Notifications
You must be signed in to change notification settings - Fork 10
/
Copy pathDummyPlcService.cs
108 lines (85 loc) · 2.74 KB
/
DummyPlcService.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading;
using System.Threading.Tasks;
namespace SimpleHmi.PlcService
{
public class DummyPlcService : IPlcService
{
public ConnectionStates ConnectionState { get; private set; }
public bool HighLimit { get; private set; }
public int InletPumpSpeed { get; private set; }
public bool LowLimit { get; private set; }
public int OutletPumpSpeed { get; private set; }
public bool PumpState { get; private set; }
public TimeSpan ScanTime { get; private set; }
public int TankLevel { get; private set; }
public event EventHandler ValuesRefreshed;
private System.Timers.Timer _timer;
private DateTime _lastScanTime;
public DummyPlcService()
{
_timer = new System.Timers.Timer();
_timer.Elapsed += OnTimerElapsed;
_timer.Interval = 100;
InletPumpSpeed = 3;
OutletPumpSpeed = 2;
}
private void OnTimerElapsed(object sender, System.Timers.ElapsedEventArgs e)
{
_timer.Stop();
TankLevel -= OutletPumpSpeed;
TankLevel = Math.Max(TankLevel, 0);
if (PumpState)
{
TankLevel += InletPumpSpeed;
TankLevel = Math.Min(TankLevel, 100);
}
LowLimit = TankLevel < 10;
HighLimit = TankLevel > 90;
ScanTime = DateTime.Now - _lastScanTime;
OnValuesRefreshed();
_timer.Start();
_lastScanTime = DateTime.Now;
}
public void Connect(string ipAddress, int rack, int slot)
{
ConnectionState = ConnectionStates.Connecting;
OnValuesRefreshed();
ConnectionState = ConnectionStates.Online;
_timer.Start();
}
public void Disconnect()
{
ConnectionState = ConnectionStates.Offline;
OnValuesRefreshed();
_timer.Stop();
}
public Task WriteSpeedInletPump(short speed)
{
return Task.Run(() => { InletPumpSpeed = speed; });
}
public Task WriteSpeedOutletPump(short speed)
{
return Task.Run(() => { OutletPumpSpeed = speed; });
}
public Task WriteStart()
{
return Task.Run(() => {
PumpState = true;
});
}
public Task WriteStop()
{
return Task.Run(() => {
PumpState = false;
});
}
private void OnValuesRefreshed()
{
ValuesRefreshed?.Invoke(this, new EventArgs());
}
}
}