Migration notes from the 1.2 series
===================================
Init
====
modbus_init_tcp requires a third new argument, the port number.
modbus_init_tcp(modbus_param_t *mb_param, char *ip_address, int port)
Set the port to MODBUS_TCP_DEFAULT_PORT to use the default one
(502). It's convenient to use a port number greater than or equal to
1024 because it's not necessary to be root to use this port number.
Pointers of data
================
The coil and input status are now stored in an array of type uint8_t
(in 1.2.X series, array of type int was used). So now, you need to
pass a pointer of type uint8_t to use read_coil_status(), for example.
The holding and input registers are now stored in an array of type
uint16_t.
These changes reduce the memory consumption.
New functions
=============
report_slave_id
modbus_set_error_handling
modbus_mapping_new
modbus_mapping_free
modbus_init_listen_tcp
modbus_listen
modbus_manage_query
get_slave_query_tcp
set_bits_from_byte
set_bits_from_bytes
get_byte_from_bits
Read modbus.h for more informations.