[Electron] AT commands with long responses not completing #1138

Closed
technobly opened this issue Oct 13, 2016 · 0 comments · Fixed by #1140

Comments

@technobly
Copy link
Member

commented Oct 13, 2016

Please refer to this community post: https://community.particle.io/t/electron-serious-issue-with-ublox-at-communication-for-retrieving-large-result-sets/22131

Tracking internally: FIRM-333, AE-193

// List all available AT commands with AT+CLAC
Use the AT command mode of the troubleshooting app to send AT+CLAC ... wait a bit and send AT to get the result of the buffer.
https://gist.github.com/technobly/5ff967632eeaab19128d84c805f20f10

Or with debugging enabled, try adding this to the end of MDMParser:_powerOn() to have more direct control over URCs:

    // List all available AT commands with AT+CLAC
    sendFormated("AT+CLAC\r\n");
    if(RESP_OK != waitFinalResp(NULL,NULL,60000);
        goto failure;

Response should be seen in the log output.

Suspected issue with electronserialpipe_hal buffer size or hardware interaction with modem USART.


Completeness:

  • Minimum test case added
  • Device, system and user firmware versions stated (all)
  • Particle confirmed

@technobly technobly added the bug label Oct 13, 2016

@avtolstoy avtolstoy self-assigned this Oct 16, 2016

avtolstoy added a commit that referenced this issue Oct 16, 2016

@technobly technobly added this to the 0.7.x milestone Oct 17, 2016

@technobly technobly modified the milestones: 0.7.x, 0.6.1 Nov 29, 2016