In order to use this mechanism driver the Neutron configuration file needs to be created/updated with the appropriate configuration information.
Each managed switch is configured as a section in the form
[genericswitch:<switch name>]. The device_type entry is mandatory and
determines which driver is used. Most other configuration entries are optional.
Note
Switch will be selected by local_link_connection/switch_info or ngs_mac_address. So, you can use the switch MAC address to identify switches if local_link_connection/switch_info is not set.
The GenericSwitch mechanism driver needs to be enabled from
the ml2 config file /etc/neutron/plugins/ml2/ml2_conf.ini:
[ml2] project_network_types = vlan type_drivers = local,flat,vlan,gre,vxlan mechanism_drivers = openvswitch,genericswitch ...
Physical networks need to be declared in the ML2 config as well, with a range
of VLANs that can be allocated to project networks. Several physical networks
can coexist, possibly with overlapping VLAN ranges: in that case, each switch
configuration needs to include its physical network, see :ref:`physicalnetworks`.
Example of /etc/neutron/plugins/ml2/ml2_conf.ini with two physical networks:
[ml2_type_vlan] network_vlan_ranges = physnet1:700:799,physnet2:600:850
For a given physical network, it is possible to specify several disjoint ranges of VLANs by simply repeating the physical network name multiple times:
[ml2_type_vlan] network_vlan_ranges = physnet1:700:720,physnet1:750:760
If drivers support security groups then genericswitch_security_group can be appended
to the list of service_plugins (this also needs to be enabled per switch configuration):
[DEFAULT] service_plugins = qos,ovn-router,trunk,segments,port_forwarding,log,genericswitch_security_group
(Re)start neutron-server specifying the additional configuration file
containing switch configuration:
neutron-server \
--config-file /etc/neutron/neutron.conf \
--config-file /etc/neutron/plugins/ml2/ml2_conf.ini \
--config-file /etc/neutron/plugins/ml2/ml2_conf_genericswitch.ini
For operational topics such as performance tuning, VXLAN L2VNI support, and advanced features, see the :doc:`admin/index` guide.
These example device configuration snippets are assumed to be part of a
specific file /etc/neutron/plugins/ml2/ml2_conf_genericswitch.ini, but
they could also be added directly to /etc/neutron/plugins/ml2/ml2_conf.ini.
Every switch section accepts a set of ngs_ options that apply across
device drivers. See :ref:`configuration-reference` for the complete list
with each option's type and default. A few options have extra context
documented elsewhere:
ngs_mac_address— lets a switch be identified by MAC address whenlocal_link_connection/switch_infois not set (see the note above).ngs_manage_mtu— must be enabled before any MTU commands are sent to the switch. See :doc:`admin/general-configuration` for details.ngs_save_configuration— for NETCONF devices targeting the running datastore, this controls whether the driver attempts to persist the configuration (see :ref:`netconf-persistence`).
Switch configuration format:
[genericswitch:<switch name>] device_type = <netmiko device type> ngs_mac_address = <switch mac address> ip = <IP address of switch> port = <ssh port> username = <credential username> password = <credential password> use_keys = <set to True when key_file is set> key_file = <ssh key file> secret = <enable secret> ngs_allowed_vlans = <comma-separated list of allowed vlans for switch> ngs_allowed_ports = <comma-separated list of allowed ports for switch>
Netmiko (SSH/CLI) devices accept several additional ngs_ options
controlling SSH connection behaviour and request batching
(ngs_batch_requests, ngs_ssh_connect_timeout,
ngs_ssh_reuse_connection and others). See :ref:`configuration-reference`
for the full list. Note that ngs_batch_requests requires etcd
coordination; see :ref:`batching`.
Here is an example for the Cisco 300 series device:
[genericswitch:sw-hostname] device_type = netmiko_cisco_s300 ngs_mac_address = <switch mac address> username = admin password = password ip = <switch mgmt ip address>
for the Cisco IOS device:
[genericswitch:sw-hostname] device_type = netmiko_cisco_ios ngs_mac_address = <switch mac address> username = admin password = password secret = secret ip = <switch mgmt ip address>
for the Cisco NX-OS device:
[genericswitch:sw-hostname] device_type = netmiko_cisco_nxos ngs_mac_address = <switch mac address> # if security group support is required ngs_security_groups_enabled = True ip = <switch mgmt ip address> username = admin password = password secret = secret
for the Huawei VRPV3 or VRPV5 device:
[genericswitch:sw-hostname] device_type = netmiko_huawei ngs_mac_address = <switch mac address> username = admin password = password port = 8222 secret = secret ip = <switch mgmt ip address>
for the Huawei VRPV8 device:
[genericswitch:sw-hostname] device_type = netmiko_huawei_vrpv8 ngs_mac_address = <switch mac address> username = admin password = password port = 8222 secret = secret ip = <switch mgmt ip address>
for the Arista EOS device:
[genericswitch:arista-hostname] device_type = netmiko_arista_eos ngs_mac_address = <switch mac address> ip = <switch mgmt ip address> username = admin key_file = /opt/data/arista_key
for the Dell Force10 device:
[genericswitch:dell-hostname] device_type = netmiko_dell_force10 ngs_mac_address = <switch mac address> ip = <switch mgmt ip address> username = admin password = password secret = secret
for the Dell OS10 device:
[genericswitch:dell-hostname] device_type = netmiko_dell_os10 ngs_mac_address = <switch mac address> ip = <switch mgmt ip address> username = admin password = password secret = secret
for the Dell PowerConnect device:
[genericswitch:dell-hostname] device_type = netmiko_dell_powerconnect ip = <switch mgmt ip address> username = admin password = password secret = secret # You can set ngs_switchport_mode according to switchmode you have set on # the switch. The following options are supported: general, access. It # will default to access mode if left unset. In general mode, the port # be set to transmit untagged packets. ngs_switchport_mode = access
Dell PowerConnect devices have been seen to have issues with multiple concurrent configuration sessions. See :ref:`synchronization` and :ref:`batching` for details on how to limit the number of concurrent active connections to each device.
for the Brocade FastIron (ICX) device:
[genericswitch:hostname-for-fast-iron] device_type = netmiko_brocade_fastiron ngs_mac_address = <switch mac address> ip = <switch mgmt ip address> username = admin password = password
for the Ruijie device:
[genericswitch:sw-hostname] device_type = netmiko_ruijie ngs_mac_address = <switch mac address> username = admin password = password secret = secret ip = <switch mgmt ip address>
for the HPE 5900 Series device:
[genericswitch:sw-hostname] device_type = netmiko_hp_comware username = admin password = password ip = <switch mgmt ip address>
for the Juniper Junos OS device:
[genericswitch:hostname-for-juniper] device_type = netmiko_juniper ip = <switch mgmt ip address> username = admin password = password ngs_commit_timeout = <optional commit timeout (seconds)> ngs_commit_interval = <optional commit interval (seconds)>
for a Cumulus Linux device:
[genericswitch:hostname-for-cumulus] device_type = netmiko_cumulus ip = <switch mgmt_ip address> username = admin password = password secret = secret ngs_mac_address = <switch mac address>
for a Cumulus NVUE Linux device:
[genericswitch:hostname-for-cumulus] device_type = netmiko_cumulus_nvue ip = <switch mgmt_ip address> username = admin password = password secret = secret ngs_mac_address = <switch mac address>
for the Nokia SRL series device:
[genericswitch:sw-hostname] device_type = netmiko_nokia_srl username = admin password = password ip = <switch mgmt ip address>
for a Pluribus switch:
[genericswitch:sw-hostname] device_type = netmiko_pluribus username = admin password = password ip = <switch mgmt ip address>
for an ArubaOS-CX switch:
[genericswitch:aruba-hostname] device_type = netmiko_aruba_aoscx username = admin password = password ip = <switch mgmt ip address>
for the Supermicro device:
[genericswitch:sw-hostname] device_type = netmiko_supermicro_smis ngs_mac_address = <switch mac address> ip = <switch mgmt ip address> username = admin password = password secret = secret
NETCONF devices use host (not ip) and connect via the NETCONF
protocol (port 830 by default). Connection parameters are passed directly
to ncclient.
Switch configuration format:
[genericswitch:<switch name>] device_type = <netconf device type> ngs_mac_address = <switch mac address> ngs_physical_networks = <comma-separated list of physical networks> host = <IP address or hostname of switch> port = <NETCONF port, default 830> username = <credential username> password = <credential password> key_filename = <ssh key file> hostkey_verify = <true or false> device_params = <ncclient device handler, e.g. name:nexus>
NETCONF devices accept additional ngs_ options such as
ngs_openconfig_network_instance, ngs_port_id_re_sub and
ngs_openconfig_disabled_properties. See :ref:`configuration-reference`
for the full list with types and defaults. Datastore selection
(ngs_netconf_target) and configuration persistence
(ngs_netconf_save_config) are covered in detail below.
The confirmed-commit options warrant additional operational context:
ngs_netconf_confirmed_commit— whether to use confirmed commit when the switch advertises the:confirmed-commitcapability. Set tofalseto skip the tentative commit entirely. This is useful for switches that hold their config backend busy for the full timeout window (e.g. Cisco NX-OS), blocking concurrent sessions.ngs_netconf_confirmed_commit_timeout— rollback timeout in seconds for the tentative confirmed commit. Only used when confirmed commit is enabled and the switch advertises the capability. The confirming commit is sent immediately after the tentative commit, so a small value is usually sufficient.
The driver automatically detects which NETCONF datastore to use based on the capabilities advertised in the server's hello message:
- If the switch advertises the
:candidatecapability, the driver uses the candidate datastore with lock, discard, edit-config, validate, confirmed-commit, and commit. - If only
:writable-runningis available, the driver edits the running datastore directly with lock and edit-config.
Set ngs_netconf_target to override auto-detection when the device's
candidate datastore is known to be unreliable.
When the target datastore is candidate, the commit operation implicitly
persists the configuration. When targeting the running datastore
directly, an additional step is needed to save the configuration to
non-volatile storage so it survives a reboot.
The driver attempts to persist the running configuration when
ngs_save_configuration is enabled, using the following priority:
- Custom save config — if
ngs_netconf_save_configis configured, the driver sends it as anedit-configto the running datastore. - copy-config to startup — if the device advertises the
:startupcapability, the driver performscopy-configfromrunningtostartup. - Warning — if neither mechanism is available, the driver logs a warning that the configuration cannot be persisted.
Vendor examples for ngs_netconf_save_config:
Arista EOS (via the arista-cli YANG module):
ngs_netconf_save_config = <config><commands xmlns="http://arista.com/yang/cli"><command>write memory</command></commands></config>
Cisco IOS (via CLI config data):
ngs_netconf_save_config = <config><cli-config-data><cmd>write memory</cmd></cli-config-data></config>
For a NETCONF OpenConfig device:
[genericswitch:sw-hostname]
device_type = netconf_openconfig
ngs_mac_address = <switch mac address>
ngs_physical_networks = physnet1
ngs_trunk_ports = Ethernet1/48
ngs_disable_inactive_ports = True
ngs_port_default_vlan = 1
ngs_port_id_re_sub = {"pattern": "^Eth", "repl": "Ethernet"}
host = <switch mgmt ip address>
port = 830
username = admin
password = password
device_params = name:nexus
For an Arista EOS device via NETCONF (requires targeting the running datastore due to known candidate datastore issues):
[genericswitch:arista-hostname] device_type = netconf_openconfig ngs_mac_address = <switch mac address> ngs_physical_networks = physnet1 ngs_trunk_ports = Ethernet1 ngs_netconf_target = running ngs_save_configuration = true ngs_netconf_save_config = <config><commands xmlns="http://arista.com/yang/cli"><command>write memory</command></commands></config> host = <switch mgmt ip address> username = admin password = password
RESTCONF devices use the RESTCONF protocol (RFC 8040) over HTTPS to push configuration encoded as JSON (RFC 7951). The driver communicates with the device using HTTP PATCH (merge), GET (read), and DELETE (remove) operations against the device's RESTCONF data resource.
Switch configuration format:
[genericswitch:<switch name>] device_type = <restconf device type> ngs_mac_address = <switch mac address> ngs_physical_networks = <comma-separated list of physical networks> host = <IP address or hostname of switch> username = <credential username> password = <credential password>
ngs_restconf_scheme— URL scheme for the RESTCONF endpoint (default:https).port— TCP port for the RESTCONF endpoint (default:443). This is a standard device config option (notngs_-prefixed), consistent with the NETCONF and Netmiko drivers.ngs_restconf_content_type— Media type used inContent-TypeandAcceptheaders (default:application/yang-data+json). Override toapplication/yang.data+jsonfor Cisco NX-OS (see :ref:`restconf-nxos-quirks`).ngs_restconf_base_path— Base path for RESTCONF data resources (default:/restconf/data).ngs_verify_tls— Whether to verify the server's TLS certificate (default:True).ngs_openconfig_network_instance— OpenConfig network-instance for VLAN management (default:default).ngs_port_id_re_sub— JSON object withpatternandreplkeys for regex substitution on port IDs from LLDP. Example:{"pattern": "^Eth", "repl": "Ethernet"}ngs_openconfig_disabled_properties— comma-separated list of properties to omit from configuration payloads (e.g.port_mtu).
If the RESTCONF device returns HTTP 409 (Conflict) or 503 (Service Unavailable), or a connection error occurs, the driver retries with exponential back-off (2 s, 4 s, 5 s, ..., up to 10 attempts). This handles transient lock contention from concurrent operations or temporary unavailability during device-internal commits.
The RESTCONF driver uses the same PoolLock coordination mechanism
as the NETCONF and Netmiko drivers. Configure the coordination backend
and ngs_max_connections as described in the :ref:`synchronization`
section of the administration guide.
The RESTCONF OpenConfig driver supports both infrastructure trunk ports
(ngs_trunk_ports) and Neutron trunk ports (parent + subports). Both
use a converging approach:
Infrastructure trunk ports — When a VLAN is created, if
physnet_vlans is available (the full set of VLANs on the physical
network), the driver writes the complete trunk VLAN list with
operation="replace" in a single PATCH request. This ensures the
switch converges to the exact desired state. If physnet_vlans is
unavailable, the driver falls back to a single-VLAN merge.
Neutron trunk subports — When trunk_details is provided (the full
trunk state including all subports), the driver writes the complete set
of subport VLANs and native VLAN in a single operation="replace"
PATCH. When trunk_details is None (older Neutron releases), it
falls back to per-VLAN merge (add) or per-element remove (delete).
When all subports are removed from a trunk, the port automatically reverts from trunk mode to access mode with the parent VLAN as the access VLAN.
Cisco NX-OS uses a non-standard Content-Type for its RESTCONF
implementation. The standard RFC 8040 media type is
application/yang-data+json, but NX-OS requires the older
draft-era application/yang.data+json (note the dot instead of
hyphen). Configure this as follows:
ngs_restconf_content_type = application/yang.data+json
Additionally, NX-OS port names from LLDP may use abbreviated forms
(e.g. Eth1/31 instead of Ethernet1/31). Use
ngs_port_id_re_sub to normalize:
ngs_port_id_re_sub = {"pattern": "^Eth", "repl": "Ethernet"}
For a RESTCONF OpenConfig device (e.g. Arista EOS with RESTCONF enabled):
[genericswitch:sw-hostname] device_type = restconf_openconfig ngs_mac_address = <switch mac address> ngs_physical_networks = physnet1 ngs_trunk_ports = Ethernet1/48 ngs_disable_inactive_ports = True ngs_port_default_vlan = 1 host = <switch mgmt ip address> username = admin password = password
For a Cisco NX-OS device via RESTCONF:
[genericswitch:nxos-hostname]
device_type = restconf_openconfig
ngs_mac_address = <switch mac address>
ngs_physical_networks = physnet1
ngs_trunk_ports = Ethernet1/48
ngs_disable_inactive_ports = True
ngs_port_default_vlan = 1
ngs_restconf_content_type = application/yang.data+json
ngs_port_id_re_sub = {"pattern": "^Eth", "repl": "Ethernet"}
host = <switch mgmt ip address>
username = admin
password = password
For a device using HTTP (lab only, no TLS):
[genericswitch:lab-switch] device_type = restconf_openconfig ngs_mac_address = <switch mac address> ngs_physical_networks = physnet1 ngs_restconf_scheme = http port = 8080 ngs_verify_tls = False host = <switch mgmt ip address> username = admin password = password