The bootstrapper\'s variables are not determined after reboot #3733

Closed
wixbot opened this Issue Aug 13, 2012 · 2 comments

Comments

Projects
None yet
1 participant
Collaborator

wixbot commented Aug 13, 2012

After reboot in middle of chain user defined variables' values like "InstallFolder" are not determined.

...
[0BE0:0BF0][2012-08-13T14:39:44]: Setting string variable 'InstallFolder' to value 'c:\BundleDir'
...

[0BE0:0BE4][2012-08-13T14:39:51]: Restarting computer...

...
Here InstallFolder=""

Originally opened by warlock78 from http://sourceforge.net/p/wix/bugs/3053/

Collaborator

wixbot commented Nov 21, 2012

Sources and logs for bug

Collaborator

wixbot commented Oct 22, 2013

To persist variables after reboot, set Variable/@persisted="yes".

Originally posted by barnson
Resolution set to fixed
Status changed from Untriaged to Resolved

@wixbot wixbot added bug burn labels Dec 20, 2015

@wixbot wixbot added this to the v3.8 milestone Dec 20, 2015

@wixbot wixbot closed this Dec 20, 2015