#include <SimpleTimer.h> // Timer library
#define BLYNK_PRINT Serial // Turn this on to see basic Blynk activities
//#define BLYNK_DEBUG // Turn this on to see *everything* Blynk is doing... really fills up serial monitor!
#include <ESP8266mDNS.h> // Required for OTA
#include <WiFiUdp.h> // Required for OTA
#include <ArduinoOTA.h> // Required for OTA
#include <BlynkSimpleEsp8266.h>
#include <TimeLib.h> // Used by WidgetRTC.h
#include <WidgetRTC.h> // Blynk's RTC
#include <OneWire.h> // Temperature sensor library
#include <DallasTemperature.h> // Temperature sensor library
#define ONE_WIRE_BUS 12 // WeMos pin D6. RA/SA temp sensor array.
OneWire oneWire(ONE_WIRE_BUS);
DallasTemperature sensors(&oneWire);
DeviceAddress ds18b20RA = { 0x28, 0xEF, 0x97, 0x1E, 0x00, 0x00, 0x80, 0x54 }; // Return air probe - Device address found by going to File -> Examples -> DallasTemperature -> oneWireSearch
DeviceAddress ds18b20SA = { 0x28, 0xF1, 0xAC, 0x1E, 0x00, 0x00, 0x80, 0xE8 }; // Supply air probe
char auth[] = "fromBlynkApp";
char ssid[] = "ssid";
char pass[] = "pw";
SimpleTimer timer;
WidgetRTC rtc;
WidgetTerminal terminal(V26);
const int fanRelay = 16; // WeMos pin D0. Set LOW to start fan-only.
const int coolingRelay = 5; // WeMos pin D1. Set LOW to start cooling.
const int heatingRelay = 4; // WeMos pin D2. Set LOW to start heating.
const int bypassRelay = 0; // WeMos pin D3. Set LOW to bypass house t-stat.
const int fanPin = 14; // WeMos pin D5. LOW when fan-only is running.
const int blowerPin = 13; // WeMos pin D7. LOW when cool or heat is running.
double tempRA, tempSA; // Return air and supply air temperatures.
bool fanOnly; // true when fan-only mode is running
bool fanCooling; // true when cooling mode is running
bool fanHeating; // true when heating mode is running
long todaysRuntimeSec; // How many seconds the HVAC ran today
int todaysRuntimeMin; // How many minutes the HVAC ran today
int currentRunSec; // How many seconds the HVAC has ran in it's current cycle (resets after HVAC turns off)
long filterUseSec; // How many seconds the current filter has been used. Can be reset manually after filter change.
int yesterdaysRuntimeSec, yesterdaysRuntimeMin;
int todaysRuns; // How many times the HVAC has ran today (counted when it shuts off).
int coolingCounter, heatingCounter; // Count approx how many minutes unit cooled/heated. Used for Tweeting.
String currentStatus; // For the sole purpose of syncing back the status label after a hardware reset
int todaysDate; // Today's date (15 or 16, etc)
String currentTime;
String currentTimeDate;
String changeTimeDate;
bool changeFlag;
bool ranOnce;
bool filterChangeMode;
bool startupSynced;
int fanStatusTimer, setClockTimeTimer, tempDisplayTimer, statusDisplayTimer, longStatusDisplayTimer, tempWatcherTimer;
double tempAT, tempKK, tempLK, tempMK; // Temperatures bridged in from other devices to use for control.
int controllingRoom;
int setpointTemp; // The HVAC target temperature
int triggerTemp = 1; // The number of degrees above/below setpoint that the HVAC will start
int tempDiff = 1; // Temperature differential. You can add 1 to whatever is here because of the way the code compared a double and an int.
bool coolingMode, heatingMode; // True when cooling or heating is on
int i, maxT, highRoom; // Used to evaluate all room temperatures in whole-house cooling mode
bool overrunFlag;
void setup()
{
Serial.begin(9600);
WiFi.mode(WIFI_STA);
Blynk.begin(auth, ssid, pass);
sensors.begin();
sensors.setResolution(ds18b20RA, 10);
sensors.setResolution(ds18b20SA, 10);
// Set pin modes used to control HVAC
pinMode(coolingRelay, OUTPUT);
pinMode(heatingRelay, OUTPUT);
pinMode(fanRelay, OUTPUT);
pinMode(bypassRelay, OUTPUT);
// Default all HVAC relays to off
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(fanRelay, HIGH);
digitalWrite(bypassRelay, HIGH);
while (Blynk.connect() == false) {
// Wait until connected
}
// START OTA ROUTINE
ArduinoOTA.setHostname("hvacMonitor"); // Port name that is displayed in the Arduino IDE.
ArduinoOTA.onStart([]() {
Serial.println("Start");
});
ArduinoOTA.onEnd([]() {
Serial.println("\nEnd");
});
ArduinoOTA.onProgress([](unsigned int progress, unsigned int total) {
Serial.printf("Progress: %u%%\r", (progress / (total / 100)));
});
ArduinoOTA.onError([](ota_error_t error) {
Serial.printf("Error[%u]: ", error);
if (error == OTA_AUTH_ERROR) Serial.println("Auth Failed");
else if (error == OTA_BEGIN_ERROR) Serial.println("Begin Failed");
else if (error == OTA_CONNECT_ERROR) Serial.println("Connect Failed");
else if (error == OTA_RECEIVE_ERROR) Serial.println("Receive Failed");
else if (error == OTA_END_ERROR) Serial.println("End Failed");
});
ArduinoOTA.begin();
Serial.println("Ready");
Serial.print("IP address: ");
Serial.println(WiFi.localIP());
Serial.print("MAC address: ");
Serial.println(WiFi.macAddress());
// END OTA ROUTINE
rtc.begin();
fanStatusTimer = timer.setInterval(1000, fanStatus);
setClockTimeTimer = timer.setInterval(1000, setClockTime);
tempDisplayTimer = timer.setInterval(3210, tempDisplay);
statusDisplayTimer = timer.setInterval(3543, statusDisplay);
tempWatcherTimer = timer.setInterval(5000, tempWatcher);
longStatusDisplayTimer = timer.setInterval(600000, longStatusDisplay); // 10 minutes
timer.setInterval(65432, updateVpinData1);
timer.disable(fanStatusTimer);
timer.disable(tempDisplayTimer);
timer.disable(statusDisplayTimer);
timer.disable(tempWatcherTimer);
}
void loop() // To keep Blynk happy, keep most tasks out of the loop.
{
Blynk.run();
timer.run();
ArduinoOTA.handle();
if (!startupSynced && year() != 1970) {
startupSynced = true;
startupSync();
todaysDate = day();
timer.setTimeout(5000, startTimers);
}
}
// BEGIN CONTROL SECTION
//int tempATreportMin, tempKKreportMin, tempLKreportMin, tempMKreportMin;
double tempATlast, tempKKlast, tempLKlast, tempMKlast;
int tempATmatch, tempKKmatch, tempLKmatch, tempMKmatch;
BLYNK_WRITE(V127) { // Collect temperature data from sensors (sensors push data) and notify if sensor is not reporting
int nodeData = param[0].asInt();
double tempData = param[1].asDouble();
if (nodeData == 1) {
tempAT = tempData;
//tempATreportMin = minute();
if (tempAT == tempATlast) { // If temps match...
++tempATmatch; // count how many times they matched.
}
else { // if they didn't
tempATmatch = 0; // reset the match counter
tempATlast = tempAT; // and "reset" tempATlast.
}
//Serial.println(String("[") + currentTime + "] AT:" + tempAT + "F (" + tempATmatch + "/" + tempATreportMin + "m)");
Serial.println(String("[") + currentTime + "] AT:" + tempAT + "F (" + tempATmatch + ")");
}
else if (nodeData == 2) {
tempKK = tempData;
//tempKKreportMin = minute();
if (tempKK == tempKKlast) {
++tempKKmatch;
}
else {
tempKKmatch = 0;
tempKKlast = tempKK;
}
//Serial.println(String("[") + currentTime + "] KK:" + tempKK + "F (" + tempKKmatch + "/" + tempKKreportMin + "m)");
Serial.println(String("[") + currentTime + "] KK:" + tempKK + "F (" + tempKKmatch + ")");
}
else if (nodeData == 3) {
tempLK = tempData;
//tempLKreportMin = minute();
if (tempLK == tempLKlast) {
++tempLKmatch;
}
else {
tempLKmatch = 0;
tempLKlast = tempLK;
}
//Serial.println(String("[") + currentTime + "] LK:" + tempLK + "F (" + tempLKmatch + "/" + tempLKreportMin + "m)");
Serial.println(String("[") + currentTime + "] LK:" + tempLK + "F (" + tempLKmatch + ")");
}
else if (nodeData == 4) {
tempMK = tempData;
//tempMKreportMin = minute();
if (tempMK == tempMKlast) {
++tempMKmatch;
}
else {
tempMKmatch = 0;
tempMKlast = tempMK;
}
//Serial.println(String("[") + currentTime + "] MK:" + tempMK + "F (" + tempMKmatch + "/" + tempMKreportMin + "m)");
Serial.println(String("[") + currentTime + "] MK:" + tempMK + "F (" + tempMKmatch + ")");
}
}
BLYNK_WRITE(V39) // Input from slider in app to set setpoint
{
setpointTemp = param.asInt();
/*DEBUG*/Serial.println(String("[") + millis() + "] setpointTemp = " + setpointTemp);
}
void tempWatcher() {
double tempArray[5] = {0, tempAT, tempKK, tempLK, tempMK}; // This starts with 0, since AT is Node01, KK is Node02, etc.
// Evaluates which room is the hottest
for (i = 0; i < 5; i++) { // If 0 skip, then look at tempAT and other rooms.
if (tempArray[i] > maxT) { // Compare each room to maxT and if higher,
maxT = tempArray[i]; // store that room's temp as maxT.
if (!coolingMode) { // Now if cooling is off,
highRoom = i; // set the index number (i) as the high room. This will setup this particular room as the target to cool (control watches this room to determine when to turn off).
}
}
if (i == 0) { // When we're back to the top of the order, reset maxT, otherwise it would just always hold the highest temperature since the WeMos was reset!
maxT = 0;
}
}
String highRoomName; // Gives a "proper" room name in lieu of node for use in app labels, etc.
if (highRoom == 1) {
highRoomName = "House";
}
else if (highRoom == 2) {
highRoomName = "KK";
}
else if (highRoom == 3) {
highRoomName = "LK";
}
else if (highRoom == 4) {
highRoomName = "MK";
}
if (controllingRoom == 1 && !coolingMode && setpointTemp != 0 && ( tempArray[highRoom] >= setpointTemp + triggerTemp) ) {
/*DEBUG*/Serial.println(String("[") + currentTime + "] Cooling started by " + highRoomName + " when it reached " + tempArray[highRoom] + "F. Shuts off at " + (setpointTemp - tempDiff) + "F.");
Blynk.setProperty(V16, "label", String("Status: Started by ") + highRoomName + " when it reached " + tempArray[highRoom] + "F. Shuts off at " + (setpointTemp - tempDiff) + "F.") ;
digitalWrite(coolingRelay, LOW);
coolingMode = true;
}
else if (controllingRoom == 1 && coolingMode && setpointTemp != 0 && ( tempArray[highRoom] <= setpointTemp - tempDiff) ) {
/*DEBUG*/Serial.println(String("[") + currentTime + "] Cooling stopped by " + highRoomName + " b/c " + tempArray[highRoom] + " <= " + (setpointTemp - tempDiff));
Blynk.setProperty(V16, "label", "Status:");
digitalWrite(coolingRelay, HIGH);
coolingMode = false;
overrunFlag = false;
}
// SAFETY: Turn off HVAC it it runs over 2 hours
if (currentRunSec > 7200 && coolingMode) {
shutdownHVACoverrun();
}
}
void shutdownHVACoverrun() {
//Blynk.setProperty(V16, "label", String("Status: ") + currentTime + " HVAC SHUTDOWN: Ran longer than 3 hours.") ;
//coolingMode = false;
//Blynk.virtualWrite(V40, "pick", 2);
//Blynk.virtualWrite(V40, 2);
//Blynk.syncVirtual(V40);
if (!overrunFlag) {
Blynk.notify(String(currentTime) + " WARNING: HVAC has run for 2 hours.");
overrunFlag = true;
}
}
// Set which room is controlling HVAC via the app's menu
BLYNK_WRITE(V40) {
switch (param.asInt())
{
case 1: { // House t-stat in control
/*DEBUG*/Serial.println(String("[") + currentTime + "] House tstat in control model selected");
controllingRoom = 0; // This number is node number
/*DEBUG*/Serial.println(String("[") + currentTime + "] controllingRoom = 0");
timer.disable(tempWatcherTimer);
/*DEBUG*/Serial.println(String("[") + currentTime + "] tempWatcherTimer disabled");
digitalWrite(fanRelay, HIGH);
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(bypassRelay, HIGH);
break;
}
case 2: { // Manual fan-only
/*DEBUG*/Serial.println(String("[") + currentTime + "] Manual fan only mode selected");
controllingRoom = 0;
/*DEBUG*/Serial.println(String("[") + currentTime + "] controllingRoom = 0");
timer.disable(tempWatcherTimer);
/*DEBUG*/Serial.println(String("[") + currentTime + "] tempWatcherTimer disabled");
digitalWrite(fanRelay, LOW);
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(bypassRelay, LOW);
break;
}
case 3: { // Whole-house cooling
/*DEBUG*/Serial.println(String("[") + currentTime + "] Whole house cooling mode selected");
controllingRoom = 1;
/*DEBUG*/Serial.println(String("[") + currentTime + "] controllingRoom = 1 (whole-house)");
timer.enable(tempWatcherTimer);
/*DEBUG*/Serial.println(String("[") + currentTime + "] tempWatcherTimer enabled");
coolingMode = false; // This sets up the unit to correctly watch room temps (seems reversed but it isn't)
digitalWrite(fanRelay, HIGH);
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(bypassRelay, LOW);
break;
}
case 4: { // KK cooling
controllingRoom = 2;
timer.enable(tempWatcherTimer);
digitalWrite(fanRelay, HIGH);
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(bypassRelay, LOW);
break;
}
case 5: { // LK cooling
controllingRoom = 3;
timer.enable(tempWatcherTimer);
digitalWrite(fanRelay, HIGH);
digitalWrite(coolingRelay, HIGH);
digitalWrite(heatingRelay, HIGH);
digitalWrite(bypassRelay, LOW);
break;
}
}
}
// END CONTROL SECTION
// BEGIN STARTUP SEQUENCE
void startupSync() {
Blynk.virtualWrite(V40, "pick", 1);
Blynk.syncVirtual(V11, V39, V40, V110, V111, V112);
}
BLYNK_WRITE(V11)
{
int filterUseMin = param.asInt(); // Doing this because there is no param.asLong
filterUseSec = filterUseMin * 60;
}
BLYNK_WRITE(V110)
{
todaysRuns = param.asInt();
}
BLYNK_WRITE(V111)
{
todaysRuntimeMin = param.asInt(); // Doing this because there is no param.asLong
todaysRuntimeSec = todaysRuntimeMin * 60L;
}
BLYNK_WRITE(V112)
{
yesterdaysRuntimeMin = param.asInt();
yesterdaysRuntimeSec = yesterdaysRuntimeMin * 60L;
// Updates the "Yesterday's runtime" display (at startup)
if (yesterdaysRuntimeSec == 0) {
Blynk.virtualWrite(V14, "None");
}
else {
yesterdaysRuntimeMin = yesterdaysRuntimeSec / 60;
Blynk.virtualWrite(V14, String(yesterdaysRuntimeMin) + " minutes");
}
}
void startTimers() {
timer.enable(fanStatusTimer);
timer.enable(setClockTimeTimer);
timer.enable(tempDisplayTimer);
timer.enable(statusDisplayTimer);
}
// END STARTUP SEQUENCE
void fanStatus() {
if (digitalRead(fanPin) == LOW) { // If fan-only mode is running
fanOnly = true; // set that mode and
++filterUseSec; // count seconds of filter use.
}
else {
fanOnly = false;
}
if (digitalRead(blowerPin) == LOW) { // If heating or cooling is running
fanCooling = true; // set those modes,
fanHeating = true;
++todaysRuntimeSec; // accumulated seconds it's ran today,
++filterUseSec; // count seconds of filter use,
++currentRunSec; // count seconds of current run (SAFETY),
}
else { // otherwise "turn off" those modes,
fanCooling = false;
fanHeating = false;
currentRunSec = 0; // and reset current run counter.
}
// Sets the start/end time and date when the blower starts or stops
if (digitalRead(blowerPin) == LOW && ( changeFlag || !ranOnce) ) { // If heating or cooling is running, and was previously off (or the WeMos just started up)
changeTimeDate = currentTimeDate; // set start time,
changeFlag = false; // use a flag to keep this process from happening again ("locking" the time/date for display), and
ranOnce = true; // indicate that ranOnce... ran... once!
}
else if (digitalRead(blowerPin) == HIGH && !changeFlag) { // If heating/cooling is off, and was previously off (or the WeMos just started up (no need for ranOnce as changeFlag is false at startup))
changeTimeDate = currentTimeDate; // set end time and
changeFlag = true; // lock out this process with flag. Now,
if (ranOnce) { // since I'm counting a run during an end event, I don't want a WeMos startup to register as a run, so I'm locking that out here, but
++todaysRuns;
}
else {
ranOnce = true; // unlocking here.
}
}
if (todaysDate != day()) { // At the end of the day
yesterdaysRuntimeSec = todaysRuntimeSec; // move today's runcount to yesterday,
todaysRuntimeSec = 0; // reset today's runtime, and
todaysRuns = 0; // reset today's number of runs.
coolingCounter = 0;
heatingCounter = 0;
todaysDate = day();
}
}
void tempDisplay() {
sensors.requestTemperatures(); // Polls the temperature sensors
tempRA = sensors.getTempF(ds18b20RA);
tempSA = sensors.getTempF(ds18b20SA);
if (fanCooling || fanHeating) {
Blynk.virtualWrite(V0, tempRA); // Display temperatures in app
Blynk.virtualWrite(V1, tempSA);
}
else if (fanOnly) {
Blynk.virtualWrite(V0, "FAN");
Blynk.virtualWrite(V1, "FAN");
}
else {
Blynk.virtualWrite(V0, "OFF");
Blynk.virtualWrite(V1, "OFF");
}
}
void statusDisplay() {
// Updates the primary "Status" display
if (fanCooling || fanHeating ) {
currentStatus = String("HVAC ON since ") + changeTimeDate; // I'm using this string because I need to sync this back after startup. I need to sync it because status is not static, it's refreshed at interval.
Blynk.virtualWrite(V16, currentStatus);
}
else if (!fanCooling || !fanHeating) {
currentStatus = String("HVAC OFF since ") + changeTimeDate;
Blynk.virtualWrite(V16, currentStatus);
}
// Updates the "Today's runtime" display
if (todaysRuntimeSec == 0) {
Blynk.virtualWrite(V15, "None"); // Yesterday runtime label
}
else {
todaysRuntimeMin = todaysRuntimeSec / 60;
Blynk.virtualWrite(V15, String(todaysRuntimeMin) + " mins (" + todaysRuns + " runs)");
}
}
void longStatusDisplay() {
int filterUseHr = filterUseSec / 3600;
Blynk.virtualWrite(V10, String(300 - filterUseHr) + " hours");
// Updates the "Yesterday's runtime" display
if (yesterdaysRuntimeSec == 0) {
Blynk.virtualWrite(V14, "None"); // Yesterday runtime label
}
else {
yesterdaysRuntimeMin = yesterdaysRuntimeSec / 60;
Blynk.virtualWrite(V14, String(yesterdaysRuntimeMin) + " minutes");
}
}
void setClockTime() {
if (year() != 1970) // Doesn't start until RTC is set correctly.
{
// Below gives me leading zeros on minutes and AM/PM.
if (minute() > 9 && hour() > 11) {
currentTimeDate = String(hourFormat12()) + ":" + minute() + "PM on " + month() + "/" + day();
}
else if (minute() < 10 && hour() > 11) {
currentTimeDate = String(hourFormat12()) + ":0" + minute() + "PM on " + month() + "/" + day();
}
else if (minute() > 9 && hour() < 12) {
currentTimeDate = String(hourFormat12()) + ":" + minute() + "AM on " + month() + "/" + day();
}
else if (minute() < 10 && hour() < 12) {
currentTimeDate = String(hourFormat12()) + ":0" + minute() + "AM on " + month() + "/" + day();
}
if (minute() > 9 && hour() > 11) {
currentTime = String(hourFormat12()) + ":" + minute() + "PM";
}
else if (minute() < 10 && hour() > 11) {
currentTime = String(hourFormat12()) + ":0" + minute() + "PM";
}
else if (minute() > 9 && hour() < 12) {
currentTime = String(hourFormat12()) + ":" + minute() + "AM";
}
else if (minute() < 10 && hour() < 12) {
currentTime = String(hourFormat12()) + ":0" + minute() + "AM";
}
}
}
void updateVpinData1() {
Blynk.virtualWrite(V110, todaysRuns); // Stores how many times the unit has started today
Blynk.virtualWrite(V111, todaysRuntimeMin); // Stores many minutes the HVAC ran today
timer.setTimeout(5002, updateVpinData2);
}
void updateVpinData2() {
Blynk.virtualWrite(V112, yesterdaysRuntimeMin); // Yesterday's runtime in minutes
Blynk.virtualWrite(V11, filterUseSec / 60); // How many minutes the installed air filter has been used
// Counts minutes of cooling or heating to support the language used in the nightly tweet
if (fanCooling || fanHeating) {
if (tempRA > tempSA) {
++coolingCounter;
}
else {
++heatingCounter;
}
}
if (coolingCounter == 0 && heatingCounter == 0) {
Blynk.virtualWrite(V38, "NONE");
}
else if (coolingCounter > heatingCounter) {
Blynk.virtualWrite(V38, "COOL");
}
else if (coolingCounter < heatingCounter) {
Blynk.virtualWrite(V38, "HEAT");
}
}
BLYNK_WRITE(V18) // Filter change mode
{
int pinData = param.asInt();
if (pinData == 0) // Triggers when button is released only
{
filterChangeMode = true;
terminal.println(""); terminal.println("");
terminal.println(" ~~ A/C Filter Status Mode ~~"); terminal.println(" ");
terminal.println("Was the filter just changed (y/n)?"); terminal.println(" ");
terminal.flush();
}
}
BLYNK_WRITE(V26) // Resets filter timer
{
if ( (String("y") == param.asStr() || String("Y") == param.asStr()) && filterChangeMode) {
filterUseSec = 0;
terminal.println(" "); terminal.println("Filter timer reset!"); terminal.println(" ");
filterChangeMode = false;
int filterUseHr = filterUseSec / 3600;
Blynk.virtualWrite(V10, String(300 - filterUseHr) + " hours");
}
else if ( (String("n") == param.asStr() || String("N") == param.asStr()) && filterChangeMode) {
terminal.println(" "); terminal.println("Filter change cancelled."); terminal.println(" ");
filterChangeMode = false;
}
terminal.flush();
}
BLYNK_WRITE(V27) // App button to report uptime
{
int pinData = param.asInt();
if (pinData == 0) // Triggers when button is released only
{
long minDur = millis() / 60000L;
long hourDur = millis() / 3600000L;
terminal.println(" "); terminal.println(" "); terminal.println(" "); terminal.println(" ");
terminal.println(" "); terminal.println(" "); terminal.println(" "); terminal.println(" ");
terminal.println("------------ UPTIME REPORT ------------");
if (minDur < 121)
{
terminal.print(String("HVAC: ") + minDur + " min/");
terminal.print(WiFi.RSSI());
terminal.print("/");
terminal.println(WiFi.localIP());
}
else if (minDur > 120)
{
terminal.print(String("HVAC: ") + hourDur + " hrs/");
terminal.print(WiFi.RSSI());
terminal.print("/");
terminal.println(WiFi.localIP());
}
terminal.flush();
}
}