ramips: change status LED for Buffalo WHR-G300N

Buffalo WHR-G300N has a LED for power status indication, but it is not
connected to the GPIO and cannot be controlled by the kernel. So,
WHR-G300N uses "ROUTER" LED as the system status LED instead.

This commit changes it to use "DIAG" LED insted of "ROUTER" like
WHR-G301N in ath79 target.

Signed-off-by: INAGAKI Hiroshi <musashino.open@gmail.com>
  • Loading branch information...
musashino205 authored and chunkeey committed Feb 3, 2019
1 parent 7bf6b59 commit e52ad0f919b6311e391a44215c4ac19b948f0b72
Showing with 5 additions and 6 deletions.
  1. +5 −6 target/linux/ramips/dts/WHR-G300N.dts
@@ -10,10 +10,9 @@
model = "Buffalo WHR-G300N";

aliases {
led-boot = &led_router;
led-failsafe = &led_router;
led-running = &led_router;
led-upgrade = &led_router;
led-boot = &led_diag;
led-failsafe = &led_diag;
led-upgrade = &led_diag;
};

cfi@1f000000 {
@@ -62,12 +61,12 @@
leds {
compatible = "gpio-leds";

diag {
led_diag: diag {
label = "whr-g300n:red:diag";
gpios = <&gpio0 7 GPIO_ACTIVE_LOW>;
};

led_router: router {
router {
label = "whr-g300n:green:router";
gpios = <&gpio0 9 GPIO_ACTIVE_LOW>;
};

0 comments on commit e52ad0f