README.md

modbus

Modbus library with TCP Master & Slave implementation.

For Serial RTU see baud.

Based on:

Installation and Usage

  1. Add modbus to your list of dependencies in mix.exs:
def deps do
  [{:modbus, "~> 0.3.7"}]
end
  1. Use as TCP master:
#run with: mix opto22
alias Modbus.Tcp.Master

# opto22 rack configured as follows
# m0 - 4p digital input
#  p0 - 24V
#  p1 - 0V
#  p2 - m1.p2
#  p3 - m1.p3
# m1 - 4p digital output
#  p0 - NC
#  p1 - NC
#  p2 - m0.p2
#  p3 - m0.p3
# m2 - 2p analog input (-10V to +10V)
#  p0 - m3.p0
#  p1 - m3.p1
# m3 - 2p analog output (-10V to +10V)
#  p0 - m2.p0
#  p1 - m2.p1

{:ok, pid} = Master.start_link([ip: {10,77,0,2}, port: 502])

#turn off m1.p0
:ok = Master.exec(pid, {:fc, 1, 4, 0})
#turn on m1.p1
:ok = Master.exec(pid, {:fc, 1, 5, 1})
#alternate m1.p2 and m1.p3
:ok = Master.exec(pid, {:fc, 1, 6, [1, 0]})

#https://www.h-schmidt.net/FloatConverter/IEEE754.html
#write -5V (IEEE 754 float) to m3.p0
#<<-5::float-32>> -> <<192, 160, 0, 0>>
:ok = Master.exec(pid, {:phr, 1, 24, [0xc0a0, 0x0000]})
:ok = Master.exec(pid, {:phr, 1, 24, Modbus.IEEE754.to_2_regs(-5.0, :be)})
#write +5V (IEEE 754 float) to m3.p1
#<<+5::float-32>> -> <<64, 160, 0, 0>>
:ok = Master.exec(pid, {:phr, 1, 26, [0x40a0, 0x0000]})
:ok = Master.exec(pid, {:phr, 1, 26, Modbus.IEEE754.to_2_regs(+5.0, :be)})

:timer.sleep(20) #outputs settle delay

#read previous coils as inputs
{:ok, [0, 1, 1, 0]} = Master.exec(pid, {:ri, 1, 4, 4})

#read previous analog channels as input registers
{:ok, [0xc0a0, 0x0000, 0x40a0, 0x0000]} = Master.exec(pid, {:rir, 1, 24, 4})
{:ok, data} = Master.exec(pid, {:rir, 1, 24, 4})
[-5.0, +5.0] = Modbus.IEEE754.from_2n_regs(data, :be)
  1. Use as TCP slave:
#run with: mix slave
alias Modbus.Tcp.Slave
alias Modbus.Tcp.Master

#start your slave with a shared model
model = %{ 0x50=>%{ {:c, 0x5152}=>0 } }
{:ok, spid} = Slave.start_link([model: model])
#get the assigned tcp port
{:ok, %{port: port}} = Slave.id(spid)

#interact with it
{:ok, mpid} = Master.start_link([ip: {127,0,0,1}, port: port])
{:ok, [0]} = Master.exec(mpid, {:rc, 0x50, 0x5152, 1})
...

Endianess

Roadmap

Future

  • Improve documentation and samples
  • Improve error handling

Version 0.3.7

  • Changed little endian flag from :se to :le

Version 0.3.6

  • Added endianness flag to float helpers

Version 0.3.5

  • Added float helper

Version 0.3.4

  • Fixed RTU CRC endianess

Version 0.3.3

  • Shared model slave implementation

Version 0.3.2

  • Added request length prediction
  • Refactored namespaces to avoid baud clash
  • Tcp master api updated to match baud rtu master api

Version 0.3.1

  • Added master/slave test for each code
  • Added response length prediction
  • Added a couple of helpers to tcp and rtu api
  • A reference-only tcp slave added in test helper

Version 0.3.0

  • Modbus TCP slave: wont fix, to be implemented as forward plugin
  • API breaking changes

Version 0.2.0

  • Updated documentation
  • Renamed commands to match spec wording

Version 0.1.0

  • Modbus TCP master
  • Request/response packet builder and parser
  • Device model to emulate slave interaction