Merge pull request #1244 from Calvario/master
Browse files Browse the repository at this point in the history
UPS Support for Synology
  • Loading branch information
f0o committed Jun 11, 2015
2 parents 5677ad7 + ced0804 commit 4153a8f
Show file tree
Hide file tree
Showing 3 changed files with 123 additions and 0 deletions.
33 changes: 33 additions & 0 deletions includes/discovery/charge/dsm.inc.php
@@ -0,0 +1,33 @@
<?php

/*
* LibreNMS
*
* Copyright (c) 2015 Steve Calvário <https://github.com/Calvario/>
*
* This program is free software: you can redistribute it and/or modify it
* under the terms of the GNU General Public License as published by the
* Free Software Foundation, either version 3 of the License, or (at your
* option) any later version. Please see LICENSE.txt at the top level of
* the source code distribution for details.
*/

if ($device['os'] == "dsm") {

echo "DSM UPS Charge";

// UPS Device Manufacturer, example return : SNMPv2-SMI::enterprises.6574.4.1.2.0 = STRING: "American Power Conversion"
$ups_device_manufacturer_oid = '.1.3.6.1.4.1.6574.4.1.2.0';
$ups_device_manufacturer = str_replace('"', '', snmp_get($device, $ups_device_manufacturer_oid, "-Oqv"));
// UPS Device Model, example return : SNMPv2-SMI::enterprises.6574.4.1.1.0 = STRING: "Back-UPS RS 900G"
$ups_device_model_oid = '.1.3.6.1.4.1.6574.4.1.1.0';
$ups_device_model = str_replace('"', '', snmp_get($device, $ups_device_model_oid, "-Oqv"));


// UPS Battery Charge Value, example return : SNMPv2-SMI::enterprises.6574.4.3.1.1.0 = Opaque: Float: 100.000000
$ups_charge_oid = '.1.3.6.1.4.1.6574.4.3.1.1.0';
$ups_charge = snmp_get($device, $ups_charge_oid, "-Oqv");
if(is_numeric($ups_charge)) {
discover_sensor($valid['sensor'], 'charge', $device, $ups_charge_oid, 'UPSChargeValue', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Charge Value', '1', '1', 0, 10, NULL, 100, $ups_charge);
}
}
33 changes: 33 additions & 0 deletions includes/discovery/power/dsm.inc.php
@@ -0,0 +1,33 @@
<?php

/*
* LibreNMS
*
* Copyright (c) 2015 Steve Calvário <https://github.com/Calvario/>
*
* This program is free software: you can redistribute it and/or modify it
* under the terms of the GNU General Public License as published by the
* Free Software Foundation, either version 3 of the License, or (at your
* option) any later version. Please see LICENSE.txt at the top level of
* the source code distribution for details.
*/

if ($device['os'] == "dsm") {

echo "DSM UPS Power";

// UPS Device Manufacturer, example return : SNMPv2-SMI::enterprises.6574.4.1.2.0 = STRING: "American Power Conversion"
$ups_device_manufacturer_oid = '.1.3.6.1.4.1.6574.4.1.2.0';
$ups_device_manufacturer = str_replace('"', '', snmp_get($device, $ups_device_manufacturer_oid, "-Oqv"));
// UPS Device Model, example return : SNMPv2-SMI::enterprises.6574.4.1.1.0 = STRING: "Back-UPS RS 900G"
$ups_device_model_oid = '.1.3.6.1.4.1.6574.4.1.1.0';
$ups_device_model = str_replace('"', '', snmp_get($device, $ups_device_model_oid, "-Oqv"));


// UPS Info Real Power Nominal, example return : SNMPv2-SMI::enterprises.6574.4.2.21.2.0 = Opaque: Float: 540.000000
$ups_real_power_nominal_oid = '.1.3.6.1.4.1.6574.4.2.21.2.0';
$ups_real_power_nominal = snmp_get($device, $ups_real_power_nominal_oid, "-Oqv");
if (is_numeric($ups_real_power_nominal)) {
discover_sensor($valid['sensor'], 'power', $device, $ups_real_power_nominal_oid, 'UPSRealPowerNominal', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Real Power Nominal', '1', '1', NULL, NULL, NULL, NULL, $ups_real_power_nominal);
}
}
57 changes: 57 additions & 0 deletions includes/discovery/voltages/dsm.inc.php
@@ -0,0 +1,57 @@
<?php

/*
* LibreNMS
*
* Copyright (c) 2015 Steve Calvário <https://github.com/Calvario/>
*
* This program is free software: you can redistribute it and/or modify it
* under the terms of the GNU General Public License as published by the
* Free Software Foundation, either version 3 of the License, or (at your
* option) any later version. Please see LICENSE.txt at the top level of
* the source code distribution for details.
*/

if ($device['os'] == "dsm") {

echo "DSM UPS Voltage";

// UPS Device Manufacturer, example return : SNMPv2-SMI::enterprises.6574.4.1.2.0 = STRING: "American Power Conversion"
$ups_device_manufacturer_oid = '.1.3.6.1.4.1.6574.4.1.2.0';
$ups_device_manufacturer = str_replace('"', '', snmp_get($device, $ups_device_manufacturer_oid, "-Oqv"));
// UPS Device Model, example return : SNMPv2-SMI::enterprises.6574.4.1.1.0 = STRING: "Back-UPS RS 900G"
$ups_device_model_oid = '.1.3.6.1.4.1.6574.4.1.1.0';
$ups_device_model = str_replace('"', '', snmp_get($device, $ups_device_model_oid, "-Oqv"));


// UPS Input Voltage Value, example return : SNMPv2-SMI::enterprises.6574.4.4.1.1.0 = Opaque: Float: 234.000000
$ups_input_voltage_oid = '.1.3.6.1.4.1.6574.4.4.1.1.0';
$ups_input_voltage = snmp_get($device, $ups_input_voltage_oid, "-Oqv");
if (is_numeric($ups_input_voltage)) {
discover_sensor($valid['sensor'], 'voltage', $device, $ups_input_voltage_oid, 'UPSInputVoltageValue', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Input Voltage Value', '1', '1', NULL, NULL, NULL, NULL, $ups_input_voltage);
}


// UPS Input Voltage Nominal, example return : SNMPv2-SMI::enterprises.6574.4.4.1.4.0 = Opaque: Float: 230.000000
$ups_input_voltage_nominal_oid = '.1.3.6.1.4.1.6574.4.4.1.4.0';
$ups_input_voltage_nominal = snmp_get($device, $ups_input_voltage_nominal_oid, "-Oqv");
if (is_numeric($ups_input_voltage_nominal)) {
discover_sensor($valid['sensor'], 'voltage', $device, $ups_input_voltage_nominal_oid, 'UPSInputVoltageNominal', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Input Voltage Nominal', '1', '1', NULL, NULL, NULL, NULL, $ups_input_voltage_nominal);
}


// UPS Battery Voltage Value, example return : SNMPv2-SMI::enterprises.6574.4.3.2.1.0 = Opaque: Float: 27.000000
$ups_battery_voltage_oid = '.1.3.6.1.4.1.6574.4.3.2.1.0';
$ups_battery_voltage = snmp_get($device, $ups_battery_voltage_oid, "-Oqv");
if (is_numeric($ups_battery_voltage)) {
discover_sensor($valid['sensor'], 'voltage', $device, $ups_battery_voltage_oid, 'UPSBatteryVoltage', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Battery Voltage', '1', '1', NULL, NULL, NULL, NULL, $ups_battery_voltage);
}


// UPS Battery Voltage Nominal, example return : SNMPv2-SMI::enterprises.6574.4.3.2.2.0 = Opaque: Float: 24.000000
$ups_battery_voltage_nominal_oid = '.1.3.6.1.4.1.6574.4.3.2.2.0';
$ups_battery_voltage_nominal = snmp_get($device, $ups_battery_voltage_nominal_oid, "-Oqv");
if (is_numeric($ups_battery_voltage_nominal)) {
discover_sensor($valid['sensor'], 'voltage', $device, $ups_battery_voltage_nominal_oid, 'SystemStatus', $ups_device_manufacturer.' '.$ups_device_model, 'UPS Battery Voltage Nominal', '1', '1', NULL, NULL, NULL, NULL, $ups_battery_voltage_nominal);
}
}