New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Other layers temperature not handled correctly with complete individual enabled #2702

Closed
sorki opened this Issue Mar 2, 2015 · 2 comments

Comments

Projects
None yet
3 participants
@sorki

sorki commented Mar 2, 2015

Other layers temperature is set only for the first object.

Slic3r 1.2.6

$ grep temperature v4x_20mm-box_kossel.gcode 
M104 S205 ; set temperature
M109 S205 ; wait for temperature to be reached
M104 S215 ; set temperature
M104 S205 ; set temperature
M104 S205 ; set temperature
M104 S205 ; set temperature
; bed_temperature = 0
; first_layer_bed_temperature = 0
; first_layer_temperature = 205
; standby_temperature_delta = -5
; temperature = 215

@alexrj alexrj added this to the 1.2.7 milestone Mar 2, 2015

alexrj added a commit that referenced this issue Mar 2, 2015

@alexrj alexrj added the Fixed label Mar 2, 2015

@alexrj

This comment has been minimized.

Show comment
Hide comment
@alexrj

alexrj Mar 2, 2015

Member

Good catch. I fixed this and added a regression test.

Member

alexrj commented Mar 2, 2015

Good catch. I fixed this and added a regression test.

@lordofhyphens

This comment has been minimized.

Show comment
Hide comment
@lordofhyphens

lordofhyphens Mar 10, 2015

Member

This might have been around since 1.1.7: #2727

Member

lordofhyphens commented Mar 10, 2015

This might have been around since 1.1.7: #2727

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment