161 changes: 161 additions & 0 deletions cscs-checks/tools/profiling_and_debugging/intel_advisor_roofline.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,161 @@
import os

import reframe as rfm
import reframe.utility.sanity as sn


@rfm.required_version('>=2.14')
@rfm.parameterized_test(*[[repeat, toolsversion, datalayout]
for repeat in ['50000']
for toolsversion in ['551025']
for datalayout in ['G3_AOS_SCALAR', 'G3_SOA_SCALAR',
'G3_AOS_VECTOR', 'G3_SOA_VECTOR',
'G3_SOA_VECTOR_FMAS']])
class IntelRooflineTest(rfm.RegressionTest):
'''This test checks the values reported by Intel Advisor's roofline model:
https://software.intel.com/en-us/intel-advisor-xe

The roofline model is based on GFLOPS and Arithmetic Intensity (AI):
"Self GFLOPS" = "Self GFLOP" / "Self Elapsed Time"
"Self GB/s" = "Self Memory GB" / "Self Elapsed Time"
"Self AI" = "Self GFLOPS" / "Self GB/s"

While a roofline analysis flag exists ('advixe-cl -collect roofline'), it
may not be used to collect data on MPI applications; in that case, the
survey and flops analysis must be collected separately: first run a survey
analysis ('advixe-cl -collect survey') and then run a tripcounts+flops
analysis ('advixe-cl -collect tripcounts -flop') using the same project
directory for both steps.
'''
def __init__(self, repeat, toolsversion, datalayout):
super().__init__()
self.descr = 'Roofline Analysis test with Intel Advisor'
self.valid_systems = ['daint:mc', 'dom:mc']
# Reporting MFLOPS is not available on Intel Haswell cpus, see
# https://www.intel.fr/content/dam/www/public/us/en/documents/manuals/
# 64-ia-32-architectures-software-developer-vol-1-manual.pdf
self.valid_prog_environs = ['PrgEnv-intel']
self.prgenv_flags = {
'PrgEnv-intel': ['-O2', '-g', '-std=c++11'],
}
self.sourcesdir = os.path.join(self.current_system.resourcesdir,
'roofline', 'intel_advisor')
self.build_system = 'Make'
self.prebuild_cmd = [
'sed -e "s-XXXX-%s-" -e "s-YYYY-%s-" %s &> %s' %
(repeat, datalayout, 'roofline_template.cpp', '_roofline.cpp')
]
self.num_tasks = 1
self.num_tasks_per_node = 1
self.num_cpus_per_task = 1
self.variables = {
'OMP_NUM_THREADS': str(self.num_cpus_per_task),
'CRAYPE_LINK_TYPE': 'dynamic',
}
self.pre_run = [
# Testing with advisor/2018 Update 2 (build 551025):
# advisor/2019 is broken on dom ("Exceeded job memory limit"),
# and advisor/2019 is not installed on daint,
'source $INTEL_PATH/../advisor_2018/advixe-vars.sh',
'advixe-cl -help collect | head -20',
]
self.executable = 'advixe-cl'
self.target_executable = './roof.exe'
self.roofdir = './roof.dir'
self.executable_opts = [
'--collect survey --project-dir=%s --search-dir src:rp=. '
'--data-limit=0 --no-auto-finalize --trace-mpi -- %s ' %
(self.roofdir, self.target_executable)
]
self.version_rpt = 'Intel_Advisor_version.rpt'
self.roofline_ref = 'Intel_Advisor_roofline_reference.rpt'
self.roofline_rpt = 'Intel_Advisor_roofline_results.rpt'
# Reference roofline boundaries for Intel Broadwell CPU (E5-2695 v4):
L1bw = 293*1024**3
L2bw = 79*1024**3
L3bw = 33*1024**3
DPfmabw = 49*1024**3
DPaddbw = 12*1024**3
ScalarAddbw = 3*1024**3
self.sanity_patterns = sn.all([
# check the job status:
sn.assert_found('loop complete.', self.stdout),
# check the tool's version:
sn.assert_eq(sn.extractsingle(
r'I*.\(build\s(?P<toolsversion>\d+)\s*.',
self.version_rpt, 'toolsversion'), toolsversion),
# --- roofline boundaries:
# check --report=roofs (L1 bandwidth):
sn.assert_reference(sn.extractsingle(
r'^L1\sBandwidth\s\(single-threaded\)\s+(?P<L1bw>\d+)\s+'
r'memory$', self.roofline_ref, 'L1bw', int),
L1bw, -0.08, 0.08),
# check --report=roofs (L2 bandwidth):
sn.assert_reference(sn.extractsingle(
r'^L2\sBandwidth\s\(single-threaded\)\s+(?P<L2bw>\d+)\s+'
r'memory$', self.roofline_ref, 'L2bw', int),
L2bw, -0.08, 0.08),
# check --report=roofs (L3 bandwidth):
sn.assert_reference(sn.extractsingle(
r'^L3\sBandwidth\s\(single-threaded\)\s+(?P<L3bw>\d+)\s+'
r'memory$', self.roofline_ref, 'L3bw', int),
L3bw, -0.08, 0.08),
# check --report=roofs (DP FMA):
sn.assert_reference(sn.extractsingle(
r'^DP Vector FMA Peak\s\(single-threaded\)\s+'
r'(?P<DPfmabw>\d+)\s+compute$', self.roofline_ref,
'DPfmabw', int), DPfmabw, -0.08, 0.08),
# check --report=roofs (DP Add):
sn.assert_reference(sn.extractsingle(
r'^DP Vector Add Peak\s\(single-threaded\)\s+'
r'(?P<DPaddbw>\d+)\s+compute$', self.roofline_ref,
'DPaddbw', int), DPaddbw, -0.08, 0.08),
# check --report=roofs (Scalar Add):
sn.assert_reference(sn.extractsingle(
r'^Scalar Add Peak\s\(single-threaded\)\s+'
r'(?P<ScalarAddbw>\d+)\s+compute$', self.roofline_ref,
'ScalarAddbw', int), ScalarAddbw, -0.08, 0.08),
# --- check Arithmetic_intensity:
sn.assert_reference(sn.extractsingle(
r'^returned\sAI\sgap\s=\s(?P<Intensity>.*)', self.roofline_rpt,
'Intensity', float), 0.0, -0.01, 0.01),
# --- check GFLOPS:
sn.assert_reference(sn.extractsingle(
r'^returned\sGFLOPS\sgap\s=\s(?P<Flops>.*)', self.roofline_rpt,
'Flops', float), 0.0, -0.01, 0.01),
])
self.maintainers = ['JG']
self.tags = {'production'}

def setup(self, partition, environ, **job_opts):
super().setup(partition, environ, **job_opts)
environ_name = self.current_environ.name
prgenv_flags = self.prgenv_flags[environ_name]
self.build_system.cxxflags = prgenv_flags
launcher_cmd = ' '.join(self.job.launcher.command(self.job))
self.post_run = [
# collecting the performance data for the roofline model is a 2
# steps process:
'%s %s --collect tripcounts --flop --project-dir=%s '
'--search-dir src:rp=. --data-limit=0 --no-auto-finalize '
'--trace-mpi -- %s' %
(launcher_cmd, self.executable, self.roofdir,
self.target_executable),
# check tool's version:
'advixe-cl -V &> %s' % self.version_rpt,
# "advixe-cl --report" looks for e000/ in the output directory;
# if not found, it will fail with:
# IOError: Survey result cannot be loaded
'cd %s;ln -s nid* e000;cd -' % self.roofdir,
# report reference values/boundaries (roofline_ref):
'advixe-cl --report=roofs --project-dir=%s &> %s' %
(self.roofdir, self.roofline_ref),
'python2 API/cscs.py %s &> %s' % (self.roofdir, self.roofline_rpt),
# 'advixe-cl --format=csv' seems to be not working (empty report),
# keeping as reference for a future check:
# 'advixe-cl --show-all-columns -csv-delimiter=";"'
# ' --report=tripcounts --format=csv --project-dir=%s &> %s'
# This can be used instead (see advisor/config/report/roofs.tmpl):
# 'advixe-cl --report custom --report-template ./TEMPL/cscs.tmpl'
# ' --project-dir=%s &> %s'
]