Save .OP simulation result to dataset #124

Closed
tomhajjar opened this issue Jul 29, 2022 · 3 comments · Fixed by #513
Closed

Save .OP simulation result to dataset #124

tomhajjar opened this issue Jul 29, 2022 · 3 comments · Fixed by #513

Comments

@tomhajjar
Copy link

Is there a reason Qucs-S won't do a simple DC operating point (.op)? Qucs does it and I assume ngspice will do it as well.

If I add say a DC Parameter Sweep it does work.

Test_prj.zip

@ra3xdh
Copy link
Owner

ra3xdh commented Jul 29, 2022

I know about this problem. Qucs-S currently supports only F8 mode to show the .OP result. The single DC simulation device has no effect and the operation point is not saved to the dataset. See also #3

@ra3xdh ra3xdh changed the title Qucs-S won't run simple .op Save .OP simulation result to dataset Jul 30, 2022
@ra3xdh
Copy link
Owner

ra3xdh commented Jul 30, 2022

Combined with #3

@ra3xdh
Copy link
Owner

ra3xdh commented Feb 1, 2024

Fixed via #513