Error shown when triggering a sigint during shelljs.exec if process.on sigint is defined #254

Closed
pajtai opened this issue Nov 14, 2015 · 5 comments
Labels
exec fix help wanted low priority

Comments

@pajtai
Copy link

@pajtai pajtai commented Nov 14, 2015

Execute this file to reproduce

#!/usr/bin/env node
'use strict';

process.on('SIGINT', function() { console.log('done'); });
var exec = require('shelljs').exec('sleep 30');

Now press ctr-c before the sleep is done and you get an error like the following:

^Cshell.js: internal error
Error: ENOENT: no such file or directory, open '/var/folders/s1/hl12yyyd0n3djffckxzc8fdm0000gp/T/shelljs_639bf41add87c30b7ccb'
at Error (native)
at Object.fs.openSync (fs.js:584:18)
at Object.fs.readFileSync (fs.js:431:33)
at execSync

@ariporad ariporad added the fix label Jan 9, 2016
@bompi88
Copy link

@bompi88 bompi88 commented Jan 29, 2016

+1

@nfischer
Copy link
Member

@nfischer nfischer commented Jan 30, 2016

Confirmed. I think this has to do with the way we force exec to be synchronous (by writing to temp files)

@cqgao
Copy link

@cqgao cqgao commented Aug 24, 2016

+1

@nfischer nfischer added the exec label May 9, 2018
@nfischer
Copy link
Member

@nfischer nfischer commented Jul 11, 2018

I'm going to merge this into #495. The new design won't use tempfiles by default.

@HamidOsouli
Copy link

@HamidOsouli HamidOsouli commented May 3, 2020

+1