Intesis WMP Gateway

Introduction

IntesisWMPGateway is a "plug-in" for for Vera home automation controllers that mimics the behavior of a standard heating/cooling thermostat and uses the Intesis WMP communications protocol to send commands and receive status from an Intesis WMP gateway device.

The IntesisWMPGateway plug-in works with the following Intesis devices: IS-IR-WMP-1, ME-AC-WMP-1, DK-AC-WMP-1, MH-AC-WMP-1, MH-RC-WMP-1, TD-RC-WMP-1, PA-AC-WMP-1, PA-RC2-WMP-1, LG-RC-WMP-1, FJ-RC-WMP-1. The plug-in uses the local WMP interface for communication (uses TCP port 3310). Note that devices that use Intesis cloud service for control do not work, even though they may have "WMP" in the product model. A separate plug-in is planned for these devices.

IntesisWMPGateway works with ALTUI, but does not work with openLuup at this time.

IntesisWMPGateway is written and supported by Patrick Rigney, aka rigpapa on the Vera forums. If you find the project useful, please consider supporting my work a small donation at MakerSupport.com.

For more information on Intesis WMP Gateways, visit the Intesis site. For more information on Vera home automation controllers, Vera Ltd's site.

Installation

Installation of the plug-in is through the usual mechanisms for Vera controllers: through the Vera plugin catalog, or by downloading the plugin files from the project's GitHub repository.

Installation through Vera

To install the plug-in from the Vera plug-in catalog:

  1. Open the Vera UI on your desktop computer;
  2. Click on Apps in the left navigation menu;
  3. Click on Install apps;
  4. Type "Intesis" into the search box and click "Search app";
  5. Choose the "Intesis WMP Gateway" app.

The plug-in will be installed, and the first device created. Each gateway device should have a corresponding Vera device (instance of the plug-in). If you have more than one gateway device, find the Intesis WMP Gateway app under the Apps > My apps section of the UI, click the "Details" button, and then clock the "Create another" button to create an additional Vera device.

Before you can use the device, you must configure the IP address of your gateway in the device data. See Configuration, below.

Installation from GitHub

Warning: this method is for experienced users only. Incorrectly uploading files to your Vera controller can cause problems, up to and including bricking the controller. Proceed at your own risk.

To install from GitHub, download a release from the project's GitHub repository. Unzip it, and then upload the release files to your Vera using the uploader found in the UI under Apps > Develop apps > Luup files. You should turn off the "Restart Luup after upload" checkbox until uploading the last of the files. Turn it on for the last file.

Configuration

If you are coming from a fresh installation of the plug-in, or have just created another device instance, reload Luup and flush your browser cache:

  1. Go to Apps > Develop apps > Test Luup code (Lua);
  2. Type luup.reload() into the text box and click the "GO" button;
  3. Do a CTRL-F5 or equivalent (browser-dependent) to refresh the Vera UI with a flush of cached data.

Operation

When first installed, the IntesisWMPGateway plugin will initiate network discovery and attempt to locate your compatible IntesisBox devices. There will be several Luup reloads during this process as devices are found, and as is frequently the case in Vera, a full refresh/cache flush of your browser will be necessary to consistently display all of the discovered devices.

The "Intesis WMP Gateway" device represents the interface and controller for all of the IntesisBox devices. There is normally only one such device, and it is the parent for all other devices created by the plugin. Clicking on the arrow in the Vera dashboard to access the gateway's control panel will give you three options for launching network discovery. The first will run network broadcast discovery, which is the first method you should try if the plugin did not find all of your devices. The second option is MAC discovery, where a MAC address is entered (see the label on the IntesisBox device) and the plugin searches for that device specifically. The third is IP discovery, which may be used if the IP address of the device is known.

Each discovered IntesisBox device presents as a heating/cooling thermostat in the Vera UI. These devices are child devices of the parent gateway device, although this association is not readily apparent from the UI, and in most cases is not relevant for the typical Vera user (Lua scripters will care, though). Buttons labeled "Off", "Heat", "Cool", "Auto", "Dry" and "Fan" are used to change the heating/cooling unit's operating mode. The "spinner" control (up/down arrows) is used to change the setpoint temperature. To the right of the spinner is the current temperature as reported by the gateway. If you click the arrow in the device panel you land on the "Control" tab, and an expanded control UI is presented. The operating mode and setpoint controls are the similar, but there additional controls for fan speed and vane position.

NOTE: Since the IntesisBox devices are interfaces for a large number of heating/cooling units by various manufacturers, the capabilities of each device vary considerably. For many devices, some UI buttons will have no effect, or have side-effects to other functions; in some cases, the buttons may affect one unit differently from the way they affect another. This is not a defect of the plug-in, but rather the response to Intesis' interpretation of how to best control the heating/cooling unit given its capabilities.

Actions

The plugin creates two device types and services:

  1. Type , service urn:toggledbits-com:serviceId:IntesisWMPGateway1, which
  2. Type , service urn:toggledbits-com:serviceId:IntesisWMPDevice1, which contains the state and actions associated with each IntesisBox device;

IntesisGateway1 Service Actions and Variables

The IntesisGateway1 service, which must be referenced using its full name urn:toggledbits-com:serviceId:IntesisWMPGateway1, contains the state and actions associated with the gateway device itself. It is associated with the urn:schemas-toggledbits-com:device:IntesisWMPGateway:1 device type.

The following actions are implemented under this service:

Action: RunDiscovery

This action launches broadcast discovery, and adds any newly-discovered compatible IntesisBox devices to the configuration. Discovery lasts for 30 seconds, and runs asynchronously (all other tasks and jobs continue during discovery).

Action: DiscoverMAC

This action starts discovery for a given MAC address, passed in the MACAddress parameter. This is useful because the MAC addresses are printed on a label on the back of the device, and if the device is connected to the same LAN as the Vera, is likely discoverable by this address. If the device is found and compatible, it will be added to the configuration.

Action: DiscoverIP

This action starts discovery for a given IP address. If communication with the device can be established at the given address (provided in the IPAddreess parameter), and the device is compatible, it will be added to the configuration.

Action: SetDebug

This action enables debugging to the Vera log, which increases the verbosity of the plugins information output. It takes a single parameter, debug, which must be either 0 or 1 in numeric or string form.

Variable: PingInterval

PingInterval is the time between pings to the gateway device. These pings are used to keep the TCP connection up between the Vera and the gateway. The value of this variable is in seconds, and the default is 15. It is not recommended to set this value lower than 5 or greater than 120. If the value is too high (which could be any value greater than the default), disconnects may result, requiring a Luup reload for recovery.

Variable: RefreshInterval

RefreshInterval is the time between full queries for data from the gateway. Periodically, the plug-in will make a query for all current gateway status parameters, to ensure that the Vera plug-in and UI are in sync with the gateway. This value is in seconds, and the default is 60. It is not recommended to set this value lower than the ping interval (above).

IntesisDevice1 Service Actions and Variables

The IntesisDevice1 service, which must be referenced using its full name urn:toggledbits-com:serviceId:IntesisWMPDevice1, contains the state and actions associated with IntesisBox devices. It is associated with the urn:schemas-toggledbits-com:device:IntesisWMPDevice:1 device type.

These devices also implement actions and variables of HVAC_OperatingState1, HVAC_FanState1, TemperatureSetpoint1, and TemperatureSensor1. See Other Services, below, for detail.

The following actions are implemented under by the IntesisDevice1 service specifically:

Action: SetName/GetName

The SetName action may be used to change the name of the IntesisBox device. The name of the device itself changes, but this does not change the name of the Vera device. Use Vera's UI tools for that. When using SetName, the new name must be passed in a parameter named NewName (capitalization exactly as shown). The GetName action returns the current name of the gateway device in an argument named Name.

    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "SetName", { NewName="Bedroom" }, deviceNumber )

Action: FanSpeedUp/FanSpeedDown

The FanSpeedUp and FanSpeedDown actions adjust the fan speed up or down, respectively, within the limits of the gateway and the configured heating/cooling unit. These actions take no parameters.

    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "FanSpeedUp", { }, deviceNumber )

Action: SetCurrentFanSpeed/GetCurrentFanSpeed

The SetCurrentFanSpeed action takes a single parameter, NewCurrentFanSpeed, which sets the fan speed at the gateway. The new fan speed is expected to be an integer in the range the gateway and heating/cooling unit can accept (e.g. 1 to 5). If out of range, the value may be clamped at the limits. Passing an empty value or 0 will cause the fan speed mode to be set to "Auto" if the gateway supports it for the configured heating/cooling unit.

The GetCurrentFanSpeed action returns a single argument, CurrentFanSpeed, with the gateway's last-reported fan speed (an integer or "Auto").

    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "SetCurrentFanSpeed", { NewCurrentFanSpeed=2 }, deviceNumber )
    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "SetCurrentFanSpeed", { NewCurrentFanSpeed="Auto" }, deviceNumber )

Action: VaneUp, VaneDown, VaneLeft, VaneRight

The Vane___ actions signal the gateway to change the vane position. These actions take no parameters. Position is changed relative to current position, within the limits of the air handling unit.

    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "VaneUp", { }, deviceNumber )
    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "VaneDown", { }, deviceNumber )
    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "VaneLeft", { }, deviceNumber )
    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "VaneRight", { }, deviceNumber )

Action: SetLeftRightVanePosition, GetLeftRightVanePosition, SetUpDownVanePosition, GetUpDownVanePosition

The Set___VanePosition actions set the vane position of the air handling unit to the specified setting, if possible. These actions take a single parameter, NewPosition, which must be an integer greater than zero (limits are determined by the air handler and vary from device to device), or "Auto". The value zero is also interpreted as "Auto".

    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "SetLeftRightVanePosition", { NewPosition=3 }, deviceNumber )
    luup.call_action( "urn:toggledbits-com:serviceId:IntesisWMPGateway1", "SetUpDownVanePosition", { NewPosition="Auto" }, deviceNumber )

Action: GetSignalStrength

The GetSignalStrength action returns a single argument (SignalDB) containing the WiFi signal strength reported by the gateway. This is usually a negative integer (< -96 is a bad/unacceptable signal; -86 to -95 is weak; -85 to -81 is good; -80 to -71 is very good; and anything >= -70 is excellent).

Variable: ForceUnits

By default, the plug-in will adjust its UI to display temperatures in the default units configured for the Vera controller. If the Vera's units are changed, the plug-in will self-reconfigure. If the user has some reason to need the plug-in to present its interfaces in units over than the Vera's configured unit, setting ForceUnits to "C" or "F" will cause the plug-in to display Fahrenheit or Celsius, respectively.

Note that this variable is not automatically created with the device. You will need to create it using the "Create Service" tab in the device's Advanced settings page (not the gateway device--the IntesisBox thermostat-looking device). The service name is (copy-paste recommended) urn:toggledbits-com:serviceId:IntesisWMPDevice1.

Each IntesisDevice1 instance may have its own copy of this variable, thus making it possible that the displayed units of each thermostat may be different, as a user may need.

Other Services

In addition to the above services, the IntesisWMPGateway plug-in implements the following "standard" services for thermostats (IntesisDevice1 devices):

  • urn:upnp-org:serviceId:HVAC_UserOperatingMode1: SetModeTarget (Off, AutoChangeOver, HeatOn, CoolOn), GetModeTarget, GetModeStatus
  • urn:upnp-org:serviceId:HVAC_FanOperatingMode1: SetMode (Auto, ContinuousOn), GetMode
  • urn:upnp-org:serviceId:TemperatureSetpoint1: SetCurrentSetpoint, GetCurrentSetpoint

The plug-in also provides many of the state variables behind these services. In addition, the plug-in maintains the CurrentTemperature state variable of the urn:upnp-org:serviceId:TemperatureSensor1 service (current ambient temperature as reported by the gateway).

IMPORTANT: The model for handling fan mode differs significantly between Intesis and Vera. In Vera/UPnP, setting the fan mode to ContinuousOn turns the fan on, but does not change the operating mode of the air handling unit. For example, with the fan mode set to ContinuousOn, if the AHU is cooling, it continues to cool until setpoint is achieved, at which time cooling shuts down but the fan continues to operate. In Intesis, to get continuous operation of the fan, one sets the (operating) mode to "Fan", which will stop the AHU from heating or cooling. Because of this, the plugin does not react to the SetMode action in service urn:upnp-org:serviceId:HVAC_FanOperatingMode1 (it is quietly ignored). In addition, the FanStatus state can only be deduced in the "Off" or "FanOnly" operating modes, in which case the status will be "Off" or "On" respectively; in all other cases it will be "Unknown".

IMPORTANT: Also note that I take a different view of ModeTarget and ModeStatus (in HVAC_UserOperatingMode1) from Vera. Vera mostly (although not consistently) sees the two as nearly equivalent, with the latter (ModeStatus) following ModeTarget. That is, if ModeTarget is set to "HeatOn", ModeStatus also becomes "HeatOn". This is not entirely in keeping with UPnP in my opinion. UPnP says, in essence, that ModeTarget is the desired operating mode, and ModeStatus is the current operating state. This may sound like the same thing, except that UPnP takes status much more temporally than Vera; that is, UPnP says if ModeTarget is "HeatOn", but there is no call for heat because the temperature is within the setpoint hysteresis (aka the "deadband"), then ModeStatus may be "InDeadBand", indicating that the unit is currently not doing anything. When the current temperature deviates too far from the setpoint and the call for heat comes, then ModeStatus goes to "HeatOn", indicating that the air handling unit is then providing heat. In other words, Vera says ModeStatus is effectively a confirmation of ModeTarget, while UPnP says that ModeTarget is the goal, and ModeStatus reflects the at-the-moment state of the unit's activity toward the goal. Vera, then, has had to introduce a new non-standard variable (ModeState) to communicate what could and should be communicated in the service-standard variable.

IntesisERRSTATUS and IntesisERRCODE

The plugin will store the values of any ERRSTATUS and ERRCODE reports from the gateway device. Because the meaning of these codes varies from device to device, the plugin does not act on them, but since they are stored, user-provided scripts could interpret the values and react using specific knowledge of the air handling unit installed.

ImperiHome Integration

ImperiHome does not, by default, detect many plugin devices, including ImperiHome WMP Gateway. However, it is possible to configure this plugin for use with ImperiHome, as the plugin implements the ImperiHome ISS API.

To connect Intesis WMP Gateway to ImperiHome:

  1. In ImperiHome, go into My Objects
  2. Click Add a new object
  3. Choose ImperiHome Standard System
  4. In the Local base API field, enter http://your-vera-local-ip/port_3480/data_request?id=lr_IntesisWMPGateway&command=ISS
  5. Click Next to connect.

ImperiHome should then populate your groups with your Intesis WMP Gateway plugin devices.