c109620400422b999a2e240c] 2020/05/06 08:50:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.9 2020/05/06 08:52:15 RX: [c13c624200123398102e240ca5002e24091003a50ca500000045240c] 2020/05/06 08:52:15 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 08:52:15 Message not handled [c13c624200123398102e240ca5002e24091003a50ca500000045240c] 2020/05/06 08:55:11 RX: [c10f620300012200003c2509] 2020/05/06 08:55:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 08:55:18 RX: [c11762030000d20000482502] 2020/05/06 08:55:18 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 08:55:39 RX: [c133620300ffff0000372403] 2020/05/06 08:55:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 08:56:29 RX: [c115620300011c0000492507] 2020/05/06 08:56:29 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.4 2020/05/06 08:56:30 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 08:56:30 RX: [c110700000000000004c1005] 2020/05/06 08:56:30 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal weak, cyclic false) status switched off 2020/05/06 08:56:58 RX: [c13662170000d000b52d240c] 2020/05/06 08:56:58 dropping wheel position on the ground: 18.1 2020/05/06 08:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 08:58:09 RX: [c10162170000e900de2d2405] 2020/05/06 08:58:09 dropping wheel position on the ground: 22.2 2020/05/06 08:58:09 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 08:58:18 RX: [c13f62030000f600002d240d] 2020/05/06 08:58:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 08:59:06 RX: [c10f620300011700003c250a] 2020/05/06 08:59:06 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 08:59:06 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 08:59:06 RX: [c1187000010000000041100c] 2020/05/06 08:59:06 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 08:59:35 RX: [c13c623f00ed01b50041100ca5003c250a1003a50ca500000046240d] 2020/05/06 08:59:35 (partially decoded) temp 18.1C moisture 49.3% 2020/05/06 08:59:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/06 08:59:35 Message not handled [c13c623f00ed01b50041100ca5003c250a1003a50ca500000046240d] 2020/05/06 08:59:45 RX: [c13c624200ed27a91041100ca5003c250a1003a50ca500000046240e] 2020/05/06 08:59:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 08:59:45 Message not handled [c13c624200ed27a91041100ca5003c250a1003a50ca500000046240e] 2020/05/06 08:59:49 RX: [c10c620300011000002e240a] 2020/05/06 08:59:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 09:00:00 RX: [c1007339005fcb66004a042019000000451004] 2020/05/06 09:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 09:01:39 RX: [c1356204004255333337240c] 2020/05/06 09:01:39 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 53.3 2020/05/06 09:01:56 RX: [c13e62030000fb00003c2401] 2020/05/06 09:01:56 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 09:02:19 RX: [c13462170000cb000037240d] 2020/05/06 09:02:19 dropping wheel position on the ground: 0.0 2020/05/06 09:02:19 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/06 09:03:54 RX: [c10f620300012200003c250b] 2020/05/06 09:03:54 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 09:04:49 RX: [c10c620300011700002e240b] 2020/05/06 09:04:49 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 09:04:49 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 09:04:49 RX: [c11470000000000000351006] 2020/05/06 09:04:49 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 09:05:39 RX: [c10c620300011900002e240c] 2020/05/06 09:05:39 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28.1 2020/05/06 09:06:01 RX: [c13c62420012a9b9102e240ca5002e240b1004a50ca500000047240f] 2020/05/06 09:06:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 09:06:01 Message not handled [c13c62420012a9b9102e240ca5002e240b1004a50ca500000047240f] 2020/05/06 09:10:00 RX: [c1007339005fcb66004a04101a000000461005] 2020/05/06 09:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 09:11:26 RX: [c10f620300012900003c250d] 2020/05/06 09:11:26 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 09:11:26 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 09:11:26 RX: [c1187000000000000045100e] 2020/05/06 09:11:26 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 09:12:16 RX: [c13c624200274b3e1045100ea5003c250d1005a50ca5000000472400] 2020/05/06 09:12:16 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 09:12:16 Message not handled [c13c624200274b3e1045100ea5003c250d1005a50ca5000000472400] 2020/05/06 09:12:36 RX: [c13e62030000fd00003e2402] 2020/05/06 09:12:36 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 09:13:38 RX: [c137620400421a66662e2402] 2020/05/06 09:13:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.6 2020/05/06 09:13:56 RX: [c13a62170000c700c13d2401] 2020/05/06 09:13:56 dropping wheel position on the ground: 19.3 2020/05/06 09:13:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/06 09:15:16 RX: [c13b620400422c66663d2405] 2020/05/06 09:15:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.1 2020/05/06 09:17:26 RX: [c10f620300012200003c250e] 2020/05/06 09:17:26 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 09:18:09 RX: [c10c620300011200002e240d] 2020/05/06 09:18:09 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 09:20:39 RX: [c109620400421ecccd2e240d] 2020/05/06 09:20:39 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.7 2020/05/06 09:21:56 RX: [c10f620300011700003c250f] 2020/05/06 09:21:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 09:21:56 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 09:21:57 RX: [c11870000100000000411000] 2020/05/06 09:21:57 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 09:25:20 RX: [c11762030000d20000472504] 2020/05/06 09:25:20 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 09:25:39 RX: [c133620300ffff0000382404] 2020/05/06 09:25:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 09:25:51 RX: [c10f620300012200003c2500] 2020/05/06 09:25:51 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 09:26:31 RX: [c11562030001150000492509] 2020/05/06 09:26:31 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.7 2020/05/06 09:26:58 RX: [c13662170000d000b52d240d] 2020/05/06 09:26:58 dropping wheel position on the ground: 18.1 2020/05/06 09:26:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 09:28:08 RX: [c10162170000e900de2d2406] 2020/05/06 09:28:08 dropping wheel position on the ground: 22.2 2020/05/06 09:28:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 09:28:18 RX: [c13f62030000fa00002d240e] 2020/05/06 09:28:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 09:29:46 RX: [c13c62420012c52e102d240ea5003c250f1005a50ca5000000462401] 2020/05/06 09:29:46 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 09:29:46 Message not handled [c13c62420012c52e102d240ea5003c250f1005a50ca5000000462401] 2020/05/06 09:31:39 RX: [c1356204004252666637240d] 2020/05/06 09:31:39 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 52.6 2020/05/06 09:32:19 RX: [c13462170000cc000036240e] 2020/05/06 09:32:19 dropping wheel position on the ground: 0.0 2020/05/06 09:32:19 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/06 09:33:58 RX: [c10c620300010b00002d240e] 2020/05/06 09:33:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 09:33:59 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 09:33:59 RX: [c11470000100000000351008] 2020/05/06 09:33:59 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 09:35:09 RX: [c10f620300012900003c2501] 2020/05/06 09:35:09 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 09:35:09 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 09:35:10 RX: [c11870000000000000441002] 2020/05/06 09:35:10 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 09:36:01 RX: [c13c624200275f0f10441002a5003c25011005a50ca5000000472402] 2020/05/06 09:36:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 09:36:01 Message not handled [c13c624200275f0f10441002a5003c25011005a50ca5000000472402] 2020/05/06 09:36:36 RX: [c13e62030000f800003c2403] 2020/05/06 09:36:36 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 09:37:18 RX: [c10c620300010b00002d240f] 2020/05/06 09:37:18 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 09:41:11 RX: [c10f620300012200003b2503] 2020/05/06 09:41:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 09:42:17 RX: [c13c62420012d11f103b2503a5003c25011005a50ca5000000462403] 2020/05/06 09:42:17 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 09:42:17 Message not handled [c13c62420012d11f103b2503a5003c25011005a50ca5000000462403] 2020/05/06 09:43:08 RX: [c10c620300011300002d2400] 2020/05/06 09:43:08 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.5 2020/05/06 09:43:09 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 09:43:09 RX: [c1147000000000000035100a] 2020/05/06 09:43:09 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 09:43:16 RX: [c13e62030000fc00003c2404] 2020/05/06 09:43:16 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 09:43:38 RX: [c137620400421466662d2403] 2020/05/06 09:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.1 2020/05/06 09:43:56 RX: [c13a62170000c700c13d2402] 2020/05/06 09:43:56 dropping wheel position on the ground: 19.3 2020/05/06 09:43:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/06 09:45:16 RX: [c13b620400422933333c2406] 2020/05/06 09:45:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.3 2020/05/06 09:47:11 RX: [c10f620300011b00003c2504] 2020/05/06 09:47:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 09:47:11 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 09:47:12 RX: [c11870000100000000411004] 2020/05/06 09:47:12 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 09:48:57 RX: [c13c623f00e801b700411004a5003c25041005a50ca5000000462404] 2020/05/06 09:48:57 (partially decoded) temp 18.3C moisture 48.8% 2020/05/06 09:48:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/06 09:48:57 Message not handled [c13c623f00e801b700411004a5003c25041005a50ca5000000462404] 2020/05/06 09:49:37 RX: [c13c623f00e901b700411004a5003c25041005a50ca5000000472405] 2020/05/06 09:49:37 (partially decoded) temp 18.3C moisture 48.9% 2020/05/06 09:49:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/06 09:49:37 Message not handled [c13c623f00e901b700411004a5003c25041005a50ca5000000472405] 2020/05/06 09:49:47 RX: [c13c624200e9776d10411004a5003c25041005a50ca5000000472406] 2020/05/06 09:49:47 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 09:49:47 Message not handled [c13c624200e9776d10411004a5003c25041005a50ca5000000472406] 2020/05/06 09:50:38 RX: [c1096204004215999a2d240e] 2020/05/06 09:50:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.4 2020/05/06 09:53:11 RX: [c10f620300012200003b2505] 2020/05/06 09:53:11 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 09:55:22 RX: [c11762030000d20000472506] 2020/05/06 09:55:22 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 09:55:39 RX: [c133620300ffff0000382405] 2020/05/06 09:55:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 09:56:03 RX: [c13c62420012f97d10382405a5003c25041005a50ca5000000472407] 2020/05/06 09:56:03 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 09:56:03 Message not handled [c13c62420012f97d10382405a5003c25041005a50ca5000000472407] 2020/05/06 09:56:33 RX: [c1156203000111000049250b] 2020/05/06 09:56:33 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 09:56:58 RX: [c13662170000d300b52d240e] 2020/05/06 09:56:58 dropping wheel position on the ground: 18.1 2020/05/06 09:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 09:57:16 RX: [c13e62030000f700003c2405] 2020/05/06 09:57:16 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 09:57:16 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 09:58:08 RX: [c10162170000ea00de2d2407] 2020/05/06 09:58:08 dropping wheel position on the ground: 22.2 2020/05/06 09:58:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 09:58:18 RX: [c13f62030000fd00002d240f] 2020/05/06 09:58:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 09:58:18 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 10:00:00 RX: [c1007339005fcb66004a042019000000471006] 2020/05/06 10:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 10:01:39 RX: [c135620400424f999a36240e] 2020/05/06 10:01:39 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.9 2020/05/06 10:02:18 RX: [c13c624200121bfa1036240ea5000000471006a50ca5000000472408] 2020/05/06 10:02:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:02:18 Message not handled [c13c624200121bfa1036240ea5000000471006a50ca5000000472408] 2020/05/06 10:02:19 RX: [c13462170000cc000037240f] 2020/05/06 10:02:19 dropping wheel position on the ground: 0.0 2020/05/06 10:02:19 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/06 10:08:08 RX: [c10c620300010e00002d2401] 2020/05/06 10:08:08 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 10:08:36 RX: [c13e62030000fc00003c2406] 2020/05/06 10:08:36 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 10:08:58 RX: [c13c623f00f701b8003c2406a5000000471006a50ca5000000462409] 2020/05/06 10:08:58 (partially decoded) temp 18.4C moisture 50.3% 2020/05/06 10:08:58 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 10:08:58 Message not handled [c13c623f00f701b8003c2406a5000000471006a50ca5000000462409] 2020/05/06 10:10:00 RX: [c1007339005fcb66004a04101a000000451007] 2020/05/06 10:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 10:12:44 RX: [c10f620300013300003c2508] 2020/05/06 10:12:44 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30.7 2020/05/06 10:12:44 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 10:12:44 RX: [c11870000000000000451006] 2020/05/06 10:12:44 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 10:13:38 RX: [c1376204004210cccd2d2404] 2020/05/06 10:13:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.2 2020/05/06 10:13:56 RX: [c13a62170000c800c13c2403] 2020/05/06 10:13:56 dropping wheel position on the ground: 19.3 2020/05/06 10:13:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 10:14:36 RX: [c13e62030000fd00003d2407] 2020/05/06 10:14:36 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 10:14:36 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 10:15:16 RX: [c13b620400422733333c2407] 2020/05/06 10:15:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.8 2020/05/06 10:16:56 RX: [c10f620300012900003c2509] 2020/05/06 10:16:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 10:17:56 RX: [c13e620300010600003d2408] 2020/05/06 10:17:56 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.2 2020/05/06 10:18:18 RX: [c13c623f00f801b7003d2408a5003c25081007a50ca500000047240a] 2020/05/06 10:18:18 (partially decoded) temp 18.3C moisture 50.4% 2020/05/06 10:18:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 10:18:18 Message not handled [c13c623f00f801b7003d2408a5003c25081007a50ca500000047240a] 2020/05/06 10:19:48 RX: [c13c624200f881db103d2408a5003c25081007a50ca500000046240b] 2020/05/06 10:19:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:19:48 Message not handled [c13c624200f881db103d2408a5003c25081007a50ca500000046240b] 2020/05/06 10:20:38 RX: [c109620400420e00002d240f] 2020/05/06 10:20:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.5 2020/05/06 10:22:56 RX: [c10f620300012200003c250a] 2020/05/06 10:22:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 10:25:24 RX: [c11762030000d20000472508] 2020/05/06 10:25:24 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 10:25:39 RX: [c133620300ffff0000372406] 2020/05/06 10:25:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 10:26:03 RX: [c13c62420012339810372406a5003c25081007a50ca500000047240c] 2020/05/06 10:26:03 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:26:03 Message not handled [c13c62420012339810372406a5003c25081007a50ca500000047240c] 2020/05/06 10:26:35 RX: [c115620300010e000049250d] 2020/05/06 10:26:35 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 10:26:35 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 10:26:36 RX: [c11070000100000000491007] 2020/05/06 10:26:36 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 10:26:58 RX: [c13662170000d300b52d240f] 2020/05/06 10:26:58 dropping wheel position on the ground: 18.1 2020/05/06 10:26:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 10:28:08 RX: [c10162170000ea00de2d2408] 2020/05/06 10:28:08 dropping wheel position on the ground: 22.2 2020/05/06 10:28:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 10:28:18 RX: [c13f62030000fc00002d2400] 2020/05/06 10:28:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 10:28:39 RX: [c10f620300011700003c250b] 2020/05/06 10:28:39 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 10:28:39 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 10:28:39 RX: [c11870000100000000421008] 2020/05/06 10:28:39 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 10:31:39 RX: [c135620400424c666636240f] 2020/05/06 10:31:39 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.1 2020/05/06 10:32:18 RX: [c10c620300010700002d2402] 2020/05/06 10:32:18 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/06 10:32:18 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 10:32:19 RX: [c13c62420002bd88102d2402a5003c250b1007a50ca500000046240d] 2020/05/06 10:32:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:32:19 Message not handled [c13c62420002bd88102d2402a5003c250b1007a50ca500000046240d] 2020/05/06 10:32:19 RX: [c1147000010000000036100c] 2020/05/06 10:32:19 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 10:32:19 RX: [c13462170000cd0000372400] 2020/05/06 10:32:19 dropping wheel position on the ground: 0.0 2020/05/06 10:32:19 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 10:32:33 RX: [c10f620300012200003c250c] 2020/05/06 10:32:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 10:32:36 RX: [c13e62030000ff00003c2409] 2020/05/06 10:32:36 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 10:38:33 RX: [c10f620300012900003c250d] 2020/05/06 10:38:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 10:38:33 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 10:38:34 RX: [c1187000000000000045100a] 2020/05/06 10:38:34 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 10:38:58 RX: [c10c620300010c00002d2403] 2020/05/06 10:38:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.8 2020/05/06 10:39:39 RX: [c13c623f00f601b8002d2403a5003c250d1007a50ca500000047240e] 2020/05/06 10:39:39 (partially decoded) temp 18.4C moisture 50.2% 2020/05/06 10:39:39 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 10:39:39 Message not handled [c13c623f00f601b8002d2403a5003c250d1007a50ca500000047240e] 2020/05/06 10:39:49 RX: [c13c624200f6a9b9102d2403a5003c250d1007a50ca500000047240f] 2020/05/06 10:39:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:39:49 Message not handled [c13c624200f6a9b9102d2403a5003c250d1007a50ca500000047240f] 2020/05/06 10:43:38 RX: [c137620400420e66662d2405] 2020/05/06 10:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.6 2020/05/06 10:43:56 RX: [c13a62170000c900c13e2404] 2020/05/06 10:43:56 dropping wheel position on the ground: 19.3 2020/05/06 10:43:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 10:44:48 RX: [c10c620300011400002d2404] 2020/05/06 10:44:48 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 10:44:48 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 10:44:49 RX: [c1147000000000000035100e] 2020/05/06 10:44:49 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 10:44:58 RX: [c13f620300010100002d2401] 2020/05/06 10:44:58 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 10:45:16 RX: [c13b620400422333333c2408] 2020/05/06 10:45:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.8 2020/05/06 10:45:48 RX: [c10f620300012200003c250f] 2020/05/06 10:45:48 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 10:45:56 RX: [c13e620300010100003e240a] 2020/05/06 10:45:56 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 10:46:04 RX: [c13c624200124b3e103e240aa5002d24041007a50ca5000000462400] 2020/05/06 10:46:04 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:46:04 Message not handled [c13c624200124b3e103e240aa5002d24041007a50ca5000000462400] 2020/05/06 10:48:18 RX: [c13f62030000f800002d2402] 2020/05/06 10:48:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 10:50:38 RX: [c109620400420000002d2400] 2020/05/06 10:50:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32 2020/05/06 10:51:30 RX: [c10f620300011700003c2500] 2020/05/06 10:51:30 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 10:51:30 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 10:51:31 RX: [c1187000010000000042100c] 2020/05/06 10:51:31 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 10:52:18 RX: [c10c620300011b00002d2405] 2020/05/06 10:52:18 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 10:52:20 RX: [c13c62420012c52e102d2405a5003c25001007a50ca5000000462401] 2020/05/06 10:52:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 10:52:20 Message not handled [c13c62420012c52e102d2405a5003c25001007a50ca5000000462401] 2020/05/06 10:52:52 RX: [c1156203000119000049250f] 2020/05/06 10:52:52 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 10:52:52 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 10:52:53 RX: [c110700000000000004a1009] 2020/05/06 10:52:53 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 10:53:38 RX: [c13f62030000fe00002e2403] 2020/05/06 10:53:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 10:55:24 RX: [c10f620300012200003c2501] 2020/05/06 10:55:24 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 10:55:26 RX: [c11762030000d6000047250a] 2020/05/06 10:55:26 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 10:55:39 RX: [c133620300ffff0000362407] 2020/05/06 10:55:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 10:56:28 RX: [c10c620300011400002d2406] 2020/05/06 10:56:28 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 10:56:58 RX: [c13662170000d200b52d2400] 2020/05/06 10:56:58 dropping wheel position on the ground: 18.1 2020/05/06 10:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 10:58:08 RX: [c10162170000e800de2d2409] 2020/05/06 10:58:08 dropping wheel position on the ground: 22.2 2020/05/06 10:58:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 10:59:40 RX: [c13c623f00fc01b9002d2409a50049250f1007a50ca5000000452402] 2020/05/06 10:59:40 (partially decoded) temp 18.5C moisture 50.8% 2020/05/06 10:59:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 10:59:40 Message not handled [c13c623f00fc01b9002d2409a50049250f1007a50ca5000000452402] 2020/05/06 11:00:00 RX: [c1007339005fcb66004a042019000000461008] 2020/05/06 11:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 11:00:18 RX: [c13f62030000fb00002d2404] 2020/05/06 11:00:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 11:01:39 RX: [c1356204004245999a362400] 2020/05/06 11:01:39 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 49.4 2020/05/06 11:02:19 RX: [c13462170000cd0000352401] 2020/05/06 11:02:19 dropping wheel position on the ground: 0.0 2020/05/06 11:02:19 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 11:02:20 RX: [c13c623f00fa01b900352401a5000000461008a50ca5000000452403] 2020/05/06 11:02:20 (partially decoded) temp 18.5C moisture 50.6% 2020/05/06 11:02:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 11:02:20 Message not handled [c13c623f00fa01b900352401a5000000461008a50ca5000000452403] 2020/05/06 11:03:13 RX: [c10f620300012900003b2502] 2020/05/06 11:03:13 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 11:03:13 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 11:03:13 RX: [c1187000000000000043100e] 2020/05/06 11:03:13 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 11:07:18 RX: [c10c620300010d00002d2407] 2020/05/06 11:07:18 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/06 11:09:31 RX: [c10f620300012200003b2503] 2020/05/06 11:09:31 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 11:09:49 RX: [c13c62420012635c103b2503a5003b25021008a50ca5000000472404] 2020/05/06 11:09:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 11:09:49 Message not handled [c13c62420012635c103b2503a5003b25021008a50ca5000000472404] 2020/05/06 11:10:00 RX: [c1007339005fcb66004a04101a000000451009] 2020/05/06 11:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 11:12:18 RX: [c10c620300010e00002d2408] 2020/05/06 11:12:18 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 11:13:38 RX: [c1376204004206cccd2d2406] 2020/05/06 11:13:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.7 2020/05/06 11:13:56 RX: [c13a62170000c800c13c2405] 2020/05/06 11:13:56 dropping wheel position on the ground: 19.3 2020/05/06 11:13:56 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 11:15:16 RX: [c13b620400421a00003c2409] 2020/05/06 11:15:16 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.5 2020/05/06 11:15:33 RX: [c10f620300011b00003b2505] 2020/05/06 11:15:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 11:15:33 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 11:15:33 RX: [c11870000100000000431000] 2020/05/06 11:15:33 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 11:15:56 RX: [c13e62030000ff00003d240b] 2020/05/06 11:15:56 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 11:16:05 RX: [c13c62420012ed4c103d240ba5003b25051009a50ca5000000452405] 2020/05/06 11:16:05 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:16:05 Message not handled [c13c62420012ed4c103d240ba5003b25051009a50ca5000000452405] 2020/05/06 11:20:03 RX: [c10f620300012500003b2506] 2020/05/06 11:20:03 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 11:20:03 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 11:20:04 RX: [c11870000000000000431002] 2020/05/06 11:20:04 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 11:20:38 RX: [c109620400420733332d2401] 2020/05/06 11:20:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.8 2020/05/06 11:22:21 RX: [c13c62420012776d102d2401a5003b25061009a50ca5000000452406] 2020/05/06 11:22:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:22:21 Message not handled [c13c62420012776d102d2401a5003b25061009a50ca5000000452406] 2020/05/06 11:22:54 RX: [c11562030001110000482501] 2020/05/06 11:22:54 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 11:25:28 RX: [c11762030000d2000045250c] 2020/05/06 11:25:28 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 11:25:39 RX: [c133620300ffff0000382408] 2020/05/06 11:25:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 11:26:57 RX: [c10f620300011e00003c2507] 2020/05/06 11:26:57 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 11:26:57 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 11:26:58 RX: [c13662170000d000b52d2401] 2020/05/06 11:26:58 dropping wheel position on the ground: 18.1 2020/05/06 11:26:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 11:26:59 RX: [c11870000100000000431004] 2020/05/06 11:26:59 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 11:28:08 RX: [c10162170000e800de2d240a] 2020/05/06 11:28:08 dropping wheel position on the ground: 22.2 2020/05/06 11:28:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 11:29:41 RX: [c13c623f00f501ba002d240aa5002d24011009a50ca5000000462407] 2020/05/06 11:29:41 (partially decoded) temp 18.6C moisture 50.1% 2020/05/06 11:29:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 11:29:41 Message not handled [c13c623f00f501ba002d240aa5002d24011009a50ca5000000462407] 2020/05/06 11:29:51 RX: [c13c624200f51bfa102d240aa5002d24011009a50ca5000000452408] 2020/05/06 11:29:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:29:51 Message not handled [c13c624200f51bfa102d240aa5002d24011009a50ca5000000452408] 2020/05/06 11:30:18 RX: [c13f62030000f800002d2405] 2020/05/06 11:30:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 11:30:35 RX: [c13e62030000f900003d240c] 2020/05/06 11:30:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 11:30:38 RX: [c10c620300010600002d2409] 2020/05/06 11:30:38 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.2 2020/05/06 11:30:38 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 11:30:39 RX: [c11470000100000000361000] 2020/05/06 11:30:39 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 11:31:38 RX: [c135620400423c6666362401] 2020/05/06 11:31:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 47.1 2020/05/06 11:32:18 RX: [c13462170000cd0000362402] 2020/05/06 11:32:18 dropping wheel position on the ground: 0.0 2020/05/06 11:32:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 11:32:58 RX: [c10f620300012500003c2508] 2020/05/06 11:32:58 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 11:32:58 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 11:32:58 RX: [c11870000000000000431006] 2020/05/06 11:32:58 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 11:33:55 RX: [c13e62030000fe00003c240d] 2020/05/06 11:33:55 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 11:36:06 RX: [c13c6242001295ea103c240da5003c25081009a50ca5000000452409] 2020/05/06 11:36:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:36:06 Message not handled [c13c6242001295ea103c240da5003c25081009a50ca5000000452409] 2020/05/06 11:39:48 RX: [c10c620300010e00002d240a] 2020/05/06 11:39:48 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 11:42:18 RX: [c13f62030000f300002d2406] 2020/05/06 11:42:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.3 2020/05/06 11:42:18 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 11:42:22 RX: [c13c624200120fcb102d2406a5003c25081009a50ca500000044240a] 2020/05/06 11:42:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:42:22 Message not handled [c13c624200120fcb102d2406a5003c25081009a50ca500000044240a] 2020/05/06 11:42:53 RX: [c10f620300011e00003c250a] 2020/05/06 11:42:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 11:42:54 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 11:42:54 RX: [c11870000100000000421008] 2020/05/06 11:42:54 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 11:43:38 RX: [c137620400420266662d2407] 2020/05/06 11:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.6 2020/05/06 11:43:55 RX: [c13a62170000c900c13c2406] 2020/05/06 11:43:55 dropping wheel position on the ground: 19.3 2020/05/06 11:43:55 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 11:43:58 RX: [c10c620300011600002d240b] 2020/05/06 11:43:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.8 2020/05/06 11:43:58 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 11:43:58 RX: [c11470000000000000351002] 2020/05/06 11:43:58 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 11:44:48 RX: [c10c620300011600002d240c] 2020/05/06 11:44:48 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.8 2020/05/06 11:45:15 RX: [c13b620400421400003c240a] 2020/05/06 11:45:15 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37 2020/05/06 11:45:38 RX: [c13f62030000f900002e2407] 2020/05/06 11:45:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 11:47:15 RX: [c13e62030000fc00003c240e] 2020/05/06 11:47:15 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 11:48:54 RX: [c10f620300012500003c250b] 2020/05/06 11:48:54 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 11:48:54 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 11:48:55 RX: [c1187000000000000043100a] 2020/05/06 11:48:55 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 11:50:38 RX: [c1096204004200cccd2d2402] 2020/05/06 11:50:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.2 2020/05/06 11:51:42 RX: [c13c623f00f301ba002d2402a5003c250b1009a50ca500000045240b] 2020/05/06 11:51:42 (partially decoded) temp 18.6C moisture 49.9% 2020/05/06 11:51:42 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 11:51:42 Message not handled [c13c623f00f301ba002d2402a5003c250b1009a50ca500000045240b] 2020/05/06 11:52:56 RX: [c115620300011100004a2503] 2020/05/06 11:52:56 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 11:53:38 RX: [c13f62030000f400002d2408] 2020/05/06 11:53:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 11:55:29 RX: [c11762030000d6000047250e] 2020/05/06 11:55:29 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 11:55:38 RX: [c133620300ffff0000372409] 2020/05/06 11:55:38 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 11:56:58 RX: [c13662170000d000b52d2402] 2020/05/06 11:56:58 dropping wheel position on the ground: 18.1 2020/05/06 11:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 11:57:36 RX: [c10f620300011e00003c250c] 2020/05/06 11:57:36 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 11:57:36 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 11:57:37 RX: [c1187000010000000042100c] 2020/05/06 11:57:37 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 11:58:08 RX: [c10162170000e800de2d240b] 2020/05/06 11:58:08 dropping wheel position on the ground: 22.2 2020/05/06 11:58:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/06 11:58:22 RX: [c13c623f00ed01ba002d240ba5003c250c1009a50ca500000046240c] 2020/05/06 11:58:22 (partially decoded) temp 18.6C moisture 49.3% 2020/05/06 11:58:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 11:58:22 Message not handled [c13c623f00ed01ba002d240ba5003c250c1009a50ca500000046240c] 2020/05/06 11:59:51 RX: [c13c624200edbd88102d240ba5003c250c1009a50ca500000045240d] 2020/05/06 11:59:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 11:59:51 Message not handled [c13c624200edbd88102d240ba5003c250c1009a50ca500000045240d] 2020/05/06 12:00:00 RX: [c1007339005fcb66004a04201900000045100a] 2020/05/06 12:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 12:01:38 RX: [c1356204004235999a372402] 2020/05/06 12:01:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 45.4 2020/05/06 12:02:18 RX: [c13f62030000f700002d2409] 2020/05/06 12:02:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 12:02:18 RX: [c13462170000ce0000372403] 2020/05/06 12:02:18 dropping wheel position on the ground: 0.0 2020/05/06 12:02:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/06 12:03:37 RX: [c10f620300012500003c250d] 2020/05/06 12:03:37 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 12:03:37 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 12:03:37 RX: [c1187000000000000043100e] 2020/05/06 12:03:37 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 12:06:07 RX: [c13c6242002527a91043100ea5003c250d100aa50ca500000045240e] 2020/05/06 12:06:07 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 12:06:07 Message not handled [c13c6242002527a91043100ea5003c250d100aa50ca500000045240e] 2020/05/06 12:06:28 RX: [c10c620300010e00002d240d] 2020/05/06 12:06:28 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 12:07:15 RX: [c13e62030000f700003d240f] 2020/05/06 12:07:15 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 12:07:15 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 12:10:00 RX: [c1007339005fcb66004a04101a00000045100b] 2020/05/06 12:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 12:12:23 RX: [c13c62420052a9b9104a04101a00000045100ba50ca500000047240f] 2020/05/06 12:12:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 12:12:23 Message not handled [c13c62420052a9b9104a04101a00000045100ba50ca500000047240f] 2020/05/06 12:12:35 RX: [c13e62030000fc00003c2400] 2020/05/06 12:12:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 12:13:38 RX: [c137620400420133332d2408] 2020/05/06 12:13:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.3 2020/05/06 12:13:51 RX: [c10f620300011e00003c250f] 2020/05/06 12:13:51 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 12:13:51 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 12:13:52 RX: [c11870000100000000411000] 2020/05/06 12:13:52 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 12:13:55 RX: [c13a62170000c800c13c2407] 2020/05/06 12:13:55 dropping wheel position on the ground: 19.3 2020/05/06 12:13:55 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 12:15:15 RX: [c13b620400421266663d240b] 2020/05/06 12:15:15 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.6 2020/05/06 12:15:38 RX: [c10c620300010e00002d240e] 2020/05/06 12:15:38 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 12:18:35 RX: [c13e620300010000003c2401] 2020/05/06 12:18:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 12:18:35 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 12:19:43 RX: [c13c623f00f101bb003c2401a5003c250f100ba50ca5000000462400] 2020/05/06 12:19:43 (partially decoded) temp 18.7C moisture 49.7% 2020/05/06 12:19:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 12:19:43 Message not handled [c13c623f00f101bb003c2401a5003c250f100ba50ca5000000462400] 2020/05/06 12:19:51 RX: [c10f620300012500003c2500] 2020/05/06 12:19:51 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 12:19:51 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 12:19:52 RX: [c11870000000000000421002] 2020/05/06 12:19:52 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 12:19:53 RX: [c13c62420025c52e10421002a5003c2500100ba50ca5000000462401] 2020/05/06 12:19:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 12:19:53 Message not handled [c13c62420025c52e10421002a5003c2500100ba50ca5000000462401] 2020/05/06 12:20:38 RX: [c10962040041fa66662d2403] 2020/05/06 12:20:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31.3 2020/05/06 12:22:58 RX: [c115620300010e0000492505] 2020/05/06 12:22:58 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 12:22:58 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 12:22:58 RX: [c1107000010000000048100b] 2020/05/06 12:22:58 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 12:25:31 RX: [c11762030000d60000472500] 2020/05/06 12:25:31 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 12:25:38 RX: [c133620300ffff000036240a] 2020/05/06 12:25:38 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 12:26:08 RX: [c13c624200125f0f1036240aa500492505100ba50ca5000000462402] 2020/05/06 12:26:08 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 12:26:08 Message not handled [c13c624200125f0f1036240aa500492505100ba50ca5000000462402] 2020/05/06 12:26:58 RX: [c13662170000d100b52d2403] 2020/05/06 12:26:58 dropping wheel position on the ground: 18.1 2020/05/06 12:26:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.9 2020/05/06 12:28:08 RX: [c10162170000e900de2d240c] 2020/05/06 12:28:08 dropping wheel position on the ground: 22.2 2020/05/06 12:28:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/06 12:30:38 RX: [c10c620300010700002d240f] 2020/05/06 12:30:38 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/06 12:30:38 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 12:30:38 RX: [c11470000100000000361004] 2020/05/06 12:30:38 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 12:31:38 RX: [c1356204004233999a372403] 2020/05/06 12:31:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.9 2020/05/06 12:31:52 RX: [c10f620300011e00003c2501] 2020/05/06 12:31:52 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 12:31:52 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 12:31:52 RX: [c11870000100000000421004] 2020/05/06 12:31:52 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 12:32:18 RX: [c13f62030000fa00002d240a] 2020/05/06 12:32:18 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 12:32:18 RX: [c13462170000ce0000372404] 2020/05/06 12:32:18 dropping wheel position on the ground: 0.0 2020/05/06 12:32:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/06 12:32:23 RX: [c13c62420012d11f10372404a5003c2501100ba50ca5000000462403] 2020/05/06 12:32:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 12:32:23 Message not handled [c13c62420012d11f10372404a5003c2501100ba50ca5000000462403] 2020/05/06 12:37:52 RX: [c10f620300012500003c2502] 2020/05/06 12:37:52 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 12:37:52 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 12:37:53 RX: [c11870000000000000441006] 2020/05/06 12:37:53 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 12:38:08 RX: [c10c620300010e00002d2400] 2020/05/06 12:38:08 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 12:43:38 RX: [c1376204004201999a2d2409] 2020/05/06 12:43:38 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.4 2020/05/06 12:43:55 RX: [c13a62170000c900c13d2408] 2020/05/06 12:43:55 dropping wheel position on the ground: 19.3 2020/05/06 12:43:55 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 12:43:58 RX: [c10c620300011500002d2401] 2020/05/06 12:43:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/06 12:43:58 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 12:43:58 RX: [c11470000000000000361006] 2020/05/06 12:43:58 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 12:45:15 RX: [c13b620400421133333c240c] 2020/05/06 12:45:15 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.3 2020/05/06 12:48:08 RX: [c10c620300011700002d2402] 2020/05/06 12:48:08 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 12:48:35 RX: [c13e62030000ff00003d2402] 2020/05/06 12:48:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 12:49:53 RX: [c13c62420012635c103d2402a5002d2401100ba50ca5000000462404] 2020/05/06 12:49:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 12:49:53 Message not handled [c13c62420012635c103d2402a5002d2401100ba50ca5000000462404] 2020/05/06 12:49:54 RX: [c10f620300011e00003c2504] 2020/05/06 12:49:54 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 12:49:54 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 12:49:55 RX: [c11870000100000000411008] 2020/05/06 12:49:55 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 12:50:38 RX: [c109620400420533332d2404] 2020/05/06 12:50:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.3 2020/05/06 12:53:00 RX: [c11562030001110000492507] 2020/05/06 12:53:00 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 12:55:33 RX: [c11762030000d60000472502] 2020/05/06 12:55:33 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 12:55:38 RX: [c13f62030000ff00002d240b] 2020/05/06 12:55:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 12:55:38 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 12:55:39 RX: [c133620300ffff000036240b] 2020/05/06 12:55:39 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 12:55:54 RX: [c10f620300012500003c2505] 2020/05/06 12:55:54 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 12:55:54 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 12:55:55 RX: [c1187000000000000045100a] 2020/05/06 12:55:55 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 12:56:08 RX: [c13c62420028ed4c1045100aa5003c2505100ba50ca5000000452405] 2020/05/06 12:56:08 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 12:56:08 Message not handled [c13c62420028ed4c1045100aa5003c2505100ba50ca5000000452405] 2020/05/06 12:56:58 RX: [c13662170000d200b52d2404] 2020/05/06 12:56:58 dropping wheel position on the ground: 18.1 2020/05/06 12:56:58 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 12:58:08 RX: [c10162170000ea00de2d240d] 2020/05/06 12:58:08 dropping wheel position on the ground: 22.2 2020/05/06 12:58:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 13:00:00 RX: [c1007339005fcb66004a04201900000044100c] 2020/05/06 13:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 13:01:38 RX: [c135620400422f999a362404] 2020/05/06 13:01:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.9 2020/05/06 13:02:18 RX: [c13462170000cf0000352405] 2020/05/06 13:02:18 dropping wheel position on the ground: 0.0 2020/05/06 13:02:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 13:02:24 RX: [c13c62420012776d10352405a500000044100ca50ca5000000452406] 2020/05/06 13:02:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:02:24 Message not handled [c13c62420012776d10352405a500000044100ca50ca5000000452406] 2020/05/06 13:02:35 RX: [c13e62030000fa00003c2403] 2020/05/06 13:02:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 13:02:57 RX: [c13f62030000fe00002d240c] 2020/05/06 13:02:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 13:03:50 RX: [c115620300011c00004a2508] 2020/05/06 13:03:50 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.4 2020/05/06 13:03:50 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 13:03:51 RX: [c1107000000000000049100d] 2020/05/06 13:03:51 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 13:03:58 RX: [c10c620300011000002e2403] 2020/05/06 13:03:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/06 13:07:01 RX: [c10f620300011e00003d2506] 2020/05/06 13:07:01 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 13:07:01 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 13:07:01 RX: [c1187000010000000041100c] 2020/05/06 13:07:01 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 13:09:45 RX: [c13c623f00e901ba0041100ca5003d2506100ca50ca5000000452407] 2020/05/06 13:09:45 (partially decoded) temp 18.6C moisture 48.9% 2020/05/06 13:09:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/06 13:09:45 Message not handled [c13c623f00e901ba0041100ca5003d2506100ca50ca5000000452407] 2020/05/06 13:09:55 RX: [c13c624200e91bfa1041100ca5003d2506100ca50ca5000000462408] 2020/05/06 13:09:55 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 13:09:55 Message not handled [c13c624200e91bfa1041100ca5003d2506100ca50ca5000000462408] 2020/05/06 13:10:00 RX: [c1007339005fcb66004a04101a00000045100d] 2020/05/06 13:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 13:13:02 RX: [c10f620300012500003c2508] 2020/05/06 13:13:02 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 13:13:02 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 13:13:03 RX: [c1187000000000000043100e] 2020/05/06 13:13:03 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 13:13:37 RX: [c13762040041fccccd2d240a] 2020/05/06 13:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31.6 2020/05/06 13:13:55 RX: [c13a62170000c900c13d2409] 2020/05/06 13:13:55 dropping wheel position on the ground: 19.3 2020/05/06 13:13:55 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 13:15:15 RX: [c13b620400420e00003d240d] 2020/05/06 13:15:15 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.5 2020/05/06 13:16:10 RX: [c13c6242001295ea103d240da5003c2508100da50ca5000000462409] 2020/05/06 13:16:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:16:10 Message not handled [c13c6242001295ea103d240da5003c2508100da50ca5000000462409] 2020/05/06 13:18:58 RX: [c10c620300010e00002d2404] 2020/05/06 13:18:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 13:19:15 RX: [c13e62030000f700003d2404] 2020/05/06 13:19:15 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 13:19:15 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 13:20:38 RX: [c10962040041de66662d2405] 2020/05/06 13:20:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 27.8 2020/05/06 13:22:25 RX: [c13c624200120fcb102d2405a5003c2508100da50ca500000047240a] 2020/05/06 13:22:25 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:22:25 Message not handled [c13c624200120fcb102d2405a5003c2508100da50ca500000047240a] 2020/05/06 13:22:35 RX: [c13e62030000fd00003c2405] 2020/05/06 13:22:35 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 13:22:35 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 13:25:35 RX: [c11762030000d60000472504] 2020/05/06 13:25:35 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 13:25:38 RX: [c133620300ffff000037240c] 2020/05/06 13:25:38 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 13:26:15 RX: [c10f620300011e00003c2509] 2020/05/06 13:26:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 13:26:15 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 13:26:15 RX: [c11870000100000000411000] 2020/05/06 13:26:15 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 13:26:57 RX: [c13662170000d300b52d2405] 2020/05/06 13:26:57 dropping wheel position on the ground: 18.1 2020/05/06 13:26:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 13:28:08 RX: [c10162170000e700de2d240e] 2020/05/06 13:28:08 dropping wheel position on the ground: 22.2 2020/05/06 13:28:08 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/06 13:31:38 RX: [c135620400422b999a372405] 2020/05/06 13:31:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.9 2020/05/06 13:32:15 RX: [c10f620300012500003c250a] 2020/05/06 13:32:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 13:32:15 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 13:32:16 RX: [c11870000000000000431002] 2020/05/06 13:32:16 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 13:32:18 RX: [c13462170000d00000372406] 2020/05/06 13:32:18 dropping wheel position on the ground: 0.0 2020/05/06 13:32:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 13:32:25 RX: [c13c623f00e701ba00372406a5003c250a100da50ca500000047240b] 2020/05/06 13:32:25 (partially decoded) temp 18.6C moisture 48.7% 2020/05/06 13:32:25 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 13:32:25 Message not handled [c13c623f00e701ba00372406a5003c250a100da50ca500000047240b] 2020/05/06 13:32:57 RX: [c13f62030000fe00002d240d] 2020/05/06 13:32:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 13:33:52 RX: [c1156203000119000049250a] 2020/05/06 13:33:52 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 13:39:55 RX: [c13c624200f933981049250aa5003c250a100da50ca500000046240c] 2020/05/06 13:39:55 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 13:39:55 Message not handled [c13c624200f933981049250aa5003c250a100da50ca500000046240c] 2020/05/06 13:42:57 RX: [c13f62030000f900002e240e] 2020/05/06 13:42:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 13:43:37 RX: [c13762040041f333332d240b] 2020/05/06 13:43:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 30.4 2020/05/06 13:43:55 RX: [c13a62170000c900c13d240a] 2020/05/06 13:43:55 dropping wheel position on the ground: 19.3 2020/05/06 13:43:55 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 13:45:15 RX: [c13b620400420e00003d240e] 2020/05/06 13:45:15 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.5 2020/05/06 13:46:10 RX: [c13c62420012bd88103d240ea5003c250a100da50ca500000046240d] 2020/05/06 13:46:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:46:10 Message not handled [c13c62420012bd88103d240ea5003c250a100da50ca500000046240d] 2020/05/06 13:47:53 RX: [c10f620300011e00003c250c] 2020/05/06 13:47:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 13:47:53 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 13:47:54 RX: [c11870000100000000421004] 2020/05/06 13:47:54 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 13:48:58 RX: [c10c620300010f00002e2405] 2020/05/06 13:48:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/06 13:49:37 RX: [c13f62030000fe00002e240f] 2020/05/06 13:49:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 13:49:55 RX: [c13e62030000fa00003f2406] 2020/05/06 13:49:55 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 13:50:38 RX: [c10962040041eb33332d2406] 2020/05/06 13:50:38 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 29.4 2020/05/06 13:52:26 RX: [c13c6242001227a9102d2406a5003c250c100da50ca500000045240e] 2020/05/06 13:52:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:52:26 Message not handled [c13c6242001227a9102d2406a5003c250c100da50ca500000045240e] 2020/05/06 13:53:53 RX: [c10f620300012500003c250d] 2020/05/06 13:53:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 13:53:53 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 13:53:54 RX: [c11870000000000000441006] 2020/05/06 13:53:54 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 13:53:58 RX: [c10c620300010700002d2406] 2020/05/06 13:53:58 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/06 13:53:58 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 13:53:58 RX: [c11470000100000000361008] 2020/05/06 13:53:58 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 13:55:37 RX: [c11762030000d200004b2506] 2020/05/06 13:55:37 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/06 13:55:38 RX: [c133620300ffff000037240d] 2020/05/06 13:55:38 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 13:56:57 RX: [c13662170000d400b52d2406] 2020/05/06 13:56:57 dropping wheel position on the ground: 18.1 2020/05/06 13:56:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 13:57:37 RX: [c13f62030000f800002d2400] 2020/05/06 13:57:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 13:58:07 RX: [c10162170000e300de2e240f] 2020/05/06 13:58:07 dropping wheel position on the ground: 22.2 2020/05/06 13:58:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.7 2020/05/06 13:59:46 RX: [c13c623f00e301ba002e240fa5002d2406100da50ca500000045240f] 2020/05/06 13:59:46 (partially decoded) temp 18.6C moisture 48.3% 2020/05/06 13:59:46 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 13:59:46 Message not handled [c13c623f00e301ba002e240fa5002d2406100da50ca500000045240f] 2020/05/06 13:59:56 RX: [c13c624200e34b3e102e240fa5002d2406100da50ca5000000462400] 2020/05/06 13:59:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 13:59:56 Message not handled [c13c624200e34b3e102e240fa5002d2406100da50ca5000000462400] 2020/05/06 14:00:00 RX: [c1007339005fcb66004a04201900000044100e] 2020/05/06 14:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 14:00:57 RX: [c13f62030000fd00002e2401] 2020/05/06 14:00:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 14:01:27 RX: [c10c620300010e00002d2407] 2020/05/06 14:01:27 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 14:01:38 RX: [c13562040042286666372406] 2020/05/06 14:01:38 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.1 2020/05/06 14:02:18 RX: [c13462170000d10000362407] 2020/05/06 14:02:18 dropping wheel position on the ground: 0.0 2020/05/06 14:02:18 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.9 2020/05/06 14:03:54 RX: [c1156203000111000049250c] 2020/05/06 14:03:54 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 14:05:37 RX: [c13f62030000f900002d2402] 2020/05/06 14:05:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 14:06:12 RX: [c10f620300011e00003b250e] 2020/05/06 14:06:12 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 14:06:12 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 14:06:12 RX: [c13c62420012c52e103b250ea500000044100ea50ca5000000452401] 2020/05/06 14:06:12 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 14:06:12 Message not handled [c13c62420012c52e103b250ea500000044100ea50ca5000000452401] 2020/05/06 14:06:13 RX: [c11870000100000000421008] 2020/05/06 14:06:13 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 14:07:17 RX: [c10c620300011500002d2408] 2020/05/06 14:07:17 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/06 14:07:18 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 14:07:18 RX: [c1147000000000000036100a] 2020/05/06 14:07:18 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 14:10:00 RX: [c1007339005fcb66004a04101a00000044100f] 2020/05/06 14:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 14:12:13 RX: [c10f620300012500003b2500] 2020/05/06 14:12:13 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 14:12:14 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 14:12:14 RX: [c1187000000000000044100a] 2020/05/06 14:12:14 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 14:12:27 RX: [c13c624200255f0f1044100aa5003b2500100fa50ca5000000462402] 2020/05/06 14:12:27 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 14:12:27 Message not handled [c13c624200255f0f1044100aa5003b2500100fa50ca5000000462402] 2020/05/06 14:13:37 RX: [c13762040041f000002d240c] 2020/05/06 14:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 30 2020/05/06 14:13:54 RX: [c13a62170000c900c13c240b] 2020/05/06 14:13:54 dropping wheel position on the ground: 19.3 2020/05/06 14:13:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 14:15:14 RX: [c13b620400420b999a3b240f] 2020/05/06 14:15:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.9 2020/05/06 14:19:54 RX: [c13e62030000fb00003c2407] 2020/05/06 14:19:54 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 14:20:37 RX: [c10962040041e333332d2407] 2020/05/06 14:20:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.4 2020/05/06 14:21:27 RX: [c10c620300011500002d2409] 2020/05/06 14:21:27 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/06 14:25:37 RX: [c133620300ffff000035240e] 2020/05/06 14:25:37 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 14:25:39 RX: [c11762030000d200004c2508] 2020/05/06 14:25:39 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal weak, cyclic true) event 'value' with value 21 2020/05/06 14:26:57 RX: [c13662170000d800b52d2407] 2020/05/06 14:26:57 dropping wheel position on the ground: 18.1 2020/05/06 14:26:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.6 2020/05/06 14:28:07 RX: [c10162170000e100de2d2400] 2020/05/06 14:28:07 dropping wheel position on the ground: 22.2 2020/05/06 14:28:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.5 2020/05/06 14:29:14 RX: [c13e62030000f500003d2408] 2020/05/06 14:29:14 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 14:29:14 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 14:29:56 RX: [c10f620300011e00003b2501] 2020/05/06 14:29:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 14:29:56 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 14:29:57 RX: [c1187000010000000042100c] 2020/05/06 14:29:57 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 14:29:57 RX: [c13c62420022d11f1042100ca5003b2501100fa50ca5000000462403] 2020/05/06 14:29:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 14:29:57 Message not handled [c13c62420022d11f1042100ca5003b2501100fa50ca5000000462403] 2020/05/06 14:31:37 RX: [c1356204004225999a362407] 2020/05/06 14:31:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.4 2020/05/06 14:32:17 RX: [c13462170000d20000372408] 2020/05/06 14:32:17 dropping wheel position on the ground: 0.0 2020/05/06 14:32:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 14:32:34 RX: [c13e62030000fa00003c2409] 2020/05/06 14:32:34 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 14:33:56 RX: [c115620300010e000049250e] 2020/05/06 14:33:56 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 14:33:56 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 14:33:57 RX: [c1107000010000000049100f] 2020/05/06 14:33:57 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 14:35:37 RX: [c13f62030000f900002e2403] 2020/05/06 14:35:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 14:35:56 RX: [c10f620300012500003b2502] 2020/05/06 14:35:56 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 14:35:56 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 14:35:57 RX: [c1187000000000000043100e] 2020/05/06 14:35:57 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 14:36:12 RX: [c13c62420025635c1043100ea5003b2502100fa50ca5000000452404] 2020/05/06 14:36:12 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 14:36:12 Message not handled [c13c62420025635c1043100ea5003b2502100fa50ca5000000452404] 2020/05/06 14:42:28 RX: [c13c62420082ed4c1043100ea5003b2502100fa50ca5000000472405] 2020/05/06 14:42:28 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 14:42:28 Message not handled [c13c62420082ed4c1043100ea5003b2502100fa50ca5000000472405] 2020/05/06 14:43:37 RX: [c13762040041ed999a2d240d] 2020/05/06 14:43:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 14:43:54 RX: [c13a62170000c900c13d240c] 2020/05/06 14:43:54 dropping wheel position on the ground: 19.3 2020/05/06 14:43:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 14:44:34 RX: [c13e62030000ff00003c240a] 2020/05/06 14:44:34 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 14:44:34 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 14:45:14 RX: [c13b620400420b33333d2400] 2020/05/06 14:45:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.8 2020/05/06 14:48:07 RX: [c10c620300010e00002d240a] 2020/05/06 14:48:07 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/06 14:49:48 RX: [c13c623f00e001bb002d240aa5003b2502100fa50ca5000000472406] 2020/05/06 14:49:48 (partially decoded) temp 18.7C moisture 48.0% 2020/05/06 14:49:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 14:49:48 Message not handled [c13c623f00e001bb002d240aa5003b2502100fa50ca5000000472406] 2020/05/06 14:49:58 RX: [c13c624200e0f97d102d240aa5003b2502100fa50ca5000000442407] 2020/05/06 14:49:58 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 14:49:58 Message not handled [c13c624200e0f97d102d240aa5003b2502100fa50ca5000000442407] 2020/05/06 14:50:37 RX: [c10962040041e1999a2d2408] 2020/05/06 14:50:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.2 2020/05/06 14:51:54 RX: [c13e620300010200003c240b] 2020/05/06 14:51:54 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.8 2020/05/06 14:52:17 RX: [c10c620300011100002d240b] 2020/05/06 14:52:17 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/06 14:55:37 RX: [c133620300ffff000037240f] 2020/05/06 14:55:37 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 14:55:41 RX: [c11762030000d600004b250a] 2020/05/06 14:55:41 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 14:56:14 RX: [c13c624200da1bfa104b250aa5003b2502100fa50ca5000000452408] 2020/05/06 14:56:14 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 14:56:14 Message not handled [c13c624200da1bfa104b250aa5003b2502100fa50ca5000000452408] 2020/05/06 14:56:57 RX: [c13662170000d900b52e2408] 2020/05/06 14:56:57 dropping wheel position on the ground: 18.1 2020/05/06 14:56:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.7 2020/05/06 14:58:07 RX: [c10162170000e200de2d2401] 2020/05/06 14:58:07 dropping wheel position on the ground: 22.2 2020/05/06 14:58:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.6 2020/05/06 15:00:00 RX: [c1007339005fcb66004a042019000000461000] 2020/05/06 15:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 15:00:16 RX: [c10f620300011e00003c2504] 2020/05/06 15:00:16 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 15:00:16 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 15:01:37 RX: [c1356204004223999a372408] 2020/05/06 15:01:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.9 2020/05/06 15:02:17 RX: [c13462170000d20000372409] 2020/05/06 15:02:17 dropping wheel position on the ground: 0.0 2020/05/06 15:02:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 15:02:29 RX: [c13c6242001295ea10372409a5000000461000a50ca5000000472409] 2020/05/06 15:02:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 15:02:29 Message not handled [c13c6242001295ea10372409a5000000461000a50ca5000000472409] 2020/05/06 15:02:43 RX: [c11562030001190000492500] 2020/05/06 15:02:43 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 15:02:43 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 15:02:44 RX: [c110700000000000004a1001] 2020/05/06 15:02:44 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 15:04:17 RX: [c13f62030000f400002d2404] 2020/05/06 15:04:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 15:04:17 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 15:06:17 RX: [c10f620300012500003b2505] 2020/05/06 15:06:17 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 15:06:17 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 15:06:17 RX: [c13f62030000f600002d2405] 2020/05/06 15:06:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 15:06:17 RX: [c11870000000000000431002] 2020/05/06 15:06:17 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 15:06:34 RX: [c13e62030000fd00003c240c] 2020/05/06 15:06:34 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 15:09:49 RX: [c13c623f00dd01bb003c240ca5002d24051000a50ca500000046240a] 2020/05/06 15:09:49 (partially decoded) temp 18.7C moisture 47.7% 2020/05/06 15:09:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 15:09:49 Message not handled [c13c623f00dd01bb003c240ca5002d24051000a50ca500000046240a] 2020/05/06 15:10:00 RX: [c1007339005fcb66004a04101a000000441001] 2020/05/06 15:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 15:12:29 RX: [c13c623f00dd01bb004a04101a000000441001a50ca500000046240b] 2020/05/06 15:12:29 (partially decoded) temp 18.7C moisture 47.7% 2020/05/06 15:12:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT OUT 2020/05/06 15:12:29 Message not handled [c13c623f00dd01bb004a04101a000000441001a50ca500000046240b] 2020/05/06 15:13:37 RX: [c13762040041e5999a2d240e] 2020/05/06 15:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.7 2020/05/06 15:13:54 RX: [c13a62170000ca00c13c240d] 2020/05/06 15:13:54 dropping wheel position on the ground: 19.3 2020/05/06 15:13:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 15:15:09 RX: [c13c623f00de01bb003c240da5000000441001a50ca500000047240c] 2020/05/06 15:15:09 (partially decoded) temp 18.7C moisture 47.8% 2020/05/06 15:15:09 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 15:15:09 Message not handled [c13c623f00de01bb003c240da5000000441001a50ca500000047240c] 2020/05/06 15:15:14 RX: [c13b620400420866663c2401] 2020/05/06 15:15:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.1 2020/05/06 15:17:49 RX: [c13c623f00de01ba003c2401a5000000441001a50ca500000047240d] 2020/05/06 15:17:49 (partially decoded) temp 18.6C moisture 47.8% 2020/05/06 15:17:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 15:17:49 Message not handled [c13c623f00de01ba003c2401a5000000441001a50ca500000047240d] 2020/05/06 15:18:34 RX: [c13e620300010200003c240d] 2020/05/06 15:18:34 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.8 2020/05/06 15:19:47 RX: [c10c620300010a00002d240c] 2020/05/06 15:19:47 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.6 2020/05/06 15:19:47 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 15:19:48 RX: [c1147000010000000037100c] 2020/05/06 15:19:48 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 15:19:59 RX: [c13c6242002327a91037100ca5002d240c1001a50ca500000047240e] 2020/05/06 15:19:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 15:19:59 Message not handled [c13c6242002327a91037100ca5002d240c1001a50ca500000047240e] 2020/05/06 15:20:37 RX: [c10962040041dd999a2d2409] 2020/05/06 15:20:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/06 15:20:57 RX: [c13f62030000f100002d2406] 2020/05/06 15:20:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.1 2020/05/06 15:23:07 RX: [c10c620300010c00002d240d] 2020/05/06 15:23:07 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.8 2020/05/06 15:23:14 RX: [c13e62030000ff00003c240e] 2020/05/06 15:23:14 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 15:24:57 RX: [c13f62030000f600002d2407] 2020/05/06 15:24:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 15:25:37 RX: [c133620300ffff0000362400] 2020/05/06 15:25:37 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 15:25:43 RX: [c11762030000d600004b250c] 2020/05/06 15:25:43 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 15:25:49 RX: [c10f620300011e00003c2507] 2020/05/06 15:25:49 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 15:25:49 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 15:25:50 RX: [c11870000100000000421005] 2020/05/06 15:25:50 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 15:26:14 RX: [c13c62420022a9b910421005a5003c25071001a50ca500000045240f] 2020/05/06 15:26:14 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 15:26:14 Message not handled [c13c62420022a9b910421005a5003c25071001a50ca500000045240f] 2020/05/06 15:26:57 RX: [c13662170000da00b52d2409] 2020/05/06 15:26:57 dropping wheel position on the ground: 18.1 2020/05/06 15:26:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.8 2020/05/06 15:28:07 RX: [c10162170000e300de2d2402] 2020/05/06 15:28:07 dropping wheel position on the ground: 22.2 2020/05/06 15:28:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.7 2020/05/06 15:29:47 RX: [c10c620300011400002e240e] 2020/05/06 15:29:47 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 15:29:47 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 15:29:48 RX: [c1147000000000000036100e] 2020/05/06 15:29:48 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 15:31:31 RX: [c10f620300012900003b2508] 2020/05/06 15:31:31 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/06 15:31:31 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 15:31:32 RX: [c11870000000000000441007] 2020/05/06 15:31:32 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 15:31:37 RX: [c13562040042200000362409] 2020/05/06 15:31:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40 2020/05/06 15:32:17 RX: [c13462170000d3000037240a] 2020/05/06 15:32:17 dropping wheel position on the ground: 0.0 2020/05/06 15:32:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 15:32:30 RX: [c13c624200124b3e1037240aa5003b25081001a50ca5000000462400] 2020/05/06 15:32:30 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 15:32:30 Message not handled [c13c624200124b3e1037240aa5003b25081001a50ca5000000462400] 2020/05/06 15:32:45 RX: [c115620300011100004b2502] 2020/05/06 15:32:45 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 15:37:14 RX: [c13e62030000fa00003d240f] 2020/05/06 15:37:14 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 15:37:37 RX: [c13f62030000f900002d2408] 2020/05/06 15:37:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 15:38:57 RX: [c10c620300011b00002d240f] 2020/05/06 15:38:57 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 15:39:50 RX: [c13c623f00da01bb002d240fa5003b25081001a50ca5000000472401] 2020/05/06 15:39:50 (partially decoded) temp 18.7C moisture 47.4% 2020/05/06 15:39:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 15:39:50 Message not handled [c13c623f00da01bb002d240fa5003b25081001a50ca5000000472401] 2020/05/06 15:40:00 RX: [c13c624200da5f0f102d240fa5003b25081001a50ca5000000452402] 2020/05/06 15:40:00 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 15:40:00 Message not handled [c13c624200da5f0f102d240fa5003b25081001a50ca5000000452402] 2020/05/06 15:42:57 RX: [c10f620300012200003b250a] 2020/05/06 15:42:57 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 15:43:37 RX: [c13762040041e733332c240f] 2020/05/06 15:43:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.9 2020/05/06 15:43:54 RX: [c13a62170000ca00c13d240e] 2020/05/06 15:43:54 dropping wheel position on the ground: 19.3 2020/05/06 15:43:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 15:44:47 RX: [c10c620300011400002c2400] 2020/05/06 15:44:47 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 15:45:14 RX: [c13b620400420733333d2402] 2020/05/06 15:45:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.8 2020/05/06 15:46:15 RX: [c13c62420012d11f103d2402a5003b25081001a50ca5000000462403] 2020/05/06 15:46:15 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 15:46:15 Message not handled [c13c62420012d11f103d2402a5003b25081001a50ca5000000462403] 2020/05/06 15:50:37 RX: [c10962040041db33332d240a] 2020/05/06 15:50:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 15:52:31 RX: [c13c62420012635c102d240aa5003b25081001a50ca5000000462404] 2020/05/06 15:52:31 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 15:52:31 Message not handled [c13c62420012635c102d240aa5003b25081001a50ca5000000462404] 2020/05/06 15:52:57 RX: [c13662170000df00b52d240a] 2020/05/06 15:52:57 dropping wheel position on the ground: 18.1 2020/05/06 15:52:57 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.3 2020/05/06 15:53:54 RX: [c13e62030000fc00003d2400] 2020/05/06 15:53:54 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 15:55:37 RX: [c10c620300011300002c2401] 2020/05/06 15:55:37 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.5 2020/05/06 15:55:38 RX: [c133620300ffff0000352401] 2020/05/06 15:55:38 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 15:55:45 RX: [c11762030000d600004a250e] 2020/05/06 15:55:45 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 15:57:37 RX: [c13662170000df00b52d240b] 2020/05/06 15:57:37 dropping wheel position on the ground: 18.1 2020/05/06 15:57:37 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.3 2020/05/06 15:58:07 RX: [c10162170000e100de2d2403] 2020/05/06 15:58:07 dropping wheel position on the ground: 22.2 2020/05/06 15:58:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.5 2020/05/06 16:00:01 RX: [c1007339005fcb66004a042019000000451002] 2020/05/06 16:00:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 16:01:37 RX: [c135620400421f333334240a] 2020/05/06 16:01:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/06 16:01:51 RX: [c13c623f00dd01bb0034240aa5000000451002a50ca5000000472405] 2020/05/06 16:01:51 (partially decoded) temp 18.7C moisture 47.7% 2020/05/06 16:01:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 16:01:51 Message not handled [c13c623f00dd01bb0034240aa5000000451002a50ca5000000472405] 2020/05/06 16:02:17 RX: [c13462170000d4000036240b] 2020/05/06 16:02:17 dropping wheel position on the ground: 0.0 2020/05/06 16:02:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 16:02:47 RX: [c115620300011100004c2504] 2020/05/06 16:02:47 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27.3 2020/05/06 16:06:17 RX: [c13f62030000fe00002e2409] 2020/05/06 16:06:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 16:06:17 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 16:08:17 RX: [c13f62030000fa00002e240a] 2020/05/06 16:08:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 16:10:00 RX: [c13c62420012776d102e240aa5000000451002a50ca5000000472406] 2020/05/06 16:10:00 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 16:10:00 Message not handled [c13c62420012776d102e240aa5000000451002a50ca5000000472406] 2020/05/06 16:10:02 RX: [c1007339005fcb66004a04101a000000441003] 2020/05/06 16:10:02 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 16:12:59 RX: [c10f620300012500003b250c] 2020/05/06 16:12:59 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 16:13:37 RX: [c13762040041e5999a2d2400] 2020/05/06 16:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.7 2020/05/06 16:13:54 RX: [c13a62170000c900c13c240f] 2020/05/06 16:13:54 dropping wheel position on the ground: 19.3 2020/05/06 16:13:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 16:15:14 RX: [c13b620400420866663d2403] 2020/05/06 16:15:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.1 2020/05/06 16:16:16 RX: [c13c62420012f97d103d2403a5000000441003a50ca5000000462407] 2020/05/06 16:16:16 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 16:16:16 Message not handled [c13c62420012f97d103d2403a5000000441003a50ca5000000462407] 2020/05/06 16:20:37 RX: [c10962040041e400002e240b] 2020/05/06 16:20:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.5 2020/05/06 16:20:57 RX: [c13f62030000ff00002d240b] 2020/05/06 16:20:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 16:22:32 RX: [c13c624200121bfa102d240ba5000000441003a50ca5000000462408] 2020/05/06 16:22:32 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 16:22:32 Message not handled [c13c624200121bfa102d240ba5000000441003a50ca5000000462408] 2020/05/06 16:23:07 RX: [c10c620300010c00002e2402] 2020/05/06 16:23:07 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.8 2020/05/06 16:23:54 RX: [c13e62030000fb00003c2401] 2020/05/06 16:23:54 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 16:25:37 RX: [c133620300ffff0000372402] 2020/05/06 16:25:37 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 16:25:46 RX: [c11762030000d600004c2500] 2020/05/06 16:25:46 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal weak, cyclic true) event 'value' with value 21.4 2020/05/06 16:26:17 RX: [c13662170000e400b52e240c] 2020/05/06 16:26:17 dropping wheel position on the ground: 18.1 2020/05/06 16:26:17 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 16:26:27 RX: [c10c620300010d00002d2403] 2020/05/06 16:26:27 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/06 16:28:07 RX: [c10162170000e400de2e2404] 2020/05/06 16:28:07 dropping wheel position on the ground: 22.2 2020/05/06 16:28:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 16:28:17 RX: [c13662170000e400b52d240d] 2020/05/06 16:28:17 dropping wheel position on the ground: 18.1 2020/05/06 16:28:17 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 16:29:52 RX: [c13c623f00df01bb002d240da5000000441003a50ca5000000472409] 2020/05/06 16:29:52 (partially decoded) temp 18.7C moisture 47.9% 2020/05/06 16:29:52 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 16:29:52 Message not handled [c13c623f00df01bb002d240da5000000441003a50ca5000000472409] 2020/05/06 16:30:02 RX: [c13c624200df0fcb102d240da5000000441003a50ca500000047240a] 2020/05/06 16:30:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 16:30:02 Message not handled [c13c624200df0fcb102d240da5000000441003a50ca500000047240a] 2020/05/06 16:31:37 RX: [c135620400421f333336240b] 2020/05/06 16:31:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/06 16:32:17 RX: [c13462170000d4000036240c] 2020/05/06 16:32:17 dropping wheel position on the ground: 0.0 2020/05/06 16:32:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 16:32:49 RX: [c115620300010e00004a2506] 2020/05/06 16:32:49 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 16:32:49 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 16:32:49 RX: [c110700001000000004a1003] 2020/05/06 16:32:49 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 16:36:17 RX: [c13c6242002181db104a1003a5004a25061003a50ca500000047240b] 2020/05/06 16:36:17 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 16:36:17 Message not handled [c13c6242002181db104a1003a5004a25061003a50ca500000047240b] 2020/05/06 16:36:42 RX: [c10f620300012c00003c250d] 2020/05/06 16:36:42 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30 2020/05/06 16:38:57 RX: [c13f620300010000002e240c] 2020/05/06 16:38:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 16:42:33 RX: [c13c624200523398102e240ca5004a25061003a50ca500000044240c] 2020/05/06 16:42:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 16:42:33 Message not handled [c13c624200523398102e240ca5004a25061003a50ca500000044240c] 2020/05/06 16:42:34 RX: [c13e62030000f600003c2402] 2020/05/06 16:42:34 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 16:42:34 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 16:43:37 RX: [c13762040041e333332e2401] 2020/05/06 16:43:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 28.4 2020/05/06 16:43:38 RX: [c13f62030000fb00002e240d] 2020/05/06 16:43:38 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 16:43:54 RX: [c13a62170000ca00c13c2400] 2020/05/06 16:43:54 dropping wheel position on the ground: 19.3 2020/05/06 16:43:54 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/06 16:45:14 RX: [c13b6204004209999a3c2404] 2020/05/06 16:45:14 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.4 2020/05/06 16:45:25 RX: [c10370000000000000471001] 2020/05/06 16:45:25 Device 5734031 (channel 0-'1.etg sov 3') sent message (battery mains-powered, signal normal, cyclic false) value 0 2020/05/06 16:47:14 RX: [c13e62030000fb00003c2403] 2020/05/06 16:47:14 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 16:49:53 RX: [c13c623f00dd01bb003c2403a5003c24041003a50ca500000045240d] 2020/05/06 16:49:53 (partially decoded) temp 18.7C moisture 47.7% 2020/05/06 16:49:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 16:49:53 Message not handled [c13c623f00dd01bb003c2403a5003c24041003a50ca500000045240d] 2020/05/06 16:50:37 RX: [c10962040041df33332d240c] 2020/05/06 16:50:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 16:52:57 RX: [c13f620300010000002d240e] 2020/05/06 16:52:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 16:55:14 RX: [c13e62030000fd00003c2404] 2020/05/06 16:55:14 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 16:55:14 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 16:55:37 RX: [c133620300ffff0000372403] 2020/05/06 16:55:37 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 16:55:48 RX: [c11762030000d600004a2502] 2020/05/06 16:55:48 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/06 16:56:27 RX: [c10c620300010a00002d2404] 2020/05/06 16:56:27 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.6 2020/05/06 16:56:27 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 16:56:27 RX: [c11470000100000000351000] 2020/05/06 16:56:27 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 16:58:07 RX: [c10162170000e400de2e2405] 2020/05/06 16:58:07 dropping wheel position on the ground: 22.2 2020/05/06 16:58:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/06 16:58:17 RX: [c13662170000e600b52e240e] 2020/05/06 16:58:17 dropping wheel position on the ground: 18.1 2020/05/06 16:58:17 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/06 16:58:33 RX: [c13e620300010200003c2405] 2020/05/06 16:58:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.8 2020/05/06 17:00:00 RX: [c1007339005fcb66004a042019000000451004] 2020/05/06 17:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/06 17:00:02 RX: [c13c6242002027a9104a042019000000451004a50ca500000044240e] 2020/05/06 17:00:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 17:00:02 Message not handled [c13c6242002027a9104a042019000000451004a50ca500000044240e] 2020/05/06 17:01:37 RX: [c135620400421ecccd35240c] 2020/05/06 17:01:37 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.7 2020/05/06 17:02:17 RX: [c13462170000d4000036240d] 2020/05/06 17:02:17 dropping wheel position on the ground: 0.0 2020/05/06 17:02:17 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 17:02:51 RX: [c115620300011100004b2508] 2020/05/06 17:02:51 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 17:06:18 RX: [c13c62420017a9b9104b2508a5000000451004a50ca500000045240f] 2020/05/06 17:06:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 17:06:18 Message not handled [c13c62420017a9b9104b2508a5000000451004a50ca500000045240f] 2020/05/06 17:06:44 RX: [c10f620300013000003c250f] 2020/05/06 17:06:44 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30.4 2020/05/06 17:07:17 RX: [c10c620300011200002d2405] 2020/05/06 17:07:17 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 17:07:17 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 17:07:17 RX: [c11470000000000000351002] 2020/05/06 17:07:17 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 17:07:37 RX: [c13f62030000fb00002d240f] 2020/05/06 17:07:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 17:10:00 RX: [c1007339005fcb66004a04101a000000431005] 2020/05/06 17:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/06 17:10:57 RX: [c13f62030000fc00002d2400] 2020/05/06 17:10:57 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 17:11:11 RX: [c115620300011c00004c2509] 2020/05/06 17:11:11 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 28.4 2020/05/06 17:11:11 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 17:11:12 RX: [c110700000000000004b1005] 2020/05/06 17:11:12 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 17:12:34 RX: [c13c624200284b3e104b1005a5004c25091005a50ca5000000462400] 2020/05/06 17:12:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/06 17:12:34 Message not handled [c13c624200284b3e104b1005a5004c25091005a50ca5000000462400] 2020/05/06 17:13:37 RX: [c13762040041fd999a2e2402] 2020/05/06 17:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31.7 2020/05/06 17:13:53 RX: [c13a62170000cc00c13c2401] 2020/05/06 17:13:53 dropping wheel position on the ground: 19.3 2020/05/06 17:13:53 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/06 17:14:33 RX: [c13e62030000fd00003c2406] 2020/05/06 17:14:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 17:15:13 RX: [c13b620400421200003c2405] 2020/05/06 17:15:13 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.5 2020/05/06 17:19:54 RX: [c13c623f00dd01bb003c2405a5004c25091005a50ca5000000452401] 2020/05/06 17:19:54 (partially decoded) temp 18.7C moisture 47.7% 2020/05/06 17:19:54 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 17:19:54 Message not handled [c13c623f00dd01bb003c2405a5004c25091005a50ca5000000452401] 2020/05/06 17:20:04 RX: [c13c624200dd5f0f103c2405a5004c25091005a50ca5000000462402] 2020/05/06 17:20:04 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 17:20:04 Message not handled [c13c624200dd5f0f103c2405a5004c25091005a50ca5000000462402] 2020/05/06 17:20:37 RX: [c10962040041e800002e240d] 2020/05/06 17:20:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 29 2020/05/06 17:25:36 RX: [c133620300ffff0000362404] 2020/05/06 17:25:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 17:25:50 RX: [c11762030000dd0000482504] 2020/05/06 17:25:50 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 17:26:19 RX: [c13c624200ded11f10482504a5004c25091005a50ca5000000462403] 2020/05/06 17:26:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 17:26:19 Message not handled [c13c624200ded11f10482504a5004c25091005a50ca5000000462403] 2020/05/06 17:26:33 RX: [c13e62030000ff00003c2407] 2020/05/06 17:26:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 17:27:17 RX: [c10c620300011200002e2406] 2020/05/06 17:27:17 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/06 17:28:07 RX: [c10162170000e700de2d2406] 2020/05/06 17:28:07 dropping wheel position on the ground: 22.2 2020/05/06 17:28:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/06 17:28:17 RX: [c13662170000e700b52e240f] 2020/05/06 17:28:17 dropping wheel position on the ground: 18.1 2020/05/06 17:28:17 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/06 17:31:36 RX: [c1356204004224000037240d] 2020/05/06 17:31:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41 2020/05/06 17:32:16 RX: [c13462170000d5000035240e] 2020/05/06 17:32:16 dropping wheel position on the ground: 0.0 2020/05/06 17:32:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 17:32:34 RX: [c13c62420012635c1035240ea5004c25091005a50ca5000000452404] 2020/05/06 17:32:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 17:32:34 Message not handled [c13c62420012635c1035240ea5004c25091005a50ca5000000452404] 2020/05/06 17:34:17 RX: [c13f62030000f700002e2401] 2020/05/06 17:34:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 17:34:17 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 17:36:46 RX: [c10f620300013300003c2501] 2020/05/06 17:36:46 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30.7 2020/05/06 17:37:37 RX: [c13f62030000fd00002d2402] 2020/05/06 17:37:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 17:37:37 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 17:41:13 RX: [c115620300011900004b250b] 2020/05/06 17:41:13 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 17:42:17 RX: [c13f62030000fa00002d2403] 2020/05/06 17:42:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 17:43:37 RX: [c137620400420600002e2403] 2020/05/06 17:43:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.5 2020/05/06 17:43:53 RX: [c13a62170000cd00c13c2402] 2020/05/06 17:43:53 dropping wheel position on the ground: 19.3 2020/05/06 17:43:53 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 17:45:13 RX: [c13b620400421800003c2406] 2020/05/06 17:45:13 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38 2020/05/06 17:48:57 RX: [c10c620300010b00002d2407] 2020/05/06 17:48:57 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/06 17:48:57 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 17:48:57 RX: [c11470000100000000351004] 2020/05/06 17:48:57 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 17:50:04 RX: [c13c62420024ed4c10351004a5002d24071005a50ca5000000462405] 2020/05/06 17:50:04 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 17:50:04 Message not handled [c13c62420024ed4c10351004a5002d24071005a50ca5000000462405] 2020/05/06 17:50:33 RX: [c13e62030000fa00003c2408] 2020/05/06 17:50:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 17:50:37 RX: [c10962040041f266662d240e] 2020/05/06 17:50:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 30.3 2020/05/06 17:55:36 RX: [c133620300ffff0000362405] 2020/05/06 17:55:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 17:55:52 RX: [c11762030000dd0000482506] 2020/05/06 17:55:52 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 17:56:19 RX: [c13c624200fe776d10482506a5002d24071005a50ca5000000452406] 2020/05/06 17:56:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 17:56:19 Message not handled [c13c624200fe776d10482506a5002d24071005a50ca5000000452406] 2020/05/06 17:57:13 RX: [c13e62030000fa00003d2409] 2020/05/06 17:57:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 17:57:17 RX: [c10c620300011300002d2408] 2020/05/06 17:57:17 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.5 2020/05/06 17:57:17 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 17:57:17 RX: [c11470000000000000351006] 2020/05/06 17:57:17 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 17:58:07 RX: [c10162170000ea00de2d2407] 2020/05/06 17:58:07 dropping wheel position on the ground: 22.2 2020/05/06 17:58:07 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/06 17:58:17 RX: [c13662170000e500b52d2400] 2020/05/06 17:58:17 dropping wheel position on the ground: 18.1 2020/05/06 17:58:17 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/06 17:58:57 RX: [c10c620300011400002e2409] 2020/05/06 17:58:57 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 18:00:00 RX: [c1007339005fcb66004a04201a000000441006] 2020/05/06 18:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/06 18:01:36 RX: [c135620400422b333336240e] 2020/05/06 18:01:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.8 2020/05/06 18:02:16 RX: [c13462170000d5000037240f] 2020/05/06 18:02:16 dropping wheel position on the ground: 0.0 2020/05/06 18:02:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 18:02:35 RX: [c13c62420012f97d1037240fa5000000441006a50ca5000000462407] 2020/05/06 18:02:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:02:35 Message not handled [c13c62420012f97d1037240fa5000000441006a50ca5000000462407] 2020/05/06 18:06:48 RX: [c10f620300013300003c2503] 2020/05/06 18:06:48 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30.7 2020/05/06 18:09:56 RX: [c13c623f00e201bb003c2503a5000000441006a50ca5000000472408] 2020/05/06 18:09:56 (partially decoded) temp 18.7C moisture 48.2% 2020/05/06 18:09:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT OUT 2020/05/06 18:09:56 Message not handled [c13c623f00e201bb003c2503a5000000441006a50ca5000000472408] 2020/05/06 18:10:00 RX: [c1007339005fcb66004a04101a000000441007] 2020/05/06 18:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 18:10:06 RX: [c13c6242001095ea104a04101a000000441007a50ca5000000462409] 2020/05/06 18:10:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 18:10:06 Message not handled [c13c6242001095ea104a04101a000000441007a50ca5000000462409] 2020/05/06 18:11:15 RX: [c115620300011100004b250d] 2020/05/06 18:11:15 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 18:12:17 RX: [c13f62030000f700002d2404] 2020/05/06 18:12:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 18:12:17 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 18:13:37 RX: [c137620400420c66662d2404] 2020/05/06 18:13:37 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.1 2020/05/06 18:13:53 RX: [c13a62170000cf00c13c2403] 2020/05/06 18:13:53 dropping wheel position on the ground: 19.3 2020/05/06 18:13:53 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 18:15:13 RX: [c13b620400421c66663c2407] 2020/05/06 18:15:13 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.1 2020/05/06 18:16:21 RX: [c13c624200120fcb103c2407a5000000441007a50ca500000046240a] 2020/05/06 18:16:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:16:21 Message not handled [c13c624200120fcb103c2407a5000000441007a50ca500000046240a] 2020/05/06 18:20:37 RX: [c10962040041f4cccd2d240f] 2020/05/06 18:20:37 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 30.6 2020/05/06 18:22:36 RX: [c13c6242001281db102d240fa5000000441007a50ca500000045240b] 2020/05/06 18:22:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:22:36 Message not handled [c13c6242001281db102d240fa5000000441007a50ca500000045240b] 2020/05/06 18:24:50 RX: [c10f620300012c00003b2505] 2020/05/06 18:24:50 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30 2020/05/06 18:25:36 RX: [c133620300ffff0000372406] 2020/05/06 18:25:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 18:25:54 RX: [c11762030000dd0000472508] 2020/05/06 18:25:54 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 18:27:13 RX: [c13e62030000fa00003e240a] 2020/05/06 18:27:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 18:28:06 RX: [c10162170000ed00de2d2408] 2020/05/06 18:28:06 dropping wheel position on the ground: 22.2 2020/05/06 18:28:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 18:28:16 RX: [c13662170000e200b52d2401] 2020/05/06 18:28:16 dropping wheel position on the ground: 18.1 2020/05/06 18:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.6 2020/05/06 18:28:56 RX: [c10c620300011100002d240a] 2020/05/06 18:28:56 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/06 18:31:36 RX: [c1356204004234cccd37240f] 2020/05/06 18:31:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 45.2 2020/05/06 18:31:56 RX: [c13c623f00e201bc0037240fa5000000441007a50ca500000046240c] 2020/05/06 18:31:56 (partially decoded) temp 18.8C moisture 48.2% 2020/05/06 18:31:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 18:31:56 Message not handled [c13c623f00e201bc0037240fa5000000441007a50ca500000046240c] 2020/05/06 18:32:16 RX: [c13462170000d50000352400] 2020/05/06 18:32:16 dropping wheel position on the ground: 0.0 2020/05/06 18:32:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 18:37:36 RX: [c13f62030000fc00002e2405] 2020/05/06 18:37:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 18:38:36 RX: [c13c623f00df01bc002e2405a5000000441007a50ca500000046240d] 2020/05/06 18:38:36 (partially decoded) temp 18.8C moisture 47.9% 2020/05/06 18:38:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 18:38:36 Message not handled [c13c623f00df01bc002e2405a5000000441007a50ca500000046240d] 2020/05/06 18:40:06 RX: [c13c624200df27a9102e2405a5000000441007a50ca500000045240e] 2020/05/06 18:40:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:40:06 Message not handled [c13c624200df27a9102e2405a5000000441007a50ca500000045240e] 2020/05/06 18:41:17 RX: [c115620300010e00004b250f] 2020/05/06 18:41:17 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 18:41:17 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 18:41:18 RX: [c11070000100000000491007] 2020/05/06 18:41:18 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 18:41:36 RX: [c13f62030000f600002d2406] 2020/05/06 18:41:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 18:43:36 RX: [c137620400420e00002d2405] 2020/05/06 18:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.5 2020/05/06 18:43:37 RX: [c13f62030000f800002d2407] 2020/05/06 18:43:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 18:43:53 RX: [c13a62170000d000c13d2404] 2020/05/06 18:43:53 dropping wheel position on the ground: 19.3 2020/05/06 18:43:53 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 18:45:13 RX: [c13b620400421ecccd3c2408] 2020/05/06 18:45:13 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.7 2020/05/06 18:46:21 RX: [c13c62420012a9b9103c2408a5004b250f1007a50ca500000044240f] 2020/05/06 18:46:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:46:21 Message not handled [c13c62420012a9b9103c2408a5004b250f1007a50ca500000044240f] 2020/05/06 18:48:56 RX: [c13f62030000fd00002d2408] 2020/05/06 18:48:56 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 18:48:57 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 18:50:33 RX: [c13e62030000f500003d240b] 2020/05/06 18:50:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 18:50:33 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 18:50:36 RX: [c10962040041fa66662d2400] 2020/05/06 18:50:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31.3 2020/05/06 18:52:37 RX: [c13c624200124b3e102d2400a5004b250f1007a50ca5000000452400] 2020/05/06 18:52:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 18:52:37 Message not handled [c13c624200124b3e102d2400a5004b250f1007a50ca5000000452400] 2020/05/06 18:53:53 RX: [c13e62030000fa00003d240c] 2020/05/06 18:53:53 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 18:54:34 RX: [c10f620300012500003b2507] 2020/05/06 18:54:34 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 18:55:36 RX: [c133620300ffff0000372407] 2020/05/06 18:55:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 18:55:36 RX: [c10c620300010a00002d240b] 2020/05/06 18:55:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.6 2020/05/06 18:55:36 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/06 18:55:37 RX: [c11470000100000000361008] 2020/05/06 18:55:37 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 18:55:56 RX: [c11762030000dd000047250a] 2020/05/06 18:55:56 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 18:58:06 RX: [c10162170000ee00de2d2409] 2020/05/06 18:58:06 dropping wheel position on the ground: 22.2 2020/05/06 18:58:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 18:58:16 RX: [c13662170000e200b52d2402] 2020/05/06 18:58:16 dropping wheel position on the ground: 18.1 2020/05/06 18:58:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.6 2020/05/06 18:58:33 RX: [c13e62030000fc00003d240d] 2020/05/06 18:58:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 18:59:46 RX: [c10c620300010f00002d240c] 2020/05/06 18:59:46 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/06 18:59:57 RX: [c13c623f00de01bc002d240ca5002d240b1007a50ca5000000452401] 2020/05/06 18:59:57 (partially decoded) temp 18.8C moisture 47.8% 2020/05/06 18:59:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 18:59:57 Message not handled [c13c623f00de01bc002d240ca5002d240b1007a50ca5000000452401] 2020/05/06 19:00:00 RX: [c1007339005fcb66004a04201a000000451008] 2020/05/06 19:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/06 19:00:07 RX: [c13c624200205f0f104a04201a000000451008a50ca5000000452402] 2020/05/06 19:00:07 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 19:00:07 Message not handled [c13c624200205f0f104a04201a000000451008a50ca5000000452402] 2020/05/06 19:01:36 RX: [c135620400423b999a372400] 2020/05/06 19:01:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 46.9 2020/05/06 19:02:16 RX: [c13462170000d50000372401] 2020/05/06 19:02:16 dropping wheel position on the ground: 0.0 2020/05/06 19:02:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 19:03:13 RX: [c13e620300010100003d240e] 2020/05/06 19:03:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 19:03:13 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 19:04:39 RX: [c115620300011900004b2501] 2020/05/06 19:04:39 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 19:04:39 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 19:04:39 RX: [c11070000000000000481009] 2020/05/06 19:04:39 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 19:05:36 RX: [c10c620300011700002d240d] 2020/05/06 19:05:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 19:05:36 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/06 19:05:37 RX: [c1147000000000000036100a] 2020/05/06 19:05:37 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 19:06:23 RX: [c13c62420026d11f1036100aa5002d240d1008a50ca5000000462403] 2020/05/06 19:06:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 19:06:23 Message not handled [c13c62420026d11f1036100aa5002d240d1008a50ca5000000462403] 2020/05/06 19:09:13 RX: [c13e62030000fc00003d240f] 2020/05/06 19:09:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 19:10:00 RX: [c1007339005fcb66004a04101a000000441009] 2020/05/06 19:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 19:11:19 MQTT message; topic: 'xcomfort/26/set/dimmer', message: '100' 2020/05/06 19:11:21 RX: [c100733900b3f868004d0002ff001d00000050100c] 2020/05/06 19:11:21 Device 6879411, type CDAU 01/04 sent extended status message: value 255, temp 29C (battery mains-powered, signal weak) 2020/05/06 19:12:33 RX: [c13e620300010200003c2400] 2020/05/06 19:12:33 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.8 2020/05/06 19:12:38 RX: [c13c62420012635c103c2400a5001d00000050100ca5000000452404] 2020/05/06 19:12:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 19:12:38 Message not handled [c13c62420012635c103c2400a5001d00000050100ca5000000452404] 2020/05/06 19:13:36 RX: [c137620400420e66662d2406] 2020/05/06 19:13:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.6 2020/05/06 19:13:53 RX: [c13a62170000d000c13d2405] 2020/05/06 19:13:53 dropping wheel position on the ground: 19.3 2020/05/06 19:13:53 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 19:14:16 RX: [c13f62030000fc00002d2409] 2020/05/06 19:14:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 19:15:13 RX: [c13b6204004220cccd3c2409] 2020/05/06 19:15:13 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.2 2020/05/06 19:17:13 RX: [c13e62030000fd00003d2401] 2020/05/06 19:17:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 19:20:36 RX: [c10962040041f800002d2401] 2020/05/06 19:20:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31 2020/05/06 19:20:38 RX: [c13c623f00d801bb002d2401a5001d00000050100ca5000000462405] 2020/05/06 19:20:38 (partially decoded) temp 18.7C moisture 47.2% 2020/05/06 19:20:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 19:20:38 Message not handled [c13c623f00d801bb002d2401a5001d00000050100ca5000000462405] 2020/05/06 19:24:36 RX: [c10f620300012500003b2509] 2020/05/06 19:24:36 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 19:25:36 RX: [c133620300ffff0000352408] 2020/05/06 19:25:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 19:25:58 RX: [c11762030000dd000046250c] 2020/05/06 19:25:58 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 19:28:06 RX: [c10162170000ef00de2d240a] 2020/05/06 19:28:06 dropping wheel position on the ground: 22.2 2020/05/06 19:28:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/06 19:28:16 RX: [c13662170000df00b52d2403] 2020/05/06 19:28:16 dropping wheel position on the ground: 18.1 2020/05/06 19:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.3 2020/05/06 19:29:18 RX: [c13c623f00d901bb002d2403a5001d00000050100ca5000000462406] 2020/05/06 19:29:18 (partially decoded) temp 18.7C moisture 47.3% 2020/05/06 19:29:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 19:29:18 Message not handled [c13c623f00d901bb002d2403a5001d00000050100ca5000000462406] 2020/05/06 19:30:08 RX: [c13c624200d9f97d102d2403a5001d00000050100ca5000000452407] 2020/05/06 19:30:08 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 19:30:08 Message not handled [c13c624200d9f97d102d2403a5001d00000050100ca5000000452407] 2020/05/06 19:30:36 RX: [c10c620300011400002d240e] 2020/05/06 19:30:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/06 19:31:13 RX: [c13e62030000ff00003d2402] 2020/05/06 19:31:13 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 19:31:36 RX: [c13562040042413333362401] 2020/05/06 19:31:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 48.3 2020/05/06 19:32:16 RX: [c13462170000d50000372402] 2020/05/06 19:32:16 dropping wheel position on the ground: 0.0 2020/05/06 19:32:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 19:34:41 RX: [c115620300011500004b2503] 2020/05/06 19:34:41 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.7 2020/05/06 19:36:23 RX: [c13c624200c01bfa104b2503a5001d00000050100ca5000000462408] 2020/05/06 19:36:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 19:36:23 Message not handled [c13c624200c01bfa104b2503a5001d00000050100ca5000000462408] 2020/05/06 19:42:39 RX: [c13c6242001295ea104b2503a5001d00000050100ca5000000452409] 2020/05/06 19:42:39 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 19:42:39 Message not handled [c13c6242001295ea104b2503a5001d00000050100ca5000000452409] 2020/05/06 19:43:36 RX: [c137620400420f999a2d2407] 2020/05/06 19:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.9 2020/05/06 19:43:52 RX: [c13a62170000d000c13d2406] 2020/05/06 19:43:52 dropping wheel position on the ground: 19.3 2020/05/06 19:43:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/06 19:44:16 RX: [c13f62030000fc00002d240a] 2020/05/06 19:44:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 19:45:12 RX: [c13b620400422200003d240a] 2020/05/06 19:45:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.5 2020/05/06 19:49:59 RX: [c13c623f00d501bb003d240aa5001d00000050100ca500000046240a] 2020/05/06 19:49:59 (partially decoded) temp 18.7C moisture 46.9% 2020/05/06 19:49:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 19:49:59 Message not handled [c13c623f00d501bb003d240aa5001d00000050100ca500000046240a] 2020/05/06 19:50:09 RX: [c13c624200d581db103d240aa5001d00000050100ca500000046240b] 2020/05/06 19:50:09 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 19:50:09 Message not handled [c13c624200d581db103d240aa5001d00000050100ca500000046240b] 2020/05/06 19:50:36 RX: [c10962040041fa66662d2402] 2020/05/06 19:50:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 31.3 2020/05/06 19:54:38 RX: [c10f620300012200003a250b] 2020/05/06 19:54:38 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 19:55:36 RX: [c133620300ffff0000382409] 2020/05/06 19:55:36 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 19:56:00 RX: [c11762030000dd000047250e] 2020/05/06 19:56:00 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 19:56:24 RX: [c13c6242007e33981047250ea5001d00000050100ca500000047240c] 2020/05/06 19:56:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 19:56:24 Message not handled [c13c6242007e33981047250ea5001d00000050100ca500000047240c] 2020/05/06 19:58:06 RX: [c10162170000ee00de2d240b] 2020/05/06 19:58:06 dropping wheel position on the ground: 22.2 2020/05/06 19:58:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 19:58:16 RX: [c13662170000dd00b52d2404] 2020/05/06 19:58:16 dropping wheel position on the ground: 18.1 2020/05/06 19:58:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.1 2020/05/06 20:00:00 RX: [c1007339005fcb66004a04201a00000045100a] 2020/05/06 20:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/06 20:00:36 RX: [c10c620300010f00002d240f] 2020/05/06 20:00:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/06 20:01:12 RX: [c13e62030000fd00003d2403] 2020/05/06 20:01:12 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 20:01:36 RX: [c1356204004245999a372402] 2020/05/06 20:01:36 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 49.4 2020/05/06 20:02:16 RX: [c13462170000d60000372403] 2020/05/06 20:02:16 dropping wheel position on the ground: 0.0 2020/05/06 20:02:16 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.4 2020/05/06 20:02:40 RX: [c13c62420012bd8810372403a500000045100aa50ca500000046240d] 2020/05/06 20:02:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:02:40 Message not handled [c13c62420012bd8810372403a500000045100aa50ca500000046240d] 2020/05/06 20:04:43 RX: [c115620300011100004c2505] 2020/05/06 20:04:43 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27.3 2020/05/06 20:08:56 RX: [c13f62030000f500002d240b] 2020/05/06 20:08:56 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 20:08:56 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/06 20:10:00 RX: [c13c623f00d001bb002d240ba500000045100aa50ca500000045240e] 2020/05/06 20:10:00 (partially decoded) temp 18.7C moisture 46.4% 2020/05/06 20:10:00 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 20:10:00 Message not handled [c13c623f00d001bb002d240ba500000045100aa50ca500000045240e] 2020/05/06 20:10:00 RX: [c1007339005fcb66004a04101a00000045100b] 2020/05/06 20:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 20:12:16 RX: [c13f62030000fa00002d240c] 2020/05/06 20:12:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 20:13:36 RX: [c137620400421133332d2408] 2020/05/06 20:13:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.3 2020/05/06 20:13:52 RX: [c13a62170000cf00c13e2407] 2020/05/06 20:13:52 dropping wheel position on the ground: 19.3 2020/05/06 20:13:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 20:15:12 RX: [c13b620400422266663d240b] 2020/05/06 20:15:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.6 2020/05/06 20:15:36 RX: [c13f62030000f900002d240d] 2020/05/06 20:15:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 20:17:20 RX: [c13c623f00d201bb002d240da500000045100ba50ca500000046240f] 2020/05/06 20:17:20 (partially decoded) temp 18.7C moisture 46.6% 2020/05/06 20:17:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 20:17:20 Message not handled [c13c623f00d201bb002d240da500000045100ba50ca500000046240f] 2020/05/06 20:20:10 RX: [c13c624200974b3e102d240da500000045100ba50ca5000000452400] 2020/05/06 20:20:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:20:10 Message not handled [c13c624200974b3e102d240da500000045100ba50ca5000000452400] 2020/05/06 20:20:36 RX: [c109620400420066662e2403] 2020/05/06 20:20:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.1 2020/05/06 20:24:41 RX: [c10f620300012200003a250d] 2020/05/06 20:24:41 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 20:25:35 RX: [c133620300ffff000035240a] 2020/05/06 20:25:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 20:26:02 RX: [c11762030000dd0000462500] 2020/05/06 20:26:02 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 20:26:25 RX: [c13c6242009ec52e10462500a500000045100ba50ca5000000462401] 2020/05/06 20:26:25 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 20:26:25 Message not handled [c13c6242009ec52e10462500a500000045100ba50ca5000000462401] 2020/05/06 20:27:12 RX: [c13e62030000f700003d2404] 2020/05/06 20:27:12 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 20:27:12 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/06 20:28:06 RX: [c10162170000ee00de2d240c] 2020/05/06 20:28:06 dropping wheel position on the ground: 22.2 2020/05/06 20:28:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 20:28:16 RX: [c13662170000dc00b52d2405] 2020/05/06 20:28:16 dropping wheel position on the ground: 18.1 2020/05/06 20:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22 2020/05/06 20:30:36 RX: [c10c620300010c00002d2400] 2020/05/06 20:30:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.8 2020/05/06 20:31:35 RX: [c13562040042473333362403] 2020/05/06 20:31:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 49.8 2020/05/06 20:31:52 RX: [c13e62030000fb00003d2405] 2020/05/06 20:31:52 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 20:32:15 RX: [c13462170000d60000372404] 2020/05/06 20:32:15 dropping wheel position on the ground: 0.0 2020/05/06 20:32:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.4 2020/05/06 20:32:41 RX: [c13c624200125f0f10372404a500000045100ba50ca5000000462402] 2020/05/06 20:32:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:32:41 Message not handled [c13c624200125f0f10372404a500000045100ba50ca5000000462402] 2020/05/06 20:34:45 RX: [c115620300010e00004c2507] 2020/05/06 20:34:45 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27 2020/05/06 20:34:45 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/06 20:34:45 RX: [c1107000010000000049100b] 2020/05/06 20:34:45 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 20:34:53 RX: [c10f620300011b00003a250e] 2020/05/06 20:34:53 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 20:34:53 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 20:34:54 RX: [c11870000100000000451009] 2020/05/06 20:34:54 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/06 20:39:05 RX: [c10f620300012500003a250f] 2020/05/06 20:39:05 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 20:39:05 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 20:39:06 RX: [c1187000000000000043100b] 2020/05/06 20:39:06 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 20:39:12 RX: [c13e620300010000003d2406] 2020/05/06 20:39:12 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 20:39:12 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/06 20:40:01 RX: [c13c623f00cb01bb003d2406a5003a250f100ba50ca5000000462403] 2020/05/06 20:40:01 (partially decoded) temp 18.7C moisture 45.9% 2020/05/06 20:40:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 20:40:01 Message not handled [c13c623f00cb01bb003d2406a5003a250f100ba50ca5000000462403] 2020/05/06 20:40:11 RX: [c13c624200cb635c103d2406a5003a250f100ba50ca5000000472404] 2020/05/06 20:40:11 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:40:11 Message not handled [c13c624200cb635c103d2406a5003a250f100ba50ca5000000472404] 2020/05/06 20:43:36 RX: [c1376204004212cccd2d2409] 2020/05/06 20:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.7 2020/05/06 20:43:52 RX: [c13a62170000cf00c13d2408] 2020/05/06 20:43:52 dropping wheel position on the ground: 19.3 2020/05/06 20:43:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 20:45:12 RX: [c13b620400422400003d240c] 2020/05/06 20:45:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41 2020/05/06 20:45:36 RX: [c13f62030000fb00002d240e] 2020/05/06 20:45:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 20:46:26 RX: [c13c62420012ed4c102d240ea5003a250f100ba50ca5000000452405] 2020/05/06 20:46:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:46:26 Message not handled [c13c62420012ed4c102d240ea5003a250f100ba50ca5000000452405] 2020/05/06 20:50:36 RX: [c1096204004202cccd2d2404] 2020/05/06 20:50:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 32.7 2020/05/06 20:52:42 RX: [c13c62420012776d102d2404a5003a250f100ba50ca5000000452406] 2020/05/06 20:52:42 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 20:52:42 Message not handled [c13c62420012776d102d2404a5003a250f100ba50ca5000000452406] 2020/05/06 20:55:35 RX: [c133620300ffff000036240b] 2020/05/06 20:55:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 20:56:03 RX: [c11762030000dd0000482502] 2020/05/06 20:56:03 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 20:56:31 RX: [c10f620300011e00003c2501] 2020/05/06 20:56:31 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 20:56:31 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/06 20:56:32 RX: [c1187000010000000041100d] 2020/05/06 20:56:32 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/06 20:56:49 RX: [c10b7000000000000044100f] 2020/05/06 20:56:49 Device 5734068 (channel 0-'1.etg liten gang') sent message (battery mains-powered, signal normal, cyclic false) value 0 2020/05/06 20:56:50 RX: [c107700000000000004d1002] 2020/05/06 20:56:50 Device 5736925 (channel 0-'1.etg bad tak') sent message (battery mains-powered, signal weak, cyclic false) value 0 2020/05/06 20:56:50 RX: [c113700000000000002e1009] 2020/05/06 20:56:50 Device 5734274 (channel 0-'1.etg kj�kken spotter') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 20:56:50 RX: [c108700000000000003d1008] 2020/05/06 20:56:50 Device 5734000 (channel 0-'1.etg stor gang') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 20:56:51 RX: [c10d70000000000000431002] 2020/05/06 20:56:51 Device 5741956 (channel 0-'1.etg stue lampe spi') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 20:56:51 RX: [c11970006200000000371009] 2020/05/06 20:56:51 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/06 20:57:00 RX: [c100733900d80269004d000100002c000000361004] 2020/05/06 20:57:00 Device 6882008, type CDAU 01/04 sent extended status message: value 0, temp 44C (battery mains-powered, signal good) 2020/05/06 20:57:01 RX: [c100733900b4fa68004d000100002a000000441005] 2020/05/06 20:57:01 Device 6879924, type CDAU 01/04 sent extended status message: value 0, temp 42C (battery mains-powered, signal normal) 2020/05/06 20:57:02 RX: [c100733900070569004d0001000027000000401001] 2020/05/06 20:57:02 Device 6882567, type CDAU 01/04 sent extended status message: value 0, temp 39C (battery mains-powered, signal good) 2020/05/06 20:57:03 RX: [c1007339006c0469004d00010000260000003d1005] 2020/05/06 20:57:03 Device 6882412, type CDAU 01/04 sent extended status message: value 0, temp 38C (battery mains-powered, signal good) 2020/05/06 20:57:04 RX: [c1007339004b0369004d00010000280000003b100b] 2020/05/06 20:57:04 Device 6882123, type CDAU 01/04 sent extended status message: value 0, temp 40C (battery mains-powered, signal good) 2020/05/06 20:57:05 RX: [c100733900ec0469004d00010000260000003e100d] 2020/05/06 20:57:05 Device 6882540, type CDAU 01/04 sent extended status message: value 0, temp 38C (battery mains-powered, signal good) 2020/05/06 20:57:06 RX: [c100733900520369004d0001000026000000481000] 2020/05/06 20:57:06 Device 6882130, type CDAU 01/04 sent extended status message: value 0, temp 38C (battery mains-powered, signal normal) 2020/05/06 20:57:07 RX: [c1007339008e0269004d00010000250000002d1003] 2020/05/06 20:57:07 Device 6881934, type CDAU 01/04 sent extended status message: value 0, temp 37C (battery mains-powered, signal good) 2020/05/06 20:58:06 MQTT message; topic: 'xcomfort/2/set/switch', message: 'false' 2020/05/06 20:58:06 RX: [c10162170000ee00de2d240d] 2020/05/06 20:58:06 dropping wheel position on the ground: 22.2 2020/05/06 20:58:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 20:58:06 RX: [c102700000000000004f1006] 2020/05/06 20:58:06 Device 5740117 (channel 0-'1.etg sov 4') sent message (battery mains-powered, signal weak, cyclic false) value 0 2020/05/06 20:58:16 RX: [c13662170000dd00b52d2406] 2020/05/06 20:58:16 dropping wheel position on the ground: 18.1 2020/05/06 20:58:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.1 2020/05/06 21:00:00 RX: [c1007339005fcb66004a04201a00000043100c] 2020/05/06 21:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal good) 2020/05/06 21:00:02 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/06 21:00:02 RX: [c1187000000000000043100f] 2020/05/06 21:00:02 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 21:00:02 RX: [c13c623f00c601ba0043100fa5004a0420100ca503a5000000452407] 2020/05/06 21:00:02 (partially decoded) temp 18.6C moisture 45.4% 2020/05/06 21:00:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/06 21:00:02 Message not handled [c13c623f00c601ba0043100fa5004a0420100ca503a5000000452407] 2020/05/06 21:00:06 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/06 21:00:06 RX: [c1107000000000000049100d] 2020/05/06 21:00:06 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/06 21:00:12 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/06 21:00:36 RX: [c10c620300010a00002d2401] 2020/05/06 21:00:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.6 2020/05/06 21:01:35 RX: [c13562040042480000352404] 2020/05/06 21:01:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50 2020/05/06 21:02:15 RX: [c13462170000d50000362405] 2020/05/06 21:02:15 dropping wheel position on the ground: 0.0 2020/05/06 21:02:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.3 2020/05/06 21:02:32 RX: [c10f620300012500003b2502] 2020/05/06 21:02:32 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/06 21:02:32 RX: [c13e620300010100003e2407] 2020/05/06 21:02:32 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 21:04:22 RX: [c11562030001190000492509] 2020/05/06 21:04:22 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/06 21:05:22 RX: [c13c623f00c301bb00492509a50043100f100ca503a5000000462408] 2020/05/06 21:05:22 (partially decoded) temp 18.7C moisture 45.1% 2020/05/06 21:05:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT OUT 2020/05/06 21:05:22 Message not handled [c13c623f00c301bb00492509a50043100f100ca503a5000000462408] 2020/05/06 21:07:23 RX: [c1197000000000000039100b] 2020/05/06 21:07:23 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 0 2020/05/06 21:10:00 RX: [c1007339005fcb66004a04101a00000044100d] 2020/05/06 21:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 21:10:11 RX: [c13c6242001095ea104a04101a00000044100da503a5000000452409] 2020/05/06 21:10:11 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 21:10:11 Message not handled [c13c6242001095ea104a04101a00000044100da503a5000000452409] 2020/05/06 21:10:25 RX: [c10670000000000000561004] 2020/05/06 21:10:25 Device 5736891 (channel 0-'1.etg bad speil') sent message (battery mains-powered, signal weak, cyclic false) value 0 2020/05/06 21:10:56 RX: [c13f620300010000002d240f] 2020/05/06 21:10:56 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 21:13:36 RX: [c1376204004212cccd2d240a] 2020/05/06 21:13:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.7 2020/05/06 21:13:52 RX: [c13a62170000cf00c13d2409] 2020/05/06 21:13:52 dropping wheel position on the ground: 19.3 2020/05/06 21:13:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/06 21:15:12 RX: [c13b620400422333333d240d] 2020/05/06 21:15:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.8 2020/05/06 21:16:16 RX: [c13f620300010100002d2400] 2020/05/06 21:16:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/06 21:16:27 RX: [c13c624200120fcb102d2400a5004a0410100da503a500000044240a] 2020/05/06 21:16:27 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 21:16:27 Message not handled [c13c624200120fcb102d2400a5004a0410100da503a500000044240a] 2020/05/06 21:20:36 RX: [c109620400420533332d2405] 2020/05/06 21:20:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.3 2020/05/06 21:22:32 MQTT message; topic: 'xcomfort/17/set/switch', message: 'false' 2020/05/06 21:22:32 RX: [c111700000000000003b1008] 2020/05/06 21:22:32 Device 5727252 (channel 0-'utelys hovedd�r') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/06 21:22:43 RX: [c13c6242001681db103b1008a5002d2405100da503a500000044240b] 2020/05/06 21:22:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/06 21:22:43 Message not handled [c13c6242001681db103b1008a5002d2405100da503a500000044240b] 2020/05/06 21:24:32 RX: [c13e62030000fc00003e2408] 2020/05/06 21:24:32 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 21:25:35 RX: [c133620300ffff000036240c] 2020/05/06 21:25:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 21:26:05 RX: [c11762030000dd0000472504] 2020/05/06 21:26:05 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 21:28:06 RX: [c10162170000ee00de2d240e] 2020/05/06 21:28:06 dropping wheel position on the ground: 22.2 2020/05/06 21:28:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.8 2020/05/06 21:28:16 RX: [c13662170000db00b52d2407] 2020/05/06 21:28:16 dropping wheel position on the ground: 18.1 2020/05/06 21:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.9 2020/05/06 21:30:03 RX: [c13c623f00c101bb002d2407a5002d2405100da503a500000044240c] 2020/05/06 21:30:03 (partially decoded) temp 18.7C moisture 44.9% 2020/05/06 21:30:03 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 21:30:03 Message not handled [c13c623f00c101bb002d2407a5002d2405100da503a500000044240c] 2020/05/06 21:30:13 RX: [c13c624200c1bd88102d2407a5002d2405100da503a500000045240d] 2020/05/06 21:30:13 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 21:30:13 Message not handled [c13c624200c1bd88102d2407a5002d2405100da503a500000045240d] 2020/05/06 21:30:36 RX: [c10c620300010600002d2402] 2020/05/06 21:30:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.2 2020/05/06 21:31:35 RX: [c13562040042486666352405] 2020/05/06 21:31:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.1 2020/05/06 21:32:15 RX: [c13462170000d40000362406] 2020/05/06 21:32:15 dropping wheel position on the ground: 0.0 2020/05/06 21:32:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 21:32:34 RX: [c10f620300012200003b2504] 2020/05/06 21:32:34 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 21:33:12 RX: [c13e62030000ff00003d2409] 2020/05/06 21:33:12 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/06 21:34:23 RX: [c115620300011100004a250b] 2020/05/06 21:34:23 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 21:36:28 RX: [c13c6242002727a9104a250ba5002d2405100da503a500000045240e] 2020/05/06 21:36:28 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 21:36:28 Message not handled [c13c6242002727a9104a250ba5002d2405100da503a500000045240e] 2020/05/06 21:42:44 RX: [c13c624200e2a9b9104a250ba5002d2405100da503a500000045240f] 2020/05/06 21:42:44 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 21:42:44 Message not handled [c13c624200e2a9b9104a250ba5002d2405100da503a500000045240f] 2020/05/06 21:43:36 RX: [c137620400421466662d240b] 2020/05/06 21:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.1 2020/05/06 21:43:52 RX: [c13a62170000cd00c13e240a] 2020/05/06 21:43:52 dropping wheel position on the ground: 19.3 2020/05/06 21:43:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/06 21:45:12 RX: [c13b6204004224cccd3d240e] 2020/05/06 21:45:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.2 2020/05/06 21:46:16 RX: [c13f62030000fd00002d2401] 2020/05/06 21:46:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/06 21:49:52 RX: [c13e62030000fa00003d240a] 2020/05/06 21:49:52 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 21:50:36 RX: [c1096204004207999a2d2406] 2020/05/06 21:50:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 33.9 2020/05/06 21:52:44 RX: [c13c623f00bf01ba002d2406a5002d2405100da503a5000000462400] 2020/05/06 21:52:44 (partially decoded) temp 18.6C moisture 44.7% 2020/05/06 21:52:44 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 21:52:44 Message not handled [c13c623f00bf01ba002d2406a5002d2405100da503a5000000462400] 2020/05/06 21:55:35 RX: [c133620300ffff000036240d] 2020/05/06 21:55:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 21:56:07 RX: [c11762030000dd0000492506] 2020/05/06 21:56:07 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 21:58:06 RX: [c10162170000ed00de2d240f] 2020/05/06 21:58:06 dropping wheel position on the ground: 22.2 2020/05/06 21:58:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 21:58:16 RX: [c13662170000d900b52d2408] 2020/05/06 21:58:16 dropping wheel position on the ground: 18.1 2020/05/06 21:58:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.7 2020/05/06 22:00:00 RX: [c1007339005fcb66004a04201a00000044100e] 2020/05/06 22:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/06 22:00:13 RX: [c13c62420020c52e104a04201a00000044100ea503a5000000452401] 2020/05/06 22:00:13 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 22:00:13 Message not handled [c13c62420020c52e104a04201a00000044100ea503a5000000452401] 2020/05/06 22:00:36 RX: [c10c620300010300002d2403] 2020/05/06 22:00:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.9 2020/05/06 22:01:35 RX: [c1356204004249999a362406] 2020/05/06 22:01:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.4 2020/05/06 22:02:15 RX: [c13462170000d30000352407] 2020/05/06 22:02:15 dropping wheel position on the ground: 0.0 2020/05/06 22:02:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 22:02:36 RX: [c10f620300011e00003b2506] 2020/05/06 22:02:36 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 22:03:52 RX: [c13e62030000fb00003d240b] 2020/05/06 22:03:52 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 22:04:25 RX: [c115620300011100004a250d] 2020/05/06 22:04:25 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/06 22:06:29 RX: [c13c624200475f0f104a250da500000044100ea503a5000000462402] 2020/05/06 22:06:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 22:06:29 Message not handled [c13c624200475f0f104a250da500000044100ea503a5000000462402] 2020/05/06 22:07:36 RX: [c13f62030000f800002d2402] 2020/05/06 22:07:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/06 22:10:01 RX: [c1007339005fcb66004a04101a00000044100f] 2020/05/06 22:10:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/06 22:11:36 RX: [c13f62030000fe00002d2403] 2020/05/06 22:11:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.4 2020/05/06 22:12:45 RX: [c13c62420012d11f102d2403a500000044100fa503a5000000442403] 2020/05/06 22:12:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 22:12:45 Message not handled [c13c62420012d11f102d2403a500000044100fa503a5000000442403] 2020/05/06 22:13:36 RX: [c137620400421600002d240c] 2020/05/06 22:13:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.5 2020/05/06 22:13:52 RX: [c13a62170000cc00c13d240b] 2020/05/06 22:13:52 dropping wheel position on the ground: 19.3 2020/05/06 22:13:52 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.4 2020/05/06 22:15:12 RX: [c13b6204004225999a3d240f] 2020/05/06 22:15:12 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.4 2020/05/06 22:17:36 RX: [c13f62030000fc00002d2404] 2020/05/06 22:17:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 22:20:05 RX: [c13c623f00be01ba002d2404a500000044100fa503a5000000462404] 2020/05/06 22:20:05 (partially decoded) temp 18.6C moisture 44.6% 2020/05/06 22:20:05 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 22:20:05 Message not handled [c13c623f00be01ba002d2404a500000044100fa503a5000000462404] 2020/05/06 22:20:15 RX: [c13c624200beed4c102d2404a500000044100fa503a5000000452405] 2020/05/06 22:20:15 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 22:20:15 Message not handled [c13c624200beed4c102d2404a500000044100fa503a5000000452405] 2020/05/06 22:20:36 RX: [c1096204004209999a2d2407] 2020/05/06 22:20:36 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.4 2020/05/06 22:25:35 RX: [c133620300ffff000036240e] 2020/05/06 22:25:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 22:26:09 RX: [c11762030000dd0000472508] 2020/05/06 22:26:09 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 22:26:30 RX: [c13c6242001e776d10472508a500000044100fa503a5000000452406] 2020/05/06 22:26:30 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 22:26:30 Message not handled [c13c6242001e776d10472508a500000044100fa503a5000000452406] 2020/05/06 22:28:06 RX: [c10162170000ed00de2d2400] 2020/05/06 22:28:06 dropping wheel position on the ground: 22.2 2020/05/06 22:28:06 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/06 22:28:16 RX: [c13662170000d600b52d2409] 2020/05/06 22:28:16 dropping wheel position on the ground: 18.1 2020/05/06 22:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.4 2020/05/06 22:30:36 RX: [c10c620300010300002d2404] 2020/05/06 22:30:36 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.9 2020/05/06 22:31:35 RX: [c135620400424a0000342407] 2020/05/06 22:31:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.5 2020/05/06 22:32:15 RX: [c13462170000d30000362408] 2020/05/06 22:32:15 dropping wheel position on the ground: 0.0 2020/05/06 22:32:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.1 2020/05/06 22:32:38 RX: [c10f620300012200003b2508] 2020/05/06 22:32:38 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 22:32:45 RX: [c13c62420012f97d103b2508a500000044100fa503a5000000452407] 2020/05/06 22:32:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 22:32:45 Message not handled [c13c62420012f97d103b2508a500000044100fa503a5000000452407] 2020/05/06 22:33:51 RX: [c13e62030000fc00003d240c] 2020/05/06 22:33:51 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 22:34:27 RX: [c115620300010e00004b250f] 2020/05/06 22:34:27 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27 2020/05/06 22:36:16 RX: [c13f62030000f600002d2405] 2020/05/06 22:36:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 22:38:38 RX: [c10f620300011b00003b2509] 2020/05/06 22:38:38 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 22:39:36 RX: [c13f62030000fb00002d2406] 2020/05/06 22:39:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 22:40:31 RX: [c13e62030000f700003d240d] 2020/05/06 22:40:31 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/06 22:43:36 RX: [c137620400421733332d240d] 2020/05/06 22:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.8 2020/05/06 22:43:37 RX: [c13f62030000f500002d2407] 2020/05/06 22:43:37 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 22:43:51 RX: [c13a62170000cb00c13e240c] 2020/05/06 22:43:51 dropping wheel position on the ground: 19.3 2020/05/06 22:43:51 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/06 22:43:52 RX: [c13e62030000fc00003d240e] 2020/05/06 22:43:52 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.2 2020/05/06 22:45:11 RX: [c13b620400422733333d2400] 2020/05/06 22:45:11 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 41.8 2020/05/06 22:45:34 RX: [c10f620300012200003b250b] 2020/05/06 22:45:34 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/06 22:46:56 RX: [c13f62030000fa00002d2408] 2020/05/06 22:46:56 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/06 22:50:15 RX: [c13c624200f71bfa102d2408a500000044100fa503a5000000462408] 2020/05/06 22:50:15 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 22:50:15 Message not handled [c13c624200f71bfa102d2408a500000044100fa503a5000000462408] 2020/05/06 22:50:16 RX: [c13f62030000f900002d2409] 2020/05/06 22:50:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 22:50:35 RX: [c109620400420b33332d2408] 2020/05/06 22:50:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 34.8 2020/05/06 22:51:11 RX: [c13e62030000f600003d240f] 2020/05/06 22:51:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/06 22:52:28 RX: [c10f620300011b00003b250c] 2020/05/06 22:52:28 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/06 22:55:35 RX: [c133620300ffff000035240f] 2020/05/06 22:55:35 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 22:56:11 RX: [c11762030000dd000047250a] 2020/05/06 22:56:11 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 22:56:30 RX: [c13c6242003e95ea1047250aa500000044100fa503a5000000452409] 2020/05/06 22:56:30 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/06 22:56:30 Message not handled [c13c6242003e95ea1047250aa500000044100fa503a5000000452409] 2020/05/06 22:58:05 RX: [c10162170000ec00de2d2401] 2020/05/06 22:58:05 dropping wheel position on the ground: 22.2 2020/05/06 22:58:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/06 22:58:16 RX: [c13662170000d400b52d240a] 2020/05/06 22:58:16 dropping wheel position on the ground: 18.1 2020/05/06 22:58:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21.2 2020/05/06 22:59:11 RX: [c13e62030000fb00003d2400] 2020/05/06 22:59:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 23:00:00 RX: [c1007339005fcb66004a04201a000000451000] 2020/05/06 23:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/06 23:00:35 RX: [c10c620300010000002d2405] 2020/05/06 23:00:35 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 23:01:35 RX: [c135620400424b3333352408] 2020/05/06 23:01:35 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.8 2020/05/06 23:02:15 RX: [c13462170000d20000352409] 2020/05/06 23:02:15 dropping wheel position on the ground: 0.0 2020/05/06 23:02:15 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 23:02:46 RX: [c13c624200120fcb10352409a5000000451000a503a500000045240a] 2020/05/06 23:02:46 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 23:02:46 Message not handled [c13c624200120fcb10352409a5000000451000a503a500000045240a] 2020/05/06 23:04:29 RX: [c115620300010a00004b2501] 2020/05/06 23:04:29 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.6 2020/05/06 23:06:31 RX: [c13e62030000fb00003d2401] 2020/05/06 23:06:31 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/06 23:10:00 RX: [c1007339005fcb66004a04101a000000431001] 2020/05/06 23:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/06 23:10:07 RX: [c13c623f00bd01b9004a04101a000000431001a503a500000044240b] 2020/05/06 23:10:07 (partially decoded) temp 18.5C moisture 44.5% 2020/05/06 23:10:07 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT OUT 2020/05/06 23:10:07 Message not handled [c13c623f00bd01b9004a04101a000000431001a503a500000044240b] 2020/05/06 23:10:17 RX: [c13c624200bd3398104a04101a000000431001a503a500000046240c] 2020/05/06 23:10:17 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/06 23:10:17 Message not handled [c13c624200bd3398104a04101a000000431001a503a500000046240c] 2020/05/06 23:12:31 RX: [c13e62030000f500003c2402] 2020/05/06 23:12:31 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 23:13:36 RX: [c137620400421866662d240e] 2020/05/06 23:13:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.1 2020/05/06 23:13:51 RX: [c13a62170000c900c13d240d] 2020/05/06 23:13:51 dropping wheel position on the ground: 19.3 2020/05/06 23:13:51 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/06 23:15:11 RX: [c13b620400422800003d2401] 2020/05/06 23:15:11 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42 2020/05/06 23:16:32 RX: [c13c62420012bd88103d2401a5000000431001a503a500000046240d] 2020/05/06 23:16:32 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 23:16:32 Message not handled [c13c62420012bd88103d2401a5000000431001a503a500000046240d] 2020/05/06 23:20:16 RX: [c13f62030000f900002d240a] 2020/05/06 23:20:16 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/06 23:20:35 RX: [c109620400420d33332d2409] 2020/05/06 23:20:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.3 2020/05/06 23:22:30 RX: [c10f620300011e00003b250e] 2020/05/06 23:22:30 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/06 23:22:47 RX: [c13c6242001227a9103b250ea5000000431001a503a500000045240e] 2020/05/06 23:22:47 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/06 23:22:47 Message not handled [c13c6242001227a9103b250ea5000000431001a503a500000045240e] 2020/05/06 23:25:34 RX: [c133620300ffff0000352400] 2020/05/06 23:25:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 23:26:13 RX: [c11762030000dd000047250c] 2020/05/06 23:26:13 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 23:28:05 RX: [c10162170000eb00de2d2402] 2020/05/06 23:28:05 dropping wheel position on the ground: 22.2 2020/05/06 23:28:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.5 2020/05/06 23:28:16 RX: [c13662170000d200b52d240b] 2020/05/06 23:28:16 dropping wheel position on the ground: 18.1 2020/05/06 23:28:16 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 21 2020/05/06 23:28:17 RX: [c13f62030000f400002d240b] 2020/05/06 23:28:17 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 23:30:19 RX: [c10f620300011700003b250f] 2020/05/06 23:30:19 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/06 23:30:35 RX: [c10c620300010000002d2406] 2020/05/06 23:30:35 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/06 23:31:34 RX: [c135620400424b999a372409] 2020/05/06 23:31:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.9 2020/05/06 23:32:14 RX: [c13462170000d1000034240a] 2020/05/06 23:32:14 dropping wheel position on the ground: 0.0 2020/05/06 23:32:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.9 2020/05/06 23:34:31 RX: [c115620300010600004a2503] 2020/05/06 23:34:31 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.2 2020/05/06 23:37:11 RX: [c13e62030000f400003d2403] 2020/05/06 23:37:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/06 23:40:07 RX: [c13c623f00bc01b9003d2403a5000000431001a503a500000045240f] 2020/05/06 23:40:07 (partially decoded) temp 18.5C moisture 44.4% 2020/05/06 23:40:07 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/06 23:40:07 Message not handled [c13c623f00bc01b9003d2403a5000000431001a503a500000045240f] 2020/05/06 23:40:17 RX: [c13c624200bc4b3e103d2403a5000000431001a503a5000000452400] 2020/05/06 23:40:17 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 23:40:17 Message not handled [c13c624200bc4b3e103d2403a5000000431001a503a5000000452400] 2020/05/06 23:43:36 RX: [c1376204004219999a2d240f] 2020/05/06 23:43:36 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.4 2020/05/06 23:43:51 RX: [c13a62170000c800c13d240e] 2020/05/06 23:43:51 dropping wheel position on the ground: 19.3 2020/05/06 23:43:51 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/06 23:45:11 RX: [c13b6204004228cccd3d2402] 2020/05/06 23:45:11 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.2 2020/05/06 23:46:32 RX: [c13c62420012c52e103d2402a5000000431001a503a5000000442401] 2020/05/06 23:46:32 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 23:46:32 Message not handled [c13c62420012c52e103d2402a5000000431001a503a5000000442401] 2020/05/06 23:50:35 RX: [c109620400420f33332d240a] 2020/05/06 23:50:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 35.8 2020/05/06 23:50:56 RX: [c13f62030000f500002d240c] 2020/05/06 23:50:56 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/06 23:52:48 RX: [c13c624200125f0f102d240ca5000000431001a503a5000000462402] 2020/05/06 23:52:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/06 23:52:48 Message not handled [c13c624200125f0f102d240ca5000000431001a503a5000000462402] 2020/05/06 23:55:34 RX: [c133620300ffff0000352401] 2020/05/06 23:55:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/06 23:56:15 RX: [c11762030000dd000047250e] 2020/05/06 23:56:15 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/06 23:58:05 RX: [c10162170000eb00de2d2403] 2020/05/06 23:58:05 dropping wheel position on the ground: 22.2 2020/05/06 23:58:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.5 2020/05/06 23:58:15 RX: [c13662170000d000b52d240c] 2020/05/06 23:58:15 dropping wheel position on the ground: 18.1 2020/05/06 23:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/07 00:00:00 RX: [c1007339005fcb66004a04201a000000451002] 2020/05/07 00:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 00:00:08 RX: [c13c623f00bd01b9004a04201a000000451002a503a5000000452403] 2020/05/07 00:00:08 (partially decoded) temp 18.5C moisture 44.5% 2020/05/07 00:00:08 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT OUT 2020/05/07 00:00:08 Message not handled [c13c623f00bd01b9004a04201a000000451002a503a5000000452403] 2020/05/07 00:00:18 RX: [c13c624200bd635c104a04201a000000451002a503a5000000452404] 2020/05/07 00:00:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 00:00:18 Message not handled [c13c624200bd635c104a04201a000000451002a503a5000000452404] 2020/05/07 00:00:21 RX: [c10f620300011700003a2501] 2020/05/07 00:00:21 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 00:00:35 RX: [c10c62030000f900002d2407] 2020/05/07 00:00:35 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 00:01:25 RX: [c10c62030000fa00002d2408] 2020/05/07 00:01:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 00:01:34 RX: [c135620400424c666635240a] 2020/05/07 00:01:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.1 2020/05/07 00:02:14 RX: [c13462170000d0000036240b] 2020/05/07 00:02:14 dropping wheel position on the ground: 0.0 2020/05/07 00:02:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/07 00:04:33 RX: [c115620300010300004a2505] 2020/05/07 00:04:33 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/07 00:06:34 RX: [c13c62420061ed4c104a2505a5000000451002a503a5000000442405] 2020/05/07 00:06:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 00:06:34 Message not handled [c13c62420061ed4c104a2505a5000000451002a503a5000000442405] 2020/05/07 00:07:11 RX: [c13e62030000f300003d2404] 2020/05/07 00:07:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.3 2020/05/07 00:10:00 RX: [c1007339005fcb66004a04101a000000431003] 2020/05/07 00:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/07 00:12:49 RX: [c13c62420092776d104a04101a000000431003a503a5000000442406] 2020/05/07 00:12:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 00:12:49 Message not handled [c13c62420092776d104a04101a000000431003a503a5000000442406] 2020/05/07 00:13:35 RX: [c137620400421a66662d2400] 2020/05/07 00:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.6 2020/05/07 00:13:36 RX: [c13f62030000f000002d240d] 2020/05/07 00:13:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/07 00:13:51 RX: [c13a62170000c700c13d240f] 2020/05/07 00:13:51 dropping wheel position on the ground: 19.3 2020/05/07 00:13:51 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/07 00:15:11 RX: [c13b620400422933333c2403] 2020/05/07 00:15:11 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.3 2020/05/07 00:20:35 RX: [c109620400421000002d240b] 2020/05/07 00:20:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36 2020/05/07 00:21:35 RX: [c13f62030000f300002d240e] 2020/05/07 00:21:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.3 2020/05/07 00:25:34 RX: [c133620300ffff0000372402] 2020/05/07 00:25:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 00:26:17 RX: [c11762030000dd0000482500] 2020/05/07 00:26:17 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 00:28:05 RX: [c10162170000eb00de2d2404] 2020/05/07 00:28:05 dropping wheel position on the ground: 22.2 2020/05/07 00:28:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.5 2020/05/07 00:28:15 RX: [c13662170000ce00b52d240d] 2020/05/07 00:28:15 dropping wheel position on the ground: 18.1 2020/05/07 00:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/07 00:30:19 RX: [c13c62420012f97d102d240da5000000431003a503a5000000442407] 2020/05/07 00:30:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 00:30:19 Message not handled [c13c62420012f97d102d240da5000000431003a503a5000000442407] 2020/05/07 00:30:23 RX: [c10f620300011700003b2503] 2020/05/07 00:30:23 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 00:31:25 RX: [c10c62030000fd00002d2409] 2020/05/07 00:31:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/07 00:31:34 RX: [c135620400424ccccd35240b] 2020/05/07 00:31:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.2 2020/05/07 00:32:14 RX: [c13462170000d0000035240c] 2020/05/07 00:32:14 dropping wheel position on the ground: 0.0 2020/05/07 00:32:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/07 00:34:35 RX: [c11562030001030000492507] 2020/05/07 00:34:35 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/07 00:36:34 RX: [c13c624200411bfa10492507a5000000431003a503a5000000452408] 2020/05/07 00:36:34 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 00:36:34 Message not handled [c13c624200411bfa10492507a5000000431003a503a5000000452408] 2020/05/07 00:37:11 RX: [c13e62030000f200003d2405] 2020/05/07 00:37:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.2 2020/05/07 00:42:50 RX: [c13c624200f295ea103d2405a5000000431003a503a5000000452409] 2020/05/07 00:42:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 00:42:50 Message not handled [c13c624200f295ea103d2405a5000000431003a503a5000000452409] 2020/05/07 00:43:35 RX: [c137620400421b33332d2401] 2020/05/07 00:43:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.8 2020/05/07 00:43:51 RX: [c13a62170000c600c13c2400] 2020/05/07 00:43:51 dropping wheel position on the ground: 19.3 2020/05/07 00:43:51 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/07 00:45:11 RX: [c13b620400422a66663c2404] 2020/05/07 00:45:11 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.6 2020/05/07 00:50:10 RX: [c13c623f00e601b9003c2404a5000000431003a503a500000045240a] 2020/05/07 00:50:10 (partially decoded) temp 18.5C moisture 48.6% 2020/05/07 00:50:10 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 00:50:10 Message not handled [c13c623f00e601b9003c2404a5000000431003a503a500000045240a] 2020/05/07 00:50:20 RX: [c13c624200e681db103c2404a5000000431003a503a500000046240b] 2020/05/07 00:50:20 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 00:50:20 Message not handled [c13c624200e681db103c2404a5000000431003a503a500000046240b] 2020/05/07 00:50:35 RX: [c1096204004211999a2d240c] 2020/05/07 00:50:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.4 2020/05/07 00:51:35 RX: [c13f62030000f100002d240f] 2020/05/07 00:51:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.1 2020/05/07 00:55:34 RX: [c133620300ffff0000352403] 2020/05/07 00:55:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 00:56:19 RX: [c11762030000dd0000472502] 2020/05/07 00:56:19 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 00:56:36 RX: [c13c624200be339810472502a5000000431003a503a500000046240c] 2020/05/07 00:56:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 00:56:36 Message not handled [c13c624200be339810472502a5000000431003a503a500000046240c] 2020/05/07 00:58:05 RX: [c10162170000ea00de2d2405] 2020/05/07 00:58:05 dropping wheel position on the ground: 22.2 2020/05/07 00:58:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/07 00:58:15 RX: [c13662170000cd00b52d240e] 2020/05/07 00:58:15 dropping wheel position on the ground: 18.1 2020/05/07 00:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 01:00:00 RX: [c1007339005fcb66004a04201a000000441004] 2020/05/07 01:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 01:00:25 RX: [c10f620300011400003b2505] 2020/05/07 01:00:25 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/07 01:01:25 RX: [c10c62030000fb00002d240a] 2020/05/07 01:01:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 01:01:34 RX: [c135620400424d333335240c] 2020/05/07 01:01:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.3 2020/05/07 01:02:14 RX: [c13462170000d0000036240d] 2020/05/07 01:02:14 dropping wheel position on the ground: 0.0 2020/05/07 01:02:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/07 01:02:51 RX: [c13c62420012bd881036240da5000000441004a503a500000045240d] 2020/05/07 01:02:51 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:02:51 Message not handled [c13c62420012bd881036240da5000000441004a503a500000045240d] 2020/05/07 01:02:55 RX: [c13f62030000ec00002d2400] 2020/05/07 01:02:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/07 01:04:37 RX: [c11562030000ff00004a2509] 2020/05/07 01:04:37 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/07 01:06:55 RX: [c13f62030000f100002d2401] 2020/05/07 01:06:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.1 2020/05/07 01:07:11 RX: [c13e62030000f500003c2406] 2020/05/07 01:07:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/07 01:10:00 RX: [c1007339005fcb66004a04101a000000451005] 2020/05/07 01:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/07 01:13:35 RX: [c137620400421c00002d2402] 2020/05/07 01:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39 2020/05/07 01:13:50 RX: [c13a62170000c500c13d2401] 2020/05/07 01:13:50 dropping wheel position on the ground: 19.3 2020/05/07 01:13:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.7 2020/05/07 01:13:51 RX: [c13e62030000f000003d2407] 2020/05/07 01:13:51 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/07 01:15:10 RX: [c13b620400422a66663d2405] 2020/05/07 01:15:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.6 2020/05/07 01:20:21 RX: [c13c6242005727a9103d2405a5000000451005a503a500000045240e] 2020/05/07 01:20:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:20:21 Message not handled [c13c6242005727a9103d2405a5000000451005a503a500000045240e] 2020/05/07 01:20:35 RX: [c109620400421266662d240d] 2020/05/07 01:20:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.6 2020/05/07 01:22:55 RX: [c13f62030000ef00002d2402] 2020/05/07 01:22:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 01:25:34 RX: [c133620300ffff0000362404] 2020/05/07 01:25:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 01:26:21 RX: [c11762030000dd0000492504] 2020/05/07 01:26:21 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 01:26:36 RX: [c13c624200dea9b910492504a5000000451005a503a500000044240f] 2020/05/07 01:26:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 01:26:36 Message not handled [c13c624200dea9b910492504a5000000451005a503a500000044240f] 2020/05/07 01:28:05 RX: [c10162170000e900de2d2406] 2020/05/07 01:28:05 dropping wheel position on the ground: 22.2 2020/05/07 01:28:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/07 01:28:15 RX: [c13662170000cb00b52d240f] 2020/05/07 01:28:15 dropping wheel position on the ground: 18.1 2020/05/07 01:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.3 2020/05/07 01:30:27 RX: [c10f620300011400003a2507] 2020/05/07 01:30:27 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/07 01:31:25 RX: [c10c62030000fa00002d240b] 2020/05/07 01:31:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 01:31:34 RX: [c135620400424f333336240d] 2020/05/07 01:31:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.8 2020/05/07 01:32:14 RX: [c13462170000d0000036240e] 2020/05/07 01:32:14 dropping wheel position on the ground: 0.0 2020/05/07 01:32:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.8 2020/05/07 01:32:52 RX: [c13c624200124b3e1036240ea5000000451005a503a5000000462400] 2020/05/07 01:32:52 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:32:52 Message not handled [c13c624200124b3e1036240ea5000000451005a503a5000000462400] 2020/05/07 01:34:15 RX: [c13f62030000ea00002d2403] 2020/05/07 01:34:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/07 01:34:39 RX: [c11562030000ff00004a250b] 2020/05/07 01:34:39 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/07 01:37:50 RX: [c13e62030000f400003d2408] 2020/05/07 01:37:50 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 01:40:12 RX: [c13c623f00c201b8003d2408a5000000451005a503a5000000452401] 2020/05/07 01:40:12 (partially decoded) temp 18.4C moisture 45.0% 2020/05/07 01:40:12 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 01:40:12 Message not handled [c13c623f00c201b8003d2408a5000000451005a503a5000000452401] 2020/05/07 01:40:15 RX: [c13f62030000ef00002d2404] 2020/05/07 01:40:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 01:40:22 RX: [c13c624200125f0f102d2404a5000000451005a503a5000000452402] 2020/05/07 01:40:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:40:22 Message not handled [c13c624200125f0f102d2404a5000000451005a503a5000000452402] 2020/05/07 01:41:10 RX: [c13e62030000ef00003c2409] 2020/05/07 01:41:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 01:43:35 RX: [c137620400421ccccd2d2403] 2020/05/07 01:43:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.2 2020/05/07 01:43:50 RX: [c13a62170000c500c13d2402] 2020/05/07 01:43:50 dropping wheel position on the ground: 19.3 2020/05/07 01:43:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.7 2020/05/07 01:45:10 RX: [c13b620400422acccd3d2406] 2020/05/07 01:45:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.7 2020/05/07 01:46:37 RX: [c13c62420012d11f103d2406a5000000451005a503a5000000452403] 2020/05/07 01:46:37 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:46:37 Message not handled [c13c62420012d11f103d2406a5000000451005a503a5000000452403] 2020/05/07 01:46:55 RX: [c13f62030000e900002d2405] 2020/05/07 01:46:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/07 01:50:35 RX: [c109620400421200002d240e] 2020/05/07 01:50:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.5 2020/05/07 01:52:53 RX: [c13c62420012635c102d240ea5000000451005a503a5000000452404] 2020/05/07 01:52:53 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 01:52:53 Message not handled [c13c62420012635c102d240ea5000000451005a503a5000000452404] 2020/05/07 01:54:55 RX: [c13f62030000ed00002d2406] 2020/05/07 01:54:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/07 01:55:34 RX: [c133620300ffff0000342405] 2020/05/07 01:55:34 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 01:56:23 RX: [c11762030000dd0000482506] 2020/05/07 01:56:23 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 01:58:05 RX: [c10162170000e800de2d2407] 2020/05/07 01:58:05 dropping wheel position on the ground: 22.2 2020/05/07 01:58:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/07 01:58:15 RX: [c13662170000ca00b52d2400] 2020/05/07 01:58:15 dropping wheel position on the ground: 18.1 2020/05/07 01:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/07 02:00:00 RX: [c1007339005fcb66004a04201a000000441006] 2020/05/07 02:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 02:00:29 RX: [c10f620300011000003a2509] 2020/05/07 02:00:29 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/07 02:01:25 RX: [c10c62030000f700002d240c] 2020/05/07 02:01:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.7 2020/05/07 02:01:34 RX: [c135620400424f999a35240e] 2020/05/07 02:01:34 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.9 2020/05/07 02:02:14 RX: [c13462170000cf000036240f] 2020/05/07 02:02:14 dropping wheel position on the ground: 0.0 2020/05/07 02:02:14 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 02:04:41 RX: [c11562030000ff00004a250d] 2020/05/07 02:04:41 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/07 02:08:30 RX: [c13e62030000f000003d240a] 2020/05/07 02:08:30 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24 2020/05/07 02:10:00 RX: [c1007339005fcb66004a04101a000000441007] 2020/05/07 02:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/07 02:10:15 RX: [c13f62030000e700002d2407] 2020/05/07 02:10:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/07 02:10:22 RX: [c13c62420012ed4c102d2407a5000000441007a503a5000000462405] 2020/05/07 02:10:22 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:10:22 Message not handled [c13c62420012ed4c102d2407a5000000441007a503a5000000462405] 2020/05/07 02:13:35 RX: [c137620400421d33332d2404] 2020/05/07 02:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.3 2020/05/07 02:13:50 RX: [c13a62170000c300c13d2403] 2020/05/07 02:13:50 dropping wheel position on the ground: 19.3 2020/05/07 02:13:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/07 02:15:10 RX: [c13b620400422b999a3d2407] 2020/05/07 02:15:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.9 2020/05/07 02:16:38 RX: [c13c62420012776d103d2407a5000000441007a503a5000000442406] 2020/05/07 02:16:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:16:38 Message not handled [c13c62420012776d103d2407a5000000441007a503a5000000442406] 2020/05/07 02:17:35 RX: [c13f62030000ec00002d2408] 2020/05/07 02:17:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.6 2020/05/07 02:20:35 RX: [c109620400421200002d240f] 2020/05/07 02:20:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.5 2020/05/07 02:22:54 RX: [c13c62420012f97d102d240fa5000000441007a503a5000000442407] 2020/05/07 02:22:54 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:22:54 Message not handled [c13c62420012f97d102d240fa5000000441007a503a5000000442407] 2020/05/07 02:25:33 RX: [c133620300ffff0000362406] 2020/05/07 02:25:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 02:26:15 RX: [c13f62030000e800002d2409] 2020/05/07 02:26:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/07 02:26:24 RX: [c11762030000dd0000482508] 2020/05/07 02:26:24 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 02:28:05 RX: [c10162170000e800de2d2408] 2020/05/07 02:28:05 dropping wheel position on the ground: 22.2 2020/05/07 02:28:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/07 02:28:15 RX: [c13662170000c900b52d2401] 2020/05/07 02:28:15 dropping wheel position on the ground: 18.1 2020/05/07 02:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/07 02:30:14 RX: [c13c623f00be01b8002d2401a5000000441007a503a5000000442408] 2020/05/07 02:30:14 (partially decoded) temp 18.4C moisture 44.6% 2020/05/07 02:30:14 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 02:30:14 Message not handled [c13c623f00be01b8002d2401a5000000441007a503a5000000442408] 2020/05/07 02:30:24 RX: [c13c624200be95ea102d2401a5000000441007a503a5000000462409] 2020/05/07 02:30:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:30:24 Message not handled [c13c624200be95ea102d2401a5000000441007a503a5000000462409] 2020/05/07 02:30:31 RX: [c10f620300011000003a250b] 2020/05/07 02:30:31 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.2 2020/05/07 02:31:25 RX: [c10c62030000f500002d240d] 2020/05/07 02:31:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/07 02:31:33 RX: [c1356204004250666636240f] 2020/05/07 02:31:33 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 52.1 2020/05/07 02:31:35 RX: [c13f62030000ed00002d240a] 2020/05/07 02:31:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/07 02:32:13 RX: [c13462170000cf0000362400] 2020/05/07 02:32:13 dropping wheel position on the ground: 0.0 2020/05/07 02:32:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 02:34:43 RX: [c11562030000ff00004a250f] 2020/05/07 02:34:43 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.5 2020/05/07 02:34:55 RX: [c13f62030000e800002d240b] 2020/05/07 02:34:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.2 2020/05/07 02:35:10 RX: [c13e62030000eb00003d240b] 2020/05/07 02:35:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.5 2020/05/07 02:36:39 RX: [c13c624200120fcb103d240ba5000000441007a503a500000045240a] 2020/05/07 02:36:39 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:36:39 Message not handled [c13c624200120fcb103d240ba5000000441007a503a500000045240a] 2020/05/07 02:39:10 RX: [c13e62030000ed00003d240c] 2020/05/07 02:39:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/07 02:42:55 RX: [c13c6242007281db103d240ca5000000441007a503a500000045240b] 2020/05/07 02:42:55 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 02:42:55 Message not handled [c13c6242007281db103d240ca5000000441007a503a500000045240b] 2020/05/07 02:43:35 RX: [c137620400421d999a2d2405] 2020/05/07 02:43:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.4 2020/05/07 02:43:50 RX: [c13a62170000c300c13d2404] 2020/05/07 02:43:50 dropping wheel position on the ground: 19.3 2020/05/07 02:43:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/07 02:45:10 RX: [c13b620400422c00003d2408] 2020/05/07 02:45:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43 2020/05/07 02:50:35 RX: [c109620400421333332d2400] 2020/05/07 02:50:35 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.8 2020/05/07 02:55:33 RX: [c133620300ffff0000362407] 2020/05/07 02:55:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 02:56:26 RX: [c11762030000dd000048250a] 2020/05/07 02:56:26 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 02:57:35 RX: [c13f62030000e900002d240c] 2020/05/07 02:57:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/07 02:58:05 RX: [c10162170000e700de2d2409] 2020/05/07 02:58:05 dropping wheel position on the ground: 22.2 2020/05/07 02:58:05 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/07 02:58:15 RX: [c13662170000c700b52d2402] 2020/05/07 02:58:15 dropping wheel position on the ground: 18.1 2020/05/07 02:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/07 03:00:00 RX: [c1007339005fcb66004a04201a000000441008] 2020/05/07 03:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 03:00:24 RX: [c13c624200203398104a04201a000000441008a503a500000045240c] 2020/05/07 03:00:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 03:00:24 Message not handled [c13c624200203398104a04201a000000441008a503a500000045240c] 2020/05/07 03:00:33 RX: [c10f620300010d00003b250d] 2020/05/07 03:00:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 26.9 2020/05/07 03:01:25 RX: [c10c62030000f400002d240e] 2020/05/07 03:01:25 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 03:01:33 RX: [c13562040042500000362400] 2020/05/07 03:01:33 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 52 2020/05/07 03:02:13 RX: [c13462170000cf0000352401] 2020/05/07 03:02:13 dropping wheel position on the ground: 0.0 2020/05/07 03:02:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 03:04:45 RX: [c11562030000fc0000492501] 2020/05/07 03:04:45 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.2 2020/05/07 03:06:40 RX: [c13c624200cfbd8810492501a5000000441008a503a500000046240d] 2020/05/07 03:06:40 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 03:06:40 Message not handled [c13c624200cfbd8810492501a5000000441008a503a500000046240d] 2020/05/07 03:09:10 RX: [c13e62030000ef00003d240d] 2020/05/07 03:09:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 03:10:00 RX: [c1007339005fcb66004a04101a000000431009] 2020/05/07 03:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/07 03:12:56 RX: [c13c6242005227a9104a04101a000000431009a503a500000044240e] 2020/05/07 03:12:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 03:12:56 Message not handled [c13c6242005227a9104a04101a000000431009a503a500000044240e] 2020/05/07 03:13:35 RX: [c137620400421e00002d2406] 2020/05/07 03:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.5 2020/05/07 03:13:36 RX: [c13f62030000e400002d240d] 2020/05/07 03:13:36 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.8 2020/05/07 03:13:50 RX: [c13a62170000c200c13d2405] 2020/05/07 03:13:50 dropping wheel position on the ground: 19.3 2020/05/07 03:13:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 03:15:00 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 03:15:00 RX: [c1147000010000000035100c] 2020/05/07 03:15:00 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 03:15:02 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 03:15:02 RX: [c11870000100000000421001] 2020/05/07 03:15:02 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 03:15:06 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/07 03:15:06 RX: [c110700001000000004e100f] 2020/05/07 03:15:06 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal weak, cyclic false) status switched on 2020/05/07 03:15:10 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/07 03:15:10 RX: [c13b620400422c66663d2409] 2020/05/07 03:15:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.1 2020/05/07 03:15:11 RX: [c13e62030000ea00003d240e] 2020/05/07 03:15:11 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/07 03:15:12 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/07 03:17:05 RX: [c10f620300011400003a250f] 2020/05/07 03:17:05 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.6 2020/05/07 03:20:16 RX: [c13c623f00bb01b7003a250fa5004210011009a503a500000046240f] 2020/05/07 03:20:16 (partially decoded) temp 18.3C moisture 44.3% 2020/05/07 03:20:16 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT OUT 2020/05/07 03:20:16 Message not handled [c13c623f00bb01b7003a250fa5004210011009a503a500000046240f] 2020/05/07 03:20:26 RX: [c13c624200bb4b3e103a250fa5004210011009a503a5000000442400] 2020/05/07 03:20:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/07 03:20:26 Message not handled [c13c624200bb4b3e103a250fa5004210011009a503a5000000442400] 2020/05/07 03:20:34 RX: [c109620400421333332d2401] 2020/05/07 03:20:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.8 2020/05/07 03:21:50 RX: [c13e62030000ef00003d240f] 2020/05/07 03:21:50 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 03:22:29 RX: [c10f620300011e00003a2500] 2020/05/07 03:22:29 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/07 03:23:54 RX: [c10c62030000fb00002d240f] 2020/05/07 03:23:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 03:25:33 RX: [c133620300ffff0000362408] 2020/05/07 03:25:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 03:26:15 RX: [c13f62030000e900002d240e] 2020/05/07 03:26:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.3 2020/05/07 03:26:28 RX: [c11762030000dd000047250c] 2020/05/07 03:26:28 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 03:26:41 RX: [c13c6242005ec52e1047250ca5004210011009a503a5000000452401] 2020/05/07 03:26:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 03:26:41 Message not handled [c13c6242005ec52e1047250ca5004210011009a503a5000000452401] 2020/05/07 03:28:04 RX: [c10162170000e600de2d240a] 2020/05/07 03:28:04 dropping wheel position on the ground: 22.2 2020/05/07 03:28:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/07 03:28:15 RX: [c13662170000c600b52d2403] 2020/05/07 03:28:15 dropping wheel position on the ground: 18.1 2020/05/07 03:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.8 2020/05/07 03:28:30 RX: [c10f620300012500003f2501] 2020/05/07 03:28:30 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 03:28:30 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 03:28:30 RX: [c13e62030000f400003c2400] 2020/05/07 03:28:30 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 03:28:31 RX: [c11870000000000000431003] 2020/05/07 03:28:31 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 03:28:54 RX: [c10c620300010300002d2400] 2020/05/07 03:28:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.9 2020/05/07 03:28:55 RX: [c13f62030000e700002d240f] 2020/05/07 03:28:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/07 03:29:42 MQTT message; topic: 'xcomfort/26/set/switch', message: 'false' 2020/05/07 03:29:44 RX: [c100733900b3f868004d000100001e00000051100d] 2020/05/07 03:29:44 Device 6879411, type CDAU 01/04 sent extended status message: value 0, temp 30C (battery mains-powered, signal weak) 2020/05/07 03:31:33 RX: [c135620400424f999a352401] 2020/05/07 03:31:33 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.9 2020/05/07 03:32:13 RX: [c13462170000cf0000342402] 2020/05/07 03:32:13 dropping wheel position on the ground: 0.0 2020/05/07 03:32:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 03:32:56 RX: [c13c624200125f0f10342402a5001e00000051100da5000000452402] 2020/05/07 03:32:56 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 03:32:56 Message not handled [c13c624200125f0f10342402a5001e00000051100da5000000452402] 2020/05/07 03:33:04 RX: [c10c620300010700002d2401] 2020/05/07 03:33:04 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/07 03:34:47 RX: [c115620300010300004a2503] 2020/05/07 03:34:47 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 25.9 2020/05/07 03:35:24 RX: [c10f620300011b00003b2502] 2020/05/07 03:35:24 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/07 03:35:24 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 03:35:25 RX: [c11870000100000000451005] 2020/05/07 03:35:25 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 03:37:10 RX: [c13e62030000f900003d2401] 2020/05/07 03:37:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 03:38:54 RX: [c10c620300010f00002d2402] 2020/05/07 03:38:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/07 03:41:24 RX: [c10f620300012200003b2503] 2020/05/07 03:41:24 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 03:41:50 RX: [c13e62030000fb00003d2402] 2020/05/07 03:41:50 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 03:43:35 RX: [c137620400421f33332d2407] 2020/05/07 03:43:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/07 03:43:50 RX: [c13a62170000c200c13d2406] 2020/05/07 03:43:50 dropping wheel position on the ground: 19.3 2020/05/07 03:43:50 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 03:45:10 RX: [c13b620400422ccccd3d240a] 2020/05/07 03:45:10 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.2 2020/05/07 03:47:10 RX: [c13e620300010000003d2403] 2020/05/07 03:47:10 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/07 03:47:10 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/07 03:47:26 RX: [c10f620300012900003b2505] 2020/05/07 03:47:26 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 03:47:26 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 03:47:27 RX: [c11870000000000000441007] 2020/05/07 03:47:27 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 03:49:44 RX: [c10c620300011800002d2403] 2020/05/07 03:49:44 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28 2020/05/07 03:49:45 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 03:49:45 RX: [c1147000000000000035100e] 2020/05/07 03:49:45 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 03:50:26 RX: [c13c62420027d11f1035100ea5002d24030051100da5000000462403] 2020/05/07 03:50:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 03:50:26 Message not handled [c13c62420027d11f1035100ea5002d24030051100da5000000462403] 2020/05/07 03:50:34 RX: [c1096204004212cccd2d2402] 2020/05/07 03:50:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.7 2020/05/07 03:53:26 RX: [c10f620300012200003b2506] 2020/05/07 03:53:26 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 03:55:33 RX: [c133620300ffff0000372409] 2020/05/07 03:55:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 03:56:30 RX: [c11762030000dd000047250e] 2020/05/07 03:56:30 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 03:56:41 RX: [c13c6242007e635c1047250ea5002d24030051100da5000000442404] 2020/05/07 03:56:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 03:56:41 Message not handled [c13c6242007e635c1047250ea5002d24030051100da5000000442404] 2020/05/07 03:58:04 RX: [c10162170000e700de2d240b] 2020/05/07 03:58:04 dropping wheel position on the ground: 22.2 2020/05/07 03:58:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/07 03:58:15 RX: [c13662170000c700b52d2404] 2020/05/07 03:58:15 dropping wheel position on the ground: 18.1 2020/05/07 03:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.9 2020/05/07 03:58:51 RX: [c10f620300011700003a2507] 2020/05/07 03:58:51 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 03:58:51 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 03:58:51 RX: [c11870000100000000411009] 2020/05/07 03:58:51 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 03:58:55 RX: [c13f62030000e500002d2400] 2020/05/07 03:58:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/07 04:00:00 RX: [c1007339005fcb66004a04201a00000044100a] 2020/05/07 04:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 04:01:33 RX: [c135620400424f999a352402] 2020/05/07 04:01:33 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.9 2020/05/07 04:02:13 RX: [c13462170000ce0000362403] 2020/05/07 04:02:13 dropping wheel position on the ground: 0.0 2020/05/07 04:02:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/07 04:02:29 RX: [c13e62030000fb00003c2404] 2020/05/07 04:02:29 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 04:02:57 RX: [c13c62420012ed4c103c2404a500000044100aa50da5000000452405] 2020/05/07 04:02:57 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 04:02:57 Message not handled [c13c62420012ed4c103c2404a500000044100aa50da5000000452405] 2020/05/07 04:03:57 RX: [c10f620300012200003b2508] 2020/05/07 04:03:57 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 04:04:44 RX: [c10c620300011500002d2404] 2020/05/07 04:04:44 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/07 04:04:49 RX: [c115620300010a0000492505] 2020/05/07 04:04:49 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 26.6 2020/05/07 04:05:35 RX: [c13f62030000ea00002d2401] 2020/05/07 04:05:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.4 2020/05/07 04:10:00 RX: [c1007339005fcb66004a04101a00000043100b] 2020/05/07 04:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/07 04:10:18 RX: [c13c623f00ba01b7004a04101a00000043100ba50da5000000452406] 2020/05/07 04:10:18 (partially decoded) temp 18.3C moisture 44.2% 2020/05/07 04:10:18 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT OUT 2020/05/07 04:10:18 Message not handled [c13c623f00ba01b7004a04101a00000043100ba50da5000000452406] 2020/05/07 04:10:28 RX: [c13c624200baf97d104a04101a00000043100ba50da5000000452407] 2020/05/07 04:10:28 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 04:10:28 Message not handled [c13c624200baf97d104a04101a00000043100ba50da5000000452407] 2020/05/07 04:12:23 RX: [c10f620300012900003a250a] 2020/05/07 04:12:23 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 04:12:23 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 04:12:24 RX: [c1187000000000000045100b] 2020/05/07 04:12:24 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 04:13:09 RX: [c13e62030000fd00003d2405] 2020/05/07 04:13:09 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/07 04:13:35 RX: [c137620400421ecccd2d2408] 2020/05/07 04:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.7 2020/05/07 04:13:49 RX: [c13a62170000c300c13c2407] 2020/05/07 04:13:49 dropping wheel position on the ground: 19.3 2020/05/07 04:13:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/07 04:15:09 RX: [c13b620400422c00003d240b] 2020/05/07 04:15:09 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43 2020/05/07 04:16:43 RX: [c13c624200121bfa103d240ba5003a250a100ba50da5000000442408] 2020/05/07 04:16:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 04:16:43 Message not handled [c13c624200121bfa103d240ba5003a250a100ba50da5000000442408] 2020/05/07 04:18:23 RX: [c10f620300012200003b250b] 2020/05/07 04:18:23 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 04:20:34 RX: [c109620400421266662d2403] 2020/05/07 04:20:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.6 2020/05/07 04:20:35 RX: [c10c620300010e00002d2405] 2020/05/07 04:20:35 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/07 04:22:35 RX: [c10f620300011700003b250c] 2020/05/07 04:22:35 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 04:22:35 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 04:22:36 RX: [c1187000010000000041100d] 2020/05/07 04:22:36 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 04:22:58 RX: [c13c6242002795ea1041100da5003b250c100ba50da5000000462409] 2020/05/07 04:22:58 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 04:22:58 Message not handled [c13c6242002795ea1041100da5003b250c100ba50da5000000462409] 2020/05/07 04:23:35 RX: [c13f62030000ef00002d2402] 2020/05/07 04:23:35 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.9 2020/05/07 04:25:33 RX: [c133620300ffff000036240a] 2020/05/07 04:25:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 04:26:32 RX: [c11762030000d60000482500] 2020/05/07 04:26:32 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/07 04:26:48 RX: [c10f620300012200003a250d] 2020/05/07 04:26:48 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 04:28:04 RX: [c10162170000e700de2d240c] 2020/05/07 04:28:04 dropping wheel position on the ground: 22.2 2020/05/07 04:28:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23.1 2020/05/07 04:28:15 RX: [c13662170000c800b52d2405] 2020/05/07 04:28:15 dropping wheel position on the ground: 18.1 2020/05/07 04:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/07 04:30:15 RX: [c13f62030000ed00002d2403] 2020/05/07 04:30:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 23.7 2020/05/07 04:31:33 RX: [c13562040042500000352403] 2020/05/07 04:31:33 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 52 2020/05/07 04:31:38 RX: [c13c623f00ba01b700352403a5003b250c100ba50da500000044240a] 2020/05/07 04:31:38 (partially decoded) temp 18.3C moisture 44.2% 2020/05/07 04:31:38 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 04:31:38 Message not handled [c13c623f00ba01b700352403a5003b250c100ba50da500000044240a] 2020/05/07 04:32:13 RX: [c13462170000ce0000352404] 2020/05/07 04:32:13 dropping wheel position on the ground: 0.0 2020/05/07 04:32:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/07 04:33:54 RX: [c10c620300010700002d2406] 2020/05/07 04:33:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.3 2020/05/07 04:33:54 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 04:33:55 RX: [c11470000100000000351000] 2020/05/07 04:33:55 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 04:34:51 RX: [c11562030001110000492507] 2020/05/07 04:34:51 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 27.3 2020/05/07 04:35:12 RX: [c10f620300012900003a250e] 2020/05/07 04:35:12 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 04:35:12 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 04:35:13 RX: [c1187000000000000044100f] 2020/05/07 04:35:13 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 04:35:49 RX: [c13e62030000f800003d2406] 2020/05/07 04:35:49 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/07 04:36:24 RX: [c10c620300010900002d2407] 2020/05/07 04:36:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.5 2020/05/07 04:40:28 RX: [c13c6242001281db102d2407a5003a250e100ba50da500000045240b] 2020/05/07 04:40:28 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 04:40:28 Message not handled [c13c6242001281db102d2407a5003a250e100ba50da500000045240b] 2020/05/07 04:41:12 RX: [c10f620300012200003a250f] 2020/05/07 04:41:12 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 04:41:24 RX: [c10c620300011000002d2408] 2020/05/07 04:41:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/07 04:43:35 RX: [c137620400421e66662d2409] 2020/05/07 04:43:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.6 2020/05/07 04:43:49 RX: [c13a62170000c300c13c2408] 2020/05/07 04:43:49 dropping wheel position on the ground: 19.3 2020/05/07 04:43:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.5 2020/05/07 04:43:50 RX: [c13e62030000fa00003d2407] 2020/05/07 04:43:50 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 04:45:08 RX: [c10f620300011700003b2501] 2020/05/07 04:45:08 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 04:45:08 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 04:45:09 RX: [c11870000100000000431001] 2020/05/07 04:45:09 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 04:45:09 RX: [c13b620400422c66663d240c] 2020/05/07 04:45:09 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.1 2020/05/07 04:46:43 RX: [c13c624200123398103d240ca5003b2501100ba50da500000045240c] 2020/05/07 04:46:43 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 04:46:43 Message not handled [c13c624200123398103d240ca5003b2501100ba50da500000045240c] 2020/05/07 04:46:55 RX: [c13f62030000f300002d2404] 2020/05/07 04:46:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.3 2020/05/07 04:46:56 RX: [c115620300011c00004b2508] 2020/05/07 04:46:56 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.4 2020/05/07 04:46:56 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/07 04:46:57 RX: [c110700000000000004d1001] 2020/05/07 04:46:57 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal weak, cyclic false) status switched off 2020/05/07 04:47:14 RX: [c10c620300011700002d2409] 2020/05/07 04:47:14 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 04:47:14 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 04:47:15 RX: [c11470000000000000351002] 2020/05/07 04:47:15 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 04:49:03 RX: [c10f620300012200003a2502] 2020/05/07 04:49:03 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 04:50:34 RX: [c109620400421333332d2404] 2020/05/07 04:50:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 36.8 2020/05/07 04:52:59 RX: [c13c62420012bd88102d2404a5002d2409100ba50da500000045240d] 2020/05/07 04:52:59 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 04:52:59 Message not handled [c13c62420012bd88102d2404a5002d2409100ba50da500000045240d] 2020/05/07 04:55:33 RX: [c133620300ffff000036240b] 2020/05/07 04:55:33 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 04:56:34 RX: [c11762030000dd0000482502] 2020/05/07 04:56:34 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 04:58:04 RX: [c10162170000e600de2d240d] 2020/05/07 04:58:04 dropping wheel position on the ground: 22.2 2020/05/07 04:58:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/07 04:58:15 RX: [c13662170000c900b52d2406] 2020/05/07 04:58:15 dropping wheel position on the ground: 18.1 2020/05/07 04:58:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/07 04:59:15 RX: [c10f620300012900003a2503] 2020/05/07 04:59:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 04:59:15 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 04:59:16 RX: [c11870000000000000431003] 2020/05/07 04:59:16 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 05:00:00 RX: [c1007339005fcb66004a04201a00000044100c] 2020/05/07 05:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 26C (battery mains-powered, signal normal) 2020/05/07 05:00:19 RX: [c13c623f00ba01b7004a04201a00000044100ca50da500000045240e] 2020/05/07 05:00:19 (partially decoded) temp 18.3C moisture 44.2% 2020/05/07 05:00:19 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT OUT 2020/05/07 05:00:19 Message not handled [c13c623f00ba01b7004a04201a00000044100ca50da500000045240e] 2020/05/07 05:00:29 RX: [c13c624200baa9b9104a04201a00000044100ca50da500000045240f] 2020/05/07 05:00:29 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 05:00:29 Message not handled [c13c624200baa9b9104a04201a00000044100ca50da500000045240f] 2020/05/07 05:00:55 RX: [c13f62030000f400002d2405] 2020/05/07 05:00:55 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 05:01:32 RX: [c13562040042500000362404] 2020/05/07 05:01:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 52 2020/05/07 05:02:13 RX: [c13462170000cf0000362405] 2020/05/07 05:02:13 dropping wheel position on the ground: 0.0 2020/05/07 05:02:13 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 05:05:15 RX: [c10f620300012200003a2504] 2020/05/07 05:05:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 05:06:45 RX: [c13c624200124b3e103a2504a500000044100ca50da5000000462400] 2020/05/07 05:06:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal good, cyclic true) RCT REQ 2020/05/07 05:06:45 Message not handled [c13c624200124b3e103a2504a500000044100ca50da5000000462400] 2020/05/07 05:08:04 RX: [c10c620300011500002d240a] 2020/05/07 05:08:04 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/07 05:09:28 RX: [c10f620300011700003a2505] 2020/05/07 05:09:28 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 05:09:28 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 05:09:28 RX: [c11870000100000000421005] 2020/05/07 05:09:28 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 05:10:00 RX: [c1007339005fcb66004a04101a00000043100d] 2020/05/07 05:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/07 05:13:00 RX: [c13c624200d2c52e104a04101a00000043100da50da5000000452401] 2020/05/07 05:13:00 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 05:13:00 Message not handled [c13c624200d2c52e104a04101a00000043100da50da5000000452401] 2020/05/07 05:13:35 RX: [c137620400421e66662d240a] 2020/05/07 05:13:35 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.6 2020/05/07 05:13:49 RX: [c13a62170000c200c13d2409] 2020/05/07 05:13:49 dropping wheel position on the ground: 19.3 2020/05/07 05:13:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 05:13:50 RX: [c13e62030000f900003d2408] 2020/05/07 05:13:50 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 05:14:17 RX: [c10f620300012200003a2507] 2020/05/07 05:14:17 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 05:15:09 RX: [c13b620400422d33333d240d] 2020/05/07 05:15:09 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.3 2020/05/07 05:16:46 RX: [c10370006200000000491003] 2020/05/07 05:16:46 Device 5734031 (channel 0-'1.etg sov 3') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/07 05:16:58 RX: [c1156203000119000049250a] 2020/05/07 05:16:58 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal normal, cyclic true) event 'value' with value 28.1 2020/05/07 05:18:25 RX: [c111700001000000003a100e] 2020/05/07 05:18:25 Device 5727252 (channel 0-'utelys hovedd�r') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 05:18:29 RX: [c108700062000000003c1007] 2020/05/07 05:18:29 Device 5734000 (channel 0-'1.etg stor gang') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/07 05:19:49 RX: [c13e62030000f300003d2409] 2020/05/07 05:19:49 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.3 2020/05/07 05:19:49 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/07 05:19:56 RX: [c10670006200000000541006] 2020/05/07 05:19:56 Device 5736891 (channel 0-'1.etg bad speil') sent message (battery mains-powered, signal weak, cyclic false) value 98 2020/05/07 05:20:00 RX: [c102700062000000004f1008] 2020/05/07 05:20:00 Device 5740117 (channel 0-'1.etg sov 4') sent message (battery mains-powered, signal weak, cyclic false) value 98 2020/05/07 05:20:15 RX: [c13f62030000f900002d2406] 2020/05/07 05:20:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 05:20:34 RX: [c109620400421400002d2405] 2020/05/07 05:20:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37 2020/05/07 05:20:46 RX: [c11762030000d20000472504] 2020/05/07 05:20:46 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/07 05:21:32 RX: [c1197000620000000037100d] 2020/05/07 05:21:32 Device 5740172 (channel 0-'1.etg dusj/bad') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/07 05:22:14 RX: [c10c620300010e00002d240b] 2020/05/07 05:22:14 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/07 05:23:09 RX: [c13e62030000f800003d240a] 2020/05/07 05:23:09 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/07 05:23:18 RX: [c10f620300012900003b2508] 2020/05/07 05:23:18 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 05:23:18 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 05:23:18 RX: [c11870000000000000451007] 2020/05/07 05:23:18 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 05:25:32 RX: [c133620300ffff000036240c] 2020/05/07 05:25:32 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 05:26:12 RX: [c113700062000000002d100b] 2020/05/07 05:26:12 Device 5734274 (channel 0-'1.etg kj�kken spotter') sent message (battery mains-powered, signal good, cyclic false) value 98 2020/05/07 05:26:13 RX: [c10d70006200000000451004] 2020/05/07 05:26:13 Device 5741956 (channel 0-'1.etg stue lampe spi') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/07 05:26:14 RX: [c13f62030000f400002d2407] 2020/05/07 05:26:14 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 05:28:04 RX: [c10162170000e500de2d240e] 2020/05/07 05:28:04 dropping wheel position on the ground: 22.2 2020/05/07 05:28:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/07 05:28:15 RX: [c13662170000c900b52d2407] 2020/05/07 05:28:15 dropping wheel position on the ground: 18.1 2020/05/07 05:28:15 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/07 05:29:18 RX: [c10f620300012200003b2509] 2020/05/07 05:29:18 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 05:29:34 RX: [c13f62030000f900002d2408] 2020/05/07 05:29:34 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 05:30:30 RX: [c13c624200125f0f102d2408a5002d100b100da50da5000000442402] 2020/05/07 05:30:30 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 05:30:30 Message not handled [c13c624200125f0f102d2408a5002d100b100da50da5000000442402] 2020/05/07 05:31:32 RX: [c135620400424d3333372405] 2020/05/07 05:31:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.3 2020/05/07 05:32:12 RX: [c13462170000ce0000372406] 2020/05/07 05:32:12 dropping wheel position on the ground: 0.0 2020/05/07 05:32:12 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/07 05:32:29 RX: [c13e62030000fd00003c240b] 2020/05/07 05:32:29 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/07 05:32:29 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/07 05:32:54 RX: [c13f62030000f600002d2409] 2020/05/07 05:32:54 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.6 2020/05/07 05:33:30 RX: [c10f6203000117000039250a] 2020/05/07 05:33:30 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 05:33:30 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 05:33:31 RX: [c11870000100000000431009] 2020/05/07 05:33:31 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 05:36:45 RX: [c13c62420028d11f10431009a50039250a100da50da5000000452403] 2020/05/07 05:36:45 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 05:36:45 Message not handled [c13c62420028d11f10431009a50039250a100da50da5000000452403] 2020/05/07 05:37:03 RX: [c11762030000dd0000482506] 2020/05/07 05:37:03 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 22.1 2020/05/07 05:38:19 RX: [c10f620300012200003a250b] 2020/05/07 05:38:19 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 05:38:54 RX: [c10c620300010e00002d240c] 2020/05/07 05:38:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27 2020/05/07 05:41:17 RX: [c103700000000000004a1005] 2020/05/07 05:41:17 Device 5734031 (channel 0-'1.etg sov 3') sent message (battery mains-powered, signal normal, cyclic false) value 0 2020/05/07 05:42:37 RX: [c1007339006c0469004d0002ff001e0000003d1006] 2020/05/07 05:42:37 Device 6882412, type CDAU 01/04 sent extended status message: value 255, temp 30C (battery mains-powered, signal good) 2020/05/07 05:42:38 RX: [c1007339008e0269004d0002ff001d0000002d1004] 2020/05/07 05:42:38 Device 6881934, type CDAU 01/04 sent extended status message: value 255, temp 29C (battery mains-powered, signal good) 2020/05/07 05:43:01 RX: [c13c62420002635c104d0002ff001d0000002d1004a5000000472404] 2020/05/07 05:43:01 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery N/A, signal weak, cyclic false) RCT REQ 2020/05/07 05:43:01 Message not handled [c13c62420002635c104d0002ff001d0000002d1004a5000000472404] 2020/05/07 05:43:34 RX: [c137620400421d999a2d240b] 2020/05/07 05:43:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.4 2020/05/07 05:43:49 RX: [c13a62170000c200c13d240a] 2020/05/07 05:43:49 dropping wheel position on the ground: 19.3 2020/05/07 05:43:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 05:45:09 RX: [c13b620400422ccccd3d240e] 2020/05/07 05:45:09 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.2 2020/05/07 05:45:23 RX: [c11762030000d20000492507] 2020/05/07 05:45:23 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/07 05:45:49 RX: [c13e62030000fd00003d240c] 2020/05/07 05:45:49 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/07 05:47:00 RX: [c115620300011100004c250c] 2020/05/07 05:47:00 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27.3 2020/05/07 05:47:02 RX: [c10f6203000129000039250d] 2020/05/07 05:47:02 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 05:47:03 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 05:47:03 RX: [c1187000000000000044100b] 2020/05/07 05:47:03 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 05:50:21 RX: [c13c623f00b901b60044100ba50039250d002d1004a5000000462405] 2020/05/07 05:50:21 (partially decoded) temp 18.2C moisture 44.1% 2020/05/07 05:50:21 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT OUT 2020/05/07 05:50:21 Message not handled [c13c623f00b901b60044100ba50039250d002d1004a5000000462405] 2020/05/07 05:50:31 RX: [c13c624200b9776d1044100ba50039250d002d1004a5000000442406] 2020/05/07 05:50:31 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/07 05:50:31 Message not handled [c13c624200b9776d1044100ba50039250d002d1004a5000000442406] 2020/05/07 05:50:34 RX: [c109620400421600002c2406] 2020/05/07 05:50:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 37.5 2020/05/07 05:52:14 RX: [c13f62030000fb00002d240a] 2020/05/07 05:52:14 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 05:53:03 RX: [c10f6203000122000039250e] 2020/05/07 05:53:03 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 05:53:09 RX: [c13e62030000f800003d240d] 2020/05/07 05:53:09 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/07 05:55:32 RX: [c133620300ffff000035240d] 2020/05/07 05:55:32 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 05:56:47 RX: [c13c62420012f97d1035240da50039250d002d1004a5000000432407] 2020/05/07 05:56:47 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 05:56:47 Message not handled [c13c62420012f97d1035240da50039250d002d1004a5000000432407] 2020/05/07 05:57:28 RX: [c10770006200000000491004] 2020/05/07 05:57:28 Device 5736925 (channel 0-'1.etg bad tak') sent message (battery mains-powered, signal normal, cyclic false) value 98 2020/05/07 05:57:33 RX: [c10f6203000117000038250f] 2020/05/07 05:57:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 05:57:33 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 05:57:34 RX: [c1187000010000000041100d] 2020/05/07 05:57:34 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 05:58:04 RX: [c10162170000e500de2d240f] 2020/05/07 05:58:04 dropping wheel position on the ground: 22.2 2020/05/07 05:58:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/07 05:58:14 RX: [c13662170000c900b52c2408] 2020/05/07 05:58:14 dropping wheel position on the ground: 18.1 2020/05/07 05:58:14 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.1 2020/05/07 06:00:00 RX: [c1007339005fcb66004a04201900000043100e] 2020/05/07 06:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal good) 2020/05/07 06:01:27 RX: [c10f62030001220000382500] 2020/05/07 06:01:27 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 06:01:32 RX: [c135620400424ccccd342406] 2020/05/07 06:01:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.2 2020/05/07 06:02:12 RX: [c13462170000ce0000352407] 2020/05/07 06:02:12 dropping wheel position on the ground: 0.0 2020/05/07 06:02:12 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.6 2020/05/07 06:03:02 RX: [c13c624200121bfa10352407a500000043100ea504a5000000452408] 2020/05/07 06:03:02 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 06:03:02 Message not handled [c13c624200121bfa10352407a500000043100ea504a5000000452408] 2020/05/07 06:03:09 RX: [c13e62030000fd00003c240e] 2020/05/07 06:03:09 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.3 2020/05/07 06:03:34 RX: [c13f62030000fb00002c240b] 2020/05/07 06:03:34 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 06:08:40 RX: [c10f62030001290000392501] 2020/05/07 06:08:40 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 06:08:40 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 06:08:41 RX: [c1187000000000000043100f] 2020/05/07 06:08:41 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 06:08:54 RX: [c10c620300010a00002d240d] 2020/05/07 06:08:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.6 2020/05/07 06:08:54 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 06:08:54 RX: [c11470000100000000361004] 2020/05/07 06:08:54 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 06:10:00 RX: [c1007339005fcb66004a04101a00000042100f] 2020/05/07 06:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal good) 2020/05/07 06:11:09 RX: [c13e62030000f800003c240f] 2020/05/07 06:11:09 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/07 06:13:34 RX: [c137620400421866662d240c] 2020/05/07 06:13:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38.1 2020/05/07 06:13:42 RX: [c13c623f00bb01b6002d240ca500000042100fa504a5000000462409] 2020/05/07 06:13:42 (partially decoded) temp 18.2C moisture 44.3% 2020/05/07 06:13:42 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 06:13:42 Message not handled [c13c623f00bb01b6002d240ca500000042100fa504a5000000462409] 2020/05/07 06:13:49 RX: [c13a62170000c200c13c240b] 2020/05/07 06:13:49 dropping wheel position on the ground: 19.3 2020/05/07 06:13:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 06:14:42 RX: [c10f62030001220000392503] 2020/05/07 06:14:42 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 06:15:09 RX: [c13b620400422b33333b240f] 2020/05/07 06:15:09 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.8 2020/05/07 06:15:25 RX: [c11762030000d60000472509] 2020/05/07 06:15:25 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/07 06:15:34 RX: [c13f620300010000002d240c] 2020/05/07 06:15:34 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/07 06:15:34 MQTT message; topic: 'xcomfort/39/set/switch', message: 'false' 2020/05/07 06:16:24 RX: [c10c620300011100002d240e] 2020/05/07 06:16:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/07 06:16:24 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 06:16:24 RX: [c11470000000000000361006] 2020/05/07 06:16:24 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 06:17:02 RX: [c115620300010e00004c250e] 2020/05/07 06:17:02 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27 2020/05/07 06:17:02 MQTT message; topic: 'xcomfort/16/set/switch', message: 'true' 2020/05/07 06:17:02 RX: [c11070000100000000471003] 2020/05/07 06:17:02 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 06:17:49 RX: [c13e62030000fa00003c2400] 2020/05/07 06:17:49 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 06:20:06 RX: [c10f62030001170000392504] 2020/05/07 06:20:06 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 06:20:06 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 06:20:07 RX: [c11870000100000000411001] 2020/05/07 06:20:07 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 06:20:32 RX: [c13c624200260fcb10411001a500392504100fa504a500000044240a] 2020/05/07 06:20:32 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 06:20:32 Message not handled [c13c624200260fcb10411001a500392504100fa504a500000044240a] 2020/05/07 06:20:34 RX: [c109620400421800002d2407] 2020/05/07 06:20:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 38 2020/05/07 06:23:04 RX: [c10c620300011800002d240f] 2020/05/07 06:23:04 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 28 2020/05/07 06:24:00 RX: [c10f62030001220000392505] 2020/05/07 06:24:00 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 06:25:32 RX: [c133620300ffff000035240e] 2020/05/07 06:25:32 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 06:26:47 RX: [c13c6242001281db1035240ea500392504100fa504a500000045240b] 2020/05/07 06:26:47 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 06:26:47 Message not handled [c13c6242001281db1035240ea500392504100fa504a500000045240b] 2020/05/07 06:28:04 RX: [c10162170000e500de2d2400] 2020/05/07 06:28:04 dropping wheel position on the ground: 22.2 2020/05/07 06:28:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/07 06:28:14 RX: [c13662170000ca00b52d2409] 2020/05/07 06:28:14 dropping wheel position on the ground: 18.1 2020/05/07 06:28:14 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/07 06:31:32 RX: [c135620400424a0000342407] 2020/05/07 06:31:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.5 2020/05/07 06:31:49 RX: [c10f620300012900003a2506] 2020/05/07 06:31:49 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.7 2020/05/07 06:31:49 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 06:31:49 RX: [c11870000000000000441003] 2020/05/07 06:31:49 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 06:32:12 RX: [c13462170000cd0000352408] 2020/05/07 06:32:12 dropping wheel position on the ground: 0.0 2020/05/07 06:32:12 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 06:32:14 RX: [c10c620300011100002d2400] 2020/05/07 06:32:14 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.3 2020/05/07 06:33:03 RX: [c13c624200123398102d2400a5003a2506100fa504a500000045240c] 2020/05/07 06:33:03 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 06:33:03 Message not handled [c13c624200123398102d2400a5003a2506100fa504a500000045240c] 2020/05/07 06:34:14 RX: [c13f62030000ff00002d240d] 2020/05/07 06:34:14 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/07 06:38:07 RX: [c10f620300012200003a2507] 2020/05/07 06:38:07 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 06:40:11 RX: [c100733900d80269004d0002ff0022000000361005] 2020/05/07 06:40:11 Device 6882008, type CDAU 01/04 sent extended status message: value 255, temp 34C (battery mains-powered, signal good) 2020/05/07 06:40:12 RX: [c100733900b4fa68004d0002ff001a000000431006] 2020/05/07 06:40:12 Device 6879924, type CDAU 01/04 sent extended status message: value 255, temp 26C (battery mains-powered, signal good) 2020/05/07 06:40:23 RX: [c13c623f00b701b7004d0002ff001a000000431006a500000045240d] 2020/05/07 06:40:23 (partially decoded) temp 18.3C moisture 43.9% 2020/05/07 06:40:23 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery N/A, signal weak, cyclic false) RCT OUT 2020/05/07 06:40:23 Message not handled [c13c623f00b701b7004d0002ff001a000000431006a500000045240d] 2020/05/07 06:40:33 RX: [c13c624200b727a9104d0002ff001a000000431006a500000045240e] 2020/05/07 06:40:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery N/A, signal weak, cyclic false) RCT REQ 2020/05/07 06:40:33 Message not handled [c13c624200b727a9104d0002ff001a000000431006a500000045240e] 2020/05/07 06:41:24 RX: [c10c620300010d00002c2401] 2020/05/07 06:41:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/07 06:43:34 RX: [c137620400421c00002d240d] 2020/05/07 06:43:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39 2020/05/07 06:43:49 RX: [c13a62170000c200c13d240c] 2020/05/07 06:43:49 dropping wheel position on the ground: 19.3 2020/05/07 06:43:49 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.4 2020/05/07 06:44:09 RX: [c10f620300011b0000382509] 2020/05/07 06:44:09 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/07 06:44:09 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 06:44:09 RX: [c11870000100000000411005] 2020/05/07 06:44:09 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 06:45:08 RX: [c13b620400422c66663c2400] 2020/05/07 06:45:08 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.1 2020/05/07 06:45:27 RX: [c11762030000d6000046250b] 2020/05/07 06:45:27 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21.4 2020/05/07 06:46:48 RX: [c13c624200caa9b91046250ba50038250900431006a500000045240f] 2020/05/07 06:46:48 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 06:46:48 Message not handled [c13c624200caa9b91046250ba50038250900431006a500000045240f] 2020/05/07 06:47:04 RX: [c115620300011500004f2500] 2020/05/07 06:47:04 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 27.7 2020/05/07 06:47:48 RX: [c13e62030000f500003c2401] 2020/05/07 06:47:48 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/07 06:47:49 MQTT message; topic: 'xcomfort/35/set/switch', message: 'true' 2020/05/07 06:48:28 RX: [c13e62030000f500003c2402] 2020/05/07 06:48:28 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.5 2020/05/07 06:49:18 RX: [c100733900070569004d0002ff001f000000411002] 2020/05/07 06:49:18 Device 6882567, type CDAU 01/04 sent extended status message: value 255, temp 31C (battery mains-powered, signal good) 2020/05/07 06:50:09 RX: [c10f6203000122000038250a] 2020/05/07 06:50:09 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29 2020/05/07 06:50:34 RX: [c109620400421f33332d2408] 2020/05/07 06:50:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.8 2020/05/07 06:53:04 RX: [c13c624200124b3e102d2408a5001f000000411002a5000000462400] 2020/05/07 06:53:04 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 06:53:04 Message not handled [c13c624200124b3e102d2408a5001f000000411002a5000000462400] 2020/05/07 06:53:54 RX: [c10c620300010600002d2402] 2020/05/07 06:53:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.2 2020/05/07 06:53:54 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 06:53:54 RX: [c11470000100000000351008] 2020/05/07 06:53:54 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 06:55:32 RX: [c133620300ffff000035240f] 2020/05/07 06:55:32 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 06:55:33 RX: [c10f620300012c000039250b] 2020/05/07 06:55:33 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 30 2020/05/07 06:55:34 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 06:55:34 RX: [c11870000000000000431007] 2020/05/07 06:55:34 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 06:57:48 RX: [c13e62030000fa00003b2403] 2020/05/07 06:57:48 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 06:58:04 RX: [c10162170000e500de2d2401] 2020/05/07 06:58:04 dropping wheel position on the ground: 22.2 2020/05/07 06:58:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 22.9 2020/05/07 06:58:14 RX: [c13662170000cd00b52d240a] 2020/05/07 06:58:14 dropping wheel position on the ground: 18.1 2020/05/07 06:58:14 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 06:58:15 RX: [c13f62030000f900002d240e] 2020/05/07 06:58:15 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 07:00:00 RX: [c1007339005fcb66004a042019000000441000] 2020/05/07 07:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/07 07:01:32 RX: [c135620400424b3333372408] 2020/05/07 07:01:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 50.8 2020/05/07 07:01:34 RX: [c10f6203000125000038250c] 2020/05/07 07:01:34 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 07:02:12 RX: [c13462170000cd0000352409] 2020/05/07 07:02:12 dropping wheel position on the ground: 0.0 2020/05/07 07:02:12 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 07:03:04 RX: [c10c620300010d00002d2403] 2020/05/07 07:03:04 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/07 07:04:54 RX: [c13f62030000fa00002d240f] 2020/05/07 07:04:54 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25 2020/05/07 07:06:22 RX: [c10f620300011b000038250d] 2020/05/07 07:06:22 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.3 2020/05/07 07:06:22 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 07:06:23 RX: [c11870000100000000461009] 2020/05/07 07:06:23 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 07:08:04 RX: [c10c620300011500002d2404] 2020/05/07 07:08:04 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.7 2020/05/07 07:08:04 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 07:08:04 RX: [c1147000000000000036100a] 2020/05/07 07:08:04 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 07:09:08 RX: [c13e620300010000003b2404] 2020/05/07 07:09:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/07 07:09:09 MQTT message; topic: 'xcomfort/35/set/switch', message: 'false' 2020/05/07 07:10:00 RX: [c1007339005fcb66004a04101a000000441001] 2020/05/07 07:10:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/07 07:10:33 RX: [c13c62420010c52e104a04101a000000441001a502a5000000452401] 2020/05/07 07:10:33 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal normal, cyclic false) RCT REQ 2020/05/07 07:10:33 Message not handled [c13c62420010c52e104a04101a000000441001a502a5000000452401] 2020/05/07 07:11:28 RX: [c10f6203000125000039250e] 2020/05/07 07:11:28 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 07:11:29 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 07:11:29 RX: [c1187000000000000046100b] 2020/05/07 07:11:29 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 07:13:08 RX: [c13e620300010500003c2405] 2020/05/07 07:13:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.1 2020/05/07 07:13:34 RX: [c137620400421f999a2d240e] 2020/05/07 07:13:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 39.9 2020/05/07 07:13:48 RX: [c13a62170000c400c13c240d] 2020/05/07 07:13:48 dropping wheel position on the ground: 19.3 2020/05/07 07:13:48 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 19.6 2020/05/07 07:13:54 RX: [c10c620300011400002d2405] 2020/05/07 07:13:54 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.6 2020/05/07 07:15:08 RX: [c13b620400422ecccd3c2401] 2020/05/07 07:15:08 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.7 2020/05/07 07:15:29 RX: [c11762030000d2000047250d] 2020/05/07 07:15:29 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/07 07:16:49 RX: [c13c624200cd5f0f1047250da50039250e1001a502a5000000452402] 2020/05/07 07:16:49 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery new, signal normal, cyclic true) RCT REQ 2020/05/07 07:16:49 Message not handled [c13c624200cd5f0f1047250da50039250e1001a502a5000000452402] 2020/05/07 07:18:06 RX: [c10f620300011e0000392500] 2020/05/07 07:18:06 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/07 07:18:06 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 07:18:07 RX: [c1187000010000000048100d] 2020/05/07 07:18:07 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 07:19:08 RX: [c13e620300010000003c2406] 2020/05/07 07:19:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/07 07:20:34 RX: [c109620400422a00002d2409] 2020/05/07 07:20:34 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 42.5 2020/05/07 07:21:08 RX: [c13e62030000ff00003c2407] 2020/05/07 07:21:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.5 2020/05/07 07:23:05 RX: [c13c62420012d11f103c2407a5003925001001a502a5000000452403] 2020/05/07 07:23:05 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 07:23:05 Message not handled [c13c62420012d11f103c2407a5003925001001a502a5000000452403] 2020/05/07 07:24:06 RX: [c10f62030001250000392501] 2020/05/07 07:24:06 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 07:24:07 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 07:24:07 RX: [c1187000000000000047100f] 2020/05/07 07:24:07 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 07:25:32 RX: [c133620300ffff0000352400] 2020/05/07 07:25:32 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 07:27:14 RX: [c10c620300010d00002c2406] 2020/05/07 07:27:14 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/07 07:28:04 RX: [c10162170000e600de2d2402] 2020/05/07 07:28:04 dropping wheel position on the ground: 22.2 2020/05/07 07:28:04 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/07 07:28:14 RX: [c13662170000cf00b52c240b] 2020/05/07 07:28:14 dropping wheel position on the ground: 18.1 2020/05/07 07:28:14 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 07:30:25 RX: [c13c623f00b801b7002c240ba5003925011001a502a5000000452404] 2020/05/07 07:30:25 (partially decoded) temp 18.3C moisture 44.0% 2020/05/07 07:30:25 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 07:30:25 Message not handled [c13c623f00b801b7002c240ba5003925011001a502a5000000452404] 2020/05/07 07:30:35 RX: [c13c624200b8ed4c102c240ba5003925011001a502a5000000442405] 2020/05/07 07:30:35 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 07:30:35 Message not handled [c13c624200b8ed4c102c240ba5003925011001a502a5000000442405] 2020/05/07 07:31:32 RX: [c135620400424ccccd342409] 2020/05/07 07:31:32 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.2 2020/05/07 07:32:12 RX: [c13462170000cd000036240a] 2020/05/07 07:32:12 dropping wheel position on the ground: 0.0 2020/05/07 07:32:12 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 07:34:19 RX: [c10f620300011e0000392502] 2020/05/07 07:34:19 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/07 07:34:19 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 07:34:20 RX: [c11870000100000000471001] 2020/05/07 07:34:20 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 07:34:54 RX: [c13f62030000f800002d2400] 2020/05/07 07:34:54 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.8 2020/05/07 07:36:24 RX: [c10c620300010600002d2407] 2020/05/07 07:36:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.2 2020/05/07 07:36:24 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 07:36:24 RX: [c1147000010000000035100c] 2020/05/07 07:36:24 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 07:36:50 RX: [c13c62420024776d1035100ca5002d24071001a502a5000000452406] 2020/05/07 07:36:50 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 07:36:50 Message not handled [c13c62420024776d1035100ca5002d24071001a502a5000000452406] 2020/05/07 07:40:19 RX: [c10f62030001250000382503] 2020/05/07 07:40:19 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 07:40:19 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 07:40:20 RX: [c11870000000000000461003] 2020/05/07 07:40:20 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 07:43:06 RX: [c13c624200f2f97d10461003a5003825031001a502a5000000452407] 2020/05/07 07:43:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal normal, cyclic false) RCT REQ 2020/05/07 07:43:06 Message not handled [c13c624200f2f97d10461003a5003825031001a502a5000000452407] 2020/05/07 07:43:34 RX: [c1376204004221999a2d240f] 2020/05/07 07:43:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.4 2020/05/07 07:43:48 RX: [c13a62170000c800c13c240e] 2020/05/07 07:43:48 dropping wheel position on the ground: 19.3 2020/05/07 07:43:48 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20 2020/05/07 07:44:43 RX: [c10c620300010d00002d2408] 2020/05/07 07:44:43 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.9 2020/05/07 07:45:08 RX: [c13b620400422f33333c2402] 2020/05/07 07:45:08 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 43.8 2020/05/07 07:45:31 RX: [c11762030000d2000047250f] 2020/05/07 07:45:31 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/07 07:46:24 RX: [c10c620300010f00002d2409] 2020/05/07 07:46:24 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.1 2020/05/07 07:50:15 RX: [c10f620300011e0000392505] 2020/05/07 07:50:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/07 07:50:15 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 07:50:16 RX: [c11870000100000000451005] 2020/05/07 07:50:16 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched on 2020/05/07 07:50:33 RX: [c109620400423000002d240a] 2020/05/07 07:50:33 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44 2020/05/07 07:51:08 RX: [c13e620300010100003d2408] 2020/05/07 07:51:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.7 2020/05/07 07:52:13 RX: [c10c620300011700002d240a] 2020/05/07 07:52:13 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.9 2020/05/07 07:52:14 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 07:52:14 RX: [c1147000000000000035100e] 2020/05/07 07:52:14 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off 2020/05/07 07:54:26 RX: [c13c623f00b901b70035100ea5002d240a1001a502a5000000452408] 2020/05/07 07:54:26 (partially decoded) temp 18.3C moisture 44.1% 2020/05/07 07:54:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT OUT 2020/05/07 07:54:26 Message not handled [c13c623f00b901b70035100ea5002d240a1001a502a5000000452408] 2020/05/07 07:54:28 RX: [c13e62030000fb00003c2409] 2020/05/07 07:54:28 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 07:55:31 RX: [c133620300ffff0000352401] 2020/05/07 07:55:31 Device 6809944 (channel 6-'kjeller bad temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value -0.1 2020/05/07 07:56:15 RX: [c10f62030001250000392506] 2020/05/07 07:56:15 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 07:56:16 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 07:56:16 RX: [c11870000000000000471007] 2020/05/07 07:56:16 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 07:58:03 RX: [c10162170000e600de2d2403] 2020/05/07 07:58:03 dropping wheel position on the ground: 22.2 2020/05/07 07:58:03 Device 6784078 (channel 0-'1.etg dusj/bad (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 23 2020/05/07 07:58:14 RX: [c13662170000cf00b52d240c] 2020/05/07 07:58:14 dropping wheel position on the ground: 18.1 2020/05/07 07:58:14 Device 6783968 (channel 0-'kjeller inngang temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.7 2020/05/07 07:59:06 RX: [c13c623f00bb01b8002d240ca5003925061001a502a5000000452409] 2020/05/07 07:59:06 (partially decoded) temp 18.4C moisture 44.3% 2020/05/07 07:59:06 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 07:59:06 Message not handled [c13c623f00bb01b8002d240ca5003925061001a502a5000000452409] 2020/05/07 08:00:00 RX: [c1007339005fcb66004a042019000000441002] 2020/05/07 08:00:00 Device 6736735, type CSAU 01/01-16 sent extended status message: status ON, temp 25C (battery mains-powered, signal normal) 2020/05/07 08:01:08 RX: [c13e620300010000003c240a] 2020/05/07 08:01:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.6 2020/05/07 08:01:09 RX: [c13c624200120fcb103c240aa5000000441002a502a500000045240a] 2020/05/07 08:01:09 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 08:01:09 Message not handled [c13c624200120fcb103c240aa5000000441002a502a500000045240a] 2020/05/07 08:01:31 RX: [c135620400424f999a36240a] 2020/05/07 08:01:31 Device 6809944 (channel 1-'kjeller bad temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 51.9 2020/05/07 08:02:11 RX: [c13462170000cd000035240b] 2020/05/07 08:02:11 dropping wheel position on the ground: 0.0 2020/05/07 08:02:11 Device 6809944 (channel 0-'kjeller bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.5 2020/05/07 08:03:02 RX: [c11562030001330000522506] 2020/05/07 08:03:02 Device 5881271 (channel 1-'1.etg bad temp (Kanal A)') sent message (battery new, signal weak, cyclic true) event 'value' with value 30.7 2020/05/07 08:03:02 MQTT message; topic: 'xcomfort/16/set/switch', message: 'false' 2020/05/07 08:03:02 RX: [c11070000000000000491005] 2020/05/07 08:03:02 Device 5727387 (channel 0-'1.etg bad vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 08:04:54 RX: [c13f62030000f900002d2401] 2020/05/07 08:04:54 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.9 2020/05/07 08:07:22 RX: [c10f620300011e0000392507] 2020/05/07 08:07:22 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 28.6 2020/05/07 08:07:22 MQTT message; topic: 'xcomfort/24/set/switch', message: 'true' 2020/05/07 08:07:23 RX: [c11870000100000000431009] 2020/05/07 08:07:23 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 08:07:24 RX: [c13c6242002581db10431009a5003925071002a502a500000047240b] 2020/05/07 08:07:24 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery mains-powered, signal good, cyclic false) RCT REQ 2020/05/07 08:07:24 Message not handled [c13c6242002581db10431009a5003925071002a502a500000047240b] 2020/05/07 08:08:03 RX: [c10c620300011000002d240b] 2020/05/07 08:08:03 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.2 2020/05/07 08:08:14 RX: [c13f62030000f400002d2402] 2020/05/07 08:08:14 Device 6783968 (channel 6-'kjeller inngang temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 24.4 2020/05/07 08:08:14 MQTT message; topic: 'xcomfort/39/set/switch', message: 'true' 2020/05/07 08:09:08 RX: [c13e62030000fb00003c240b] 2020/05/07 08:09:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 08:10:01 RX: [c1007339005fcb66004a04101a000000441003] 2020/05/07 08:10:01 Device 6736735, type CSAU 01/01-16 sent extended status message: status OFF, temp 26C (battery mains-powered, signal normal) 2020/05/07 08:13:23 RX: [c10f62030001250000392509] 2020/05/07 08:13:23 Device 5881341 (channel 1-'1.etg stor gang temp (Kanal A)') sent message (battery new, signal good, cyclic true) event 'value' with value 29.3 2020/05/07 08:13:24 MQTT message; topic: 'xcomfort/24/set/switch', message: 'false' 2020/05/07 08:13:24 RX: [c1187000000000000048100b] 2020/05/07 08:13:24 Device 5733583 (channel 0-'1.etg stor gang vk') sent message (battery mains-powered, signal normal, cyclic false) status switched off 2020/05/07 08:13:34 RX: [c1376204004220cccd2d2400] 2020/05/07 08:13:34 Device 6783968 (channel 1-'kjeller inngang temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 40.2 2020/05/07 08:13:41 RX: [c13c624200123398102d2400a5003925091003a502a500000044240c] 2020/05/07 08:13:41 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 08:13:41 Message not handled [c13c624200123398102d2400a5003925091003a502a500000044240c] 2020/05/07 08:13:48 RX: [c13a62170000ca00c13c240f] 2020/05/07 08:13:48 dropping wheel position on the ground: 19.3 2020/05/07 08:13:48 Device 6807667 (channel 0-'kjeller vaskerom temp (Temperatur)') sent message (battery good, signal good, cyclic true) event 'value' with value 20.2 2020/05/07 08:15:08 RX: [c13b620400423066663c2403] 2020/05/07 08:15:08 Device 6807667 (channel 1-'kjeller vaskerom temp (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 44.1 2020/05/07 08:15:32 RX: [c11762030000d20000482501] 2020/05/07 08:15:32 Device 5881353 (channel 1-'1.etg liten gang temp (Kanal B)') sent message (battery new, signal normal, cyclic true) event 'value' with value 21 2020/05/07 08:15:33 RX: [c10c620300010900002d240c] 2020/05/07 08:15:33 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.5 2020/05/07 08:15:34 MQTT message; topic: 'xcomfort/20/set/switch', message: 'true' 2020/05/07 08:15:34 RX: [c11470000100000000361000] 2020/05/07 08:15:34 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched on 2020/05/07 08:18:53 RX: [c10c620300010b00002d240d] 2020/05/07 08:18:53 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 26.7 2020/05/07 08:20:26 RX: [c13c623f00c001b8002d240da5002d240c1003a502a500000046240d] 2020/05/07 08:20:26 (partially decoded) temp 18.4C moisture 44.8% 2020/05/07 08:20:26 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT OUT 2020/05/07 08:20:26 Message not handled [c13c623f00c001b8002d240da5002d240c1003a502a500000046240d] 2020/05/07 08:20:33 RX: [c109620400423f999a2d240b] 2020/05/07 08:20:33 Device 6784078 (channel 1-'1.etg dusj/bad (Fuktighet)') sent message (battery good, signal good, cyclic true) event 'value' with value 47.9 2020/05/07 08:20:36 RX: [c13c6242001227a9102d240ba5002d240c1003a502a500000046240e] 2020/05/07 08:20:36 Device 7417943 (channel 0-'hybel bad temp (Temperatur)') sent message (battery good, signal good, cyclic true) RCT REQ 2020/05/07 08:20:36 Message not handled [c13c6242001227a9102d240ba5002d240c1003a502a500000046240e] 2020/05/07 08:23:08 RX: [c13e62030000fb00003c240c] 2020/05/07 08:23:08 Device 6807667 (channel 6-'kjeller vaskerom temp (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 25.1 2020/05/07 08:24:43 RX: [c10c620300011200002d240e] 2020/05/07 08:24:43 Device 6784078 (channel 6-'1.etg dusj/bad (ekstern Sensor (PT1000))') sent message (battery good, signal good, cyclic true) event 'value' with value 27.4 2020/05/07 08:24:44 MQTT message; topic: 'xcomfort/20/set/switch', message: 'false' 2020/05/07 08:24:44 RX: [c11470000000000000361002] 2020/05/07 08:24:44 Device 5727267 (channel 0-'1.etg dusj/bad vk') sent message (battery mains-powered, signal good, cyclic false) status switched off