The spiService app requires device /dev/spidev0.0, but that device file does not exist on wp76xx and wp77xx modules. On those modules, the device that should be used instead is /dev/spidev1.0.
The text was updated successfully, but these errors were encountered:
dpfrey
added a commit
to dpfrey/legato-af
that referenced
this issue
Feb 21, 2018
Providing a buildVar to specify the SPI primary bus allows for the
override of the default (0) when the primary SPI bus differs. The WP76
for example uses bus 1 as it's primary SPI bus.
Resolves: legatoproject#23
dpfrey
added a commit
to dpfrey/legato-af
that referenced
this issue
Feb 22, 2018
Providing a buildVar to specify the SPI primary bus allows for the
override of the default (0) when the primary SPI bus differs. The WP76
for example uses bus 1 as it's primary SPI bus.
Resolves: legatoproject#23
The spiService app requires device /dev/spidev0.0, but that device file does not exist on wp76xx and wp77xx modules. On those modules, the device that should be used instead is /dev/spidev1.0.