RH >100% #1

Closed
adamhsparks opened this issue May 22, 2016 · 2 comments
Closed

RH >100% #1

adamhsparks opened this issue May 22, 2016 · 2 comments
Assignees

Comments

@adamhsparks
Copy link
Member

@adamhsparks adamhsparks commented May 22, 2016

RH is sometimes calculated at being >100%. This means that ea and es are also incorrect.

Check TDEW and TEMP relationships in these data to see what relationship exists in these instances and correct or remove spurious data.

@adamhsparks adamhsparks self-assigned this May 22, 2016
@adamhsparks
Copy link
Member Author

@adamhsparks adamhsparks commented May 25, 2016

Reason

When importing .op files, for temperature values >100F the first two digits are truncated.

Corrective action

Change methodology from readr::read_table to another method to fix this issue.

@adamhsparks
Copy link
Member Author

@adamhsparks adamhsparks commented May 26, 2016

Fixed in this merge from devel branch: adamhsparks@07836d1

adamhsparks added a commit that referenced this issue Aug 28, 2019