Clarification on fmi2SetupExperiment startTime and stopTime #474

Open
hyumo opened this Issue Oct 30, 2018 · 0 comments

Comments

Projects
None yet
1 participant
@hyumo

hyumo commented Oct 30, 2018

It is unclear if stopTime should be greater than startTime in fmi2SetupExperiment when stopTimeDefined is true.

It might be good to

  • Clarify that stopTime must be greater than startTime explicitly in the spec.
  • Clarify the return value of fmi2SetupExperiment when startTime == stopTime and startTime > stopTime.

BTW: It seems that integrating backwards is not considered in FMI standard, but should this be considered in the FMI standard as well? i.e. StopTime < StartTime and communicationTimeStep < 0