LibreNMS Discovery Version info: Commit SHA: 0997172b37dd261c3f44873372b247a18ab8610e DB Schema: 166 PHP: 7.0.8-0ubuntu0.16.04.1 MySQL: 10.0.25-MariaDB-0ubuntu0.16.04.1 RRDTool: 1.5.5 SNMP: NET-SNMP 5.7.3 DEBUG! SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1] DB Schema already up to date. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'company_Tesla_linkx' ORDER BY device_id DESC] SQL[SELECT * FROM devices_attribs WHERE `device_id` = '29'] company_Tesla_linkx 29 ios SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('5','5','0','3.49','5.28','4.59','29',NOW())] SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m SNMPv2-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 sysObjectID.0] SNMPv2-SMI::enterprises.9.1.1045 SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '29' AND `attrib_type` = 'poll_mib' ] Modules status: Global+ OS Device #### Load disco module os #### SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0] Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9_NPE-M), Version 15.1(4)M4, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2012 by Cisco Systems, Inc. Compiled Tue 20-Mar-12 18:57 by prod_rel_team SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0] .*.*.1045 | Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9_NPE-M), Version 15.1(4)M4, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2012 by Cisco Systems, Inc. Compiled Tue 20-Mar-12 18:57 by prod_rel_team | .1.3.6.1.4.1.9.1.1045 | SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ENTITY-MIB::entPhysicalDescr.1] CISCO2911/K9 chassis SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 SML-MIB::product-Name.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'os': 0.2420 seconds with 3968 bytes #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifDescr] ifDescr.1 = GigabitEthernet0/0/0 ifDescr.2 = Embedded-Service-Engine0/0 ifDescr.3 = GigabitEthernet0/0 ifDescr.4 = GigabitEthernet0/1 ifDescr.5 = GigabitEthernet0/2 ifDescr.6 = GigabitEthernet0/3 ifDescr.7 = Null0 ifDescr.8 = Loopback0 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifName] ifName.1 = Gi0/0/0 ifName.2 = Em0/0 ifName.3 = Gi0/0 ifName.4 = Gi0/1 ifName.5 = Gi0/2 ifName.6 = Gi0/3 ifName.7 = Nu0 ifName.8 = Lo0 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifAlias] ifAlias.1 = Link to Tesla WAN & Remote ifAlias.2 = ifAlias.3 = Interface to Tesla ifAlias.4 = WAN interfact into companys ME network ifAlias.5 = ifAlias.6 = ifAlias.7 = ifAlias.8 = SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifType] ifType.1 = ethernetCsmacd ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = ethernetCsmacd ifType.6 = ethernetCsmacd ifType.7 = other ifType.8 = softwareLoopback Array ( [1] => Array ( [ifDescr] => GigabitEthernet0/0/0 [ifName] => Gi0/0/0 [ifAlias] => Link to Tesla WAN & Remote [ifType] => ethernetCsmacd ) [2] => Array ( [ifDescr] => Embedded-Service-Engine0/0 [ifName] => Em0/0 [ifAlias] => [ifType] => ethernetCsmacd ) [3] => Array ( [ifDescr] => GigabitEthernet0/0 [ifName] => Gi0/0 [ifAlias] => Interface to Tesla [ifType] => ethernetCsmacd ) [4] => Array ( [ifDescr] => GigabitEthernet0/1 [ifName] => Gi0/1 [ifAlias] => WAN interfact into companys ME network [ifType] => ethernetCsmacd ) [5] => Array ( [ifDescr] => GigabitEthernet0/2 [ifName] => Gi0/2 [ifAlias] => [ifType] => ethernetCsmacd ) [6] => Array ( [ifDescr] => GigabitEthernet0/3 [ifName] => Gi0/3 [ifAlias] => [ifType] => ethernetCsmacd ) [7] => Array ( [ifDescr] => Null0 [ifName] => Nu0 [ifAlias] => [ifType] => other ) [8] => Array ( [ifDescr] => Loopback0 [ifName] => Lo0 [ifAlias] => [ifType] => softwareLoopback ) ) SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1'] SQL[SELECT * FROM `ports` WHERE `device_id` = '29' ORDER BY port_id] ........ >> Runtime for discovery module 'ports': 0.0770 seconds with 2184 bytes #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '29'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifStackStatus] >> Runtime for discovery module 'ports-stack': 0.0100 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalEntry] entPhysicalDescr.1 = CISCO2911/K9 chassis entPhysicalDescr.2 = C2911 Chassis Slot entPhysicalDescr.3 = C2911 Mother board 3GE, integrated VPN and 4W entPhysicalDescr.4 = C2911 DaughterCard Slot entPhysicalDescr.5 = Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu entPhysicalDescr.6 = EHWIC-1GE-SFP-CU entPhysicalDescr.7 = C2911 DaughterCard Slot entPhysicalDescr.8 = C2911 DaughterCard Slot entPhysicalDescr.9 = C2911 DaughterCard Slot entPhysicalDescr.10 = C2911 DaughterCard Slot entPhysicalDescr.11 = C2911 DaughterCard Slot entPhysicalDescr.12 = C2911 DaughterCard Slot entPhysicalDescr.13 = C2911 Chassis Slot entPhysicalDescr.14 = C2911 ISM Slot entPhysicalDescr.15 = Embedded Service Engine entPhysicalDescr.16 = CN Gigabit Ethernet entPhysicalDescr.17 = CN Gigabit Ethernet entPhysicalDescr.18 = CN Gigabit Ethernet entPhysicalDescr.19 = Container of powerSupply Containers entPhysicalDescr.20 = Container of Power Supply entPhysicalDescr.21 = C2911 AC Power Supply entPhysicalDescr.22 = Container of RPS entPhysicalDescr.23 = EHWIC-1GE-SFP-CU SFP Container entPhysicalVendorType.1 = cevChassisC2911 entPhysicalVendorType.2 = cevContainerSlot entPhysicalVendorType.3 = cevCpu29113ge entPhysicalVendorType.4 = cevContainerDaughterCard entPhysicalVendorType.5 = cevEHwic1GeSfpCu entPhysicalVendorType.6 = cevPortGEIP entPhysicalVendorType.7 = cevContainerDaughterCard entPhysicalVendorType.8 = cevContainerDaughterCard entPhysicalVendorType.9 = cevContainerDaughterCard entPhysicalVendorType.10 = cevContainerDaughterCard entPhysicalVendorType.11 = cevContainerDaughterCard entPhysicalVendorType.12 = cevContainerDaughterCard entPhysicalVendorType.13 = cevContainerSlot entPhysicalVendorType.14 = cevContainerSlot entPhysicalVendorType.15 = cevPortSM entPhysicalVendorType.16 = cevPortGEIP entPhysicalVendorType.17 = cevPortGEIP entPhysicalVendorType.18 = cevPortGEIP entPhysicalVendorType.19 = cevContainerPowerSupplyBay entPhysicalVendorType.20 = cevContainerPowerSupply entPhysicalVendorType.21 = cevPowerSupplyC2911PWRAC entPhysicalVendorType.22 = cevContainerPowerSupply entPhysicalVendorType.23 = cevContainerSFP entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 2 entPhysicalContainedIn.4 = 3 entPhysicalContainedIn.5 = 4 entPhysicalContainedIn.6 = 5 entPhysicalContainedIn.7 = 3 entPhysicalContainedIn.8 = 3 entPhysicalContainedIn.9 = 3 entPhysicalContainedIn.10 = 3 entPhysicalContainedIn.11 = 3 entPhysicalContainedIn.12 = 3 entPhysicalContainedIn.13 = 1 entPhysicalContainedIn.14 = 1 entPhysicalContainedIn.15 = 3 entPhysicalContainedIn.16 = 3 entPhysicalContainedIn.17 = 3 entPhysicalContainedIn.18 = 3 entPhysicalContainedIn.19 = 1 entPhysicalContainedIn.20 = 19 entPhysicalContainedIn.21 = 20 entPhysicalContainedIn.22 = 19 entPhysicalContainedIn.23 = 6 entPhysicalClass.1 = chassis entPhysicalClass.2 = container entPhysicalClass.3 = module entPhysicalClass.4 = container entPhysicalClass.5 = module entPhysicalClass.6 = port entPhysicalClass.7 = container entPhysicalClass.8 = container entPhysicalClass.9 = container entPhysicalClass.10 = container entPhysicalClass.11 = container entPhysicalClass.12 = container entPhysicalClass.13 = container entPhysicalClass.14 = container entPhysicalClass.15 = port entPhysicalClass.16 = port entPhysicalClass.17 = port entPhysicalClass.18 = port entPhysicalClass.19 = container entPhysicalClass.20 = container entPhysicalClass.21 = powerSupply entPhysicalClass.22 = container entPhysicalClass.23 = container entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 0 entPhysicalParentRelPos.3 = 0 entPhysicalParentRelPos.4 = 0 entPhysicalParentRelPos.5 = 0 entPhysicalParentRelPos.6 = 0 entPhysicalParentRelPos.7 = 1 entPhysicalParentRelPos.8 = 2 entPhysicalParentRelPos.9 = 3 entPhysicalParentRelPos.10 = 4 entPhysicalParentRelPos.11 = 5 entPhysicalParentRelPos.12 = 6 entPhysicalParentRelPos.13 = 1 entPhysicalParentRelPos.14 = 2 entPhysicalParentRelPos.15 = 0 entPhysicalParentRelPos.16 = 1 entPhysicalParentRelPos.17 = 2 entPhysicalParentRelPos.18 = 3 entPhysicalParentRelPos.19 = 3 entPhysicalParentRelPos.20 = 0 entPhysicalParentRelPos.21 = 0 entPhysicalParentRelPos.22 = 1 entPhysicalParentRelPos.23 = 0 entPhysicalName.1 = CISCO2911/K9 chassis entPhysicalName.2 = C2911 Chassis Slot 0 entPhysicalName.3 = C2911 Mother board 3GE, integrated VPN and 4W on Slot 0 entPhysicalName.4 = DaughterCard Slot 0 on Card 0 entPhysicalName.5 = Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu on Slot 0 SubSlot 0 entPhysicalName.6 = GigabitEthernet0/0/0 entPhysicalName.7 = DaughterCard Slot 1 on Card 0 entPhysicalName.8 = DaughterCard Slot 2 on Card 0 entPhysicalName.9 = DaughterCard Slot 3 on Card 0 entPhysicalName.10 = DaughterCard Slot 4 on Card 0 entPhysicalName.11 = DaughterCard Slot 5 on Card 0 entPhysicalName.12 = DaughterCard Slot 6 on Card 0 entPhysicalName.13 = C2911 Chassis Slot 1 entPhysicalName.14 = C2911 ISM Slot 0 entPhysicalName.15 = Embedded-Service-Engine0/0 entPhysicalName.16 = GigabitEthernet0/0 entPhysicalName.17 = GigabitEthernet0/1 entPhysicalName.18 = GigabitEthernet0/2 entPhysicalName.19 = Container of powerSupply Containers entPhysicalName.20 = Container of Power Supply entPhysicalName.21 = C2911 AC Power Supply entPhysicalName.22 = Container of RPS entPhysicalName.23 = EHWIC-1GE-SFP-CU SFP Container entPhysicalHardwareRev.1 = V07 entPhysicalHardwareRev.2 = entPhysicalHardwareRev.3 = V07 entPhysicalHardwareRev.4 = entPhysicalHardwareRev.5 = V01 entPhysicalHardwareRev.6 = entPhysicalHardwareRev.7 = entPhysicalHardwareRev.8 = entPhysicalHardwareRev.9 = entPhysicalHardwareRev.10 = entPhysicalHardwareRev.11 = entPhysicalHardwareRev.12 = entPhysicalHardwareRev.13 = entPhysicalHardwareRev.14 = entPhysicalHardwareRev.15 = entPhysicalHardwareRev.16 = entPhysicalHardwareRev.17 = entPhysicalHardwareRev.18 = entPhysicalHardwareRev.19 = entPhysicalHardwareRev.20 = entPhysicalHardwareRev.21 = V05 entPhysicalHardwareRev.22 = entPhysicalHardwareRev.23 = entPhysicalFirmwareRev.1 = System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1) entPhysicalFirmwareRev.2 = entPhysicalFirmwareRev.3 = entPhysicalFirmwareRev.4 = entPhysicalFirmwareRev.5 = entPhysicalFirmwareRev.6 = entPhysicalFirmwareRev.7 = entPhysicalFirmwareRev.8 = entPhysicalFirmwareRev.9 = entPhysicalFirmwareRev.10 = entPhysicalFirmwareRev.11 = entPhysicalFirmwareRev.12 = entPhysicalFirmwareRev.13 = entPhysicalFirmwareRev.14 = entPhysicalFirmwareRev.15 = entPhysicalFirmwareRev.16 = entPhysicalFirmwareRev.17 = entPhysicalFirmwareRev.18 = entPhysicalFirmwareRev.19 = entPhysicalFirmwareRev.20 = entPhysicalFirmwareRev.21 = entPhysicalFirmwareRev.22 = entPhysicalFirmwareRev.23 = entPhysicalSoftwareRev.1 = 15.1(4)M4, RELEASE SOFTWARE (fc1) entPhysicalSoftwareRev.2 = entPhysicalSoftwareRev.3 = 15.1(4)M4 entPhysicalSoftwareRev.4 = entPhysicalSoftwareRev.5 = entPhysicalSoftwareRev.6 = entPhysicalSoftwareRev.7 = entPhysicalSoftwareRev.8 = entPhysicalSoftwareRev.9 = entPhysicalSoftwareRev.10 = entPhysicalSoftwareRev.11 = entPhysicalSoftwareRev.12 = entPhysicalSoftwareRev.13 = entPhysicalSoftwareRev.14 = entPhysicalSoftwareRev.15 = entPhysicalSoftwareRev.16 = entPhysicalSoftwareRev.17 = entPhysicalSoftwareRev.18 = entPhysicalSoftwareRev.19 = entPhysicalSoftwareRev.20 = entPhysicalSoftwareRev.21 = entPhysicalSoftwareRev.22 = entPhysicalSoftwareRev.23 = entPhysicalSerialNum.1 = FCZ170461FN entPhysicalSerialNum.2 = entPhysicalSerialNum.3 = FOC165014WZ entPhysicalSerialNum.4 = entPhysicalSerialNum.5 = FOC153634LV entPhysicalSerialNum.6 = entPhysicalSerialNum.7 = entPhysicalSerialNum.8 = entPhysicalSerialNum.9 = entPhysicalSerialNum.10 = entPhysicalSerialNum.11 = entPhysicalSerialNum.12 = entPhysicalSerialNum.13 = entPhysicalSerialNum.14 = entPhysicalSerialNum.15 = entPhysicalSerialNum.16 = entPhysicalSerialNum.17 = entPhysicalSerialNum.18 = entPhysicalSerialNum.19 = entPhysicalSerialNum.20 = entPhysicalSerialNum.21 = DCA1636R05K entPhysicalSerialNum.22 = entPhysicalSerialNum.23 = entPhysicalMfgName.1 = Cisco entPhysicalMfgName.2 = Cisco entPhysicalMfgName.3 = Cisco entPhysicalMfgName.4 = Cisco entPhysicalMfgName.5 = Cisco entPhysicalMfgName.6 = Cisco entPhysicalMfgName.7 = Cisco entPhysicalMfgName.8 = Cisco entPhysicalMfgName.9 = Cisco entPhysicalMfgName.10 = Cisco entPhysicalMfgName.11 = Cisco entPhysicalMfgName.12 = Cisco entPhysicalMfgName.13 = Cisco entPhysicalMfgName.14 = Cisco entPhysicalMfgName.15 = Cisco entPhysicalMfgName.16 = Cisco entPhysicalMfgName.17 = Cisco entPhysicalMfgName.18 = Cisco entPhysicalMfgName.19 = Cisco entPhysicalMfgName.20 = Cisco entPhysicalMfgName.21 = Cisco entPhysicalMfgName.22 = Cisco entPhysicalMfgName.23 = Cisco entPhysicalModelName.1 = CISCO2911/K9 entPhysicalModelName.2 = entPhysicalModelName.3 = entPhysicalModelName.4 = entPhysicalModelName.5 = EHWIC-1GE-SFP-CU entPhysicalModelName.6 = entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.14 = entPhysicalModelName.15 = entPhysicalModelName.16 = entPhysicalModelName.17 = entPhysicalModelName.18 = entPhysicalModelName.19 = entPhysicalModelName.20 = entPhysicalModelName.21 = PWR-2911-AC entPhysicalModelName.22 = entPhysicalModelName.23 = entPhysicalAlias.1 = entPhysicalAlias.2 = entPhysicalAlias.3 = entPhysicalAlias.4 = entPhysicalAlias.5 = entPhysicalAlias.6 = entPhysicalAlias.7 = entPhysicalAlias.8 = entPhysicalAlias.9 = entPhysicalAlias.10 = entPhysicalAlias.11 = entPhysicalAlias.12 = entPhysicalAlias.13 = entPhysicalAlias.14 = entPhysicalAlias.15 = entPhysicalAlias.16 = entPhysicalAlias.17 = entPhysicalAlias.18 = entPhysicalAlias.19 = entPhysicalAlias.20 = entPhysicalAlias.21 = entPhysicalAlias.22 = entPhysicalAlias.23 = entPhysicalAssetID.1 = entPhysicalAssetID.2 = entPhysicalAssetID.3 = entPhysicalAssetID.4 = entPhysicalAssetID.5 = entPhysicalAssetID.6 = entPhysicalAssetID.7 = entPhysicalAssetID.8 = entPhysicalAssetID.9 = entPhysicalAssetID.10 = entPhysicalAssetID.11 = entPhysicalAssetID.12 = entPhysicalAssetID.13 = entPhysicalAssetID.14 = entPhysicalAssetID.15 = entPhysicalAssetID.16 = entPhysicalAssetID.17 = entPhysicalAssetID.18 = entPhysicalAssetID.19 = entPhysicalAssetID.20 = entPhysicalAssetID.21 = entPhysicalAssetID.22 = entPhysicalAssetID.23 = entPhysicalIsFRU.1 = false entPhysicalIsFRU.2 = false entPhysicalIsFRU.3 = false entPhysicalIsFRU.4 = false entPhysicalIsFRU.5 = true entPhysicalIsFRU.6 = false entPhysicalIsFRU.7 = false entPhysicalIsFRU.8 = false entPhysicalIsFRU.9 = false entPhysicalIsFRU.10 = false entPhysicalIsFRU.11 = false entPhysicalIsFRU.12 = false entPhysicalIsFRU.13 = false entPhysicalIsFRU.14 = false entPhysicalIsFRU.15 = false entPhysicalIsFRU.16 = false entPhysicalIsFRU.17 = false entPhysicalIsFRU.18 = false entPhysicalIsFRU.19 = false entPhysicalIsFRU.20 = false entPhysicalIsFRU.21 = true entPhysicalIsFRU.22 = false entPhysicalIsFRU.23 = false entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entAliasMappingIdentifier] entAliasMappingIdentifier.6.0 = ifIndex.1 entAliasMappingIdentifier.15.0 = ifIndex.2 entAliasMappingIdentifier.16.0 = ifIndex.3 entAliasMappingIdentifier.17.0 = ifIndex.4 entAliasMappingIdentifier.18.0 = ifIndex.5 SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '1'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='CISCO2911/K9 chassis',`entPhysicalClass` ='chassis',`entPhysicalName` ='CISCO2911/K9 chassis',`entPhysicalModelName` ='CISCO2911/K9',`entPhysicalSerialNum` ='FCZ170461FN',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='-1',`entPhysicalVendorType` ='cevChassisC2911',`entPhysicalHardwareRev` ='V07',`entPhysicalFirmwareRev` ='System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)',`entPhysicalSoftwareRev` ='15.1(4)M4, RELEASE SOFTWARE (fc1)',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='1'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '2'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='C2911 Chassis Slot',`entPhysicalClass` ='container',`entPhysicalName` ='C2911 Chassis Slot 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevContainerSlot',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='2'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '3'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='3',`entPhysicalDescr` ='C2911 Mother board 3GE, integrated VPN and 4W',`entPhysicalClass` ='module',`entPhysicalName` ='C2911 Mother board 3GE, integrated VPN and 4W on Slot 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='FOC165014WZ',`entPhysicalContainedIn` ='2',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevCpu29113ge',`entPhysicalHardwareRev` ='V07',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='15.1(4)M4',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='3'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '4'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='4',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 0 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='4'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '5'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='5',`entPhysicalDescr` ='Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu',`entPhysicalClass` ='module',`entPhysicalName` ='Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu on Slot 0 SubSlot 0',`entPhysicalModelName` ='EHWIC-1GE-SFP-CU',`entPhysicalSerialNum` ='FOC153634LV',`entPhysicalContainedIn` ='4',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevEHwic1GeSfpCu',`entPhysicalHardwareRev` ='V01',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='5'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '6'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='6',`entPhysicalDescr` ='EHWIC-1GE-SFP-CU',`entPhysicalClass` ='port',`entPhysicalName` ='GigabitEthernet0/0/0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='5',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevPortGEIP',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='6'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '7'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='7',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 1 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='7'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '8'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='8',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 2 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='8'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '9'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='9',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 3 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='9'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '10'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='10',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 4 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='10'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '11'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='11',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 5 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='5',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='11'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '12'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='12',`entPhysicalDescr` ='C2911 DaughterCard Slot',`entPhysicalClass` ='container',`entPhysicalName` ='DaughterCard Slot 6 on Card 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='6',`entPhysicalVendorType` ='cevContainerDaughterCard',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='12'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '13'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='13',`entPhysicalDescr` ='C2911 Chassis Slot',`entPhysicalClass` ='container',`entPhysicalName` ='C2911 Chassis Slot 1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='cevContainerSlot',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='13'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '14'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='14',`entPhysicalDescr` ='C2911 ISM Slot',`entPhysicalClass` ='container',`entPhysicalName` ='C2911 ISM Slot 0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='cevContainerSlot',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='14'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '15'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='15',`entPhysicalDescr` ='Embedded Service Engine',`entPhysicalClass` ='port',`entPhysicalName` ='Embedded-Service-Engine0/0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevPortSM',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='15'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '16'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='16',`entPhysicalDescr` ='CN Gigabit Ethernet',`entPhysicalClass` ='port',`entPhysicalName` ='GigabitEthernet0/0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='cevPortGEIP',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='16'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '17'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='17',`entPhysicalDescr` ='CN Gigabit Ethernet',`entPhysicalClass` ='port',`entPhysicalName` ='GigabitEthernet0/1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='cevPortGEIP',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='17'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '18'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='18',`entPhysicalDescr` ='CN Gigabit Ethernet',`entPhysicalClass` ='port',`entPhysicalName` ='GigabitEthernet0/2',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='3',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='cevPortGEIP',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='18'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '19'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='19',`entPhysicalDescr` ='Container of powerSupply Containers',`entPhysicalClass` ='container',`entPhysicalName` ='Container of powerSupply Containers',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='cevContainerPowerSupplyBay',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='19'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '20'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='20',`entPhysicalDescr` ='Container of Power Supply',`entPhysicalClass` ='container',`entPhysicalName` ='Container of Power Supply',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='19',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevContainerPowerSupply',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='20'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '21'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='21',`entPhysicalDescr` ='C2911 AC Power Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='C2911 AC Power Supply',`entPhysicalModelName` ='PWR-2911-AC',`entPhysicalSerialNum` ='DCA1636R05K',`entPhysicalContainedIn` ='20',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevPowerSupplyC2911PWRAC',`entPhysicalHardwareRev` ='V05',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='21'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '22'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='22',`entPhysicalDescr` ='Container of RPS',`entPhysicalClass` ='container',`entPhysicalName` ='Container of RPS',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='19',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='cevContainerPowerSupply',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='22'] .SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '29' AND entPhysicalIndex = '23'] SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='23',`entPhysicalDescr` ='EHWIC-1GE-SFP-CU SFP Container',`entPhysicalClass` ='container',`entPhysicalName` ='EHWIC-1GE-SFP-CU SFP Container',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='Cisco',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevContainerSFP',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='29' AND entPhysicalIndex='23'] . SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '29'] >> Runtime for discovery module 'entity-physical': 0.2570 seconds with 4848 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS Device #### Load disco module processors #### hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrDevice] hrDevice = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrProcessorLoad] hrProcessorLoad = No Such Object available on this agent at this OID CISCO-PROCESS-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-PROCESS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpmCPU] cpmCPUTotalPhysicalIndex.1 = 0 cpmCPUTotal5sec.1 = 4 cpmCPUTotal1min.1 = 9 cpmCPUTotal5min.1 = 13 cpmCPUTotal5secRev.1 = 4 cpmCPUTotal1minRev.1 = 9 cpmCPUTotal5minRev.1 = 13 cpmCPUMonInterval.1 = 5 cpmCPUTotalMonIntervalValue.1 = 4 cpmCPUInterruptMonIntervalValue.1 = 2 Array ( [1] => Array ( [cpmCPUTotalPhysicalIndex] => 0 [cpmCPUTotal5sec] => 4 [cpmCPUTotal1min] => 9 [cpmCPUTotal5min] => 13 [cpmCPUTotal5secRev] => 4 [cpmCPUTotal1minRev] => 9 [cpmCPUTotal5minRev] => 13 [cpmCPUMonInterval] => 5 [cpmCPUTotalMonIntervalValue] => 4 [cpmCPUInterruptMonIntervalValue] => 2 ) ) Discover Processor: .1.3.6.1.4.1.9.9.109.1.1.1.1.8.1, 1, cpm, Processor 1, 1, 13, 0, SQL[SELECT COUNT(processor_id) FROM `processors` WHERE `processor_index` = '1' AND `device_id` = '29' AND `processor_type` = 'cpm'] .SQL[UPDATE `processors` set `processor_descr` ='Processor 1',`processor_oid` ='.1.3.6.1.4.1.9.9.109.1.1.1.1.8.1',`processor_usage` ='13',`processor_precision` ='1' WHERE `device_id`='29' AND `processor_index`='1' AND `processor_type`='cpm'] SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '29' AND `processor_type` != 'ucd-old'] Array ( [cpm] => Array ( [1] => 1 ) ) SQL[SELECT * FROM `processors` WHERE `device_id` = '29'] 1 -> cpm >> Runtime for discovery module 'processors': 0.0820 seconds with 42896 bytes #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### CISCO-ENHANCED-MEMORY-POOL: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENHANCED-MEMPOOL-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cempMemPoolEntry] cempMemPoolType.1.1 = processorMemory cempMemPoolType.1.2 = ioMemory cempMemPoolName.1.1 = Processor cempMemPoolName.1.2 = I/O cempMemPoolPlatformMemory.1.1 = zeroDotZero cempMemPoolPlatformMemory.1.2 = zeroDotZero cempMemPoolAlternate.1.1 = 0 cempMemPoolAlternate.1.2 = 0 cempMemPoolValid.1.1 = true cempMemPoolValid.1.2 = true cempMemPoolUsed.1.1 = 31638744 cempMemPoolUsed.1.2 = 19253200 cempMemPoolFree.1.1 = 830991176 cempMemPoolFree.1.2 = 22689840 cempMemPoolLargestFree.1.1 = 519771016 cempMemPoolLargestFree.1.2 = 20115324 cempMemPoolLowestFree.1.1 = 586607164 cempMemPoolLowestFree.1.2 = 22656240 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName.1] CISCO2911/K9 chassis Discover Mempool: 1.1, cemp, CISCO2911/K9 chassis - Processor, 1, 1, SQL[SELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '1.1' AND `device_id` = '29' AND `mempool_type` = 'cemp'] .SQL[UPDATE `mempools` set `mempool_descr` ='CISCO2911/K9 chassis - Processor',`entPhysicalIndex` ='1' WHERE device_id='29' AND mempool_index='1.1' AND mempool_type='cemp'] SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName.1] CISCO2911/K9 chassis Discover Mempool: 1.2, cemp, CISCO2911/K9 chassis - I/O, 1, 1, SQL[SELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '1.2' AND `device_id` = '29' AND `mempool_type` = 'cemp'] .SQL[UPDATE `mempools` set `mempool_descr` ='CISCO2911/K9 chassis - I/O',`entPhysicalIndex` ='1' WHERE device_id='29' AND mempool_index='1.2' AND mempool_type='cemp'] SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '29' AND `mempool_type` = 'cemp'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal] hpLocalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal] hpGlobalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID Array ( [cemp] => Array ( [1.1] => 1 [1.2] => 1 ) ) SQL[SELECT * FROM `mempools` WHERE `device_id` = '29'] 1.1 -> cemp 1.2 -> cemp >> Runtime for discovery module 'mempools': 0.1670 seconds with 24400 bytes #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1512 bytes #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS+ Device #### Load disco module cisco-mac-accounting #### SQL[SELECT * FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = ''] SQL[SELECT * FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = ''] >> Runtime for discovery module 'cisco-mac-accounting': 0.0260 seconds with 1488 bytes #### Unload disco module cisco-mac-accounting #### Modules status: Global- OS+ Device #### Load disco module cisco-pw #### SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '29'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcID] cpwVcID = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcName] cpwVcName = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcType] cpwVcType = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcPsnType] cpwVcPsnType = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcDescr] cpwVcDescr = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-WAN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcWANPeerLdpID] cpwVcWANPeerLdpID = No Such Instance currently exists at this OID >> Runtime for discovery module 'cisco-pw': 0.1770 seconds with 1464 bytes #### Unload disco module cisco-pw #### Modules status: Global- OS+ Device #### Load disco module cisco-vrf #### >> Runtime for discovery module 'cisco-vrf': 0.0000 seconds with 1984 bytes #### Unload disco module cisco-vrf #### Modules status: Global+ OS+ Device #### Load disco module cisco-cef #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 CISCO-CEF-MIB::cefSwitchingPath] cefSwitchingPath = No Such Instance currently exists at this OID cefSwitchingPath = No Such Instance currently exists at this OID || cefSwitchingPath || || || Array ( ) Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalDescr] entPhysicalDescr.1 = CISCO2911/K9 chassis entPhysicalDescr.2 = C2911 Chassis Slot entPhysicalDescr.3 = C2911 Mother board 3GE, integrated VPN and 4W entPhysicalDescr.4 = C2911 DaughterCard Slot entPhysicalDescr.5 = Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu entPhysicalDescr.6 = EHWIC-1GE-SFP-CU entPhysicalDescr.7 = C2911 DaughterCard Slot entPhysicalDescr.8 = C2911 DaughterCard Slot entPhysicalDescr.9 = C2911 DaughterCard Slot entPhysicalDescr.10 = C2911 DaughterCard Slot entPhysicalDescr.11 = C2911 DaughterCard Slot entPhysicalDescr.12 = C2911 DaughterCard Slot entPhysicalDescr.13 = C2911 Chassis Slot entPhysicalDescr.14 = C2911 ISM Slot entPhysicalDescr.15 = Embedded Service Engine entPhysicalDescr.16 = CN Gigabit Ethernet entPhysicalDescr.17 = CN Gigabit Ethernet entPhysicalDescr.18 = CN Gigabit Ethernet entPhysicalDescr.19 = Container of powerSupply Containers entPhysicalDescr.20 = Container of Power Supply entPhysicalDescr.21 = C2911 AC Power Supply entPhysicalDescr.22 = Container of RPS entPhysicalDescr.23 = EHWIC-1GE-SFP-CU SFP Container entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName] entPhysicalName.1 = CISCO2911/K9 chassis entPhysicalName.2 = C2911 Chassis Slot 0 entPhysicalName.3 = C2911 Mother board 3GE, integrated VPN and 4W on Slot 0 entPhysicalName.4 = DaughterCard Slot 0 on Card 0 entPhysicalName.5 = Enhanced High Speed WAN Interface Card-1 Port Gigabit Ethernet SFP/Cu on Slot 0 SubSlot 0 entPhysicalName.6 = GigabitEthernet0/0/0 entPhysicalName.7 = DaughterCard Slot 1 on Card 0 entPhysicalName.8 = DaughterCard Slot 2 on Card 0 entPhysicalName.9 = DaughterCard Slot 3 on Card 0 entPhysicalName.10 = DaughterCard Slot 4 on Card 0 entPhysicalName.11 = DaughterCard Slot 5 on Card 0 entPhysicalName.12 = DaughterCard Slot 6 on Card 0 entPhysicalName.13 = C2911 Chassis Slot 1 entPhysicalName.14 = C2911 ISM Slot 0 entPhysicalName.15 = Embedded-Service-Engine0/0 entPhysicalName.16 = GigabitEthernet0/0 entPhysicalName.17 = GigabitEthernet0/1 entPhysicalName.18 = GigabitEthernet0/2 entPhysicalName.19 = Container of powerSupply Containers entPhysicalName.20 = Container of Power Supply entPhysicalName.21 = C2911 AC Power Supply entPhysicalName.22 = Container of RPS entPhysicalName.23 = EHWIC-1GE-SFP-CU SFP Container entPhysicalModelNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalModelName] entPhysicalModelName.1 = CISCO2911/K9 entPhysicalModelName.2 = entPhysicalModelName.3 = entPhysicalModelName.4 = entPhysicalModelName.5 = EHWIC-1GE-SFP-CU entPhysicalModelName.6 = entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.14 = entPhysicalModelName.15 = entPhysicalModelName.16 = entPhysicalModelName.17 = entPhysicalModelName.18 = entPhysicalModelName.19 = entPhysicalModelName.20 = entPhysicalModelName.21 = PWR-2911-AC entPhysicalModelName.22 = entPhysicalModelName.23 = >> Runtime for discovery module 'cisco-cef': 0.1120 seconds with 37256 bytes #### Unload disco module cisco-cef #### Modules status: Global- OS+ Device #### Load disco module cisco-sla #### >> Runtime for discovery module 'cisco-sla': 0.0000 seconds with 1728 bytes #### Unload disco module cisco-sla #### Modules status: Global- OS Device+ #### Load disco module cisco-cbqos #### SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' AND `type` = 'Cisco-CBQOS' )] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.166.1.1] .*.*.*.1.2.66 1 .*.*.*.1.3.66 2 .*.*.*.1.4.66 4 .*.*.*.1.5.66 0 .*.*.*.1.6.66 0 .*.*.*.1.7.66 0 .*.*.*.1.8.66 0 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.166.1.5] .*.*.*.* 3764816 .*.*.*.*7235 12703891 .*.*.*.*7667 11855043 .*.*.*.*01409 1593 .*.*.*.*75154 1594 .*.*.*.*38688 540576 .*.*.*.*54049 9345761 .*.*.*.*34130 2314978 .*.*.*.*19458 1594 .*.*.*.*68371 4561555 .*.*.*.*79425 7128993 .*.*.*.*49362 1144146 .*.*.*.*30400 6390512 .*.*.*.*57313 1593 .*.*.*.*53139 13146627 .*.*.*.*03922 9595314 .*.*.*.*62545 4603569 .*.*.*.*47394 1594 .*.*.*.*82481 1593 .*.*.*.*45411 5715027 .*.*.*.*09907 4709971 .*.*.*.* 1 .*.*.*.*7235 6 .*.*.*.*7667 6 .*.*.*.*01409 2 .*.*.*.*75154 3 .*.*.*.*38688 1 .*.*.*.*54049 2 .*.*.*.*34130 3 .*.*.*.*19458 3 .*.*.*.*68371 6 .*.*.*.*79425 2 .*.*.*.*49362 3 .*.*.*.*30400 1 .*.*.*.*57313 2 .*.*.*.*53139 4 .*.*.*.*03922 3 .*.*.*.*62545 2 .*.*.*.*47394 3 .*.*.*.*82481 2 .*.*.*.*45411 4 .*.*.*.*09907 4 .*.*.*.* 0 .*.*.*.*7235 12257313 .*.*.*.*7667 15082481 .*.*.*.*01409 12030400 .*.*.*.*75154 4501409 .*.*.*.*38688 15082481 .*.*.*.*54049 12030400 .*.*.*.*34130 5854049 .*.*.*.*19458 15082481 .*.*.*.*68371 10779425 .*.*.*.*79425 5638688 .*.*.*.*49362 10779425 .*.*.*.*30400 12257313 .*.*.*.*57313 5638688 .*.*.*.*53139 5854049 .*.*.*.*03922 14162545 .*.*.*.*62545 12030400 .*.*.*.*47394 12257313 .*.*.*.*82481 66 .*.*.*.*45411 14162545 .*.*.*.*09907 4501409 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.166.1.6] .*.*.*.1.1.540576 "Egress_Link_Separation" .*.*.*.1.1.3764816 "Shape_WAN" .*.*.*.1.1.6390512 "WEP_Flow_Separation" .*.*.*.1.2.540576 "" .*.*.*.1.2.3764816 "" .*.*.*.1.2.6390512 "" SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.166.1.7] .*.*.*.1.1.1593 "class-default" .*.*.*.1.1.4603569 "map_Tesla_WEP_4MB" .*.*.*.1.1.7128993 "map_Tesla_Water" .*.*.*.1.1.9345761 "map_Tesla_WEP_12MB" .*.*.*.1.2.1593 "" .*.*.*.1.2.4603569 "" .*.*.*.1.2.7128993 "" .*.*.*.1.2.9345761 "" .*.*.*.1.3.1593 3 .*.*.*.1.3.4603569 3 .*.*.*.1.3.7128993 3 .*.*.*.1.3.9345761 3 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.166.1.8] .*.*.*.1.1.1594 "Match any " .*.*.*.1.1.1144146 "Match access-group name Tesla_Water" .*.*.*.1.1.2314978 "Match access-group name Tesla_WEP_12MB" .*.*.*.1.1.9595314 "Match access-group name Tesla_WEP_4MB" .*.*.*.1.2.1594 1 .*.*.*.1.2.1144146 1 .*.*.*.1.2.2314978 1 .*.*.*.1.2.9595314 1 QoS Objects Found: Index: 3764816 UID: 25d05e7f SPID.SPOBJ: 66.66 If-Index: 4 Type: 1 - Policy-Map Label: Shape_WAN Index: 1593 UID: 05baf6be SPID.SPOBJ: 66.4501409 If-Index: 4 Type: 2 - Class-Map Label: class-default Match: Match-Any: Match any Index: 540576 UID: 5d6871af SPID.SPOBJ: 66.5638688 If-Index: 4 Type: 1 - Policy-Map Label: Egress_Link_Separation Index: 9345761 UID: 45204ed4 SPID.SPOBJ: 66.5854049 If-Index: 4 Type: 2 - Class-Map Label: map_Tesla_WEP_12MB Match: Match-Any: Match access-group name Tesla_WEP_12MB Index: 7128993 UID: a787a317 SPID.SPOBJ: 66.10779425 If-Index: 4 Type: 2 - Class-Map Label: map_Tesla_Water Match: Match-Any: Match access-group name Tesla_Water Index: 6390512 UID: b701917a SPID.SPOBJ: 66.12030400 If-Index: 4 Type: 1 - Policy-Map Label: WEP_Flow_Separation Index: 1593 UID: 2509fc38 SPID.SPOBJ: 66.12257313 If-Index: 4 Type: 2 - Class-Map Label: class-default Match: Match-Any: Match any Index: 4603569 UID: 8c4b5140 SPID.SPOBJ: 66.14162545 If-Index: 4 Type: 2 - Class-Map Label: map_Tesla_WEP_4MB Match: Match-Any: Match access-group name Tesla_WEP_4MB Index: 1593 UID: dadd993a SPID.SPOBJ: 66.15082481 If-Index: 4 Type: 2 - Class-Map Label: class-default Match: Match-Any: Match any .........SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' )] >> Runtime for discovery module 'Cisco-CBQOS': 0.1190 seconds with 78904 bytes #### Unload disco module Cisco-CBQOS #### Modules status: Global- OS+ Device #### Load disco module cisco-otv #### SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' AND `type` = 'Cisco-OTV' )] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.2.1.1] .*.*.8*.1 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.3.1.1] .*.*.8*.1 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.3.1.1.4] .*.*.8*.1.4 No Such Object available on this agent at this OID SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' )] >> Runtime for discovery module 'Cisco-OTV': 0.1480 seconds with -3144 bytes #### Unload disco module Cisco-OTV #### Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntIfIndex] ipAdEntIfIndex.* 8 ipAdEntIfIndex.* 4 ipAdEntIfIndex.* 1 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.8.8.200.127] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '29' AND `ifIndex` = '8'] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = '8'] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '8.8.200.127/32'] SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '8.8.200.127/32'] sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '8.8.200.127/32'] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '8.8.200.127' AND `ipv4_prefixlen` = '32' AND `port_id` = '3909' ] SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '8.8.200.127' AND `ipv4_prefixlen` = '32' AND `port_id` = '3909'] .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.173.168.2.5] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '29' AND `ifIndex` = '4'] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = '4'] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '173.168.2.0/24'] SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '173.168.2.0/24'] sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '173.168.2.0/24'] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '173.168.2.5' AND `ipv4_prefixlen` = '24' AND `port_id` = '3901' ] SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '173.168.2.5' AND `ipv4_prefixlen` = '24' AND `port_id` = '3901'] .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.3.3.3.1] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '29' AND `ifIndex` = '1'] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = '1'] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '3.3.3.0/30'] SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '3.3.3.0/30'] sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '3.3.3.0/30'] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '3.3.3.1' AND `ipv4_prefixlen` = '30' AND `port_id` = '3894' ] SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '3.3.3.1' AND `ipv4_prefixlen` = '30' AND `port_id` = '3894'] .SQL[SELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '29' AND A.port_id = I.port_id] >> Runtime for discovery module 'ipv4-addresses': 0.1080 seconds with 21160 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAddressIfIndex.ipv6] ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipv6AddrPfxLength] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[SELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '29' AND A.port_id = I.port_id] >> Runtime for discovery module 'ipv6-addresses': 0.0530 seconds with 984 bytes #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### Pre-cache: CISCO-ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entSensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorType] entSensorType = No Such Instance currently exists at this OID entSensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorScale] entSensorScale = No Such Instance currently exists at this OID entSensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorValue] entSensorValue = No Such Instance currently exists at this OID entSensorMeasuredEntitySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorMeasuredEntity] entSensorMeasuredEntity = No Such Object available on this agent at this OID entSensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorPrecision] entSensorPrecision = No Such Instance currently exists at this OID entSensorThresholdSeveritySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdSeverity] entSensorThresholdSeverity = No Such Instance currently exists at this OID entSensorThresholdRelationSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdRelation] entSensorThresholdRelation = No Such Instance currently exists at this OID entSensorThresholdValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdValue] entSensorThresholdValue = No Such Instance currently exists at this OID Array ( ) ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorType] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorScale] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorPrecision] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorValue] entPhySensorValue = No Such Object available on this agent at this OID SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '29' AND `attrib_type` = 'ipmi_hostname' ] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'ipmi'] Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Fanspeeds: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeeds' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Frequencies: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequencies' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] States: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonVoltageStatusTable] ciscoEnvMonVoltageStatusDescr.1 = 12V voltage in mV ciscoEnvMonVoltageStatusDescr.2 = 5V voltage in mV ciscoEnvMonVoltageStatusDescr.3 = 3.3V voltage in mV ciscoEnvMonVoltageStatusDescr.4 = 2.5V voltage in mV ciscoEnvMonVoltageStatusDescr.5 = 1.8V voltage in mV ciscoEnvMonVoltageStatusDescr.6 = 1.2V voltage in mV ciscoEnvMonVoltageStatusDescr.7 = ASIC voltage in mV ciscoEnvMonVoltageStatusDescr.8 = CPU Core voltage in mV ciscoEnvMonVoltageStatusValue.1 = 12656 ciscoEnvMonVoltageStatusValue.2 = 5173 ciscoEnvMonVoltageStatusValue.3 = 3310 ciscoEnvMonVoltageStatusValue.4 = 2499 ciscoEnvMonVoltageStatusValue.5 = 1824 ciscoEnvMonVoltageStatusValue.6 = 1197 ciscoEnvMonVoltageStatusValue.7 = 1046 ciscoEnvMonVoltageStatusValue.8 = 1099 ciscoEnvMonVoltageThresholdLow.1 = 8990 ciscoEnvMonVoltageThresholdLow.2 = 4370 ciscoEnvMonVoltageThresholdLow.3 = 2800 ciscoEnvMonVoltageThresholdLow.4 = 2120 ciscoEnvMonVoltageThresholdLow.5 = 1530 ciscoEnvMonVoltageThresholdLow.6 = 1020 ciscoEnvMonVoltageThresholdLow.7 = 850 ciscoEnvMonVoltageThresholdLow.8 = 890 ciscoEnvMonVoltageThresholdHigh.1 = 13970 ciscoEnvMonVoltageThresholdHigh.2 = 5920 ciscoEnvMonVoltageThresholdHigh.3 = 3790 ciscoEnvMonVoltageThresholdHigh.4 = 2870 ciscoEnvMonVoltageThresholdHigh.5 = 2070 ciscoEnvMonVoltageThresholdHigh.6 = 1380 ciscoEnvMonVoltageThresholdHigh.7 = 1210 ciscoEnvMonVoltageThresholdHigh.8 = 1380 ciscoEnvMonVoltageLastShutdown.1 = 12640 ciscoEnvMonVoltageLastShutdown.2 = 5180 ciscoEnvMonVoltageLastShutdown.3 = 3314 ciscoEnvMonVoltageLastShutdown.4 = 2496 ciscoEnvMonVoltageLastShutdown.5 = 1822 ciscoEnvMonVoltageLastShutdown.6 = 1199 ciscoEnvMonVoltageLastShutdown.7 = 1044 ciscoEnvMonVoltageLastShutdown.8 = 1094 ciscoEnvMonVoltageState.1 = normal ciscoEnvMonVoltageState.2 = normal ciscoEnvMonVoltageState.3 = normal ciscoEnvMonVoltageState.4 = normal ciscoEnvMonVoltageState.5 = normal ciscoEnvMonVoltageState.6 = normal ciscoEnvMonVoltageState.7 = normal ciscoEnvMonVoltageState.8 = normal SQL[SELECT * FROM state_indexes WHERE state_name = 'ciscoEnvMonVoltageState'] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.1, 1, ciscoEnvMonVoltageState, 12V Voltage In MV, snmp, , 1 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '1'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '1'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '1'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('81','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.2, 2, ciscoEnvMonVoltageState, 5V Voltage In MV, snmp, , 2 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '2'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '2'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '2'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('82','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.3, 3, ciscoEnvMonVoltageState, 3.3V Voltage In MV, snmp, , 3 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '3'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '3'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '3'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('83','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.4, 4, ciscoEnvMonVoltageState, 2.5V Voltage In MV, snmp, , 4 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '4'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '4'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '4'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('84','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.5, 5, ciscoEnvMonVoltageState, 1.8V Voltage In MV, snmp, , 5 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '5'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '5'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '5'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('85','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.6, 6, ciscoEnvMonVoltageState, 1.2V Voltage In MV, snmp, , 6 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '6'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '6'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '6'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('86','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.7, 7, ciscoEnvMonVoltageState, ASIC Voltage In MV, snmp, , 7 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '7'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '7'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '7'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('87','2')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.2.1.7.8, 8, ciscoEnvMonVoltageState, CPU Core Voltage In MV, snmp, , 8 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonVoltageState' AND `sensor_index` = '8'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '8'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonVoltageState' AND `sensor_index` = '8'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonVoltageState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('88','2')] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonTemperatureStatusTable] ciscoEnvMonTemperatureStatusDescr.1 = CPU ciscoEnvMonTemperatureStatusDescr.2 = Intake Left(Bezel) ciscoEnvMonTemperatureStatusDescr.3 = Intake Left ciscoEnvMonTemperatureStatusDescr.4 = Exhaust Right(Bezel) ciscoEnvMonTemperatureStatusDescr.5 = Exhaust Right ciscoEnvMonTemperatureStatusDescr.6 = Power Supply ciscoEnvMonTemperatureStatusValue.1 = 51 ciscoEnvMonTemperatureStatusValue.2 = 22 ciscoEnvMonTemperatureStatusValue.3 = 23 ciscoEnvMonTemperatureStatusValue.4 = 27 ciscoEnvMonTemperatureStatusValue.5 = 24 ciscoEnvMonTemperatureStatusValue.6 = 25 ciscoEnvMonTemperatureThreshold.1 = 120 ciscoEnvMonTemperatureThreshold.2 = 57 ciscoEnvMonTemperatureThreshold.3 = 57 ciscoEnvMonTemperatureThreshold.4 = 75 ciscoEnvMonTemperatureThreshold.5 = 75 ciscoEnvMonTemperatureThreshold.6 = 70 ciscoEnvMonTemperatureLastShutdown.1 = 0 ciscoEnvMonTemperatureLastShutdown.2 = 0 ciscoEnvMonTemperatureLastShutdown.3 = 0 ciscoEnvMonTemperatureLastShutdown.4 = 0 ciscoEnvMonTemperatureLastShutdown.5 = 0 ciscoEnvMonTemperatureLastShutdown.6 = 0 ciscoEnvMonTemperatureState.1 = normal ciscoEnvMonTemperatureState.2 = normal ciscoEnvMonTemperatureState.3 = normal ciscoEnvMonTemperatureState.4 = normal ciscoEnvMonTemperatureState.5 = normal ciscoEnvMonTemperatureState.6 = normal SQL[SELECT * FROM state_indexes WHERE state_name = 'ciscoEnvMonTemperatureState'] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.1, 1, ciscoEnvMonTemperatureState, CPU, snmp, , 1 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '1'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '1'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '1'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('89','3')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.2, 2, ciscoEnvMonTemperatureState, Intake Left(Bezel), snmp, , 2 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '2'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '2'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '2'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('90','3')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.3, 3, ciscoEnvMonTemperatureState, Intake Left, snmp, , 3 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '3'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '3'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '3'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('91','3')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.4, 4, ciscoEnvMonTemperatureState, Exhaust Right(Bezel), snmp, , 4 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '4'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '4'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '4'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('92','3')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.5, 5, ciscoEnvMonTemperatureState, Exhaust Right, snmp, , 5 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '5'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '5'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '5'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('93','3')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.6.6, 6, ciscoEnvMonTemperatureState, Power Supply, snmp, , 6 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '6'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '6'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonTemperatureState' AND `sensor_index` = '6'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonTemperatureState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('94','3')] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonFanStatusTable] ciscoEnvMonFanStatusDescr.1 = Fan Tray ciscoEnvMonFanStatusDescr.2 = Fan 1 ciscoEnvMonFanStatusDescr.3 = Fan 2 ciscoEnvMonFanStatusDescr.4 = Fan 3 ciscoEnvMonFanStatusDescr.5 = Fan 4 ciscoEnvMonFanState.1 = normal ciscoEnvMonFanState.2 = normal ciscoEnvMonFanState.3 = normal ciscoEnvMonFanState.4 = normal ciscoEnvMonFanState.5 = normal SQL[SELECT * FROM state_indexes WHERE state_name = 'ciscoEnvMonFanState'] Discover sensor: .1.3.6.1.4.1.9.9.13.1.4.1.3.1, 1, ciscoEnvMonFanState, Fan Tray, snmp, , 1 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonFanState' AND `sensor_index` = '1'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '1'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '1'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonFanState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('95','4')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.4.1.3.2, 2, ciscoEnvMonFanState, Fan 1, snmp, , 2 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonFanState' AND `sensor_index` = '2'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '2'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '2'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonFanState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('96','4')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.4.1.3.3, 3, ciscoEnvMonFanState, Fan 2, snmp, , 3 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonFanState' AND `sensor_index` = '3'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '3'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '3'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonFanState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('97','4')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.4.1.3.4, 4, ciscoEnvMonFanState, Fan 3, snmp, , 4 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonFanState' AND `sensor_index` = '4'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '4'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '4'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonFanState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('98','4')] Discover sensor: .1.3.6.1.4.1.9.9.13.1.4.1.3.5, 5, ciscoEnvMonFanState, Fan 4, snmp, , 5 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonFanState' AND `sensor_index` = '5'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '5'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonFanState' AND `sensor_index` = '5'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonFanState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('99','4')] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonSupplyStatusTable] ciscoEnvMonSupplyStatusDescr.1 = C2911 AC Power Supply ciscoEnvMonSupplyState.1 = normal ciscoEnvMonSupplySource.1 = ac SQL[SELECT * FROM state_indexes WHERE state_name = 'ciscoEnvMonSupplyState'] Discover sensor: .1.3.6.1.4.1.9.9.13.1.5.1.3.1, 1, ciscoEnvMonSupplyState, C2911 AC Power Supply, snmp, , 1 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '29' AND sensor_type = 'ciscoEnvMonSupplyState' AND `sensor_index` = '1'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonSupplyState' AND `sensor_index` = '1'] .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '29' AND `sensor_type` = 'ciscoEnvMonSupplyState' AND `sensor_index` = '1'] SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'ciscoEnvMonSupplyState'] SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('100','5')] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswGlobals] cswGlobals = No Such Object available on this agent at this OID SQL[SELECT * FROM state_indexes WHERE state_name = 'cswRingRedundant'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswSwitchRole] cswSwitchRole = No Such Object available on this agent at this OID SQL[SELECT * FROM state_indexes WHERE state_name = 'cswSwitchRole'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswSwitchState] cswSwitchState = No Such Object available on this agent at this OID SQL[SELECT * FROM state_indexes WHERE state_name = 'cswSwitchState'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswStackPortOperStatus] cswStackPortOperStatus = No Such Object available on this agent at this OID SQL[SELECT * FROM state_indexes WHERE state_name = 'cswStackPortOperStatus'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-RF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cRFCfgRedundancyOperMode] cRFCfgRedundancyOperMode.0 = nonRedundant SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='states' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Temperatures: Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.1, 1, cisco, CPU, snmp, , 1 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '1'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '1'] .Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.2, 2, cisco, Intake Left(Bezel), snmp, , 2 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '2'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '2'] .Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.3, 3, cisco, Intake Left, snmp, , 3 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '3'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '3'] .Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.4, 4, cisco, Exhaust Right(Bezel), snmp, , 4 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '4'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '4'] .Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.5, 5, cisco, Exhaust Right, snmp, , 5 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '5'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '5'] .Discover sensor: .1.3.6.1.4.1.9.9.13.1.3.1.3.6, 6, cisco, Power Supply, snmp, , 6 SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '29' AND sensor_type = 'cisco' AND `sensor_index` = '6'] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '29' AND `sensor_type` = 'cisco' AND `sensor_index` = '6'] .SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperatures' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] Voltages: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltages' AND S.device_id = D.device_id AND D.device_id = '29' AND S.poller_type = 'snmp'] >> Runtime for discovery module 'sensors': 0.6160 seconds with 32480 bytes #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dfEntry] dfEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dskTable] dskTable = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '29' AND `storage_type` != 'dsk'] SQL[SELECT * FROM `storage` WHERE `device_id` = '29'] >> Runtime for discovery module 'storage': 0.1800 seconds with 2600 bytes #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrDeviceEntry] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrProcessorEntry] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '29'] >> Runtime for discovery module 'hr-device': 0.0500 seconds with 792 bytes #### Unload disco module hr-device #### Modules status: Global- OS Device Module [ discovery-protocols ] disabled globally. Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipNetToPhysicalPhysAddress] ipNetToPhysicalPhysAddress.1.ipv4."*" = f8:c0:1:92:97:f8 ipNetToPhysicalPhysAddress.1.ipv4."*" = 44:3:a7:a6:34:53 ipNetToPhysicalPhysAddress.4.ipv4."*" = 4c:4e:35:82:11:81 ipNetToPhysicalPhysAddress.4.ipv4."*" = 0:6:f6:b5:29:81 ipNetToPhysicalPhysAddress.4.ipv4."*" = 0:6:f6:a3:0:b1 ipNetToPhysicalPhysAddress.4.ipv4."*" = 0:6:f6:f2:1d:a1 ipNetToPhysicalPhysAddress.4.ipv4."*" = 44:3:a7:a6:34:51 ipNetToPhysicalPhysAddress.4.ipv4."*" = d0:72:dc:a5:15:a0 ipNetToPhysicalPhysAddress.4.ipv4."*" = 44:3:a7:d0:ad:89 ipNetToPhysicalPhysAddress.4.ipv4."*" = ac:f2:c5:d2:a7:89 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipNetToMediaPhysAddress] ipNetToMediaPhysAddress.*.253 = f8:c0:1:92:97:f8 ipNetToMediaPhysAddress.*.254 = 44:3:a7:a6:34:53 ipNetToMediaPhysAddress.*.1 = 4c:4e:35:82:11:81 ipNetToMediaPhysAddress.*.2 = 0:6:f6:b5:29:81 ipNetToMediaPhysAddress.*.3 = 0:6:f6:a3:0:b1 ipNetToMediaPhysAddress.*.4 = 0:6:f6:f2:1d:a1 ipNetToMediaPhysAddress.*.5 = 44:3:a7:a6:34:51 ipNetToMediaPhysAddress.*.6 = d0:72:dc:a5:15:a0 ipNetToMediaPhysAddress.*.7 = 44:3:a7:d0:ad:89 ipNetToMediaPhysAddress.*.8 = ac:f2:c5:d2:a7:89 SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='29' AND M.context_name=''] SQL[SELECT * FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = '1'] SQL[SELECT * FROM `ports` WHERE `device_id` = '29' AND `ifIndex` = '4'] >> Runtime for discovery module 'arp-table': 0.0620 seconds with 42496 bytes #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.2.1.15.2] 65099 AS65099 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oq -m CISCO-BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cbgpPeer2RemoteAs] CISCO-BGP4-MIB::cbgpPeer2RemoteAs No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oq -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 BGP4-MIB::bgpPeerRemoteAs] BGP4-MIB::bgpPeerRemoteAs.* 16637 Peers : BGP4-MIB::bgpPeerRemoteAs.3.3.3.3 16637 Found peer 3.3.3.3 (AS16637) SQL[SELECT COUNT(*) from `bgpPeers` WHERE device_id = '29' AND bgpPeerIdentifier = '3.3.3.3'] SQL[UPDATE `bgpPeers` set `bgpPeerRemoteAs` ='16637',`astext` ='' WHERE device_id='29' AND bgpPeerIdentifier='3.3.3.3'] .SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cbgpPeerAddrFamilyEntry] cbgpPeerAddrFamilyName.*.ipv4.unicast = IPv4 Unicast afi data :: Array ( [3.3.3.3.ipv4.unicast] => Array ( [cbgpPeerAddrFamilyName] => IPv4 Unicast ) ) AFISAFI = 3.3.3.3.ipv4.unicast SQL[SELECT COUNT(*) from `bgpPeers_cbgp` WHERE device_id = '29' AND bgpPeerIdentifier = '3.3.3.3' AND afi='ipv4' AND safi='unicast'] SQL[SELECT * FROM bgpPeers_cbgp WHERE `device_id` = '29' AND bgpPeerIdentifier = '3.3.3.3'] SQL[SELECT * FROM bgpPeers WHERE device_id = '29' AND (context_name = '' OR context_name IS NULL)] FIN BGP >> Runtime for discovery module 'bgp-peers': 0.0810 seconds with 11192 bytes #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = '29'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dBasePortIfIndex] dot1dBasePortIfIndex = No Such Instance currently exists at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qVlanVersionNumber.0] version1 ver version1 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qVlanStaticName] dot1qVlanStaticName = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qVlanCurrentEgressPorts] dot1qVlanCurrentEgressPorts = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qVlanCurrentUntaggedPorts] dot1qVlanCurrentUntaggedPorts = No Such Instance currently exists at this OID Cisco VLANs: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vlanTrunkPortNativeVlan] vlanTrunkPortNativeVlan = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VLAN-MEMBERSHIP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vmVlan] vmVlan = No Such Instance currently exists at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OnvQ -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vtpVersion.0] two SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vlanManagementDomains] managementDomainName.1 = managementDomainLocalMode.1 = server managementDomainConfigRevNumber.1 = 0 managementDomainLastUpdater.1 = * managementDomainLastChange.1 = 12336-48-48,48:48:48.48,048:4848 managementDomainRowStatus.1 = active managementDomainTftpServer.1 = * managementDomainTftpPathname.1 = managementDomainPruningState.1 = disabled managementDomainVersionInUse.1 = version1 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vtpVlanEntry] vtpVlanState.1.1 = operational vtpVlanState.1.1002 = operational vtpVlanState.1.1003 = operational vtpVlanState.1.1004 = operational vtpVlanState.1.1005 = operational vtpVlanType.1.1 = ethernet vtpVlanType.1.1002 = fddi vtpVlanType.1.1003 = tokenRing vtpVlanType.1.1004 = fddiNet vtpVlanType.1.1005 = trNet vtpVlanName.1.1 = default vtpVlanName.1.1002 = fddi-default vtpVlanName.1.1003 = token-ring-default vtpVlanName.1.1004 = fddinet-default vtpVlanName.1.1005 = trnet-default vtpVlanMtu.1.1 = 1500 vtpVlanMtu.1.1002 = 1500 vtpVlanMtu.1.1003 = 1500 vtpVlanMtu.1.1004 = 1500 vtpVlanMtu.1.1005 = 1500 vtpVlanDot10Said.1.1 = "00 01 86 A1 " vtpVlanDot10Said.1.1002 = "00 01 8A 8A " vtpVlanDot10Said.1.1003 = "00 01 8A 8B " vtpVlanDot10Said.1.1004 = "00 01 8A 8C " vtpVlanDot10Said.1.1005 = "00 01 8A 8D " vtpVlanRingNumber.1.1003 = 0 vtpVlanBridgeNumber.1.1004 = 1 vtpVlanBridgeNumber.1.1005 = 1 vtpVlanStpType.1.1004 = ibm vtpVlanStpType.1.1005 = ibm vtpVlanParentVlan.1.1003 = 1005 vtpVlanTranslationalVlan1.1.1 = 1002 vtpVlanTranslationalVlan1.1.1002 = 1 vtpVlanTranslationalVlan1.1.1003 = 1 vtpVlanTranslationalVlan1.1.1004 = 0 vtpVlanTranslationalVlan1.1.1005 = 0 vtpVlanTranslationalVlan2.1.1 = 1003 vtpVlanTranslationalVlan2.1.1002 = 1003 vtpVlanTranslationalVlan2.1.1003 = 1002 vtpVlanTranslationalVlan2.1.1004 = 0 vtpVlanTranslationalVlan2.1.1005 = 0 vtpVlanBridgeType.1.1003 = srb vtpVlanAreHopCount.1.1003 = 7 vtpVlanSteHopCount.1.1003 = 7 vtpVlanIsCRFBackup.1.1003 = false VTP Domain 1 1.SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dStpPortEntry] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dBasePortIfIndex] 1002. 1003. 1004. 1005. VLAN 1 VLAN 1002 VLAN 1003 VLAN 1004 VLAN 1005 >> Runtime for discovery module 'vlans': 12.3800 seconds with 15384 bytes #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ toner ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 diskIOEntry] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '29'] >> Runtime for discovery module 'ucd-diskio': 0.0240 seconds with 720 bytes #### Unload disco module ucd-diskio #### Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes #### Unload disco module services #### Modules status: Global- OS Device Module [ stp ] disabled globally. Modules status: Global+ OS Device #### Load disco module ntp #### SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' AND `type` = 'ntp' )] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.168.1.2.1.1] .*.*.*.1 No Such Object available on this agent at this OID Objects Found: SQL[SELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = '29' )] SQL[DELETE FROM `applications` WHERE `device_id` = '29' AND `app_type` = 'ntp'] >> Runtime for discovery module 'ntp': 0.0250 seconds with 1064 bytes #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '29' AND `attrib_type` = 'poll_mib' ] SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='19.06' WHERE `device_id` = '29'] Discovered in 19.06 seconds SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','company_Tesla_linkx','1487851177.5328','19.10','1','HQ_Switch01\n')] ./discovery.php company_Tesla_linkx 2017-02-23 13:59:56 - 1 devices discovered in 19.10 secs SNMP: Get[12/0.26s] Walk [73/14.17s] MySQL: Cell[74/0.05s] Row[82/0.05s] Rows[43/0.03s] Column[1/0.00s] Update[34/0.03s] Insert[22/0.02s] Delete[1/0.00s]