Notifications
You must be signed in to change notification settings - Fork 19
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
How to beta test prior to the Home Assistant Pull Request #1
Comments
Thanks for the comment. I'm eager to get this module up to a point where I can integrate it with my Home Assistant platform (running on a Raspi). One thing to consider is that there are actually three protocols at play here which will need to be embodied in the device. There's the INSTEON Standard with 9 byte packages, and the INSTEON Extended with 23 byte packets. Those are both encapsulated inside the PLM's protocol, which is what I'm currently focused on supporting with the module. The PLM protocol is sort of wonky. Commands are prefixed with a 0x02 character, but since messages can legitimately contain a 0x02 you can't simply use it as a straight delimiter. Instead, the protocol handler will need to exhaustively understand the protocol in order to successfully parse out the receive stream into unique messages. I'm unsettled on the best way to store the constants and command attributes in the code to ensure that we can easily work with them and they contain all the relevant information. My immediate plan is to bang around with the commands "by hand" until I have more confidence that I understand it enough to map it out sanely in the code. From there we get to tackle the actual INSTEON protocols that receive status and send requests to the actual devices. |
Yes, I think there is an inherent problem in the PLM's protocol as result of reusing 0x02 in messages; I read this (documentation for a Perl module): http://misterhouse.sourceforge.net/lib/Insteon/MessageDecoder.html and interpreted it as that problem. Maybe if you update the state of all messages, verifying ACK/NAK for everything? Because of my limited needs, I don't really care about things like Extended messages or even monitoring/inquiring about state. Being able to link devices is probably necessary just so that the all-devices-off command works, but that's only necessary to avoid running around the house once or twice. Anyway, thanks for starting this; I hope I can contribute something useful in time. |
Today's changes embody the PLM protocol in an abstracted class that I'm fairly content with. It should support the few weird variable-length message exceptions I'm seeing in the developer docs for the PLM device. I did a quick and dirty wrapper for message x50 (standard INSTEON) just to sanity check the parsing and it looks good. This will need to be restructured, but it's serviceable for now. I haven't even started thinking aobut the device pairing process, although that shouldn't be too tough.
|
Terrific, I just got the new controller today and hope to be able to work on it tomorrow / this weekend. I'll let you know what I find, if anything. |
I was working with my Insteon PLM and the developer docs a few weeks ago and was having the same issue with the Insteon message types. It's frustrating that you need to read the message to know how to read the message! The message flags can mean so many different things as well. I'm a beginner so this is probably ugly, but this was my solution (borrowing a bit from some other projects, of course) to parsing the first half of the message flags: `
` At the very least it would have been nice of them to pass the checksum along so you could calculate it on the fly and (hopefully) know that you had a complete message instead of some garbage. I like your project and I absolutely want to see this happen. I get that Insteon is old tech at this point but I really like their plug-in dimmer modules (A button for bright/on, a button for dim/off, local sensing - the things we take for granted.). I also have some Insteon hidden door sensors installed for my deadbolts to activate when latched. (I have to confess: I may have a few in-wall X10 modules lingering in my home. Something, something, no neutral wires.) I'm really glad you're doing this and I'll be happy to help contribute in whatever small way I can. |
If anyone is interested in testing, this process should get you up and running: https://github.com/nugget/python-insteonplm/blob/master/HASS.md If you do get it set up I'd love to know how it goes. |
This looks great; I'm going to try and get it up and running sometime
between now and this weekend.
Eric.
On 2017-02-16 14:15, David McNett wrote:
If anyone is interested in testing, this process should get you up and running:
https://github.com/nugget/python-insteonplm/blob/master/HASS.md
If you do get it set up I'd love to know how it goes.
--
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub [1], or mute the thread [2].
|
Alright, after installing the package in custom components and adjusting my config files this is what I've experienced so far:
I haven't delved into the logging yet so I don't have any actual logs to provide for you yet. That said I think you have gone above and beyond in your implementation. I was not expecting it to get the database of Insteon devices from the PLM, something that feels like magic to me right now. In fact, after looking at your code everything seems like magic to me and I'm stoked to see what you come up with next. |
Excellent, I'm glad to hear you're up and running (to a point) with the code. I got dynamic platform loading working, so it's no longer necessary to explicitly load the insteon_plm for each platform (light, switch, etc...). You just need to load the main insteon_plm component at the root level of your configuration.yaml now. I revised the beta docs in HASS.md to reflect that. As luck would have it, I happen to have a few of the door sensor devices (2845-222) laying around the house that I never got around to installing. I was able to expand the IPDB in the codebase and add support for device category 0x10 generically. I've got one working with my hass install now. I don't have any theory at all about the weird double-addressed light device. That's truly bizarre. I'm curious about dimming for your 2457D2 devices. I have no way to test directly, but that should be working. The devices are advertising dimmability to hass and you should be able to both adjust the dim level from the hass frontend UI as well as see dimming reflected when you manually control the device. It's definitely working fine for my 2477D wall switches. Perhaps the 2457D2s behave differently somehow. I'll dig through the spec and see if I can find anything suspicious. New insteonplm is pushed out to pypi and I updated the custom_component tarball just now. |
I removed everything in custom_components and then re-downloaded and untarred the contents of insteon_plm_beta.tar.gz into it. I can see the devices being discovered when HASS starts up but I think I'm missing a piece of the puzzle because this shows up in my log now: `17-02-17 16:23:21 ERROR (MainThread) [homeassistant.loader] Error loading custom_components.binary_sensor.insteon_plm. Make sure all dependencies are installed I've removed /deps and home-assistant_v2.db then did |
Ahh, I see the issue... |
OK, I figured out a workaround. Need to change all the lines in the platform files that say I rolled a new tarball but you may find it easier to just edit the three files locally. |
Well that's perfect, excellent. |
This is embarrassing. You know that 2845-222 Hidden Door Sensor I said was working as expected? Yeah, I was looking at a sensor template. I'm not getting anything from it at all. When I pair it I can see the ALL-Link command for it in the log, but after that when I press or release the button I get nothing in the log. I found a document with developer notes for the Hidden Door Sensor, maybe it will help? |
I found that with the 2845-222 I had to do the ALL-Link pairing in both directions before the device started sending updates to my PLM. I paired it the first time by press-holding the set button on the PLM and then press-holding the set button on the sensor. That added it to the ALDB on the PLM. But then I was seeing what you're seeing -- no messages at all on the PLM. I did the pairing the other direction (press-hold on the device, then on the PLM) and I started seeing the traffic. Before I did the second pairing, there was no insteon message traffic at all as seen by the PLM. |
That did it! I should know better by now to always pair Insteon devices both ways. I think I'll wait until tomorrow before I do that to the one installed in the front door. I think my wife is getting a bit tired of me constantly messing with the front door lock. (It's installed in the door frame so the deadbolt actuates the switch.) How much effort do you think it would take to get the battery level data from the device as well? |
Oh, the battery warning will be pretty simple, actually. I ran across that when I was looking at the dev docs for the device but I didn't want to get distracted so I shelved that work for now. It's definitely on the list and shouldn't be hard at all. The device doesn't support a literal battery level, but it will emit a low battery warning that will be no problem to detect and emit in hass. |
Also, from the user manual, you can do the pairing for the 2845 after it's been installed by double-clicking the actuator button. So tomorrow you won't have to rip it out of the doorframe to pair it. The process is described in the user manual http://cache.insteon.com/documentation/2845-222-en.pdf |
Oh sweet, thanks! That saves me a bunch of work. Battery low info would be super handy. I'm pretty sure there's a way to get the battery level info as well but I only know this because the OpenHAB binding supports it (unless the OpenHAB binding has been lying this whole time, but I seems to accurate to be a fictional thing). I don't see anything about it in the dev docs so there must be some arcane magic involved, perhaps by reading memory locations? |
Did a little investigation into the OpenHAB binding and I discovered something. From src/main/resources/device_features.xml:
Then, from src/main/java/org/openhab/binding/insteonplm/internal/device/MessageHandler.java:
It looks like it's sending cmd 2e and then getting the battery level from the User Data 4 byte of the extended-length response. I had originally interpreted that little bit on page 9 as returning the level at which the low battery level alert is tripped, but since I get convincingly accurate battery level info from OpenHAB perhaps Data 4 is the actual battery level and Data 7 is actually the level where the alert gets tripped? Edit: Finally read the docs on Markdown formatting. |
I've submitted a pull request to have this component included in the main home assistant codebase. Lots of changes today and yesterday, reflected in an updated tarball as linked above. |
I'm not sure if there's a better place to say this now that's in dev. I removed all of the old custom components and upgraded to the homeassistant dev branch. So far so good. Also, that strange 'light.accf23c5814a' item no longer appears now that I'm on the dev branch. Not sure why but it could be worth mentioning. |
Hi David. Imagine my luck: I just got my Insteon PLM a few days ago, began researching Python control for it, and BOOM -- up comes your repo!
My inspiration is twofold:
I'm currently waiting for the delivery of another RemoteLinc (2342-222) with which to experiment -- I can't remove any of my current controllers from service (i.e., linked to existing PLM) or I endure the wrath of the other user of our Insteon control system, iykwim. So at the moment I'm unable to generate any events to be received by the PLM, but that will change in a couple of days.
It looks like the next steps for this library might be something like making a (public) send_message() in protocol.py that understands the various Insteon message types? Curious about your thoughts on this.
Ultimately, my needs aren't very fancy: I have a system that uses Insteon almost exclusively for lighting, and all the lights are controlled via (sunset-offset, mostly) timers, with a few wired and wireless controllers around for all-units-off commands (bedside) and to control some small groups (which doesn't require any PLM interaction, really).
I got all of your code running on a CHIP (https://getchip.com/pages/chip), although I may end up with a Raspi because I think I have wired Ethernet where I need it.
Looking forward to seeing where this goes, and how I might be able to help!
The text was updated successfully, but these errors were encountered: