valentinsulzer
left a comment
There was a problem hiding this comment.
Thanks @brosaplanella , looks good, but my worry is this is going to have to be developed completely separately from the existing submodel structure (including degradation mechanisms, etc)
| "separator": 13, | ||
| "positive electrode": 17, | ||
| "working electrode": 19, | ||
| "working particle": 23, |
There was a problem hiding this comment.
Need to check why this was necessary but not urgent
There was a problem hiding this comment.
I think this has to do because the separator and current collector were defined in fixed_domain_sizes but the new domains weren't, so when they interact it breaks down...
Also, random question related to that. When we get the size of a variable defined in a domain in fixed_domain_sizes, why do we take the sum and not the product? I thought the idea of assigning prime numbers to the domains was to get unique signatures for each combination.
I agree. I was debating if I wanted to created the PR until I had integrated it into the submodel structure, but I thought it would be much better to get feedback at this stage. The problem with the old version, apart from signs changing depending on which is the working electrode, was that you got a lot of unused variables. Probably this is not ideal either though... Is there any other way we can do this? The only way I can think of bringing all the models closer together is by redefining them so you can define each electrode separately, but that would be a major reformat of PyBaMM... |
|
I was running the DFN_half_cell example and changing "Lithium counter electrode thickness [m]" and it didn't appear to change anything... |
This only appears in the Ohmic losses in the lithium counter, but the conductivity is so high that you probably won't see any change unless you plug in a massive lithium counter. |
Description
Reformatted the Basic DFN half-cell model. In the new setup, the lithium counter always sits on the left and the working electrode on the right. The new geometry has a
working electrodeand aworking particle.Fixes #1253