Notifications
You must be signed in to change notification settings - Fork 83
/
Copy pathEmonHubSDM120Interfacer.py
121 lines (93 loc) · 3.91 KB
/
EmonHubSDM120Interfacer.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
import time
import json
import Cargo
import os
import glob
from emonhub_interfacer import EmonHubInterfacer
"""
[[SDM120]]
Type = EmonHubSDM120Interfacer
[[[init_settings]]]
device = /dev/ttyUSB0
baud = 2400
[[[runtimesettings]]]
pubchannels = ToEmonCMS,
read_interval = 10
nodename = sdm120
"""
"""class EmonHubSDM120Interfacer
SDM120 interfacer for use in development
"""
class EmonHubSDM120Interfacer(EmonHubInterfacer):
def __init__(self, name, device="/dev/modbus", baud=2400):
"""Initialize Interfacer
"""
# Initialization
super(EmonHubSDM120Interfacer, self).__init__(name)
# This line will stop the default values printing to logfile at start-up
# self._settings.update(self._defaults)
# Interfacer specific settings
self._SDM120_settings = {'read_interval': 10.0,'nodename':'sdm120'}
self.next_interval = True
# Only load module if it is installed
try:
import sdm_modbus
self._log.info("Connecting to SDM120 device="+str(device)+" baud="+str(baud))
self._sdm = sdm_modbus.SDM120(device="/dev/modbus", baud=2400)
self._sdm_registers = sdm_modbus.registerType.INPUT
except ModuleNotFoundError as err:
self._log.error(err)
self._sdm = False
def read(self):
"""Read data and process
Return data as a list: [NodeID, val1, val2]
"""
if int(time.time())%self._settings['read_interval']==0:
if self.next_interval:
self.next_interval = False
c = Cargo.new_cargo()
c.names = []
c.realdata = []
c.nodeid = self._settings['nodename']
if self._sdm and self._sdm.connected():
r = self._sdm.read_all(self._sdm_registers)
# for i in r:
# self._log.debug(i+" "+str(r[i]))
self._log.debug("%.2f %.2f %.4f %.4f %.3f %.3f" % (r['voltage'],r['power_active'],r['power_factor'],r['frequency'],r['import_energy_active'],r['current']))
c.names = ['sdm_V','sdm_P','sdm_PF','sdm_FR','sdm_E','sdm_I']
c.realdata = [
round(r['voltage'],2),
round(r['power_active'],2),
round(r['power_factor'],4),
round(r['frequency'],4),
round(r['import_energy_active'],3),
round(r['current'],3)
]
if len(c.realdata)>0:
return c
else:
self._log.error("Could not read from SDM120")
else:
self.next_interval = True
return False
def set(self, **kwargs):
for key, setting in self._SDM120_settings.items():
# Decide which setting value to use
if key in kwargs:
setting = kwargs[key]
else:
setting = self._SDM120_settings[key]
if key in self._settings and self._settings[key] == setting:
continue
elif key == 'read_interval':
self._log.info("Setting %s read_interval: %s", self.name, setting)
self._settings[key] = float(setting)
continue
elif key == 'nodename':
self._log.info("Setting %s nodename: %s", self.name, setting)
self._settings[key] = str(setting)
continue
else:
self._log.warning("'%s' is not valid for %s: %s", setting, self.name, key)
# include kwargs from parent
super().set(**kwargs)