Skip to content

Releases: openstudiocoalition/OpenStudioApplication

OpenStudioApplication v1.4.0

08 Jun 09:20
e0fb8f8
Compare
Choose a tag to compare

The OpenStudio Coalition is proud to release the first release candidate for OpenStudio Application 1.4.0, which has updates to OpenStudio 3.4.0, EnergyPlus 22.1.0.

As a reminder we have strategic roadmap (here are the high level results) which prioritizes education and outreach to states, utilities, and higher education. All this has been funded by founding OpenStudio Coalition members The Energy Coalition, PSD, VEIC, and EffiBEM. To continue our efforts and provide additional support and training, please join us!

What's Changed

New Features:

  • Update to OpenStudio SDK v3.4.0 and EnergyPlus v22.1.0
  • We have bumped the Qt dependency from 5.15 to 6.3.0. As a result Ubuntu-18.04 is no longer officially supported.
  • This is the first release that includes an Apple M1 (arm64) package
  • Internationalization: translate first tab of the app to English, French, Spanish, Chinese, Greek, Polish, Catalan, Farsi-Persian, Hindi, Japanese, Italian, German, Vietnamese by @jmarrec in #354
  • Option to enable Verbose output to run tab + styled fallback when no socket by @jmarrec in #513
  • filter scene by air loop by @antoine-galataud in #497
  • render 3D scene on demand by @antoine-galataud in #510
  • #479 - Find outdated measures in your local BCL folder compared to Online BCL by @jmarrec in #517
  • Enable loop clone by @eringold in #488

Bug Fixes:

  • Fix #477 - SubSurface types don't line up with many subsurfaces in space by @jmarrec in #515
  • Fix #476 - Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters by @jmarrec in #516
  • Fix #428 - Redo dependent dropdowns for Standards Template / Building Type / Space Type by @jmarrec in #514
  • Fixes #494 - Opening simulation run directory fails by @macumber in #502
  • Allow simulation if run socket cannot be opened by @macumber in #484
  • Workaround for #521: download the missing vcomp140.dll by @jmarrec in #525
  • [#501] DesignHeatRecoveryWaterFlowRate field by @j-lorrey in #532
  • 538 crashes by @macumber in #539
  • Fix #522 - Too many new lines in Verbose output on the Run tab on Windows by @jmarrec in #543
  • Fix #535 - Combobox offset when using fractional scaling by @jmarrec in #544

Internal/Developer changes:

New Contributors

Full Changelog: v1.3.1...v1.4.0

Changelog

Date Range: 2021-12-16 (v1.3.0) - 2022-06-08:

New Issues: 40

Closed Issues: 37

Accepted Pull Requests: 32

Total Open Issues: 131

Total Open Pull Requests: 3

Click to see details

Closed Issues: 37

  • #110, Hard to see errors generated in ModelToIdf job in App
  • ✔️ #205, Code signing for Windows installer?
  • #230, Remove explicit constructor cppcheck suppression
  • ✔️ #290, No rendering color for Foundation surfaces in Geometry Viewer
  • #353, OpenStudioApplication 1.2.0 - Release Checklist
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #365, Cannot edit plug load densities on Mac after running simulation and looking at results
  • #413, Geometry preview - air loops
  • ✔️ #415, v1.2.1-rc1 Testing: Call for help from the community
  • ✔️ #428, Standards Building Type does not populate correctly
  • ✔️ #435, v1.2.1 Thermal Zone/ Space Tab in Large Models
  • ✔️ #437, No error message for failed simulation with empty spaces
  • #438, Update to Qt 6.2
  • ✔️ #456, OSApp 1.3.0: Release checklist
  • ✔️ #476, Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters
  • ✔️ #477, SubSurface types don't line up with many subsurfaces in space
  • ✔️ #479, Measure updates on BCL don't work
  • ✔️ #480, compiling current version on ubuntu 20.04
  • ✔️ #483, RunView server port is 0, no run feedback
  • #487, Enable 'x2' button to clone Plant Loops in HVAC Systems tab
  • ✔️ #494, Opening simulation run directory fails
  • ✔️ #495, FloorspaceJSON is corrupted on merge
  • #501, Add field DesignHeatRecoveryWaterFlowRate to the ChillerElectricEIR object
  • ✔️ #503, Network access blocked in reporting measures
  • ✔️ #505, Compile for Mac M1 architecture
  • ✔️ #508, Update OSM libraries to SDK 3.4.0
  • #509, Geometry preview - on-demand rendering
  • ✔️ #519, v1.4.0-rc1 Testing: Call for help from the community
  • ✔️ #521, Need to install vcomp140.dll for EnergyPlus on Windows
  • ✔️ [#522]( https://github.c...

OpenStudioApplication v1.4.0-rc2

03 Jun 11:56
f3d7afb
Compare
Choose a tag to compare
Pre-release

The OpenStudio Coalition is proud to release the first release candidate for OpenStudio Application 1.4.0, which has updates to OpenStudio 3.4.0, EnergyPlus 22.1.0.

As a reminder we have strategic roadmap (here are the high level results) which prioritizes education and outreach to states, utilities, and higher education. All this has been funded by founding OpenStudio Coalition members The Energy Coalition, PSD, VEIC, and EffiBEM. To continue our efforts and provide additional support and training, please join us!

What's Changed

New Features:

  • Update to OpenStudio SDK v3.4.0 and EnergyPlus v22.1.0
  • We have bumped the Qt dependency from 5.15 to 6.3.0. As a result Ubuntu-18.04 is no longer officially supported.
  • This is the first release that includes an Apple M1 (arm64) package
  • Internationalization: translate first tab of the app to English, French, Spanish, Chinese, Greek, Polish, Catalan, Farsi-Persian, Hindi, Japanese, Italian, German, Vietnamese by @jmarrec in #354
  • Option to enable Verbose output to run tab + styled fallback when no socket by @jmarrec in #513
  • filter scene by air loop by @antoine-galataud in #497
  • render 3D scene on demand by @antoine-galataud in #510
  • #479 - Find outdated measures in your local BCL folder compared to Online BCL by @jmarrec in #517
  • Enable loop clone by @eringold in #488

Bug Fixes:

  • Fix #477 - SubSurface types don't line up with many subsurfaces in space by @jmarrec in #515
  • Fix #476 - Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters by @jmarrec in #516
  • Fix #428 - Redo dependent dropdowns for Standards Template / Building Type / Space Type by @jmarrec in #514
  • Fixes #494 - Opening simulation run directory fails by @macumber in #502
  • Allow simulation if run socket cannot be opened by @macumber in #484
  • Workaround for #521: download the missing vcomp140.dll by @jmarrec in #525
  • [#501] DesignHeatRecoveryWaterFlowRate field by @j-lorrey in #532
  • 538 crashes by @macumber in #539

Internal/Developer changes:

New Contributors

Full Changelog: v1.3.1...v1.4.0-rc2

Date Range: 2021-12-16 (v1.3.0) - 2022-06-03:

New Issues: 38

Closed Issues: 32

Accepted Pull Requests: 29

Total Open Issues: 134

Total Open Pull Requests: 3

Click to see details

Closed Issues: 32

  • #110, Hard to see errors generated in ModelToIdf job in App
  • ✔️ #205, Code signing for Windows installer?
  • #230, Remove explicit constructor cppcheck suppression
  • ✔️ #290, No rendering color for Foundation surfaces in Geometry Viewer
  • #353, OpenStudioApplication 1.2.0 - Release Checklist
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #365, Cannot edit plug load densities on Mac after running simulation and looking at results
  • #413, Geometry preview - air loops
  • ✔️ #415, v1.2.1-rc1 Testing: Call for help from the community
  • ✔️ #428, Standards Building Type does not populate correctly
  • ✔️ #435, v1.2.1 Thermal Zone/ Space Tab in Large Models
  • ✔️ #437, No error message for failed simulation with empty spaces
  • #438, Update to Qt 6.2
  • ✔️ #456, OSApp 1.3.0: Release checklist
  • ✔️ #476, Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters
  • ✔️ #477, SubSurface types don't line up with many subsurfaces in space
  • ✔️ #479, Measure updates on BCL don't work
  • ✔️ #480, compiling current version on ubuntu 20.04
  • ✔️ #483, RunView server port is 0, no run feedback
  • #487, Enable 'x2' button to clone Plant Loops in HVAC Systems tab
  • ✔️ #494, Opening simulation run directory fails
  • ✔️ #495, FloorspaceJSON is corrupted on merge
  • #501, Add field DesignHeatRecoveryWaterFlowRate to the ChillerElectricEIR object
  • ✔️ #503, Network access blocked in reporting measures
  • ✔️ #505, Compile for Mac M1 architecture
  • ✔️ #508, Update OSM libraries to SDK 3.4.0
  • #509, Geometry preview - on-demand rendering
  • ✔️ #521, Need to install vcomp140.dll for EnergyPlus on Windows
  • ✔️ #524, Segfault when action (example model / language preferences) tries to restart the app
  • ✔️ #526, Cannot build OSApp in Debug Mode since the move to Qt 6.3.0
  • ✔️ #528, QObject::connect warnings upon startup
  • ✔️ ...

OpenstudioApplication v1.4.0-rc1

05 May 14:33
2ec712e
Compare
Choose a tag to compare
Pre-release

The OpenStudio Coalition is proud to release the first release candidate for OpenStudio Application 1.4.0, which has updates to OpenStudio 3.4.0, EnergyPlus 22.1.0.

As a reminder we have strategic roadmap (here are the high level results) which prioritizes education and outreach to states, utilities, and higher education. All this has been funded by founding OpenStudio Coalition members The Energy Coalition, PSD, VEIC, and EffiBEM. To continue our efforts and provide additional support and training, please join us!

What's Changed

New Features:

  • Update to OpenStudio SDK v3.4.0 and EnergyPlus v22.1.0
  • We have bumped the Qt dependency from 5.15 to 6.3.0. As a result Ubuntu-18.04 is no longer officially supported.
  • This is the first release that includes an Apple M1 (arm64) package
  • Internationalization: translate first tab of the app to English, French, Spanish, Chinese, Greek, Polish, Catalan, Farsi-Persian, Hindi, Japanese, Italian, German, Vietnamese by @jmarrec in #354
  • Option to enable Verbose output to run tab + styled fallback when no socket by @jmarrec in #513
  • filter scene by air loop by @antoine-galataud in #497
  • render 3D scene on demand by @antoine-galataud in #510
  • #479 - Find outdated measures in your local BCL folder compared to Online BCL by @jmarrec in #517
  • Enable loop clone by @eringold in #488

Bug Fixes:

  • Fix #477 - SubSurface types don't line up with many subsurfaces in space by @jmarrec in #515
  • Fix #476 - Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters by @jmarrec in #516
  • Fix #428 - Redo dependent dropdowns for Standards Template / Building Type / Space Type by @jmarrec in #514
  • Fixes #494 - Opening simulation run directory fails by @macumber in #502
  • Allow simulation if run socket cannot be opened by @macumber in #484

Internal/Developer changes:

New Contributors

Full Changelog: v1.3.1...v1.4.0-rc1

Changelog

Date Range: 2021-12-16 (v1.3.0) - 2022-05-05:

New Issues: 25

Closed Issues: 20

Accepted Pull Requests: 21

Total Open Issues: 132

Total Open Pull Requests: 2

Click to see details

Closed Issues: 20

  • #110, Hard to see errors generated in ModelToIdf job in App
  • ✔️ #205, Code signing for Windows installer?
  • ✔️ #290, No rendering color for Foundation surfaces in Geometry Viewer
  • #353, OpenStudioApplication 1.2.0 - Release Checklist
  • ✔️ #365, Cannot edit plug load densities on Mac after running simulation and looking at results
  • #413, Geometry preview - air loops
  • ✔️ #428, Standards Building Type does not populate correctly
  • ✔️ #435, v1.2.1 Thermal Zone/ Space Tab in Large Models
  • ✔️ #437, No error message for failed simulation with empty spaces
  • #438, Update to Qt 6.2
  • ✔️ #456, OSApp 1.3.0: Release checklist
  • ✔️ #476, Apply to selected does not work on ThermalZone Cooling or Heating Size Parameters
  • ✔️ #477, SubSurface types don't line up with many subsurfaces in space
  • ✔️ #479, Measure updates on BCL don't work
  • ✔️ #480, compiling current version on ubuntu 20.04
  • ✔️ #483, RunView server port is 0, no run feedback
  • #487, Enable 'x2' button to clone Plant Loops in HVAC Systems tab
  • ✔️ #494, Opening simulation run directory fails
  • ✔️ #503, Network access blocked in reporting measures
  • #509, Geometry preview - on-demand rendering

Accepted Pull Requests: 21

  • #354, Internationalization: translate first tab of the app to English, French, Spanish, Chinese, Greek, Polish, Catalan, Farsi-Persian, Hindi, Japanese, Italian, German, Vietnamese
  • #461, Upgrade to Qt 6
  • ✔️ #473, Merge to master for 1.3.0
  • ✔️ #484, Allow simulation if run socket cannot be opened
  • ✔️ #488, Enable loop clone
  • ✔️ #490, Increase stack size on Windows CI builds
  • ✔️ #492, Merge to master for 1.3.1
  • ✔️ #496, Additional output to run tab
  • ✔️ #497, filter scene by air loop
  • ✔️ #498, Update conan url
  • ✔️ #499, Bump v340rc2
  • ✔️ #502, Fixes #494
  • ✔️ #504, Consolidate settings into OSWebEnginePage
  • ✔️ #510, render 3D scene on demand
  • ✔️ #511, [#230] Remove explicit constructor cppcheck suppression
  • #513, Option to enable Verbose output to run tab + styled fallback when no socket
  • ✔️ #514, Fix #428 - Redo dependent dropdowns for Standards Template / Building Type / Space Type
  • ✔️ #515, Fix #477 - SubSurface types don't line ...

OpenstudioApplication v1.3.1

06 Mar 00:03
3cc18af
Compare
Choose a tag to compare

The OpenStudio Application version 1.3.1 is a patch update to the 1.3.0 version. There is no corresponding release for the OpenStudio SketchUp Plug-in. The OpenStudio Application 1.3.1 patch fixes the following bugs:

  • Fixes crash in OpenStudio Application GridView for models with a large number of Spaces or ThermalZones on Windows

Changelog

Date Range: 2021-12-16 (v1.3.0) - 2022-03-06:

New Issues: 13

Closed Issues: 2

Accepted Pull Requests: 3

Total Open Issues: 138

Total Open Pull Requests: 6

Click to see details

Closed Issues: 2

  • ✔️ #205, Code signing for Windows installer?
  • ✔️ #456, OSApp 1.3.0: Release checklist

Accepted Pull Requests: 3

  • ✔️ #473, Merge to master for 1.3.0
  • ✔️ #490, Increase stack size on Windows CI builds
  • ✔️ #492, Merge to master for 1.3.1

Total Open Issues: 138 (#130, #110, #132, #111, #112, #142, #113, #143, #158, #133, #134, #172, #135, #136, #162, #139, #174, #157, #166, #175, #138, #167, #137, #121, #176, #114, #144, #152, #171, #141, #115, #140, #122, #116, #164, #170, #165, #151, #154, #148, #117, #150, #123, #169, #153, #124, #160, #155, #125, #156, #105, #159, #161, #120, #127, #118, #119, #128, #129, #145, #146, #147, #168, #19, #42, #78, #101, #96, #104, #179, #199, #206, #213, #217, #224, #230, #234, #238, #239, #253, #254, #262, #263, #271, #272, #273, #278, #279, #280, #284, #289, #290, #293, #298, #300, #314, #322, #332, #335, #336, #337, #338, #353, #357, #365, #371, #377, #380, #381, #389, #396, #400, #410, #411, #413, #415, #416, #417, #423, #428, #435, #437, #438, #472, #475, #476, #477, #478, #479, #480, #481, #482, #483, #485, #486, #487, #489, #491)

Total Open Pull Requests: 6 (#236, #354, #461, #470, #484, #488)

OpenstudioApplication v1.3.0

16 Dec 02:44
5faa91e
Compare
Choose a tag to compare

The OpenStudio Coalition is proud to release the OpenStudio Application 1.3.0, which has updates to OpenStudio 3.3.0, EnergyPlus 9.6.0, and the new GitHub based BCL. This release also has digital code signing for Windows and a variety of bug fixes and new features. We’ve given the OpenStudio Coalition a new brand and logo. We’ve also created a strategic roadmap (here are the high level results) which prioritizes education and outreach to states, utilities, and higher education. All this has been funded by founding OpenStudio Coalition members The Energy Coalition, PSD, VEIC, and EffiBEM. To continue our efforts and provide additional support and training, please join us!

Notable changes in 1.3.0 include:

  • Update to OpenStudio SDK v3.3.0 and EnergyPlus v9.6
  • Update to use the new GitHub based BCL
  • Update to use new OpenStudio Coalition branding and logos
  • Update to sign Windows installer with EV digital certificate
  • Add AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed to library
  • Add CoilCoolingDXVariableSpeed to library
  • Add new adjacency checker to View Model - contributed by Nick Schrader
  • Allow the Apply Measures dialog box to be resized
  • Allow WaterUseConnections to be edited
  • Fix bug that did not allow editing of all fields when using inspector
  • Fix bug that added humidistats to Thermal Zones
  • Fix bug that did not show weather file when first opening a model

What's Changed

New Contributors

Full Changelog: v1.2.1...v1.3.0

Changelog

Date Range: 2021-06-08 (v1.2.0) - 2021-12-16:

New Issues: 54

Closed Issues: 44

Accepted Pull Requests: 44

Total Open Issues: 127

Total Open Pull Requests: 4

Click to see details

Closed Issues: 44

  • #126, Add Exterior Equipment functionality to OS App - Enhancement Request
  • #131, HVAC Tab - There isn't a way to rename water use connections (Bugzilla #913)
  • #173, Allow load library to load an IDF
  • ✔️ #189, Floorspace.js editor is using polygon tool if I select the rectangle tool
  • #266, Ship auxiliary programs together with OpenStudioApplication
  • #301, HVAC library doesn't seem to have CoilCoolingDXVariableSpeed
  • #341, Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #375, Ubuntu 20.04: missing dependencies cannot be installed
  • ✔️ #378, Models with a large number of Spaces or ThermalZones crashes the application
  • ✔️ #379, AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #383, Add icon for ZoneHVACTerminalUnitVariableRefrigerantFlow on AirLoopHVAC:OutdoorAirSystem
  • ✔️ #385, Update ruby action
  • ✔️ #386, Error when opening existing OSM model: Unable to Retrieve OS version 3.1.1 from IddFactory
  • ✔️ #387, GridView is completely blank on Spaces and Thermal Zones tabs for large model
  • ✔️ #392, A space with a hole cannot be drawn in Floorspace JS
  • ✔️ #393, Unable to add Exerior Light Definition
  • ✔️ #394, GBXML import does not show spaces in App
  • #395, GBXML Import reverses floors/ceilings normals and surface types
  • ✔️ #399, Unable to edit Schedule Set name
  • ✔️ #401, SketchUpPluginPolicy not read by inspector
  • ✔️ #403, App 1.2.1 Release
  • #404, Geometry preview - search feature
  • ✔️ #407, Cannot load openstudio.rb from install dir
  • #408, Update to BCL v2
  • ✔️ #412, Unhandled Exception when selecting heating coil in air loop
  • ✔️ #414, OpenStudio Application v1.2.0 Crashes When Accessing Thermal Zones Tab
  • ✔️ #420, Air Boundary Construction field 'Air Exchange Method' is a dropdown, but also kind of acts like a text box: selecting will add a cursor, but trying to type text in the field will crash the app.
  • ✔️ #422, Material gets duplicated when dragging it just a bit on the Construction...

OpenstudioApplication v1.3.0-rc1

12 Dec 17:46
11032f1
Compare
Choose a tag to compare
Pre-release

What's Changed

New Contributors

Full Changelog: v1.2.1...v1.3.0-rc1

Changelog

Date Range: 2021-06-08 (v1.2.0) - 2021-12-12:

New Issues: 53

Closed Issues: 44

Accepted Pull Requests: 43

Total Open Issues: 126

Total Open Pull Requests: 5

Click to see details

Closed Issues: 44

  • #126, Add Exterior Equipment functionality to OS App - Enhancement Request
  • #131, HVAC Tab - There isn't a way to rename water use connections (Bugzilla #913)
  • #173, Allow load library to load an IDF
  • ✔️ #189, Floorspace.js editor is using polygon tool if I select the rectangle tool
  • #266, Ship auxiliary programs together with OpenStudioApplication
  • #301, HVAC library doesn't seem to have CoilCoolingDXVariableSpeed
  • #341, Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #375, Ubuntu 20.04: missing dependencies cannot be installed
  • ✔️ #378, Models with a large number of Spaces or ThermalZones crashes the application
  • ✔️ #379, AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #383, Add icon for ZoneHVACTerminalUnitVariableRefrigerantFlow on AirLoopHVAC:OutdoorAirSystem
  • ✔️ #385, Update ruby action
  • ✔️ #386, Error when opening existing OSM model: Unable to Retrieve OS version 3.1.1 from IddFactory
  • ✔️ #387, GridView is completely blank on Spaces and Thermal Zones tabs for large model
  • ✔️ #392, A space with a hole cannot be drawn in Floorspace JS
  • ✔️ #393, Unable to add Exerior Light Definition
  • ✔️ #394, GBXML import does not show spaces in App
  • #395, GBXML Import reverses floors/ceilings normals and surface types
  • ✔️ #399, Unable to edit Schedule Set name
  • ✔️ #401, SketchUpPluginPolicy not read by inspector
  • ✔️ #403, App 1.2.1 Release
  • #404, Geometry preview - search feature
  • ✔️ #407, Cannot load openstudio.rb from install dir
  • #408, Update to BCL v2
  • ✔️ #412, Unhandled Exception when selecting heating coil in air loop
  • ✔️ #414, OpenStudio Application v1.2.0 Crashes When Accessing Thermal Zones Tab
  • ✔️ #420, Air Boundary Construction field 'Air Exchange Method' is a dropdown, but also kind of acts like a text box: selecting will add a cursor, but trying to type text in the field will crash the app.
  • ✔️ #422, Material gets duplicated when dragging it just a bit on the Construction tab
  • #427, Allow Apply Measures dialog box to be resized/maximized
  • #431, AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed object does not pull through to Library
  • #432, OS:AirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed Controlling Zone or Thermostat Location Missing
  • #433, Some units are displayed weird
  • #434, Name missing from DX:MultiSpeed:StageData
  • #436, Coil:Heating:DX:SingleSpeed missing defrost curve
  • ✔️ #441, Glycol Concentration will only allow entry of Integer
  • ✔️ #442, Heat Pump Water Heater does not eliminate nodes when switching to OutdoorAirOnly
  • #444, Update DesignDay grid view to not use deprecated methods
  • ✔️ #445, Inspector does not all access to all fields
  • ✔️ [#449]( https://github.com/openstudiocoalition/OpenStudioApplic...

OpenstudioApplication v1.2.1

06 Sep 03:05
29888f9
Compare
Choose a tag to compare

The OpenStudio Application version 1.2.1 is a patch update to the 1.2.0 version. There is a corresponding 1.2.1 release for the OpenStudio SketchUp Plug-in. The OpenStudio Application 1.2.1 patch fixes a the following bugs and adds the following new features:

  • Fixes crash in OpenStudio Application GridView for models with a large number of Spaces or ThermalZones
  • Fixes crash in OpenStudio SketchUp Plug-in when using the ThermalZone inspector
  • Adds Exterior Equipment functionality to OpenStudio Application
  • Adds simple search in geometry preview to OpenStudio Application - contributed by Antoine Galataud

Changelog

Date Range: 2021-06-08 (v1.2.0) - 2021-09-06:

New Issues: 34

Closed Issues: 19

Accepted Pull Requests: 18

Total Open Issues: 132

Total Open Pull Requests: 5

Click to see details

Closed Issues: 19

  • #126, Add Exterior Equipment functionality to OS App - Enhancement Request
  • ✔️ #189, Floorspace.js editor is using polygon tool if I select the rectangle tool
  • #341, Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #378, Models with a large number of Spaces or ThermalZones crashes the application
  • ✔️ #379, AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #386, Error when opening existing OSM model: Unable to Retrieve OS version 3.1.1 from IddFactory
  • ✔️ #387, GridView is completely blank on Spaces and Thermal Zones tabs for large model
  • ✔️ #392, A space with a hole cannot be drawn in Floorspace JS
  • ✔️ #393, Unable to add Exerior Light Definition
  • ✔️ #394, GBXML import does not show spaces in App
  • #395, GBXML Import reverses floors/ceilings normals and surface types
  • ✔️ #399, Unable to edit Schedule Set name
  • ✔️ #401, SketchUpPluginPolicy not read by inspector
  • #404, Geometry preview - search feature
  • ✔️ #412, Unhandled Exception when selecting heating coil in air loop
  • ✔️ #414, OpenStudio Application v1.2.0 Crashes When Accessing Thermal Zones Tab
  • ✔️ #420, Air Boundary Construction field 'Air Exchange Method' is a dropdown, but also kind of acts like a text box: selecting will add a cursor, but trying to type text in the field will crash the app.
  • ✔️ #422, Material gets duplicated when dragging it just a bit on the Construction tab

Accepted Pull Requests: 18

  • #344, Fix #341 - Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #376, Merge for 1.2.0
  • ✔️ #382, Completed TS file for Spanish
  • ✔️ #388, Internationalization: Translate to Japanese
  • ✔️ #390, Fix issue with large models
  • ✔️ #391, Update to OS 3.2.1
  • ✔️ #397, Set chromium flags to disable dark mode
  • ✔️ #398, Adds ability to edit exterior lights, fuel equipment, and water equipment
  • ✔️ #402, Fixes #401 SketchUpPluginPolicy not read by inspector
  • ✔️ #405, Implement simple search in geometry preview
  • ✔️ #409, Fix 404
  • ✔️ #418, Install OpenGL libraries on Windows
  • ✔️ #419, Fix #379 - AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #421, Fix #420 - make combobox not editable for Air Boundary Construction field 'Air Exchange Method'
  • ✔️ #425, Fix 422
  • ✔️ #426, Merge for 1.2.1 release
  • ✔️ #429, Set rc2
  • ✔️ #430, Remove pre-release

Total Open Issues: 132 (#130, #131, #110, #132, #111, #112, #142, #113, #143, #158, #133, #134, #173, #172, #135, #136, #162, #139, #174, #157, #166, #175, #138, #167, #137, #121, #176, #114, #144, #152, #171, #141, #115, #140, #122, #116, #164, #170, #165, #151, #154, #148, #117, #150, #123, #169, #153, #124, #160, #155, #125, #156, #105, #159, #161, #120, #127, #118, #119, #128, #129, #145, #146, #147, #168, #19, #42, #78, #101, #96, #104, #179, #199, #205, #206, #213, #217, #224, #230, #234, #238, #239, #253, #254, #262, #263, #266, #271, #272, #273, #278, #279, #280, #284, #289, #290, #293, #298, #300, #301, #314, #322, #332, #335, #336, #337, #338, #353, #357, #365, #371, #375, #377, #380, #381, #383, #385, #389, #396, #400, #403, #407, #408, #410, #411, #413, #415, #416, #417, #423, #427, #428)

Total Open Pull Requests: 5 (#236, #354, #384, #406, #424)

OpenstudioApplication v1.2.1-rc2

04 Sep 02:51
222b639
Compare
Choose a tag to compare
Pre-release

Changelog

Date Range: 2021-06-08 (v1.2.0) - 2021-09-04:

New Issues: 34

Closed Issues: 19

Accepted Pull Requests: 17

Total Open Issues: 132

Total Open Pull Requests: 5

Click to see details

Closed Issues: 19

  • #126, Add Exterior Equipment functionality to OS App - Enhancement Request
  • ✔️ #189, Floorspace.js editor is using polygon tool if I select the rectangle tool
  • #341, Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #358, Cannot run geometry editor on systems without OpenGL 2.0
  • ✔️ #378, Models with a large number of Spaces or ThermalZones crashes the application
  • ✔️ #379, AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #386, Error when opening existing OSM model: Unable to Retrieve OS version 3.1.1 from IddFactory
  • ✔️ #387, GridView is completely blank on Spaces and Thermal Zones tabs for large model
  • ✔️ #392, A space with a hole cannot be drawn in Floorspace JS
  • ✔️ #393, Unable to add Exerior Light Definition
  • ✔️ #394, GBXML import does not show spaces in App
  • #395, GBXML Import reverses floors/ceilings normals and surface types
  • ✔️ #399, Unable to edit Schedule Set name
  • ✔️ #401, SketchUpPluginPolicy not read by inspector
  • #404, Geometry preview - search feature
  • ✔️ #412, Unhandled Exception when selecting heating coil in air loop
  • ✔️ #414, OpenStudio Application v1.2.0 Crashes When Accessing Thermal Zones Tab
  • ✔️ #420, Air Boundary Construction field 'Air Exchange Method' is a dropdown, but also kind of acts like a text box: selecting will add a cursor, but trying to type text in the field will crash the app.
  • ✔️ #422, Material gets duplicated when dragging it just a bit on the Construction tab

Accepted Pull Requests: 17

  • #344, Fix #341 - Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #376, Merge for 1.2.0
  • ✔️ #382, Completed TS file for Spanish
  • ✔️ #388, Internationalization: Translate to Japanese
  • ✔️ #390, Fix issue with large models
  • ✔️ #391, Update to OS 3.2.1
  • ✔️ #397, Set chromium flags to disable dark mode
  • ✔️ #398, Adds ability to edit exterior lights, fuel equipment, and water equipment
  • ✔️ #402, Fixes #401 SketchUpPluginPolicy not read by inspector
  • ✔️ #405, Implement simple search in geometry preview
  • ✔️ #409, Fix 404
  • ✔️ #418, Install OpenGL libraries on Windows
  • ✔️ #419, Fix #379 - AirLoopHVAC Control Tab resets some economizer selections
  • ✔️ #421, Fix #420 - make combobox not editable for Air Boundary Construction field 'Air Exchange Method'
  • ✔️ #425, Fix 422
  • ✔️ #426, Merge for 1.2.1 release
  • ✔️ #429, Set rc2

Total Open Issues: 132 (#130, #131, #110, #132, #111, #112, #142, #113, #143, #158, #133, #134, #173, #172, #135, #136, #162, #139, #174, #157, #166, #175, #138, #167, #137, #121, #176, #114, #144, #152, #171, #141, #115, #140, #122, #116, #164, #170, #165, #151, #154, #148, #117, #150, #123, #169, #153, #124, #160, #155, #125, #156, #105, #159, #161, #120, #127, #118, #119, #128, #129, #145, #146, #147, #168, #19, #42, #78, #101, #96, #104, #179, #199, #205, #206, #213, #217, #224, #230, #234, #238, #239, #253, #254, #262, #263, #266, #271, #272, #273, #278, #279, #280, #284, #289, #290, #293, #298, #300, #301, #314, #322, #332, #335, #336, #337, #338, #353, #357, #365, #371, #375, #377, #380, #381, #383, #385, #389, #396, #400, #403, #407, #408, #410, #411, #413, #415, #416, #417, #423, #427, #428)

Total Open Pull Requests: 5 (#236, #354, #384, #406, #424)

OpenstudioApplication v1.2.1-rc1

19 Aug 07:49
Compare
Choose a tag to compare
Pre-release

This is the first release candidate for the 1.2.1 release.

Changelog

Date Range: 2021-06-08 (v1.2.0) - 2021-08-19:

New Issues: 24

Closed Issues: 13

Accepted Pull Requests: 11

Total Open Issues: 128

Total Open Pull Requests: 4

Click to see details

Closed Issues: 13

  • #126, Add Exterior Equipment functionality to OS App - Enhancement Request
  • ✔️ #189, Floorspace.js editor is using polygon tool if I select the rectangle tool
  • #341, Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #378, Models with a large number of Spaces or ThermalZones crashes the application
  • ✔️ #386, Error when opening existing OSM model: Unable to Retrieve OS version 3.1.1 from IddFactory
  • ✔️ #387, GridView is completely blank on Spaces and Thermal Zones tabs for large model
  • ✔️ #392, A space with a hole cannot be drawn in Floorspace JS
  • ✔️ #393, Unable to add Exerior Light Definition
  • ✔️ #394, GBXML import does not show spaces in App
  • #395, GBXML Import reverses floors/ceilings normals and surface types
  • ✔️ #399, Unable to edit Schedule Set name
  • ✔️ #401, SketchUpPluginPolicy not read by inspector
  • #404, Geometry preview - search feature

Accepted Pull Requests: 11

  • #344, Fix #341 - Add functionality to load the openstudio::model::exampleModel() directly in the UI
  • ✔️ #376, Merge for 1.2.0
  • ✔️ #382, Completed TS file for Spanish
  • ✔️ #388, Internationalization: Translate to Japanese
  • ✔️ #390, Fix issue with large models
  • ✔️ #391, Update to OS 3.2.1
  • ✔️ #397, Set chromium flags to disable dark mode
  • ✔️ #398, Adds ability to edit exterior lights, fuel equipment, and water equipment
  • ✔️ #402, Fixes #401 SketchUpPluginPolicy not read by inspector
  • ✔️ #405, Implement simple search in geometry preview
  • ✔️ #409, Fix 404

Total Open Issues: 128 (#130, #131, #110, #132, #111, #112, #142, #113, #143, #158, #133, #134, #173, #172, #135, #136, #162, #139, #174, #157, #166, #175, #138, #167, #137, #121, #176, #114, #144, #152, #171, #141, #115, #140, #122, #116, #164, #170, #165, #151, #154, #148, #117, #150, #123, #169, #153, #124, #160, #155, #125, #156, #105, #159, #161, #120, #127, #118, #119, #128, #129, #145, #146, #147, #168, #19, #42, #78, #101, #96, #104, #179, #199, #205, #206, #213, #217, #224, #230, #234, #238, #239, #253, #254, #262, #263, #266, #271, #272, #273, #278, #279, #280, #284, #289, #290, #293, #298, #300, #301, #314, #322, #332, #335, #336, #337, #338, #353, #357, #358, #365, #371, #375, #377, #379, #380, #381, #383, #385, #389, #396, #400, #403, #407, #408, #410, #411, #412)

Total Open Pull Requests: 4 (#236, #354, #384, #406)

OpenstudioApplication v1.2.0

08 Jun 14:57
72d719f
Compare
Choose a tag to compare

OpenStudio Application Version 1.2.0 and OpenStudio SketchUp Plug-in Version 1.2.0

Release Notes - 2021-06-08

The OpenStudio Coalition is proud to announce the releases of OpenStudio Application v1.2.0 and OpenStudio SketchUp Plug-in v1.2.0. These releases are based on OpenStudio SDK v3.2.0 which uses EnergyPlus v9.5.0.

Overview

Following an important announcement related to future development of the OpenStudio Application released in September 2019 (A Shift in BTO’s BEM Strategy: A New Future for the OpenStudio Application), this release marks the second major release of the OpenStudio Application and OpenStudio SketchUp Plug-in by the OpenStudio Coalition.
Going forward, the OpenStudio SDK will continue to be distributed and released by NREL and U.S. DOE two times per year, in April and October. The OpenStudio SDK includes the C++ SDK, Ruby API, Command Line Interface (CLI), OpenStudio Standards, and integrated EnergyPlus and Radiance packages.

The OpenStudio Coalition will be distributing and releasing new versions of the OpenStudio Application and OpenStudio SketchUp Plug-in as new versions of the OpenStudio SDK are released. Development of the OpenStudio Application has moved to openstudiocoalition/OpenStudioApplication and development of the OpenStudio SketchUp Plug-in has moved to openstudiocoalition/openstudio-sketchup-plugin.

OpenStudio Application Version 1.2.0 and OpenStudio SketchUp Plug-in Version 1.2.0 are the second major releases of these programs distributed by the OpenStudio Coalition. Notable changes include:

  • Update to OpenStudio SDK v3.2.0 and EnergyPlus v9.5.0
  • Update to Ruby 2.7.2 for compatibility with SketchUp 2021
    • OpenStudio Application v1.2.0 is compatible with SketchUp 2021
    • OpenStudio Application v1.1.0 is compatible with SketchUp 2019-2020
  • Improvements to GridView performance for larger models
    • Displaying the Surfaces tab for example is now 3 times faster
  • Add support for ZoneHVAC:CoolingPanel:RadiantConvective:Water, Humidifier:Stream:Gas, Fan:ComponentModel, Output:Diagnostics, and Output:Table:SummaryReports objects
  • Fix installer and geometry tab on Ubuntu
  • Add ability to start app on specific tab using the OPENSTUDIO_APPLICATION_START_TAB_INDEX environment variable (Feature supported by Ladybug Tools)
  • Updated FloorspaceJS to latest version, and ThreeJS to version r98
  • Update to supported JFrog and NREL conan remotes

Note that PAT and DView are not included in either the SDK or Application installers. You will need to install PAT separately which is distributed on the OpenStudio-PAT GitHub page and DView at the Dview home page.

Installation Notes

OpenStudio Application v1.2.0 is supported on 64-bit Windows 7 – 10, OS X 10.12 – 10.15, Ubuntu 18.04, and Ubuntu 20.04. The OpenStudio SketchUp Plug-in v1.2.0 requires OpenStudio Application v1.2.0 and SketchUp 2021.

Refer to the OpenStudio Application Compatibility Matrix and the OpenStudio SketchUp Plug-in Compatibility Matrix for more information.

Installation Steps

  • Download and run the correct OpenStudio Application v1.2.0 installer for your platform. Select components for installation. Note that OpenStudio Application is a standalone app and does not require you to install OpenStudio SDK.
  • (Optional) Download the OpenStudio SketchUp Plug-in v1.2.0 RBZ package. Launch SketchUp 2021 and install the RBZ package.
  • (Optional) Setup a Building Component Library (BCL) account to access online building components and measures.

For help with common installation problems and more detailed instructions please visit, https://openstudiocoalition.org/getting_started/getting_started/.

Changelog

Date Range: 2020-10-24 (v1.1.0) - 2021-06-08:

New Issues: 79

Closed Issues: 73

Accepted Pull Requests: 39

Total Open Issues: 117

Total Open Pull Requests: 3

Click to see details

Closed Issues: 73

  • #11, Use pre-built Qt on all platforms
  • ✔️ #71, Windows: Machine restart required to completely uninstall app
  • ✔️ #85, Bool button doesn't display on Apply Measure Now measure argument
  • ✔️ #95, Geometry Editor not working on Ubuntu
  • ✔️ #108, OS App v1.0.0 "Measures" tab does not properly render Reporting Measure Arguments
  • ✔️ #149, Improve grid views performance for big models
  • ✔️ #178, Find Measures doesn't show all BCL Measures
  • ✔️ #181, While Running the simulation on Openstudio 3.0.1 version I am getting this error- ERROR: Input file must have IDF, IMF, or epJSON extension.
  • ✔️ #188, Empty nodes are created whenever I try to drag an equipment from library and that equipment is not supported.
  • ✔️ #190, Measures tab doesn't show all measures
  • ✔️ #200, 1.1.0 OpenStudio Application Release
  • #202, Wrap new Output Diagnostic objects
  • ✔️ #207, Not able to Draw more than 11 Windows using floorspace.js App version
  • #210, Add AirLoopHVAC "design return airflow fraction" to the OpenStudioApplication and adjust OpenStudioPolicy to hide splitter/mixer
  • ✔️ #215, DualDuct Thermal Zone Assignment on Splitter Not Working
  • ✔️ #219, VRF from hvac_library makes E+ Fatal Out
  • ✔️ #220, Crashes when using OpenStudio Results and SI reporting
  • ✔️ #223, Extra surfaces made resulting in increase in simulation timing
  • ✔️ #228, Failed to partition Polygon and change in the intersection area after merging the json file with osm
  • ✔️ #231, Envelope and Internal load breakdown measure breaking while running the simulation
  • #232, Update OpenStudio Standards Library OSMs
  • ✔️ #233, 3D viewer causing OS to crash
  • ✔️ #249, The image of AirLoopHVAC:OutdoorAirSystem is incorrect
  • ✔️ #251, Fix build warnings
  • ✔️ #252, OpenStudio Application does not find EnergyPlus
  • ✔️ #261, Application crashes when deleting HVAC loop
  • ✔️ #264, Zooming in FloorSpaceJS zooms UI in addition to plan space
  • ✔️ #267, Missing fields for some measures in the measure tab
  • ✔️ #268, Can't set "Outdoor Carbon Dioxide Schedule Name"
  • ✔️ #269, My Model list does n...