Skip to content

Unity Sample APP intended to show a practical integration of PLUX devices with the Unity environment, encompassing functionalities such as: the search of compatible Bluetooth devices and also the start/stop of a real-time acquisition.

pluxbiosignals/unity-sample

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

43 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

PLUX Unity API [Windows] | Sample APP

The Sample APP contained inside this repository provides a practical and intuitive resource to explore the integration of the signal acquisition devices commercialized by PLUX (biosignalsplux, biosignalsplux Hybrid-8...) with the powerful development environment of Unity.

Some questions can be enlightened, such as:

  • How PLUX acquisition systems can be searched and found on the user's computer?
  • How to pair a computer with a PLUX device?
  • How to customize signal acquisition parameters, such as sampling rate and Analog to Digital Converter (ADC) resolution?
  • How to start a real-time acquisition?
  • How to collect and store the acquired real-time physiological data?
  • How to stop the real-time acquisition?

Supported Platforms

  • Microsoft Windows [32 and 64 bits]

Tested Script Runtime Versions

  • Microsoft .NET Framework 3.5
  • Microsoft .NET Framework 4.0

Recommended Unity Version

  • Unity 2021.3.5f1

Limitations

  • Currently, the Lite version of the Sample APP supports the following devices:
  • biosignalsplux
  • biosignalsplux Hybrid-8
  • biosignalsplux Solo
  • muscleBAN
  • BITalino (r)evolution

Auxiliary Packages

UnityThreadHelper | https://assetstore.unity.com/packages/tools/unitythreadhelper-3847

How to Use It

The provided project folder is a ready to use Unity solution, you simply need to access the cloned folder through Unity interface.

On the following animation we can quickly show the main functionalities of our Sample APP:

sample-app-animation.gif

How to Easily Integrate the API in your Unity Project?

  1. Copy the plux_unity_interface.dll to the Plugins folder of your Unity project. The location of this file will depend on the desired Operating System Architecture (x86 or x86_64): plux-api-unity-sample/Assets/Plugins/x86/plux_unity_interface.dll [32 bits] or plux-api-unity-sample/Assets/Plugins/x86_64/plux_unity_interface.dll [64 bits]
  2. Copy the PluxDeviceManager folder (a C# interface to PLUX API) to the Scripts folder of your Unity project. In this case the directory location is: plux-api-unity-sample/Assets/Scripts/PluxDeviceManager

WARNING

While initialising PluxDeviceManager instance/object it will be necessary to specify some callbacks responsible for dealing with the asynchronous results returned by the PLUX API, namely:

Scanning Results

public void ScanResults(List<string> listDevices)

This callback receives the list of devices (listDevices) found during the Bluetooth scan triggered by the PluxDeviceManager.GetDetectableDevicesUnity method.

Connection Status

public void ConnectionDone(bool connectionStatus)

The current callback returns the result of the Bluetooth connection attempt (made by the PluxDeviceManager.PluxDev method), stating if the connection was established with success (connectionStatus=true) or not (connectionStatus=false).

Acquisition Started Status

public void AcquisitionStarted(bool acquisitionStatus, bool exceptionRaised, string exceptionMessage)

After triggering the start of a real-time data acquisition (with the methods highlighted below), this callback returns a state parameter (acquisitionStatus) that states if the acquisition was started with success (acquisitionStatus=true) or not (acquisitionStatus=false).

On the other hand, the exceptionRaised boolean flag identifies if this event was raised due to an exception raised in the PLUX API (exceptionRaised=true) and which was the description linked with the exception (exceptionMessage).

On Data Received

public void OnDataReceived(int nSeq, int[] data)

This nuclear callback is responsible for receiving the packages of data streamed by a PLUX device, containing a sequential number identifying the package number (nSeq) and the package of RAW data (data) with the following format: [sample_first_active_channel, sample_second_active_channel,...]

On Event Detected

public void OnEventDetected(PluxDeviceManager.PluxEvent pluxEvent)

The current callback receives a set of events that may be raised by the PLUX API during a real-time data acquisition, namely:

  • PluxDeviceManager.PluxDisconnectEvent
    • <PluxDisconnectReason> reason This argument contains the reason (Timeout | ButtonPressed | BatDischarged) that triggered this event.
  • PluxDeviceManager.PluxDigInUpdateEvent
    • <PluxDeviceManager.PluxClock> timestamp Timestamp object containing relevant info about the moment when the event was triggered.
      • <ClockSources> source This argument contains the type of a timestamp object stating when the event was raised (None | RTC | FrameCount | Bluetooth) that triggered this event.
      • <int> value The timestamp value linked with the moment when the event was raised.
    • <int> channel Number of the digital channel whose state was changed.
    • <bool> state New state of the digital channel.

On Exception Raised

public void OnExceptionRaised(int exceptionCode, string exceptionDescription)

In this callback unhandled API exceptions are communicated to the Unity APP, presenting an unique identifier code (exceptionCode) and a string with the description about the exception (exceptionDescription).

After the previous two steps, you will be fully prepared to expand your Unity project and include some interesting functionalities through the use of PLUX signal acquisition devices.

For this purpose, you simply need to invoke the available Methods.

Unity API

Methods

PluxDev

Method used to establish a connection between PLUX devices and computer. Behaves like an object constructor.

void PluxDev(string macAddress)

Description

With PluxDev method it is possible to establish a Bluetooth connection between a computer and a PLUX Device. To ensure a successful pairing, the user only need to check the device mac-address (attached to the BITalino board, biosignalsplux hub...). This mac-address should be inserted in a string format with the following structure: "00:07:80:4D:2E:AD" (6 pairs of characters separated by ":").

Parameters

  • macAddress string: Device unique identifier, consisting in a string formed by 6 pairs of characters separated by ":" symbol (total of 17 characters).

DisconnectPluxDev

Opposing to PluxDev, this method is very useful when you want to safely cut the connection between PLUX devices and computer. Behaves like an object destructor.

void DisconnectPluxDev()

Description

Through DisconnectPluxDev method the established connection between a PLUX device and a personal computer can be securely closed. If a real-time acquisition is yet being executed, a stop command is automatically sent, ensuring the end of communication loop. Internally, the object created with PluxDev is destroyed after invoking DisconnectPluxDev.

Parameters

Function without input parameters

StartAcquisitionUnity

Class method used to start a real-time acquisition at the device paired with the computer through PluxDev method.

void StartAcquisitionUnity(int samplingRate, List<int> listChannels, int resolution)

Description

The current API version supports real-time acquisitions with analogical sensors, however, to communicate with computer the PLUX device needs to execute an Analogical to Digital Conversion (ADC), through data sampling. Taking ADC stage into consideration, while starting a real-time acquisition, selecting a specific sampling rate and resolution is extremely easy through the inputs of StartAcquisitionUnity.

Parameters

  • samplingRate int: Desired sampling rate that will be used during the data acquisition stage. The used units are in Hz (samples/s).
  • listChannels List<int>: A list where it can be specified the active channels. Each entry contains a port number of an active channel.
  • resolution int: Analog-to-Digital Converter (ADC) resolution. This parameter defines how precise are the digital sampled values when compared with the ideal real case scenario.

StartAcquisitionBySourcesUnity

Class method used to start a real-time acquisition at the device paired with the computer through PluxDev method.

void void StartAcquisitionBySourcesUnity(int samplingRate, PluxSource[] sourcesArray)

Description

The current methods is responsible to trigger real-time acquisitions with analogical AND digital sensors, through the creation of an array containing PluxSource elements. Each source is responsible for the configuration of a specific port of the PLUX device being used.

To create a new PluxSource the following constructor must be used:

// port -> Source port (1...8 for analog ports). Default value is zero.
// freqDivisor -> Source frequency divisor from acquisition base frequency (>= 1). Default value is 1.
// nBits -> Source sampling resolution in bits (8 or 16). Default value is 16.
// chMask -> Bitmask of source channels to sample (bit 0 is channel 0, etc). Default value is 1 (channel 0 
//           only). For a digital port if chMask=0x0F it means that channels 1-4 are active (0000 1111).
public PluxSource(int port, int freqDivisor, int nBits, int chMask)

Some practical examples are presented in the following code blocks:

[bisignalsplux]

// Starting a real-time acquisition from:
// >>> biosignalsplux [CH1 and CH8 active | resolution=16 bits]
List<PluxDeviceManager.PluxSource> pluxSources = new List<PluxDeviceManager.PluxSource>();
pluxSources.Add(new PluxDeviceManager.PluxSource(1, 1, 16, 0x01));
pluxSources.Add(new PluxDeviceManager.PluxSource(8, 1, 16, 0x01));

// Being PluxDevManager the instance of our PluxDeviceManager class.
// sampling rate = 1000 Hz
PluxDevManager.StartAcquisitionBySourcesUnity(1000, pluxSources.ToArray());

[bisignalsplux Hybrid-8]

// Starting a real-time acquisition from:
// >>> biosignalsplux Hybrid-8 [CH1, CH2 and CH8 active | resolution=16 bits]
// >>> CH1 and CH2 will be connected to a digital sensor (fNIRS, SpO2,...).
List<PluxDeviceManager.PluxSource> pluxSources = new List<PluxDeviceManager.PluxSource>();

// Add the sources of the digital channels (CH1 and CH2).
pluxSources.Add(new PluxDeviceManager.PluxSource(1, 1, 16, 0x03));
pluxSources.Add(new PluxDeviceManager.PluxSource(2, 1, 16, 0x03));

// Being PluxDevManager the instance of our PluxDeviceManager class.
// Define the LED Intensities of both sensors as: RED=80% and INFRARED=40%
int[] ledIntensities = new int[2] {80, 40};
PluxDevManager.SetParameter(1, 0x03, ledIntensities);
PluxDevManager.SetParameter(2, 0x03, ledIntensities);

// Add the source of the analog channel (CH8).
pluxSources.Add(new PluxDeviceManager.PluxSource(8, 1, 16, 0x01));

// Being PluxDevManager the instance of our PluxDeviceManager class.
// Start a real-time acquisition at a 300 Hz sampling rate.
PluxDevManager.StartAcquisitionBySourcesUnity(300, pluxSources.ToArray());

[fNIRS Explorer]

// Starting a real-time acquisition from:
// >>> fNIRS Explorer [Full set of SpO2 and Accelerometer channels]
List<PluxDeviceManager.PluxSource> pluxSources = new List<PluxDeviceManager.PluxSource>();
// [SpO2 Port (4 channels - 0x0F > 0000 1111)]
pluxSources.Add(new PluxDeviceManager.PluxSource(9, 1, 16, 0x0F));

// [ACC Port (3 channels - 0x07 > 0000 0111)]
pluxSources.Add(new PluxDeviceManager.PluxSource(11, 1, 16, 0x07));

// Being PluxDevManager the instance of our PluxDeviceManager class.
// sampling rate = 1000 Hz
PluxDevManager.StartAcquisitionBySourcesUnity(1000, pluxSources.ToArray());

Parameters

  • samplingRate int: Desired sampling rate that will be used during the data acquisition stage. The used units are in Hz (samples/s).
  • sourcesArray PluxSource[]: A list of PluxSource elements that define which channels are active and its internal configurations, namely the resolution and frequency divisor.

StartAcquisitionByNbrUnity

Class method used to start a real-time acquisition at the device paired with PluxDev method.

void StartAcquisitionByNbrUnity(int samplingRate, int numberOfChannel, int resolution)

Description

The current API version supports real-time acquisitions with analogical sensors, however, to communicate with computer the PLUX device needs to execute an Analogical to Digital Conversion (ADC), through data sampling. Taking ADC stage into consideration, while starting a real-time acquisition, selecting a specific sampling rate and resolution is extremely easy through the inputs of StartAcquisitionByNbrUnity. The main difference of this function in comparison with StartAcquisitionUnity is the numberOfChannels argument, so, instead of specifying a list of active channels you can simply identify the number of channels to be used during the data collection procedure. Channels are activated in a sequential way, so, if numberOfChannels is equal to 3 it means that ports 1 to 3 will collect data.

Parameters

  • samplingRate int: Desired sampling rate that will be used during the data acquisition stage. The used units are in Hz (samples/s).
  • numberOfChannels int: Number of the active channel that will be used during data acquisition. With BITalino this value should be between 1 and 6 while for biosignalsplux it is possible to collect data from up to 8 channels (simultaneously).
  • resolution int: Analog-to-Digital Converter (ADC) resolution. This parameter defines how precise are the digital sampled values when compared with the ideal real case scenario.

StartAcquisitionMuscleBanUnity

Class method used to start a real-time acquisition at the device paired with PluxDev method (on muscleBAN).

void StartAcquisitionMuscleBanUnity(int samplingRate, List<int> listChannels, int resolution, int freqDivisor)

Description

The current API version supports real-time acquisitions with analogical sensors, however, to communicate with computer the PLUX device needs to execute an Analogical to Digital Conversion (ADC), through data sampling. Taking ADC stage into consideration, while starting a real-time acquisition, selecting a specific sampling rate and resolution is extremely easy through the inputs of StartAcquisitionMuscleBanUnity. The main difference on the inputs of this function in comparison with StartAcquisitionUnity, is the additional freqDivisor argument, that transmits the information regarding the subsampling level to be applied during the muscleBAN data acquisition.

Parameters

  • samplingRate int: Desired sampling rate that will be used during the data acquisition stage. The used units are in Hz (samples/s).
  • listChannels List<int>: A list where it can be specified the active channels. Each entry contains a port number of an active channel.
  • resolution int: Analog-to-Digital Converter (ADC) resolution. This parameter defines how precise are the digital sampled values when compared with the ideal real case scenario.
  • freqDivisor int: Frequency divisor, i.e., acquired data will be subsampled accordingly to this parameter. If freqDivisor = 10, it means that each set of 10 acquired samples will trigger the communication of a single sample (through the communication loop).

StopAcquisitionUnity

Class method used to interrupt the real-time communication loop triggered by StartAcquisitionUnity(), StartAcquisitionByNbrUnity() or StartAcquisitionMuscleBanUnity() methods.

bool StopAcquisitionUnity(int forceStop=0)

Description

After starting a real-time acquisition a communication loop between the PLUX device and the computer starts running on a parallel thread. With StopAcquisitionUnity() function, first of all, the communication loop is interrupted, task followed by the stop of the real-time acquisition and finally the thread closure.

Parameters

  • forceStop int: Integer code identifying the cause of acquisition stop (>= 0 | manually invoked by the user; -1 | device turned off; -2 | communication timeout exceeded).

Returned Values

A bool flag is returned identifying when the stop event was forced (true) or manually invoked by the user (false).

GetDetectableDevicesUnity

Class method intended to find the list of detectable devices through Bluetooth communication.

void GetDetectableDevicesUnity(List<string> domains)

Description

Internally the list of detected devices reaches PluxDeviceManager.cs in a string format, where each device mac-address is separated from each other by a "&" character.

GetDetectableDevicesUnity trigger the start of a Bluetooth scan in a parallel thread.

In GetDetectableDevicesUnity an automatic split of the received string took place, ensuring that a list with the available mac-addresses will be returned.

WARNING

To access the results of the previously started asynchronous task, a callback with the following format should be implemented in your application:

public void ScanResults(List<string> listDevices)

Parameters

  • domains List<string>: A list containing the Bluetooth domains to be searched (BTH or BLE). Each domain inside the list will be used while searching for PLUX devices [Valid Options: "BTH" -> classic Bluetooth; "BLE" -> Bluetooth Low Energy]

Returned Values

A list of strings containing the mac-addresses of all PLUX devices detected during the Bluetooth scan.

GetNbrChannelsUnity

Getter method used for determination of the number of used channels during the real-time acquisition.

int GetNbrChannelsUnity()

Description

A simple method that returns the number of samples being used on the real-time acquisition under execution.

Parameters

Function without input parameters

Returned Values

An integer identifying the number of active channels in the PLUX device connected to the computer through Bluetooth.

GetBatteryUnity

Getter method dedicated to check the battery level of the device.

int GetBatteryUnity()

Description

Having a feedback about the energy level of electronic devices is extremely important and useful. With this method an integer with the percentage (0-100%) of battery level is returned.

Parameters

Function without input parameters

Returned Values

The percentage level of battery.

GetDeviceTypeUnity

Getter method intended to check the type of the PLUX device connected with computer.

string GetDeviceTypeUnity()

Description

With this method a string is retrieved, identifying which type of PLUX device is connected with the computer. The possible values are "biosignalsplux", "BITalino" or "MuscleBAN BE Plux"

Parameters

Function without input parameters

Returned Values

A string that identifies which PLUX device is currently connected to the computer.

GetProductIdUnity

Getter method dedicated to identify the ID number that identifies the type of device under analysis.

int GetProductIdUnity()

Description

The following unique identifiers defined which type of PLUX device is connected to the computer:

  • biosignalsplux >>> 513
  • biosignalsplux Hybrid-8 >>> 517
  • biosignalsplux Solo >>> 532
  • BITalino (r)evolution >>> 1538
  • muscleBAN >>> 1282
  • muscleBAN (Newer Generations) >>> 2049

Parameters

Function without input parameters

Returned Values

The product ID of the device connected to the computer.

IsAcquisitionInProgress

Getter method dedicated to identify a real-time data acquisition is currently in progress.

bool IsAcquisitionInProgress()

Description

Through a boolean flag, this method identifies if a data acquisition is currently running and if the PLUX device is streaming data to the computer.

Parameters

Function without input parameters

Returned Values

A boolean flag stating if an acquisition is in progress (true) or not (false).

SetParameter

"Setting" method intended to define the value of a specific parameter in the PLUX device connected with the computer or its sensors.

void SetParameter(int port, int index, int[] data)

Description

With the SetParameter method, the developer has the possibility of customizing system specific variables (in the PLUX device) or sensor parameters, for example, the intensity of the RED and INFRARED LEDs included in the fNIRS sensor.

[Definition of LED Intensity on the fNIRS/SpO2 Sensor]

// Configure SpO2 channel intensity if dealing with fNIRS Explorer port/chnMask.
int[] ledParam = { 80, 40 }; // Percentage values.
PluxDevManager.SetParameter(0x09, 0x03, ledParam); // update oximeter LED values (Red and IR)

Parameters

  • port int: Sensor port number for a sensor parameter, or zero for a system parameter.
  • index const void: Index of the parameter to set within the sensor or system.
  • data int[]: List containing the values to assign to the parameter under analysis.

Support

If you find any problem during your experience, please, feel free to create a new issue track on our repository. We will be very glad to guide you in this amazing journey and listen your suggestions!

About

Unity Sample APP intended to show a practical integration of PLUX devices with the Unity environment, encompassing functionalities such as: the search of compatible Bluetooth devices and also the start/stop of a real-time acquisition.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published