Added state checks. Optimised SNMP queries.

  • Loading branch information...
commit 532d6c458f00f6da6530695a330a9149bd4faf88 1 parent 63f2a27
@wyrie authored
Showing with 183 additions and 172 deletions.
  1. +183 −172 check_snmp_supermicro.pl
View
355 check_snmp_supermicro.pl
@@ -1,6 +1,20 @@
#!/usr/bin/perl
# author: Scott Barr <gsbarr@gmail.com>
-# license: GPL - http://www.fsf.org/licenses/gpl.txt
+# This program is free software; you can redistribute it and/or modify
+# it under the terms of the GNU General Public License as published by
+# the Free Software Foundation; either version 2 of the License, or
+# (at your option) any later version.
+#
+# This program is distributed in the hope that it will be useful,
+# but WITHOUT ANY WARRANTY; without even the implied warranty of
+# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
+# GNU General Public License for more details.
+#
+# You should have received a copy of the GNU General Public License
+# along with this program; if not, write to the Free Software
+# Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston,
+# MA 02110-1301, USA.
+#
use strict;
require 5.10.0;
@@ -11,71 +25,54 @@
use Getopt::Long;
use Nagios::Plugin;
use vars qw(
- $opt_version
- $opt_timeout
- $opt_help
- $opt_host
- $opt_community
- $opt_verbose
- $opt_port
$snmp_session
- $PROGNAME
- $TIMEOUT
- $test_name
- $limits
$plugin
- %test_names
- $monitor_unit
- $criticals
- $warnings
- $unknowns
- $status
- @desc
- $monitor
- $monitor_index
+ $oid_prefix
+ %oid_map
+ $TIMEOUT
);
use version; our $VERSION = '2.0';
# --------------------------- globals -------------------------- #
-
-my %StatusOIDS=();
-my %Fans=();
-my %Voltages=();
+my %MonitoredItems=();
my @desc=();
+my $PROGNAME = "check_snmp_supermicro.pl";
+my $opt_verbose = undef;
+my $opt_host = 'localhost';
+my $opt_community = 'public';
+my $opt_port = 161;
+my %opt_test = ();
+my $criticals = q{};
+my $warnings = q{};
+my $unknowns = q{};
+my $status = q{};
+my $oid_prefix = ".1.3.6.1.4.1.10876.2.1.1.1.1.";
+my $monitor_unit = '';
+my $monitor_monitored = '';
+my $monitor_low = '';
+my $monitor_high = '';
-$PROGNAME = "check_snmp_supermicro.pl";
$plugin = Nagios::Plugin->new( shortname => $PROGNAME );
-$opt_verbose = undef;
-$opt_host = 'localhost';
-$opt_community = 'public';
-$opt_port = 161;
-$test_name = undef;
-$criticals = q{};
-$warnings = q{};
-$unknowns = q{};
-$status = q{};
-
-my $oid_prefix = ".1.3.6.1.4.1."; #Enterprises
- $oid_prefix .= "10876.2.1.1.1.1."; #Supermicro board
-
-
# ---------------------------- main ----------------------------- #
Getopt::Long::Configure( 'bundling' );
GetOptions(
'version|V' => sub { print "$PROGNAME version $VERSION\n"; exit 3; },
'verbose|v' => \$opt_verbose,
- 'help|h' => \$opt_help,
+ 'help|h' => sub { print help(); exit 3; },
'hostname|H=s' => \$opt_host,
'port|p=i' => \$opt_port,
'community|C=s' => \$opt_community,
'timeout|t=i' => \$TIMEOUT,
- 'test|T=s' => \%test_names,
+ 'test|T:s' => \%opt_test,
);
-if ( !%test_names || defined($opt_help) ) {
+if (!%opt_test) {
$plugin->nagios_exit(UNKNOWN, help());
}
+$SIG{'ALRM'} = sub {
+ $plugin->nagios_exit(UNKNOWN, "Timeout exceeded " . $TIMEOUT);
+};
alarm( $TIMEOUT ); # make sure we don't hang Nagios
my $snmp_error;
@@ -87,149 +84,136 @@
);
$plugin->nagios_exit(UNKNOWN, "SNMP Error: " . $snmp_error) unless (defined($snmp_session));
-if (defined($opt_verbose)) {
- $snmp_session->debug(-debug => 'DEBUG_ALL');
-}
-
-# Validate SNMP connection
-my $result = $snmp_session ->get_request("1.3.6.1.2.1.1.3.0"); #sysUpTime
-if (!defined($result)) {
- $plugin->nagios_exit(UNKNOWN, "SNMP Error: Please check connection settings.");
+if (defined($opt_verbose)) {
+ $snmp_session->debug(1);
}
# Populate the hash with valid monitor names and indexes
-my $count = 1;
-while ( $count ) {
- my $oid_name = $oid_prefix."2.".$count;
- my $oid_type = $oid_prefix."3.".$count;
-
- my $name = $snmp_session->get_request(-varbindlist => [$oid_name]);
- $name = ($name->{$oid_name});
- if (!defined($name) || $name eq 'noSuchInstance') {
- last;
- }
-
- my $type = $snmp_session->get_request(-varbindlist => [$oid_type]);
- $type = ($type->{$oid_type});
+my $result = $snmp_session->get_entries(-columns => [$oid_prefix."2"]);
+if (!defined($result)) {
+ $plugin->nagios_exit(UNKNOWN, "SNMP Error: ".$snmp_session->error());
+}
- $StatusOIDS{$name} = $count;
- $Fans{$name} = $count if ($type == 0);
- $Voltages{$name} = $count if ($type == 1);
- $count++;
+while ( my ($oid, $reading) = each(%{$result}) ) {
+ my $index = substr($oid, (rindex($oid,".")+1) );
+ $MonitoredItems{$reading} = $index;
}
-# Check parsed monitors or macros
-while ( ( $test_name, $limits ) = each %test_names ) {
+# Check parsed tests and filter hash for valid names
+my @indexes = grep { exists $MonitoredItems{$_} } keys %opt_test;
+
+for my $test_name (@indexes) {
+
+ my ($monitor_name, $monitor_type, $monitor_reading) = getMonitor($MonitoredItems{$test_name});
- my ( $warn, $crit ) = split /,/mx, $limits;
- if ( !defined($warn) ) {
- $plugin->nagios_exit(UNKNOWN, "No warning level found for monitor '$test_name'");
- }
+ # Get user warning level. Critical can be found from SuperDoctor.
+ my ( $warn, $crit ) = split /,/mx, $opt_test{$test_name};
+ $plugin->nagios_exit(UNKNOWN, "No warning level found for monitor '$test_name'") unless (defined($warn) || $monitor_type == 3);
- if ( $test_name ~~ %StatusOIDS ) {
-
- my $oid_template = $oid_prefix."%d.".$StatusOIDS{$test_name};
- my ($monitor_low, $monitor_high) = ('','');
-
- my $monitor_reading = SNMP_getvalue($snmp_session, sprintf($oid_template, 4));
- my $monitor_type = SNMP_getvalue($snmp_session, sprintf($oid_template, 3));
-
- given($monitor_type)
- {
- when(0) { # Fan speed
- $monitor_unit = "RPM";
-
- my $monitored = SNMP_getvalue($snmp_session, sprintf($oid_template, 10));
- if ($monitored == 0) {
- $plugin->nagios_exit(UNKNOWN, "The fan '$test_name' is not monitored.");
- }
-
- if (!$crit) {
- $crit = SNMP_getvalue($snmp_session, sprintf($oid_template, 6));
- }
-
- if ( $monitor_reading < $crit ) {
- $criticals = $criticals . " $test_name=$monitor_reading";
- }
- elsif ( $monitor_reading < $warn ) {
- $warnings = $warnings . " $test_name=$monitor_reading";
- }
+ given($monitor_type)
+ {
+ when(0) { # Fan speed
+ $monitor_unit = "RPM";
+ my ($monitor_low, $monitor_monitored) = getOids($MonitoredItems{$test_name}, ('low', 'monitored'));
+ $plugin->nagios_exit(UNKNOWN, "The fan '$test_name' is not monitored.") unless ($monitor_monitored == 1);
+
+ if (!$crit) {
+ $crit = $monitor_low;
}
- when (1) { # Voltage
- $monitor_unit = "V";
- my ($warn_low, $warn_high, $crit_low, $crit_high) = ('','','','');
- $monitor_reading = sprintf("%.2f", ($monitor_reading/1000));
-
- if (!$crit) {
- $crit = sprintf("%.2f", ( SNMP_getvalue($snmp_session, sprintf($oid_template, 6)) / 1000 ));
- $crit .= ':' . sprintf("%.2f", ( SNMP_getvalue($snmp_session, sprintf($oid_template, 5)) / 1000 ) );
- }
-
- if ($warn =~ m/^([\d.]+):([\d.]+)$/) {
- ($warn_low, $warn_high) = ($1,$2);
- } else {
- $plugin->nagios_exit(UNKNOWN, "Cannot identify low and high end of the warning level range required by '$test_name'");
- }
-
- if ($crit =~ m/^([\d.]+):([\d.]+)$/) {
- ($crit_low, $crit_high) = ($1,$2);
- } else {
- $plugin->nagios_exit(UNKNOWN, "Cannot identify low and high end of the critical level range required by '$test_name'");
- }
-
- if ( ($monitor_reading < $crit_low) || ($monitor_reading > $crit_high) ) {
- $criticals = $criticals . " $test_name=$monitor_reading";
- } elsif ( ($monitor_reading < $warn_low) || ($monitor_reading > $warn_high) ) {
- $warnings = $warnings . " $test_name=$monitor_reading";
- }
+
+ if ( $monitor_reading < $crit ) {
+ $criticals .= " $test_name";
}
- when (2) { # Temperature
- $monitor_unit = "C";
-
- if (!$crit) {
- $crit = SNMP_getvalue($snmp_session, sprintf($oid_template, 5));
- }
-
- if ( $monitor_reading > $crit ) {
- $criticals = $criticals . " $test_name=$monitor_reading";
- }
- elsif ( $monitor_reading > $warn ) {
- $warnings = $warnings . " $test_name=$monitor_reading";
- }
+ elsif ( $monitor_reading < $warn ) {
+ $warnings .= " $test_name";
}
- }
-
- $status = $status . "$test_name=$monitor_reading;$warn;$crit;;";
- push(@desc, "$test_name=$monitor_reading$monitor_unit");
-
- } elsif ($test_name eq 'fan-speeds') {
+ }
+ when (1) { # Voltage
+ $monitor_unit = "V";
+ my ($warn_low, $warn_high, $crit_low, $crit_high) = ('','','','');
+ $monitor_reading = sprintf("%.2f", ($monitor_reading/1000)); # Convert into V from mV.
+
+ my ($monitor_low, $monitor_high) = getOids($MonitoredItems{$test_name}, ('low', 'high'));
+
+ if (!$crit) {
+ $crit = sprintf("%.2f", ($monitor_low/1000)) . ':' . sprintf("%.2f", ($monitor_high/1000));
+ }
+
+ if ($warn =~ m/^([\d.]+):([\d.]+)$/) {
+ ($warn_low, $warn_high) = ($1,$2);
+ } else {
+ $plugin->nagios_exit(UNKNOWN, "Cannot identify low and high end of the warning level range required by '$test_name'");
+ }
+
+ if ($crit =~ m/^([\d.]+):([\d.]+)$/) {
+ ($crit_low, $crit_high) = ($1,$2);
+ } else {
+ $plugin->nagios_exit(UNKNOWN, "Cannot identify low and high end of the critical level range required by '$test_name'");
+ }
+
+ if ( ($monitor_reading < $crit_low) || ($monitor_reading > $crit_high) ) {
+ $criticals .= " $test_name";
+ } elsif ( ($monitor_reading < $warn_low) || ($monitor_reading > $warn_high) ) {
+ $warnings .= " $test_name";
+ }
+ }
+ when (2) { # Temperature
+ $monitor_unit = "C";
+ my ($monitor_high) = getOids($MonitoredItems{$test_name}, ('high'));
+
+ if (!$crit) {
+ $crit = $monitor_high;
+ }
+
+ if ( $monitor_reading > $crit ) {
+ $criticals .= " $test_name";
+ }
+ elsif ( $monitor_reading > $warn ) {
+ $warnings .= " $test_name";
+ }
+ }
+ when (3) { # Good (0) and bad (1) stuff i.e. Power supply
+ $criticals .= " $test_name" unless ($monitor_reading == 0);
+ }
+ }
- for my $monitor ( sort (keys %Fans) ) {
-
- my $oid_template = $oid_prefix."%d.".$Fans{$monitor};
- my $fan_monitored = SNMP_getvalue($snmp_session, sprintf($oid_template, 10));
- if ($fan_monitored == 0) {
- next;
- }
+ $status = $status . "$test_name=$monitor_reading;$warn;$crit;;";
+ push(@desc, "$test_name=$monitor_reading$monitor_unit");
+}
+
+if ('fan-speeds' ~~ %opt_test) {
+
+ my ( $warn, $crit ) = split /,/mx, $opt_test{'fan-speeds'};
+ $plugin->nagios_exit(UNKNOWN, "No warning level found for fan speeds") unless (defined($warn));
+
+ $result = $snmp_session->get_entries(-columns => [$oid_prefix."3"]);
+ if (!defined($result)) {
+ $plugin->nagios_exit(UNKNOWN, "SNMP Error: ".$snmp_session->error());
+ }
+
+ while ( my ($oid, $reading) = each(%{$result}) ) {
+ if ($reading == 0) {
- my $monitor_reading = SNMP_getvalue($snmp_session, sprintf($oid_template, 4));
+ my $index = substr($oid, (rindex($oid,".")+1) );
+ my ($monitor_name, $monitor_type, $monitor_reading, $monitor_low, $monitor_monitored) = getOids($index, ('name','type','value','low','monitored'));
+ next unless ($monitor_monitored == 1);
if (!$crit) {
- $crit = SNMP_getvalue($snmp_session, sprintf($oid_template, 6));
+ $crit = $monitor_low;
}
if ( $monitor_reading < $crit ) {
- $criticals = $criticals . " $monitor=$monitor_reading";
+ $criticals .= " $monitor_name";
}
elsif ( $monitor_reading < $warn ) {
- $warnings = $warnings . " $monitor=$monitor_reading";
+ $warnings .= " $monitor_name";
}
- $status = $status . "$monitor=$monitor_reading;$warn;$crit;;";
- push(@desc, "$monitor=${monitor_reading}RPM");
+ $status = $status . "$monitor_name=$monitor_reading;$warn;$crit;;";
+ push(@desc, "$monitor_name=${monitor_reading}RPM");
}
-
}
+
}
$snmp_session->close;
@@ -257,17 +241,39 @@
$plugin->nagios_exit(OK, "$desc$status");
# ---------------------------- Support methods ------------------ #
-sub SNMP_getvalue {
- my ($snmp_session,$oid) = @_;
-
- my $res = $snmp_session->get_request(
- -varbindlist => [$oid]);
+sub getOids {
+ my ($monitor_index, @monitor_attrs) = @_;
- if (!defined($res)) {
- $plugin->nagios_exit(UNKNOWN, "SNMP Error: " . $snmp_session->error);
+ my %oid_map = ( 'name' => $oid_prefix."2.".$monitor_index,
+ 'type' => $oid_prefix."3.".$monitor_index,
+ 'value' => $oid_prefix."4.".$monitor_index,
+ 'low' => $oid_prefix."6.".$monitor_index,
+ 'high' => $oid_prefix."5.".$monitor_index,
+ 'monitored' => $oid_prefix."10.".$monitor_index );
+ my @oids = ();
+
+ for my $attr (@monitor_attrs) {
+ if ($oid_map{$attr}) {
+ push(@oids, $oid_map{$attr});
+ }
+ }
+
+ my $res = $snmp_session->get_request( -varbindlist => \@oids);
+ $plugin->nagios_exit(UNKNOWN, "SNMP Error: " . $snmp_session->error()) unless (defined($res));
+
+ my @result = ();
+ for my $attr (@monitor_attrs) {
+ if ($oid_map{$attr}) {
+ push(@result, $res->{$oid_map{$attr}});
+ }
}
- return($res->{$oid});
+ return @result;
+}
+
+sub getMonitor {
+ my ($monitor_index) = @_;
+ return getOids($monitor_index, ('name','type','value'));
}
sub help {
@@ -285,15 +291,20 @@ sub help {
-v, --verbose
print extra debugging information
-T, --test
- Perform a test of the specified monitor.
+ Perform a test(s) of the specified monitor(s).
Example:
-T 'System Temperature'=50,60
will give a warning if the value of the monitor reaches 50 degrees and a critical status
if it reaches 60 degrees celcius. For voltage monitors define the lower:upper limits of
the warning and critical levels.
Example:
- --test 'CPU Core Voltage'=1.10:1.29,0.92:1.38
+ --test 'CPU Core Voltage'=1.10:1.29,0.92:1.38 or
+ -T '+5V Voltage'=4.69:5.20 -T '+5Vsb Voltage'=4.69:5.20
Critical levels may be omitted and will be substitued by the builtin limits set by Supermicro.
+ Some monitored items have states. For example: "Power Supply Failure" has a reading of Good or Bad.
+ These items can have warning and critical levels omiited and will raise critical when the state is bad.
+ Example:
+ -T 'Chassis Intrusion'
-h, --help
print this help message
-H, --hostname=HOST