// TinyTX_Water - An ATtiny84 and RFM12B Leak/Flood sensor
// By Nathan Chantrell. For hardware design see http://nathan.chantrell.net/tinytx
//
// Wire probes on A0 (ATtiny pin 13) and ground and 100K between A0 and D9 (ATtiny pin 12)
// See TinyTX_Water_RX for a receiver example
//
// Licenced under the Creative Commons Attribution-ShareAlike 3.0 Unported (CC BY-SA 3.0) licence:
// http://creativecommons.org/licenses/by-sa/3.0/
//
// Requires Arduino IDE with arduino-tiny core: http://code.google.com/p/arduino-tiny/
//----------------------------------------------------------------------------------------------------------------------
#include <JeeLib.h> // https://github.com/jcw/jeelib
ISR(WDT_vect) { Sleepy::watchdogEvent(); } // interrupt handler for JeeLabs Sleepy power saving
#define myNodeID 1 // RF12 node ID in the range 1-30
#define network 210 // RF12 Network group
#define freq RF12_433MHZ // Frequency of RFM12B module
#define USE_ACK // Enable ACKs, comment out to disable
#define RETRY_PERIOD 5 // How soon to retry (in seconds) if ACK didn't come in
#define RETRY_LIMIT 5 // Maximum number of times to retry
#define ACK_TIME 10 // Number of milliseconds to wait for an ack
int CAL = 400; // Analogue reading below which will trigger a tx
//########################################################################################################################
//Data Structure to be sent
//########################################################################################################################
typedef struct {
int alarm; // alarm status
int supplyV; // Supply voltage
} Payload;
Payload tinytx;
// Wait a few milliseconds for proper ACK
#ifdef USE_ACK
static byte waitForAck() {
MilliTimer ackTimer;
while (!ackTimer.poll(ACK_TIME)) {
if (rf12_recvDone() && rf12_crc == 0 &&
rf12_hdr == (RF12_HDR_DST | RF12_HDR_CTL | myNodeID))
return 1;
}
return 0;
}
#endif
//--------------------------------------------------------------------------------------------------
// Send payload data via RF
//-------------------------------------------------------------------------------------------------
static void rfwrite(){
#ifdef USE_ACK
for (byte i = 0; i <= RETRY_LIMIT; ++i) { // tx and wait for ack up to RETRY_LIMIT times
rf12_sleep(-1); // Wake up RF module
while (!rf12_canSend())
rf12_recvDone();
rf12_sendStart(RF12_HDR_ACK, &tinytx, sizeof tinytx);
rf12_sendWait(2); // Wait for RF to finish sending while in standby mode
byte acked = waitForAck(); // Wait for ACK
rf12_sleep(0); // Put RF module to sleep
if (acked) { return; } // Return if ACK received
Sleepy::loseSomeTime(RETRY_PERIOD * 1000); // If no ack received wait and try again
}
#else
rf12_sleep(-1); // Wake up RF module
while (!rf12_canSend())
rf12_recvDone();
rf12_sendStart(0, &tinytx, sizeof tinytx);
rf12_sendWait(2); // Wait for RF to finish sending while in standby mode
rf12_sleep(0); // Put RF module to sleep
return;
#endif
}
//--------------------------------------------------------------------------------------------------
// Read current supply voltage
//--------------------------------------------------------------------------------------------------
long readVcc() {
bitClear(PRR, PRADC); ADCSRA |= bit(ADEN); // Enable the ADC
long result;
// Read 1.1V reference against Vcc
#if defined(__AVR_ATtiny84__)
ADMUX = _BV(MUX5) | _BV(MUX0); // For ATtiny84
#else
ADMUX = _BV(REFS0) | _BV(MUX3) | _BV(MUX2) | _BV(MUX1); // For ATmega328
#endif
delay(2); // Wait for Vref to settle
ADCSRA |= _BV(ADSC); // Convert
while (bit_is_set(ADCSRA,ADSC));
result = ADCL;
result |= ADCH<<8;
result = 1126400L / result; // Back-calculate Vcc in mV
ADCSRA &= ~ bit(ADEN); bitSet(PRR, PRADC); // Disable the ADC to save power
return result;
}
//########################################################################################################################
void setup() {
rf12_initialize(myNodeID,freq,network); // Initialize RFM12 with settings defined above
rf12_sleep(0); // Put the RFM12 to sleep
pinMode(9, OUTPUT); // set D9 to output
}
void loop() {
digitalWrite(9, HIGH); // set D9 high
delay(10);
bitClear(PRR, PRADC); ADCSRA |= bit(ADEN); // Enable the ADC
int reading = analogRead(0);
ADCSRA &= ~ bit(ADEN); bitSet(PRR, PRADC); // Disable the ADC to save power
digitalWrite(9, LOW); // set D9 low
tinytx.supplyV = readVcc(); // Get supply voltage
if (reading < CAL){ // water detected
tinytx.alarm = 999; // set the alarm message
rfwrite(); // Send data via RF
}
if (tinytx.supplyV < 2500){ // low battery
tinytx.alarm = 100; // set the alarm message
rfwrite(); // Send data via RF
}
Sleepy::loseSomeTime(30000); //JeeLabs power save function: enter low power mode for 30 seconds (valid range 16-65000 ms)
}