I can not open "COM24" with luars232,but when I change the com port name to "COM4",luars232 open successfully.And I can open "COM24" with HyperTerminal (hypertrm.exe).
I examine the code of luars232,but have not found the reason,and I have not VS2005,so I just submit this issue here.
Thanks.
The text was updated successfully, but these errors were encountered:
Windows is crappy in this, serial ports 1-9 are valid names, but for ports above you need to use UNC name of the device - \.\COMxx, so please try to open the port with "\.\COM24" as device name and let me know if it helped. Thanks.
I can not open "COM24" with luars232,but when I change the com port name to "COM4",luars232 open successfully.And I can open "COM24" with HyperTerminal (hypertrm.exe).
I examine the code of luars232,but have not found the reason,and I have not VS2005,so I just submit this issue here.
Thanks.
The text was updated successfully, but these errors were encountered: