Meraki AP always issues alerts for Up/Down as #4587

Closed
zamolxe opened this Issue Sep 25, 2016 · 1 comment

Projects

None yet

1 participant

@zamolxe
zamolxe commented Sep 25, 2016

DO NOT DELETE THIS INFORMATION.

Please read this information carefully.

  • Is your install up to date? Updating your install
    Please do not submit an issue if your install is not up to date within the last 24 hours or on a stable monthly release.
  • Please include all of the information between the ==================================== section of ./validate.php.
  • If you would like us to add a new device then please provide the information asked for here
  • Please provide as much detail as possible.

Meraki AP ( MR18) does always issue alerts for Up/Down since it doesn't provide uptime over snmp,
maybe this could be avoided somehow if snmp uptime is not available.
Poller output in debug mode is below:
http://pastebin.com/5zBEGBf5

/Alex

@crcro crcro referenced this issue Sep 27, 2016
Merged

fix: device with no uptime #4625

2 of 2 tasks complete
@laf laf closed this in #4625 Sep 27, 2016
@laf laf added a commit that referenced this issue Sep 27, 2016
@crcro @laf crcro + laf fix: device with no uptime (#4625)
fix: Add checks for devices with no uptime over snmp #4587
f06b0ff
@zamolxe
zamolxe commented Sep 29, 2016

Hi guys,
Just some feedback, the up/down alerts have been fixed, but now device rebooted alerts started to be issued.

/Alex

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment