From e7543e199591c24175c4a06beec15611ce4b5a5b Mon Sep 17 00:00:00 2001 From: Matti Vaittinen Date: Thu, 18 Nov 2021 13:49:08 +0200 Subject: [PATCH] regulator: bd718x7: Use rohm generic restricted voltage setting Use common restricted voltage setting instead of implementing own. Signed-off-by: Matti Vaittinen Link: https://lore.kernel.org/r/5a0ee14852802690241568a29ed19ff9550b0b08.1637233864.git.matti.vaittinen@fi.rohmeurope.com Signed-off-by: Mark Brown --- drivers/regulator/bd718x7-regulator.c | 29 ++++----------------------- 1 file changed, 4 insertions(+), 25 deletions(-) diff --git a/drivers/regulator/bd718x7-regulator.c b/drivers/regulator/bd718x7-regulator.c index d60fccedb250d4..00efb18a836cd4 100644 --- a/drivers/regulator/bd718x7-regulator.c +++ b/drivers/regulator/bd718x7-regulator.c @@ -125,27 +125,6 @@ static int bd71837_get_buck34_enable_hwctrl(struct regulator_dev *rdev) return !!(BD718XX_BUCK_RUN_ON & val); } -/* - * On BD71837 (not on BD71847, BD71850, ...) - * Bucks 1 to 4 support DVS. PWM mode is used when voltage is changed. - * Bucks 5 to 8 and LDOs can use PFM and must be disabled when voltage - * is changed. Hence we return -EBUSY for these if voltage is changed - * when BUCK/LDO is enabled. - * - * On BD71847, BD71850, ... The LDO voltage can be changed when LDO is - * enabled. But if voltage is increased the LDO power-good monitoring - * must be disabled for the duration of changing + 1mS to ensure voltage - * has reached the higher level before HW does next under voltage detection - * cycle. - */ -static int bd71837_set_voltage_sel_restricted(struct regulator_dev *rdev, - unsigned int sel) -{ - if (rdev->desc->ops->is_enabled(rdev)) - return -EBUSY; - - return regulator_set_voltage_sel_regmap(rdev, sel); -} static void voltage_change_done(struct regulator_dev *rdev, unsigned int sel, unsigned int *mask) @@ -642,22 +621,22 @@ BD718XX_OPS(bd71837_pickable_range_buck_ops, bd718x7_set_buck_ovp); BD718XX_OPS(bd71837_ldo_regulator_ops, regulator_list_voltage_linear_range, - NULL, bd71837_set_voltage_sel_restricted, + NULL, rohm_regulator_set_voltage_sel_restricted, regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp, NULL); BD718XX_OPS(bd71837_ldo_regulator_nolinear_ops, regulator_list_voltage_table, - NULL, bd71837_set_voltage_sel_restricted, + NULL, rohm_regulator_set_voltage_sel_restricted, regulator_get_voltage_sel_regmap, NULL, NULL, bd718x7_set_ldo_uvp, NULL); BD718XX_OPS(bd71837_buck_regulator_ops, regulator_list_voltage_linear_range, - NULL, bd71837_set_voltage_sel_restricted, + NULL, rohm_regulator_set_voltage_sel_restricted, regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel, NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp); BD718XX_OPS(bd71837_buck_regulator_nolinear_ops, regulator_list_voltage_table, - regulator_map_voltage_ascend, bd71837_set_voltage_sel_restricted, + regulator_map_voltage_ascend, rohm_regulator_set_voltage_sel_restricted, regulator_get_voltage_sel_regmap, regulator_set_voltage_time_sel, NULL, bd718x7_set_buck_uvp, bd718x7_set_buck_ovp); /*