Skip to content

vD4.10.2.EU | UK / EU specific changes

Pre-release
Pre-release
Compare
Choose a tag to compare
@glynhudson glynhudson released this 14 Nov 15:00

UK / EU specific changes

  • Enable MENNEKES_LOCK
  • Disable AUTOSVCLEVEL (autodetection is designed for split-phase and does't work on single-phase systems)
  • Set charging level default to L2
  • Set MAX_CURRENT_CAPACITY_L2 32 amps (recommended limit for single-phase charging in UK/EU)
  • Append .EU to version number

Note: Mennekes Lock requires external 12V motor driver e.g Polulu 1451. Pins D11 (MOSI) , D12 (MISO) are used for the lock.

Other changes compared to V4.8.0:

  • Remove 10A minimum current limitation, restore 6A minimum (J1772)
  • RAPI $FF command and deprecates all other enable/disable commands, i.e. SD/SE/SF/SG/SR/SV
    • RAPI API version V3.0.1 > V4.0.0
  • For all changes see CHANGELOG