Generating detailed summary of the adapter, it may take a while to complete. Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = LSI 2108 MegaRAID Serial Number = FW-ACJFPFEAARBWA Current Controller Date/Time = 12/24/2022, 10:33:04 Current System Date/time = 12/24/2022, 10:33:22 SAS Address = 5003048014579200 PCI Address = 00:82:00:00 Mfg Date = 00/00/00 Rework Date = 00/00/00 Revision No = Version : ======= Firmware Package Build = 12.15.0-0239 Firmware Version = 2.130.403-4660 Bios Version = 3.30.02.2_4.16.08.00_0x06060A05 Preboot CLI Version = 04.04-020:#%00009 WebBIOS Version = 6.0-54-e_50-Rel NVDATA Version = 2.09.03-0058 Boot Block Version = 2.02.00.00-0000 Bootloader Version = 09.250.01.219 Driver Name = megaraid_sas Driver Version = 07.717.02.00-rc1 Bus : === Vendor Id = 0x1000 Device Id = 0x79 SubVendor Id = 0x15D9 SubDevice Id = 0x700 Host Interface = PCI-E Device Interface = SAS-6G Bus Number = 130 Device Number = 0 Function Number = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Optimal Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = 44 Support PD Firmware Download = No Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No Bios was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = Yes Cluster Support = No BBU = Yes Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes FW and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd & Even Drive count in RAID1E = No Support Security = No Support Config Page Model = Yes Support the OCE without adding drives = Yes Support EKM = No Snapshot Enabled = No Support PFK = Yes Support PI = No Support Ld BBM Info = No Support Shield State = No Block SSD Write Disk Cache Change = No Support Suspend Resume BG ops = No Support Emergency Spares = Yes Support Set Link Speed = No Support Boot Time PFK Change = No Support JBOD = No Disable Online PFK Change = No Support Perf Tuning = No Support SSD PatrolRead = Yes Real Time Scheduler = Yes Support Reset Now = Yes Support Emulated Drives = Yes Headless Mode = Yes Dedicated HotSpares Limited = No Point In Time Progress = No Extended LD = No Boot Volume Supported = No Support Uneven span = No Support Config Auto Balance = No Support Maintenance Mode = No Support Diagnostic results = No Support Ext Enclosure = No Support Sesmonitoring = No Support SecurityonJBOD = No Support ForceFlash = No Support DisableImmediateIO = Yes Support LargeIOSupport = No Support DrvActivityLEDSetting = Yes Support FlushWriteVerify = No Support CPLDUpdate = No Support ForceTo512e = No Support discardCacheDuringLDDelete = No Support JBOD Write cache = No Support Large QD Support = No Support SRIOV Options = No Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = No Deny Locate = No Support Power State = Yes Set Power State For Cfg = No Support T10 Power State = No Support Temperature = Yes NCQ = No Support Max Rate SATA = No Support Degraded Media = No Support Parallel FW Update = No Support Drive Crypto Erase = No Supported VD Operations : ======================= Read Policy = Yes Write Policy = Yes IO Policy = Yes Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = Yes Support FastPath = No Performance Metrics = Yes Power Savings = No Support Powersave Max With Cache = No Support Breakmirror = No Support SSC WriteBack = No Support SSC Association = Yes Support VD Hide = No Support VD Cachebypass = No Support VD discardCacheDuringLDDelete = No Advanced Software Option : ======================== ------------------------------------- Adv S/W Opt Time Remaining Mode ------------------------------------- MegaRAID RAID6 Unlimited - MegaRAID RAID5 Unlimited - ------------------------------------- Safe ID = JJ17M5BUPUQ81RDKM9HGF7IMB81U6ME2RUI7432Z HwCfg : ===== ChipRevision = B4 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 8 BBU = Present Alarm = On Serial Debugger = Present NVRAM Size = 32KB Flash Size = 8MB On Board Memory Size = 512MB CacheVault Flash Size = NA TPM = Absent Upgrade Key = Absent On Board Expander = Absent Temperature Sensor for ROC = Absent Temperature Sensor for Controller = Absent Upgradable CPLD = Absent Current Size of CacheCade (GB) = 0 Current Size of FW Cache (MB) = 346 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 4s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = 1GB Auto Rebuild = On Battery Warning = On ECC Bucket Size = 15 ECC Bucket Leak Rate (hrs) = 24 Restore HotSpare on Insertion = Off Expose Enclosure Devices = On Maintain PD Fail History = Off Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = On Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = No Enable Web BIOS = Yes Enable PreBoot CLI = Yes Enable BIOS = Yes Max Drives to Spinup at One Time = 4 Maximum number of direct attached drives to spin up in 1 min = 120 Delay Among Spinup Groups (sec) = 2 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 64 KB Write Policy = WB Read Policy = Adaptive Cache When BBU Bad = On Cached IO = On VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = 1 GB ZCR Config = Unknown Max Chained Enclosures = 16 Direct PD Mapping = Yes Restore Hot Spare on Insertion = No Expose Enclosure Devices = Yes Maintain PD Fail History = No Zero Based Enclosure Enumeration = No Disable Puncturing = No EnableLDBBM = Yes DisableHII = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = No LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = No Disable Online Controller Reset = No Treat Single span R1E as R10 = No Power Saving option = Enabled TTY Log In Flash = No Auto Enhanced Import = No BreakMirror RAID Support = No Disable Join Mirror = No Enable Shield State = No Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA Boot Volume Supported = NO RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Enable JBOD = No Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Allowed Mix of SAS/SATA of SSD type in VD = Allowed Mix of SSD/HDD in VD = Allowed SAS Disable = No Max Arms Per VD = 32 Max Spans Per VD = 8 Max Arrays = 128 Max VD per array = 16 Max Number of VDs = 64 Max Parallel Commands = 1008 Max SGE Count = 80 Max Data Transfer Size = 8192 sectors Max Strips PerIO = 42 Max Configurable CacheCade Size(GB) = 0 Max Transportable DGs = 0 Min Strip Size = 8 KB Max Strip Size = 1.0 MB Scheduled Tasks : =============== Consistency Check Reoccurrence = 672 hrs Next Consistency check launch = 12/24/2022, 04:00:00 Patrol Read Reoccurrence = 672 hrs Next Patrol Read launch = 12/25/2022, 04:00:00 Battery learn Reoccurrence = 672 hrs Next Battery Learn = 12/24/2022, 04:00:00 OEMID = LSI Drive Groups = 1 TOPOLOGY : ======== ---------------------------------------------------------------------------- DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR ---------------------------------------------------------------------------- 0 - - - - RAID5 Optl Y 10.913 TB dflt N N none N N 0 0 - - - RAID5 Optl Y 10.913 TB dflt N N none N N 0 0 0 252:0 0 DRIVE Onln N 2.727 TB dflt N N none - N 0 0 1 252:1 1 DRIVE Onln N 2.727 TB dflt N N none - N 0 0 2 252:2 2 DRIVE Onln N 2.727 TB dflt N N none - N 0 0 3 252:3 3 DRIVE Onln N 2.727 TB dflt N N none - N 0 0 4 252:4 4 DRIVE Onln N 2.727 TB dflt N N none - N ---------------------------------------------------------------------------- DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present TR=Transport Ready Virtual Drives = 1 VD LIST : ======= -------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name -------------------------------------------------------------- 0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB -------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 5 PD LIST : ======= ----------------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ----------------------------------------------------------------------------------- 252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - ----------------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded BBU_Info : ======== ----------------------------------------------------------------------- Model State RetentionTime Temp Mode MfgDate Next Learn ----------------------------------------------------------------------- iBBU08 Optimal 48 hours + 47C 1 2012/08/22 2022/13/24 04:00:00 ----------------------------------------------------------------------- Mode 1: 12+ Hrs retention with a transparent learn cycle and best service life. Controller = 0 Status = Success Description = None /c0/v0 : ====== -------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name -------------------------------------------------------------- 0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB -------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency PDs for VD 0 : ============ ----------------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ----------------------------------------------------------------------------------- 252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - 252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U - ----------------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded VD0 Properties : ============== Strip Size = 64 KB Number of Blocks = 23437492224 VD has Emulated PD = No Span Depth = 1 Number of Drives Per Span = 5 Write Cache(initial setting) = WriteBack Disk Cache Policy = Disk's Default Encryption = None Data Protection = None Active Operations = Consistency Check (95%) Exposed to OS = Yes Creation Date = 29-04-2021 Creation Time = 10:53:28 AM Emulation type = default Is LD Ready for OS Requests = Yes SCSI NAA Id = 6003048014579200281d4ca843bb0950