[SYSTEM] Disabling serial port communication [NTP] NTP internet time enabled via server pool.ntp.org with timezone 3 [MQTT] Connecting to MQTT... [NTP] Internet time: 10:44:01 UTC on 22/1. Local time: 10:44:01 GMT [MQTT] MQTT connected [SYSTEM] Free Heap: 23200 bytes initially | 8472 bytes used (36%) | 14728 bytes free (63%) New EMS device recognized as a UBAMaster: Buderus Logamax plus/GB192/Bosch Condens GC9000 (DeviceID:0x08 ProductID:208 Version:01.04) New EMS device recognized as a Controller: W-B ErP Boiler Control Panel (DeviceID:0x09 ProductID:209 Version:01.04) 3)ceID:0x10 ProductID:158 Version:33.0tat: RC300/RC310/Moduline 3000 Version:29.04)ID:0x28 ProductID:161 sion:29.04)ng Module: MM200 Mixing Module (DeviceID:0x29 ProductID:161 Ver [TELNET] Connected to EMS-ESP version 1.9.5b18m. Type ? for commands. info EMS-ESP system status: System logging set to None LED: on, Listen mode: off Boiler: enabled, Thermostat: enabled, Solar Module: disabled, Mixing Module: enabled Shower Timer: disabled, Shower Alert: disabled EMS Bus status: Bus is connected, protocol: HT3 Rx: # successful read requests=326, # CRC errors=0 Tx: Last poll=0.375 seconds ago, # successful write requests=0 Boiler data: Boiler: Buderus Logamax plus/GB192/Bosch Condens GC9000 (DeviceID:0x08 ProductID:208 Version:01.04) Hot tap water: off Central heating: active Warm Water activated: on Warm Water circulation pump available: off Warm Water comfort setting: Eco Warm Water selected temperature: 60 C Warm Water desinfection temperature: 70 C Warm Water Circulation active: off Warm Water current temperature: 62.5 C Warm Water current tap water flow: 0.0 l/min Warm Water # starts: 1058 times Warm Water active time: 7 days 17 hours 21 minutes Warm Water 3-way valve: off Selected flow temperature: 50 C Current flow temperature: 53.4 C Return temperature: ? C Gas: on Boiler pump: on Fan: on Ignition: off Circulation pump: off Burner selected max power: 100 % Burner current power: 30 % Flame current: 17.7 uA System pressure: ? bar System service code: (200) Heating temperature setting on the boiler: 50 C Boiler circuit pump modulation max power: 100 % Boiler circuit pump modulation min power: 60 % Outside temperature: 7.8 C Boiler temperature: ? C Exhaust temperature: ? C Pump modulation: 60 % Burner # starts: 24813 times Total burner operating time: 105 days 23 hours 28 minutes Total heat operating time: 98 days 6 hours 7 minutes Total UBA working time: 691 days 12 hours 42 minutes Thermostat data: Thermostat: RC300/RC310/Moduline 3000/Bosch CW400/W-B Sense II (DeviceID:0x10 ProductID:158 Version:33.03) Thermostat time is 11:14:43 22/01/2020 Heating Circuit 1 Current room temperature: ? C Setpoint room temperature: 30.0 C Calculatet flow temperature: ? C Mode is set to auto Day Mode is set to day Mixing module data: Warm Water Circuit 1 Current warm water temperature: 62.3 C Current pump status: 0 Current temp status: 0 Warm Water Circuit 2 Current warm water temperature: 65.9 C Current pump status: 0 Current temp status: 0 devices These device IDs are on the EMS Bus: 0x08 0x09 0x10 0x28 0x29 and 5 were recognized by EMS-ESP as: UBAMaster: Buderus Logamax plus/GB192/Bosch Condens GC9000 (DeviceID:0x08 ProductID:208 Version:01.04) Controller: W-B ErP Boiler Control Panel (DeviceID:0x09 ProductID:209 Version:01.04) Thermostat: RC300/RC310/Moduline 3000/Bosch CW400/W-B Sense II (DeviceID:0x10 ProductID:158 Version:33.03) Mixing Module: MM200 Mixing Module (DeviceID:0x28 ProductID:161 Version:29.04) Mixing Module: MM200 Mixing Module (DeviceID:0x29 ProductID:161 Version:29.04) mqttlog MQTT publish log: (10:44:01) Topic:status Payload:online (10:44:01) Topic:start Payload:start (11:14:01) Topic:heartbeat Payload:{"rssid":70,"load":1,"uptime":1811,"freemem":22} (10:44:01) Topic:shower_data Payload:{"timer":"0","alert":"0"} (11:13:56) Topic:boiler_data Payload:{"wWComfort":"Eco","wWSelTemp":60,"wWDesinfectionTemp":70,"selFlowTemp":50,"selBurnPow":100,"curBurnPow":0,"pumpMod":60,"wWCircPump":0,"outdoorTemp":7.8,"wWCurTmp":62.7,"wWCurFlow":0,"curFlowTemp":42.8,"wWActivated":"on","wWOnetime":"off","wWCirc":"off","burnGas":"off","flameCurr":0,"heatPmp":"on","fanWork":"off","ignWork":"off","heating_temp":50,"pump_mod_max":100,"pump_mod_min":60,"wWHeat":"off","wWStarts":1058,"wWWorkM":11121,"UBAuptime":995800,"burnStarts":24812,"burnWorkMin":152607,"heatWorkMin":141486,"ServiceCode":"","ServiceCodeNumber":202} (11:11:56) Topic:tapwater_active Payload:0 (11:11:56) Topic:heating_active Payload:0 (11:13:56) Topic:thermostat_data Payload:{"hc1":{"seltemp":30,"mode":"auto"}} (11:13:56) Topic:mixing_data Payload:{"wwc1":{"wwTemp":62.4,"pumpStatus":0,"tempStatus":0},"wwc2":{"wwTemp":65.9,"pumpStatus":0,"tempStatus":0}}