18:50:25.181737 T00110000 Read-Data Relative modulation level: 0.00 18:50:25.277586 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:26.186193 T801A0000 Read-Data DHW temperature: 0.00 18:50:26.276485 BE01A0000 Data-Inv DHW temperature: 0.00 18:50:27.178861 T80190000 Read-Data Boiler water temperature: 0.00 18:50:27.277842 B40192166 Read-Ack Boiler water temperature: 33.40 18:50:28.181038 T10013000 Write-Data Control setpoint: 48.00 18:50:28.322060 BD0013000 Write-Ack Control setpoint: 48.00 18:50:28.491075 SC: 18:50/3 18:50:29.179023 T00000300 Read-Data Status: 00000011 00000000 18:50:29.277304 B40000302 Read-Ack Status: 00000011 00000010 18:50:30.194581 T00110000 Read-Data Relative modulation level: 0.00 18:50:30.276674 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:31.176767 T801C0000 Read-Data Return water temperature: 0.00 18:50:31.276026 BC01C202B Read-Ack Return water temperature: 32.17 18:50:32.174839 T80190000 Read-Data Boiler water temperature: 0.00 18:50:32.276099 B40192166 Read-Ack Boiler water temperature: 33.40 18:50:33.174292 T10013000 Write-Data Control setpoint: 48.00 18:50:33.319855 BD0013000 Write-Ack Control setpoint: 48.00 18:50:34.172919 T00000300 Read-Data Status: 00000011 00000000 18:50:34.276574 B40000302 Read-Ack Status: 00000011 00000010 18:50:35.172606 T00110000 Read-Data Relative modulation level: 0.00 18:50:35.276359 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:36.189840 T000A0000 Read-Data Number of TSPs: 0 18:50:36.210439 R00780000 Read-Data Burner operation hours: 0 18:50:36.299177 BC07805C3 Read-Ack Burner operation hours: 1475 18:50:36.309141 AF00A0000 Unk-DataId Number of TSPs: 0 18:50:37.171460 T80190000 Read-Data Boiler water temperature: 0.00 18:50:37.277527 BC019214C Read-Ack Boiler water temperature: 33.30 18:50:38.170626 T10013000 Write-Data Control setpoint: 48.00 18:50:38.300183 BD0013000 Write-Ack Control setpoint: 48.00 18:50:39.169996 T00000300 Read-Data Status: 00000011 00000000 18:50:39.276454 B40000302 Read-Ack Status: 00000011 00000010 18:50:40.170109 T00110000 Read-Data Relative modulation level: 0.00 18:50:40.279553 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:41.167662 T000C0000 Read-Data Size of fault buffer: 0 18:50:41.185711 R80790000 Read-Data CH pump operation hours: 0 18:50:41.276441 B407907CD Read-Ack CH pump operation hours: 1997 18:50:41.372535 AF00C0000 Unk-DataId Size of fault buffer: 0 18:50:42.167532 T80190000 Read-Data Boiler water temperature: 0.00 18:50:42.288288 B40192133 Read-Ack Boiler water temperature: 33.20 18:50:43.166373 T10013000 Write-Data Control setpoint: 48.00 18:50:43.302131 BD0013000 Write-Ack Control setpoint: 48.00 18:50:44.169914 T00000300 Read-Data Status: 00000011 00000000 18:50:44.276268 B40000302 Read-Ack Status: 00000011 00000010 18:50:45.166259 T00110000 Read-Data Relative modulation level: 0.00 18:50:45.276682 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:46.166040 T00050000 Read-Data Application-specific flags: 00000000 0 18:50:46.282740 BC00500FF Read-Ack Application-specific flags: 00000000 255 18:50:47.164358 T80190000 Read-Data Boiler water temperature: 0.00 18:50:47.276924 B40192133 Read-Ack Boiler water temperature: 33.20 18:50:48.164669 T10013000 Write-Data Control setpoint: 48.00 18:50:48.306527 BD0013000 Write-Ack Control setpoint: 48.00 18:50:49.162969 T00000300 Read-Data Status: 00000011 00000000 18:50:49.275963 B40000302 Read-Ack Status: 00000011 00000010 18:50:50.162764 T00110000 Read-Data Relative modulation level: 0.00 18:50:50.276697 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:51.161959 T00090000 Read-Data Remote override room setpoint: 0.00 18:50:51.177665 R807A0000 Read-Data DHW pump/valve operation hours: 0 18:50:51.275712 B407A21E4 Read-Ack DHW pump/valve operation hours: 8676 18:50:51.289116 AC0090000 Read-Ack Remote override room setpoint: 0.00 18:50:52.161283 T80190000 Read-Data Boiler water temperature: 0.00 18:50:52.276606 B40192133 Read-Ack Boiler water temperature: 33.20 18:50:53.161210 T10013000 Write-Data Control setpoint: 48.00 18:50:53.322352 BD0013000 Write-Ack Control setpoint: 48.00 18:50:54.161033 T00000300 Read-Data Status: 00000011 00000000 18:50:54.277087 B40000302 Read-Ack Status: 00000011 00000010 18:50:55.159551 T00110000 Read-Data Relative modulation level: 0.00 18:50:55.276666 BC0110000 Read-Ack Relative modulation level: 0.00 18:50:56.162877 T900E6400 Write-Data Maximum relative modulation level: 100.00 18:50:56.314381 B500E6400 Write-Ack Maximum relative modulation level: 100.00 18:50:57.168794 T80190000 Read-Data Boiler water temperature: 0.00 18:50:57.280191 BC0192119 Read-Ack Boiler water temperature: 33.10 18:50:58.162535 T10013000 Write-Data Control setpoint: 48.00 18:50:58.301193 BD0013000 Write-Ack Control setpoint: 48.00 18:50:59.157008 T00000300 Read-Data Status: 00000011 00000000 18:50:59.276820 B40000302 Read-Ack Status: 00000011 00000010 18:51:00.154214 T00110000 Read-Data Relative modulation level: 0.00 18:51:00.276594 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:01.154887 T10101400 Write-Data Room setpoint: 20.00 18:51:01.316804 BD0101400 Write-Ack Room setpoint: 20.00 18:51:02.154791 T80190000 Read-Data Boiler water temperature: 0.00 18:51:02.276463 BC0192119 Read-Ack Boiler water temperature: 33.10 18:51:03.152961 T10013000 Write-Data Control setpoint: 48.00 18:51:03.291602 BD0013000 Write-Ack Control setpoint: 48.00 18:51:04.151697 T00000300 Read-Data Status: 00000011 00000000 18:51:04.276566 B40000302 Read-Ack Status: 00000011 00000010 18:51:05.151806 T00110000 Read-Data Relative modulation level: 0.00 18:51:05.276648 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:06.152117 T90181400 Write-Data Room temperature: 20.00 18:51:06.302600 B50181400 Write-Ack Room temperature: 20.00 18:51:07.158881 T80190000 Read-Data Boiler water temperature: 0.00 18:51:07.276589 B40192100 Read-Ack Boiler water temperature: 33.00 18:51:08.149624 T10013000 Write-Data Control setpoint: 48.00 18:51:08.280350 BD0013000 Write-Ack Control setpoint: 48.00 18:51:09.149017 T00000300 Read-Data Status: 00000011 00000000 18:51:09.276609 B40000302 Read-Ack Status: 00000011 00000010 18:51:10.148041 T00110000 Read-Data Relative modulation level: 0.00 18:51:10.276186 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:11.145958 T80310000 Read-Data Max CH setpoint boundaries: 0 0 18:51:11.275997 BC0314600 Read-Ack Max CH setpoint boundaries: 70 0 18:51:12.146170 T80190000 Read-Data Boiler water temperature: 0.00 18:51:12.276456 B40192100 Read-Ack Boiler water temperature: 33.00 18:51:13.146897 T10013000 Write-Data Control setpoint: 48.00 18:51:13.277228 BD0013000 Write-Ack Control setpoint: 48.00 18:51:14.145107 T00000300 Read-Data Status: 00000011 00000000 18:51:14.276364 B40000302 Read-Ack Status: 00000011 00000010 18:51:15.144497 T00110000 Read-Data Relative modulation level: 0.00 18:51:15.276545 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:16.143712 T1002010D Write-Data Master configuration: 00000001 13 18:51:16.306988 BD002010D Write-Ack Master configuration: 00000001 13 18:51:17.142793 T80190000 Read-Data Boiler water temperature: 0.00 18:51:17.276439 B40192100 Read-Ack Boiler water temperature: 33.00 18:51:18.142318 T10013000 Write-Data Control setpoint: 48.00 18:51:18.277440 BD0013000 Write-Ack Control setpoint: 48.00 18:51:19.143759 T00000300 Read-Data Status: 00000011 00000000 18:51:19.276839 B40000302 Read-Ack Status: 00000011 00000010 18:51:20.140019 T00110000 Read-Data Relative modulation level: 0.00 18:51:20.289493 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:21.139349 T00030000 Read-Data Slave configuration: 00000000 0 18:51:21.276088 B4003410B Read-Ack Slave configuration: 01000001 11 18:51:22.137992 T80190000 Read-Data Boiler water temperature: 0.00 18:51:22.275564 B40192100 Read-Ack Boiler water temperature: 33.00 18:51:23.137067 T10013000 Write-Data Control setpoint: 48.00 18:51:23.277138 BD0013000 Write-Ack Control setpoint: 48.00 18:51:24.137009 T00000300 Read-Data Status: 00000011 00000000 18:51:24.288359 B40000302 Read-Ack Status: 00000011 00000010 18:51:25.137346 T00110000 Read-Data Relative modulation level: 0.00 18:51:25.275844 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:26.135441 T00390000 Read-Data Max CH water setpoint: 0.00 18:51:26.275997 B40394600 Read-Ack Max CH water setpoint: 70.00 18:51:27.144539 T80190000 Read-Data Boiler water temperature: 0.00 18:51:27.277748 B401920E6 Read-Ack Boiler water temperature: 32.90 18:51:28.131511 T10013000 Write-Data Control setpoint: 48.00 18:51:28.280218 BD0013000 Write-Ack Control setpoint: 48.00 18:51:28.507407 SC: 18:51/3 18:51:29.132042 T00000300 Read-Data Status: 00000011 00000000 18:51:29.276626 B40000302 Read-Ack Status: 00000011 00000010 18:51:30.130279 T00110000 Read-Data Relative modulation level: 0.00 18:51:30.276773 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:31.130884 T001B0000 Read-Data Outside temperature: 0.00 18:51:31.276393 B601B0000 Data-Inv Outside temperature: 0.00 18:51:32.128895 T80190000 Read-Data Boiler water temperature: 0.00 18:51:32.276502 B401920E6 Read-Ack Boiler water temperature: 32.90 18:51:33.127296 T10013000 Write-Data Control setpoint: 48.00 18:51:33.277798 BD0013000 Write-Ack Control setpoint: 48.00 18:51:34.127023 T00000300 Read-Data Status: 00000011 00000000 18:51:34.275988 B40000302 Read-Ack Status: 00000011 00000010 18:51:35.126125 T00110000 Read-Data Relative modulation level: 0.00 18:51:35.275495 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:36.125978 T00060000 Read-Data Remote parameter flags: 00000000 00000000 18:51:36.276330 BC0060303 Read-Ack Remote parameter flags: 00000011 00000011 18:51:37.123984 T80190000 Read-Data Boiler water temperature: 0.00 18:51:37.276659 BC01920CC Read-Ack Boiler water temperature: 32.80 18:51:38.124197 T10013000 Write-Data Control setpoint: 48.00 18:51:38.277212 BD0013000 Write-Ack Control setpoint: 48.00 18:51:39.123193 T00000300 Read-Data Status: 00000011 00000000 18:51:39.276262 B40000302 Read-Ack Status: 00000011 00000010 18:51:40.122793 T00110000 Read-Data Relative modulation level: 0.00 18:51:40.276340 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:41.120762 T907E010B Write-Data Master product version: 1 11 18:51:41.136922 R007B0000 Read-Data DHW burner operation hours: 0 18:51:41.277820 BC07B0053 Read-Ack DHW burner operation hours: 83 18:51:41.289490 AF07E010B Unk-DataId Master product version: 1 11 18:51:42.119388 T80190000 Read-Data Boiler water temperature: 0.00 18:51:42.275820 BC01920CC Read-Ack Boiler water temperature: 32.80 18:51:43.119833 T10013000 Write-Data Control setpoint: 48.00 18:51:43.281197 BD0013000 Write-Ack Control setpoint: 48.00 18:51:44.118973 T00000300 Read-Data Status: 00000011 00000000 18:51:44.278183 B40000302 Read-Ack Status: 00000011 00000010 18:51:45.118137 T00110000 Read-Data Relative modulation level: 0.00 18:51:45.276124 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:46.119792 T807F0000 Read-Data Slave product version: 0 0 18:51:46.275958 BC07F1401 Read-Ack Slave product version: 20 1 18:51:47.117149 T80190000 Read-Data Boiler water temperature: 0.00 18:51:47.277931 BC01920CC Read-Ack Boiler water temperature: 32.80 18:51:48.115447 T10013000 Write-Data Control setpoint: 48.00 18:51:48.279392 BD0013000 Write-Ack Control setpoint: 48.00 18:51:49.116028 T00000300 Read-Data Status: 00000011 00000000 18:51:49.276576 B40000302 Read-Ack Status: 00000011 00000010 18:51:50.116611 T00110000 Read-Data Relative modulation level: 0.00 18:51:50.276931 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:51.113362 T80380000 Read-Data DHW setpoint: 0.00 18:51:51.279308 B40383C00 Read-Ack DHW setpoint: 60.00 18:51:52.112603 T80190000 Read-Data Boiler water temperature: 0.00 18:51:52.275807 BC01920CC Read-Ack Boiler water temperature: 32.80 18:51:53.112305 T10013000 Write-Data Control setpoint: 48.00 18:51:53.276253 BD0013000 Write-Ack Control setpoint: 48.00 18:51:54.128562 T00000300 Read-Data Status: 00000011 00000000 18:51:54.280586 B40000302 Read-Ack Status: 00000011 00000010 18:51:55.110454 T00110000 Read-Data Relative modulation level: 0.00 18:51:55.276406 BC0110000 Read-Ack Relative modulation level: 0.00 18:51:56.142327 T00300000 Read-Data DHW setpoint boundaries: 0 0 18:51:56.276054 BC0304128 Read-Ack DHW setpoint boundaries: 65 40 18:51:57.110473 T80190000 Read-Data Boiler water temperature: 0.00 18:51:57.276321 BC01920CC Read-Ack Boiler water temperature: 32.80 18:51:58.108682 T10013000 Write-Data Control setpoint: 48.00 18:51:58.276900 BD0013000 Write-Ack Control setpoint: 48.00 18:51:59.107897 T00000300 Read-Data Status: 00000011 00000000 18:51:59.200510 B40000302 Read-Ack Status: 00000011 00000010 18:52:00.108155 T00110000 Read-Data Relative modulation level: 0.00 18:52:00.200059 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:01.107642 T00120000 Read-Data CH water pressure: 0.00 18:52:01.198826 B40120200 Read-Ack CH water pressure: 2.00 18:52:02.105350 T80190000 Read-Data Boiler water temperature: 0.00 18:52:02.201669 BC01920CC Read-Ack Boiler water temperature: 32.80 18:52:03.104984 T10013000 Write-Data Control setpoint: 48.00 18:52:03.259349 BD0013000 Write-Ack Control setpoint: 48.00 18:52:04.105815 T00000300 Read-Data Status: 00000011 00000000 18:52:04.195729 B40000302 Read-Ack Status: 00000011 00000010 18:52:05.104129 T00110000 Read-Data Relative modulation level: 0.00 18:52:05.196210 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:06.103541 T80130000 Read-Data DHW flow rate: 0.00 18:52:06.124025 R00740000 Read-Data Burner starts: 0 18:52:06.196017 BC0742712 Read-Ack Burner starts: 10002 18:52:06.310007 A70130000 Unk-DataId DHW flow rate: 0.00 18:52:07.103539 T80190000 Read-Data Boiler water temperature: 0.00 18:52:07.194636 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:08.105268 T10013000 Write-Data Control setpoint: 48.00 18:52:08.252415 BD0013000 Write-Ack Control setpoint: 48.00 18:52:09.101219 T00000300 Read-Data Status: 00000011 00000000 18:52:09.193081 B40000302 Read-Ack Status: 00000011 00000010 18:52:10.100532 T00110000 Read-Data Relative modulation level: 0.00 18:52:10.192447 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:11.100419 T801A0000 Read-Data DHW temperature: 0.00 18:52:11.195976 BE01A0000 Data-Inv DHW temperature: 0.00 18:52:12.098919 T80190000 Read-Data Boiler water temperature: 0.00 18:52:12.191371 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:13.097870 T10013000 Write-Data Control setpoint: 48.00 18:52:13.276337 BD0013000 Write-Ack Control setpoint: 48.00 18:52:14.098198 T00000300 Read-Data Status: 00000011 00000000 18:52:14.188566 B40000302 Read-Ack Status: 00000011 00000010 18:52:15.096217 T00110000 Read-Data Relative modulation level: 0.00 18:52:15.188679 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:16.096455 T801C0000 Read-Data Return water temperature: 0.00 18:52:16.187774 B401C201C Read-Ack Return water temperature: 32.11 18:52:17.096619 T80190000 Read-Data Boiler water temperature: 0.00 18:52:17.187191 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:18.093861 T10013000 Write-Data Control setpoint: 48.00 18:52:18.252439 BD0013000 Write-Ack Control setpoint: 48.00 18:52:19.093433 T00000300 Read-Data Status: 00000011 00000000 18:52:19.185543 B40000302 Read-Ack Status: 00000011 00000010 18:52:20.111847 T00110000 Read-Data Relative modulation level: 0.00 18:52:20.184316 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:21.091834 T000A0000 Read-Data Number of TSPs: 0 18:52:21.110900 R80750000 Read-Data CH pump starts: 0 18:52:21.184149 B407520D5 Read-Ack CH pump starts: 8405 18:52:21.194895 AF00A0000 Unk-DataId Number of TSPs: 0 18:52:22.089304 T80190000 Read-Data Boiler water temperature: 0.00 18:52:22.181998 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:23.090527 T10013000 Write-Data Control setpoint: 48.00 18:52:23.244187 BD0013000 Write-Ack Control setpoint: 48.00 18:52:24.104141 T00000300 Read-Data Status: 00000011 00000000 18:52:24.181356 B40000302 Read-Ack Status: 00000011 00000010 18:52:25.086969 T00110000 Read-Data Relative modulation level: 0.00 18:52:25.184377 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:26.088985 T000C0000 Read-Data Size of fault buffer: 0 18:52:26.110228 R80760000 Read-Data DHW pump/valve starts: 0 18:52:26.180554 B4076172E Read-Ack DHW pump/valve starts: 5934 18:52:26.277093 AF00C0000 Unk-DataId Size of fault buffer: 0 18:52:27.086885 T80190000 Read-Data Boiler water temperature: 0.00 18:52:27.179054 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:28.086421 T10013000 Write-Data Control setpoint: 48.00 18:52:28.223799 BD0013000 Write-Ack Control setpoint: 48.00 18:52:28.516746 SC: 18:52/3 18:52:29.102337 T00000300 Read-Data Status: 00000011 00000000 18:52:29.176338 B40000302 Read-Ack Status: 00000011 00000010 18:52:30.083905 T00110000 Read-Data Relative modulation level: 0.00 18:52:30.177048 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:31.083315 T00050000 Read-Data Application-specific flags: 00000000 0 18:52:31.177814 BC00500FF Read-Ack Application-specific flags: 00000000 255 18:52:32.084602 T80190000 Read-Data Boiler water temperature: 0.00 18:52:32.192509 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:33.084138 T10013000 Write-Data Control setpoint: 48.00 18:52:33.243409 BD0013000 Write-Ack Control setpoint: 48.00 18:52:34.081406 T00000300 Read-Data Status: 00000011 00000000 18:52:34.175776 B40000302 Read-Ack Status: 00000011 00000010 18:52:35.080824 T00110000 Read-Data Relative modulation level: 0.00 18:52:35.176514 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:36.081490 T00090000 Read-Data Remote override room setpoint: 0.00 18:52:36.103703 R00770000 Read-Data DHW burner starts: 0 18:52:36.197603 B407703BC Read-Ack DHW burner starts: 956 18:52:36.209761 AC0090000 Read-Ack Remote override room setpoint: 0.00 18:52:37.083366 T80190000 Read-Data Boiler water temperature: 0.00 18:52:37.176313 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:38.079304 T10013000 Write-Data Control setpoint: 48.00 18:52:38.199781 BD0013000 Write-Ack Control setpoint: 48.00 18:52:39.077305 T00000300 Read-Data Status: 00000011 00000000 18:52:39.174889 B40000302 Read-Ack Status: 00000011 00000010 18:52:40.077701 T00110000 Read-Data Relative modulation level: 0.00 18:52:40.176505 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:41.077956 T900E6400 Write-Data Maximum relative modulation level: 100.00 18:52:41.227004 B500E6400 Write-Ack Maximum relative modulation level: 100.00 18:52:42.076556 T80190000 Read-Data Boiler water temperature: 0.00 18:52:42.178080 B401920B3 Read-Ack Boiler water temperature: 32.70 18:52:43.076337 T10013000 Write-Data Control setpoint: 48.00 18:52:43.204892 BD0013000 Write-Ack Control setpoint: 48.00 18:52:44.074389 T00000300 Read-Data Status: 00000011 00000000 18:52:44.176162 B40000302 Read-Ack Status: 00000011 00000010 18:52:45.074154 T00110000 Read-Data Relative modulation level: 0.00 18:52:45.176620 BC0110000 Read-Ack Relative modulation level: 0.00 18:52:46.072686 T10101400 Write-Data Room setpoint: 20.00 18:52:46.225915 BD0101400 Write-Ack Room setpoint: 20.00 18:52:47.071577 T80190000 Read-Data Boiler water temperature: 0.00 18:52:47.177959 BC0192099 Read-Ack Boiler water temperature: 32.60 18:52:48.071988 T10013000 Write-Data Control setpoint: 48.00 18:52:48.207658 BD0013000 Write-Ack Control setpoint: 48.00 18:52:49.070677 T00000300 Read-Data Status: 00000011 00000000 18:52:49.175614 BC000030A Read-Ack Status: 00000011 00001010 18:52:50.069830 T00000300 Read-Data Status: 00000011 00000000 18:52:50.176000 BC000030A Read-Ack Status: 00000011 00001010 18:52:51.074133 T00110000 Read-Data Relative modulation level: 0.00 18:52:51.175826 B40117C00 Read-Ack Relative modulation level: 124.00 18:52:52.067523 T00000300 Read-Data Status: 00000011 00000000 18:52:52.175807 BC000030A Read-Ack Status: 00000011 00001010 18:52:53.067330 T90181400 Write-Data Room temperature: 20.00 18:52:53.224890 B50181400 Write-Ack Room temperature: 20.00 18:52:54.067076 T80190000 Read-Data Boiler water temperature: 0.00 18:52:54.177510 B40192166 Read-Ack Boiler water temperature: 33.40 18:52:55.065887 T10013000 Write-Data Control setpoint: 48.00 18:52:55.200727 BD0013000 Write-Ack Control setpoint: 48.00 18:52:56.066924 T00000300 Read-Data Status: 00000011 00000000 18:52:56.231761 BC000030A Read-Ack Status: 00000011 00001010 18:52:57.063794 T00110000 Read-Data Relative modulation level: 0.00 18:52:57.176817 BC0111B00 Read-Ack Relative modulation level: 27.00 18:52:58.069059 T80310000 Read-Data Max CH setpoint boundaries: 0 0 18:52:58.175982 BC0314600 Read-Ack Max CH setpoint boundaries: 70 0 18:52:59.063885 T80190000 Read-Data Boiler water temperature: 0.00 18:52:59.175976 BC0192533 Read-Ack Boiler water temperature: 37.20 18:53:00.061878 T10013000 Write-Data Control setpoint: 48.00 18:53:00.201002 BD0013000 Write-Ack Control setpoint: 48.00 18:53:01.061270 T00000300 Read-Data Status: 00000011 00000000 18:53:01.178320 BC000030A Read-Ack Status: 00000011 00001010 18:53:02.060810 T00110000 Read-Data Relative modulation level: 0.00 18:53:02.175872 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:03.059760 T1002010D Write-Data Master configuration: 00000001 13 18:53:03.204582 BD002010D Write-Ack Master configuration: 00000001 13 18:53:04.058740 T80190000 Read-Data Boiler water temperature: 0.00 18:53:04.175424 BC0192A99 Read-Ack Boiler water temperature: 42.60 18:53:05.057779 T10013000 Write-Data Control setpoint: 48.00 18:53:05.196016 BD0013000 Write-Ack Control setpoint: 48.00 18:53:06.057665 T00000300 Read-Data Status: 00000011 00000000 18:53:06.175586 BC000030A Read-Ack Status: 00000011 00001010 18:53:07.056921 T00110000 Read-Data Relative modulation level: 0.00 18:53:07.176094 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:08.055709 T00030000 Read-Data Slave configuration: 00000000 0 18:53:08.176248 B4003410B Read-Ack Slave configuration: 01000001 11 18:53:09.055845 T80190000 Read-Data Boiler water temperature: 0.00 18:53:09.175228 B40193066 Read-Ack Boiler water temperature: 48.40 18:53:10.054933 T10013000 Write-Data Control setpoint: 48.00 18:53:10.185957 BD0013000 Write-Ack Control setpoint: 48.00 18:53:11.053499 T00000300 Read-Data Status: 00000011 00000000 18:53:11.175876 BC000030A Read-Ack Status: 00000011 00001010 18:53:12.053122 T00110000 Read-Data Relative modulation level: 0.00 18:53:12.175897 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:13.059359 T00390000 Read-Data Max CH water setpoint: 0.00 18:53:13.176715 B40394600 Read-Ack Max CH water setpoint: 70.00 18:53:14.050316 T80190000 Read-Data Boiler water temperature: 0.00 18:53:14.186966 B40193500 Read-Ack Boiler water temperature: 53.00 18:53:15.049436 T10013000 Write-Data Control setpoint: 48.00 18:53:15.186983 BD0013000 Write-Ack Control setpoint: 48.00 18:53:16.050152 T00000300 Read-Data Status: 00000011 00000000 18:53:16.175422 BC000030A Read-Ack Status: 00000011 00001010 18:53:17.051158 T00110000 Read-Data Relative modulation level: 0.00 18:53:17.176443 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:18.046873 T001B0000 Read-Data Outside temperature: 0.00 18:53:18.196166 B601B0000 Data-Inv Outside temperature: 0.00 18:53:19.046304 T80190000 Read-Data Boiler water temperature: 0.00 18:53:19.175145 B40193819 Read-Ack Boiler water temperature: 56.10 18:53:20.046731 T10013000 Write-Data Control setpoint: 48.00 18:53:20.191557 BD0013000 Write-Ack Control setpoint: 48.00 18:53:21.061460 T00000300 Read-Data Status: 00000011 00000000 18:53:21.175280 BC000030A Read-Ack Status: 00000011 00001010 18:53:22.043935 T00110000 Read-Data Relative modulation level: 0.00 18:53:22.177435 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:23.079558 T00060000 Read-Data Remote parameter flags: 00000000 00000000 18:53:23.175618 BC0060303 Read-Ack Remote parameter flags: 00000011 00000011 18:53:24.043811 T80190000 Read-Data Boiler water temperature: 0.00 18:53:24.176001 B401939CC Read-Ack Boiler water temperature: 57.80 18:53:25.041962 T10013000 Write-Data Control setpoint: 48.00 18:53:25.176641 BD0013000 Write-Ack Control setpoint: 48.00 18:53:26.040914 T00000300 Read-Data Status: 00000011 00000000 18:53:26.176491 BC000030A Read-Ack Status: 00000011 00001010 18:53:27.041100 T00110000 Read-Data Relative modulation level: 0.00 18:53:27.177704 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:28.040493 T907E010B Write-Data Master product version: 1 11 18:53:28.056987 R00780000 Read-Data Burner operation hours: 0 18:53:28.207717 BC07805C3 Read-Ack Burner operation hours: 1475 18:53:28.224883 AF07E010B Unk-DataId Master product version: 1 11 18:53:28.528349 SC: 18:53/3 18:53:29.039323 T80190000 Read-Data Boiler water temperature: 0.00 18:53:29.175682 BC0193AB3 Read-Ack Boiler water temperature: 58.70 18:53:30.038771 T10013000 Write-Data Control setpoint: 48.00 18:53:30.184951 BD0013000 Write-Ack Control setpoint: 48.00 18:53:31.038075 T00000300 Read-Data Status: 00000011 00000000 18:53:31.175429 BC000030A Read-Ack Status: 00000011 00001010 18:53:32.036731 T00110000 Read-Data Relative modulation level: 0.00 18:53:32.175263 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:33.035646 T807F0000 Read-Data Slave product version: 0 0 18:53:33.175322 BC07F1401 Read-Ack Slave product version: 20 1 18:53:34.034763 T80190000 Read-Data Boiler water temperature: 0.00 18:53:34.178751 B40193B19 Read-Ack Boiler water temperature: 59.10 18:53:35.035581 T10013000 Write-Data Control setpoint: 48.00 18:53:35.181762 BD0013000 Write-Ack Control setpoint: 48.00 18:53:36.033306 T00000300 Read-Data Status: 00000011 00000000 18:53:36.174249 BC000030A Read-Ack Status: 00000011 00001010 18:53:37.032192 T00110000 Read-Data Relative modulation level: 0.00 18:53:37.175527 B40110200 Read-Ack Relative modulation level: 2.00 18:53:38.031638 T80380000 Read-Data DHW setpoint: 0.00 18:53:38.175217 B40383C00 Read-Ack DHW setpoint: 60.00 18:53:39.031261 T80190000 Read-Data Boiler water temperature: 0.00 18:53:39.175604 BC0193B66 Read-Ack Boiler water temperature: 59.40 18:53:40.030460 T10013000 Write-Data Control setpoint: 48.00 18:53:40.175662 BD0013000 Write-Ack Control setpoint: 48.00 18:53:41.028883 T00000300 Read-Data Status: 00000011 00000000 18:53:41.176905 BC000030A Read-Ack Status: 00000011 00001010 18:53:42.029182 T00110000 Read-Data Relative modulation level: 0.00 18:53:42.175443 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:43.028464 T00300000 Read-Data DHW setpoint boundaries: 0 0 18:53:43.175137 BC0304128 Read-Ack DHW setpoint boundaries: 65 40 18:53:44.031585 T80190000 Read-Data Boiler water temperature: 0.00 18:53:44.175547 B40193B80 Read-Ack Boiler water temperature: 59.50 18:53:45.027253 T10013000 Write-Data Control setpoint: 48.00 18:53:45.175886 BD0013000 Write-Ack Control setpoint: 48.00 18:53:46.029541 T00000300 Read-Data Status: 00000011 00000000 18:53:46.176275 BC000030A Read-Ack Status: 00000011 00001010 18:53:47.025820 T00110000 Read-Data Relative modulation level: 0.00 18:53:47.175832 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:48.035402 T00120000 Read-Data CH water pressure: 0.00 18:53:48.181340 B40120200 Read-Ack CH water pressure: 2.00 18:53:49.023915 T80190000 Read-Data Boiler water temperature: 0.00 18:53:49.175821 B40193B80 Read-Ack Boiler water temperature: 59.50 18:53:50.026235 T10013000 Write-Data Control setpoint: 48.00 18:53:50.211440 BD0013000 Write-Ack Control setpoint: 48.00 18:53:51.022809 T00000300 Read-Data Status: 00000011 00000000 18:53:51.175640 BC000030A Read-Ack Status: 00000011 00001010 18:53:52.034221 T00110000 Read-Data Relative modulation level: 0.00 18:53:52.177365 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:53.020616 T80130000 Read-Data DHW flow rate: 0.00 18:53:53.036863 R80790000 Read-Data CH pump operation hours: 0 18:53:53.181067 B407907CD Read-Ack CH pump operation hours: 1997 18:53:53.200590 A70130000 Unk-DataId DHW flow rate: 0.00 18:53:54.019719 T80190000 Read-Data Boiler water temperature: 0.00 18:53:54.176006 B40193B80 Read-Ack Boiler water temperature: 59.50 18:53:55.019841 T10013000 Write-Data Control setpoint: 48.00 18:53:55.174819 BD0013000 Write-Ack Control setpoint: 48.00 18:53:56.021134 T00000300 Read-Data Status: 00000011 00000000 18:53:56.215098 BC000030A Read-Ack Status: 00000011 00001010 18:53:57.017974 T00110000 Read-Data Relative modulation level: 0.00 18:53:57.176042 BC0110000 Read-Ack Relative modulation level: 0.00 18:53:58.017256 T801A0000 Read-Data DHW temperature: 0.00 18:53:58.175981 BE01A0000 Data-Inv DHW temperature: 0.00 18:53:59.017026 T80190000 Read-Data Boiler water temperature: 0.00 18:53:59.176603 B40193B80 Read-Ack Boiler water temperature: 59.50 18:54:00.020229 T10013000 Write-Data Control setpoint: 48.00 18:54:00.194027 BD0013000 Write-Ack Control setpoint: 48.00 18:54:01.015475 T00000300 Read-Data Status: 00000011 00000000 18:54:01.176348 BC000030A Read-Ack Status: 00000011 00001010 18:54:02.014139 T00110000 Read-Data Relative modulation level: 0.00 18:54:02.176001 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:03.013950 T801C0000 Read-Data Return water temperature: 0.00 18:54:03.175801 BC01C2102 Read-Ack Return water temperature: 33.01 18:54:04.013656 T80190000 Read-Data Boiler water temperature: 0.00 18:54:04.194301 BC0193B99 Read-Ack Boiler water temperature: 59.60 18:54:05.020921 T10013000 Write-Data Control setpoint: 48.00 18:54:05.178095 BD0013000 Write-Ack Control setpoint: 48.00 18:54:06.010949 T00000300 Read-Data Status: 00000011 00000000 18:54:06.175945 BC000030A Read-Ack Status: 00000011 00001010 18:54:07.010588 T00110000 Read-Data Relative modulation level: 0.00 18:54:07.175627 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:08.009781 T000A0000 Read-Data Number of TSPs: 0 18:54:08.028340 R807A0000 Read-Data DHW pump/valve operation hours: 0 18:54:08.175232 B407A21E4 Read-Ack DHW pump/valve operation hours: 8676 18:54:08.289698 AF00A0000 Unk-DataId Number of TSPs: 0 18:54:09.008556 T80190000 Read-Data Boiler water temperature: 0.00 18:54:09.176006 BC0193BCC Read-Ack Boiler water temperature: 59.80 18:54:10.011212 T10013000 Write-Data Control setpoint: 48.00 18:54:10.156859 BD0013000 Write-Ack Control setpoint: 48.00 18:54:11.006932 T00000300 Read-Data Status: 00000011 00000000 18:54:11.099621 BC000030A Read-Ack Status: 00000011 00001010 18:54:12.006601 T00110000 Read-Data Relative modulation level: 0.00 18:54:12.098428 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:13.004649 T000C0000 Read-Data Size of fault buffer: 0 18:54:13.020880 R007B0000 Read-Data DHW burner operation hours: 0 18:54:13.097785 BC07B0053 Read-Ack DHW burner operation hours: 83 18:54:13.194569 AF00C0000 Unk-DataId Size of fault buffer: 0 18:54:14.004145 T80190000 Read-Data Boiler water temperature: 0.00 18:54:14.097411 B40193BE6 Read-Ack Boiler water temperature: 59.90 18:54:15.022528 T10013000 Write-Data Control setpoint: 48.00 18:54:15.160244 BD0013000 Write-Ack Control setpoint: 48.00 18:54:16.004087 T00000300 Read-Data Status: 00000011 00000000 18:54:16.096990 BC000030A Read-Ack Status: 00000011 00001010 18:54:17.002644 T00110000 Read-Data Relative modulation level: 0.00 18:54:17.095864 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:18.003137 T00050000 Read-Data Application-specific flags: 00000000 0 18:54:18.093910 BC00500FF Read-Ack Application-specific flags: 00000000 255 18:54:19.003907 T80190000 Read-Data Boiler water temperature: 0.00 18:54:19.098042 BC0193C19 Read-Ack Boiler water temperature: 60.10 18:54:20.023368 T10013000 Write-Data Control setpoint: 48.00 18:54:20.161651 BD0013000 Write-Ack Control setpoint: 48.00 18:54:21.000027 T00000300 Read-Data Status: 00000011 00000000 18:54:21.093256 BC000030A Read-Ack Status: 00000011 00001010 18:54:22.016053 T00110000 Read-Data Relative modulation level: 0.00 18:54:22.090965 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:22.998340 T00090000 Read-Data Remote override room setpoint: 0.00 18:54:23.015292 R00740000 Read-Data Burner starts: 0 18:54:23.092147 B40742713 Read-Ack Burner starts: 10003 18:54:23.190623 AC0090000 Read-Ack Remote override room setpoint: 0.00 18:54:23.998048 T80190000 Read-Data Boiler water temperature: 0.00 18:54:24.090321 B40193C33 Read-Ack Boiler water temperature: 60.20 18:54:24.997284 T10013000 Write-Data Control setpoint: 48.00 18:54:25.162996 BD0013000 Write-Ack Control setpoint: 48.00 18:54:25.996036 T00000300 Read-Data Status: 00000011 00000000 18:54:26.105862 BC000030A Read-Ack Status: 00000011 00001010 18:54:26.995280 T00110000 Read-Data Relative modulation level: 0.00 18:54:27.087809 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:27.994619 T900E6400 Write-Data Maximum relative modulation level: 100.00 18:54:28.123795 B500E6400 Write-Ack Maximum relative modulation level: 100.00 18:54:28.535922 SC: 18:54/3 18:54:28.994211 T80190000 Read-Data Boiler water temperature: 0.00 18:54:29.089621 BC0193C4C Read-Ack Boiler water temperature: 60.30 18:54:29.993125 T10013000 Write-Data Control setpoint: 48.00 18:54:30.140286 BD0013000 Write-Ack Control setpoint: 48.00 18:54:30.991813 T00000300 Read-Data Status: 00000011 00000000 18:54:31.088086 BC000030A Read-Ack Status: 00000011 00001010 18:54:31.995749 T00110000 Read-Data Relative modulation level: 0.00 18:54:32.083963 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:32.991199 T10101400 Write-Data Room setpoint: 20.00 18:54:33.111064 BD0101400 Write-Ack Room setpoint: 20.00 18:54:33.988888 T80190000 Read-Data Boiler water temperature: 0.00 18:54:34.081478 BC0193C4C Read-Ack Boiler water temperature: 60.30 18:54:34.989668 T10013000 Write-Data Control setpoint: 48.00 18:54:35.149440 BD0013000 Write-Ack Control setpoint: 48.00 18:54:35.989165 T00000300 Read-Data Status: 00000011 00000000 18:54:36.085753 BC000030A Read-Ack Status: 00000011 00001010 18:54:36.989287 T00110000 Read-Data Relative modulation level: 0.00 18:54:37.080552 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:37.986618 T90181400 Write-Data Room temperature: 20.00 18:54:38.115352 B50181400 Write-Ack Room temperature: 20.00 18:54:38.985551 T80190000 Read-Data Boiler water temperature: 0.00 18:54:39.077058 B40193C66 Read-Ack Boiler water temperature: 60.40 18:54:39.984193 T10013000 Write-Data Control setpoint: 48.00 18:54:40.144845 BD0013000 Write-Ack Control setpoint: 48.00 18:54:40.983122 T00000300 Read-Data Status: 00000011 00000000 18:54:41.075726 BC000030A Read-Ack Status: 00000011 00001010 18:54:41.983251 T00110000 Read-Data Relative modulation level: 0.00 18:54:42.075764 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:42.981237 T80310000 Read-Data Max CH setpoint boundaries: 0 0 18:54:43.075406 BC0314600 Read-Ack Max CH setpoint boundaries: 70 0 18:54:43.981105 T80190000 Read-Data Boiler water temperature: 0.00 18:54:44.079513 B40193C66 Read-Ack Boiler water temperature: 60.40 18:54:44.980616 T10013000 Write-Data Control setpoint: 48.00 18:54:45.116350 BD0013000 Write-Ack Control setpoint: 48.00 18:54:45.980274 T00000300 Read-Data Status: 00000011 00000000 18:54:46.075340 BC000030A Read-Ack Status: 00000011 00001010 18:54:46.977861 T00110000 Read-Data Relative modulation level: 0.00 18:54:47.075550 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:47.977307 T1002010D Write-Data Master configuration: 00000001 13 18:54:48.131614 BD002010D Write-Ack Master configuration: 00000001 13 18:54:48.985685 T80190000 Read-Data Boiler water temperature: 0.00 18:54:49.075313 BC0193C80 Read-Ack Boiler water temperature: 60.50 18:54:49.976354 T10013000 Write-Data Control setpoint: 48.00 18:54:50.119921 BD0013000 Write-Ack Control setpoint: 48.00 18:54:50.975734 T00000300 Read-Data Status: 00000011 00000000 18:54:51.075348 BC000030A Read-Ack Status: 00000011 00001010 18:54:51.975756 T00110000 Read-Data Relative modulation level: 0.00 18:54:52.077082 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:52.976479 T00030000 Read-Data Slave configuration: 00000000 0 18:54:53.075177 B4003410B Read-Ack Slave configuration: 01000001 11 18:54:53.972908 T80190000 Read-Data Boiler water temperature: 0.00 18:54:54.076380 BC0193C80 Read-Ack Boiler water temperature: 60.50 18:54:54.972057 T10013000 Write-Data Control setpoint: 48.00 18:54:55.122857 BD0013000 Write-Ack Control setpoint: 48.00 18:54:55.971233 T00000300 Read-Data Status: 00000011 00000000 18:54:56.172028 BC000030A Read-Ack Status: 00000011 00001010 18:54:56.981336 T00110000 Read-Data Relative modulation level: 0.00 18:54:57.075279 BC0110000 Read-Ack Relative modulation level: 0.00 18:54:57.969861 T00390000 Read-Data Max CH water setpoint: 0.00 18:54:58.076265 B40394600 Read-Ack Max CH water setpoint: 70.00 18:54:58.969512 T80190000 Read-Data Boiler water temperature: 0.00 18:54:59.075170 B40193C99 Read-Ack Boiler water temperature: 60.60 18:54:59.966970 T10013000 Write-Data Control setpoint: 48.00 18:55:00.116844 BD0013000 Write-Ack Control setpoint: 48.00 18:55:00.987718 T00000300 Read-Data Status: 00000011 00000000 18:55:01.074897 BC000030A Read-Ack Status: 00000011 00001010 18:55:01.965963 T00110000 Read-Data Relative modulation level: 0.00 18:55:02.076227 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:02.965114 T001B0000 Read-Data Outside temperature: 0.00 18:55:03.075308 B601B0000 Data-Inv Outside temperature: 0.00 18:55:03.964820 T80190000 Read-Data Boiler water temperature: 0.00 18:55:04.074885 BC0193CB3 Read-Ack Boiler water temperature: 60.70 18:55:04.992649 T10013000 Write-Data Control setpoint: 48.00 18:55:05.137074 BD0013000 Write-Ack Control setpoint: 48.00 18:55:05.963844 T00000300 Read-Data Status: 00000011 00000000 18:55:06.087148 BC000030A Read-Ack Status: 00000011 00001010 18:55:06.961856 T00110000 Read-Data Relative modulation level: 0.00 18:55:07.075430 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:07.962133 T00060000 Read-Data Remote parameter flags: 00000000 00000000 18:55:08.075160 BC0060303 Read-Ack Remote parameter flags: 00000011 00000011 18:55:08.960145 T80190000 Read-Data Boiler water temperature: 0.00 18:55:09.080157 B40193CCC Read-Ack Boiler water temperature: 60.80 18:55:09.960768 T10013000 Write-Data Control setpoint: 48.00 18:55:10.114115 BD0013000 Write-Ack Control setpoint: 48.00 18:55:10.958987 T00000300 Read-Data Status: 00000011 00000000 18:55:11.074844 BC000030A Read-Ack Status: 00000011 00001010 18:55:11.958227 T00110000 Read-Data Relative modulation level: 0.00 18:55:12.074372 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:12.956975 T907E010B Write-Data Master product version: 1 11 18:55:12.977153 R80750000 Read-Data CH pump starts: 0 18:55:13.139030 B407520D5 Read-Ack CH pump starts: 8405 18:55:13.159715 AF07E010B Unk-DataId Master product version: 1 11 18:55:13.954764 T80190000 Read-Data Boiler water temperature: 0.00 18:55:14.075483 BC0193D00 Read-Ack Boiler water temperature: 61.00 18:55:14.955278 T10013000 Write-Data Control setpoint: 48.00 18:55:15.084256 BD0013000 Write-Ack Control setpoint: 48.00 18:55:15.954433 T00000300 Read-Data Status: 00000011 00000000 18:55:16.075027 BC000030A Read-Ack Status: 00000011 00001010 18:55:16.953700 T00110000 Read-Data Relative modulation level: 0.00 18:55:17.074766 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:17.952957 T807F0000 Read-Data Slave product version: 0 0 18:55:18.075079 BC07F1401 Read-Ack Slave product version: 20 1 18:55:18.951240 T80190000 Read-Data Boiler water temperature: 0.00 18:55:19.075475 BC0193D33 Read-Ack Boiler water temperature: 61.20 18:55:19.957888 T10013000 Write-Data Control setpoint: 48.00 18:55:20.115873 BD0013000 Write-Ack Control setpoint: 48.00 18:55:20.950599 T00000300 Read-Data Status: 00000011 00000000 18:55:21.074716 BC000030A Read-Ack Status: 00000011 00001010 18:55:21.949536 T00110000 Read-Data Relative modulation level: 0.00 18:55:22.075180 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:22.964267 T80380000 Read-Data DHW setpoint: 0.00 18:55:23.080059 B40383C00 Read-Ack DHW setpoint: 60.00 18:55:23.956709 T80190000 Read-Data Boiler water temperature: 0.00 18:55:24.074979 B40193D4C Read-Ack Boiler water temperature: 61.30 18:55:24.948782 T10013000 Write-Data Control setpoint: 48.00 18:55:25.111104 BD0013000 Write-Ack Control setpoint: 48.00 18:55:25.946461 T00000300 Read-Data Status: 00000011 00000000 18:55:26.076429 BC000030A Read-Ack Status: 00000011 00001010 18:55:26.945410 T00110000 Read-Data Relative modulation level: 0.00 18:55:27.074675 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:27.944295 T00300000 Read-Data DHW setpoint boundaries: 0 0 18:55:28.075393 BC0304128 Read-Ack DHW setpoint boundaries: 65 40 18:55:28.543039 SC: 18:55/3 18:55:28.943618 T80190000 Read-Data Boiler water temperature: 0.00 18:55:29.075017 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:29.943666 T10013000 Write-Data Control setpoint: 48.00 18:55:30.083283 BD0013000 Write-Ack Control setpoint: 48.00 18:55:30.941671 T00000300 Read-Data Status: 00000011 00000000 18:55:31.074151 BC000030A Read-Ack Status: 00000011 00001010 18:55:31.942230 T00110000 Read-Data Relative modulation level: 0.00 18:55:32.074316 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:32.941063 T00120000 Read-Data CH water pressure: 0.00 18:55:33.074310 B40120200 Read-Ack CH water pressure: 2.00 18:55:33.939857 T80190000 Read-Data Boiler water temperature: 0.00 18:55:34.074423 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:34.939453 T10013000 Write-Data Control setpoint: 48.00 18:55:35.088175 BD0013000 Write-Ack Control setpoint: 48.00 18:55:35.939002 T00000300 Read-Data Status: 00000011 00000000 18:55:36.075110 BC000030A Read-Ack Status: 00000011 00001010 18:55:36.938666 T00110000 Read-Data Relative modulation level: 0.00 18:55:37.075522 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:37.937907 T80130000 Read-Data DHW flow rate: 0.00 18:55:37.955212 R80760000 Read-Data DHW pump/valve starts: 0 18:55:38.075026 B4076172E Read-Ack DHW pump/valve starts: 5934 18:55:38.092787 A70130000 Unk-DataId DHW flow rate: 0.00 18:55:38.939626 T80190000 Read-Data Boiler water temperature: 0.00 18:55:39.074968 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:39.936719 T10013000 Write-Data Control setpoint: 48.00 18:55:40.084520 BD0013000 Write-Ack Control setpoint: 48.00 18:55:40.935947 T00000300 Read-Data Status: 00000011 00000000 18:55:41.074676 BC000030A Read-Ack Status: 00000011 00001010 18:55:41.934713 T00110000 Read-Data Relative modulation level: 0.00 18:55:42.074944 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:42.935267 T801A0000 Read-Data DHW temperature: 0.00 18:55:43.074896 BE01A0000 Data-Inv DHW temperature: 0.00 18:55:43.932854 T80190000 Read-Data Boiler water temperature: 0.00 18:55:44.078757 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:44.932394 T10013000 Write-Data Control setpoint: 48.00 18:55:45.083958 BD0013000 Write-Ack Control setpoint: 48.00 18:55:45.932992 T00000300 Read-Data Status: 00000011 00000000 18:55:46.093750 BC000030A Read-Ack Status: 00000011 00001010 18:55:46.930663 T00110000 Read-Data Relative modulation level: 0.00 18:55:47.075704 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:47.930167 T801C0000 Read-Data Return water temperature: 0.00 18:55:48.074645 BC01C2119 Read-Ack Return water temperature: 33.10 18:55:48.928788 T80190000 Read-Data Boiler water temperature: 0.00 18:55:49.077135 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:49.927770 T10013000 Write-Data Control setpoint: 48.00 18:55:50.084088 BD0013000 Write-Ack Control setpoint: 48.00 18:55:50.927896 T00000300 Read-Data Status: 00000011 00000000 18:55:51.078985 BC000030A Read-Ack Status: 00000011 00001010 18:55:51.959013 T00110000 Read-Data Relative modulation level: 0.00 18:55:52.075111 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:52.927217 T000A0000 Read-Data Number of TSPs: 0 18:55:52.944213 R00770000 Read-Data DHW burner starts: 0 18:55:53.074938 B407703BC Read-Ack DHW burner starts: 956 18:55:53.089351 AF00A0000 Unk-DataId Number of TSPs: 0 18:55:53.924418 T80190000 Read-Data Boiler water temperature: 0.00 18:55:54.074773 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:54.925349 T10013000 Write-Data Control setpoint: 48.00 18:55:55.075443 BD0013000 Write-Ack Control setpoint: 48.00 18:55:55.928588 T00000300 Read-Data Status: 00000011 00000000 18:55:56.082986 BC000030A Read-Ack Status: 00000011 00001010 18:55:56.926969 T00110000 Read-Data Relative modulation level: 0.00 18:55:57.075153 BC0110000 Read-Ack Relative modulation level: 0.00 18:55:57.922907 T000C0000 Read-Data Size of fault buffer: 0 18:55:57.939778 R00780000 Read-Data Burner operation hours: 0 18:55:58.075071 BC07805C3 Read-Ack Burner operation hours: 1475 18:55:58.173381 AF00C0000 Unk-DataId Size of fault buffer: 0 18:55:58.928626 T80190000 Read-Data Boiler water temperature: 0.00 18:55:59.075116 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:55:59.922259 T10013000 Write-Data Control setpoint: 48.00 18:56:00.086649 BD0013000 Write-Ack Control setpoint: 48.00 18:56:00.922500 T00000300 Read-Data Status: 00000011 00000000 18:56:01.075032 BC000030A Read-Ack Status: 00000011 00001010 18:56:01.919893 T00110000 Read-Data Relative modulation level: 0.00 18:56:02.075609 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:02.919734 T00050000 Read-Data Application-specific flags: 00000000 0 18:56:03.075522 BC00500FF Read-Ack Application-specific flags: 00000000 255 18:56:03.920652 T80190000 Read-Data Boiler water temperature: 0.00 18:56:04.075035 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:04.920012 T10013000 Write-Data Control setpoint: 48.00 18:56:05.079225 BD0013000 Write-Ack Control setpoint: 48.00 18:56:05.918338 T00000300 Read-Data Status: 00000011 00000000 18:56:06.075841 BC000030A Read-Ack Status: 00000011 00001010 18:56:06.916388 T00110000 Read-Data Relative modulation level: 0.00 18:56:07.088021 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:07.917005 T00090000 Read-Data Remote override room setpoint: 0.00 18:56:07.937853 R80790000 Read-Data CH pump operation hours: 0 18:56:08.077748 B407907CD Read-Ack CH pump operation hours: 1997 18:56:08.089287 AC0090000 Read-Ack Remote override room setpoint: 0.00 18:56:08.914667 T80190000 Read-Data Boiler water temperature: 0.00 18:56:09.075056 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:09.913818 T10013000 Write-Data Control setpoint: 48.00 18:56:10.075370 BD0013000 Write-Ack Control setpoint: 48.00 18:56:10.913171 T00000300 Read-Data Status: 00000011 00000000 18:56:11.075109 BC000030A Read-Ack Status: 00000011 00001010 18:56:11.914057 T00110000 Read-Data Relative modulation level: 0.00 18:56:12.075568 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:12.915078 T900E6400 Write-Data Maximum relative modulation level: 100.00 18:56:13.078014 B500E6400 Write-Ack Maximum relative modulation level: 100.00 18:56:13.911753 T80190000 Read-Data Boiler water temperature: 0.00 18:56:14.075132 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:14.911251 T10013000 Write-Data Control setpoint: 48.00 18:56:15.074399 BD0013000 Write-Ack Control setpoint: 48.00 18:56:15.911239 T00000300 Read-Data Status: 00000011 00000000 18:56:16.075006 BC000030A Read-Ack Status: 00000011 00001010 18:56:16.909481 T00110000 Read-Data Relative modulation level: 0.00 18:56:17.075439 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:17.909189 T10101400 Write-Data Room setpoint: 20.00 18:56:18.075261 BD0101400 Write-Ack Room setpoint: 20.00 18:56:18.908064 T80190000 Read-Data Boiler water temperature: 0.00 18:56:19.096627 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:19.907715 T10013000 Write-Data Control setpoint: 48.00 18:56:20.075024 BD0013000 Write-Ack Control setpoint: 48.00 18:56:20.906360 T00000300 Read-Data Status: 00000011 00000000 18:56:20.999295 BC000030A Read-Ack Status: 00000011 00001010 18:56:21.906362 T00110000 Read-Data Relative modulation level: 0.00 18:56:21.997923 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:22.908693 T90181400 Write-Data Room temperature: 20.00 18:56:23.047567 B50181400 Write-Ack Room temperature: 20.00 18:56:23.905002 T80190000 Read-Data Boiler water temperature: 0.00 18:56:23.998282 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:24.908342 T10013000 Write-Data Control setpoint: 48.00 18:56:25.014327 BD0013000 Write-Ack Control setpoint: 48.00 18:56:25.904487 T00000300 Read-Data Status: 00000011 00000000 18:56:25.995704 BC000030A Read-Ack Status: 00000011 00001010 18:56:26.902875 T00110000 Read-Data Relative modulation level: 0.00 18:56:26.995169 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:27.902510 T80310000 Read-Data Max CH setpoint boundaries: 0 0 18:56:27.994228 BC0314600 Read-Ack Max CH setpoint boundaries: 70 0 18:56:28.547731 SC: 18:56/3 18:56:28.903106 T80190000 Read-Data Boiler water temperature: 0.00 18:56:28.994381 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:29.901388 T10013000 Write-Data Control setpoint: 48.00 18:56:30.056367 BD0013000 Write-Ack Control setpoint: 48.00 18:56:30.900658 T00000300 Read-Data Status: 00000011 00000000 18:56:30.992936 BC000030A Read-Ack Status: 00000011 00001010 18:56:31.899627 T00110000 Read-Data Relative modulation level: 0.00 18:56:31.992984 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:32.903036 T1002010D Write-Data Master configuration: 00000001 13 18:56:33.008316 BD002010D Write-Ack Master configuration: 00000001 13 18:56:33.898221 T80190000 Read-Data Boiler water temperature: 0.00 18:56:33.990937 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:34.897790 T10013000 Write-Data Control setpoint: 48.00 18:56:35.021497 BD0013000 Write-Ack Control setpoint: 48.00 18:56:35.896235 T00000300 Read-Data Status: 00000011 00000000 18:56:35.989191 BC000030A Read-Ack Status: 00000011 00001010 18:56:36.915353 T00110000 Read-Data Relative modulation level: 0.00 18:56:36.988218 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:37.895505 T00030000 Read-Data Slave configuration: 00000000 0 18:56:37.987694 B4003410B Read-Ack Slave configuration: 01000001 11 18:56:38.895571 T80190000 Read-Data Boiler water temperature: 0.00 18:56:38.987601 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:39.894030 T10013000 Write-Data Control setpoint: 48.00 18:56:40.021263 BD0013000 Write-Ack Control setpoint: 48.00 18:56:40.913490 T00000300 Read-Data Status: 00000011 00000000 18:56:40.994135 BC000030A Read-Ack Status: 00000011 00001010 18:56:41.893330 T00110000 Read-Data Relative modulation level: 0.00 18:56:41.985115 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:42.891928 T00390000 Read-Data Max CH water setpoint: 0.00 18:56:42.985200 B40394600 Read-Ack Max CH water setpoint: 70.00 18:56:43.891560 T80190000 Read-Data Boiler water temperature: 0.00 18:56:43.984185 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:44.891168 T10013000 Write-Data Control setpoint: 48.00 18:56:45.060922 BD0013000 Write-Ack Control setpoint: 48.00 18:56:45.889944 T00000300 Read-Data Status: 00000011 00000000 18:56:45.982494 BC000030A Read-Ack Status: 00000011 00001010 18:56:46.888564 T00110000 Read-Data Relative modulation level: 0.00 18:56:46.981227 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:47.891128 T001B0000 Read-Data Outside temperature: 0.00 18:56:47.980597 B601B0000 Data-Inv Outside temperature: 0.00 18:56:48.887051 T80190000 Read-Data Boiler water temperature: 0.00 18:56:48.987984 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:49.886968 T10013000 Write-Data Control setpoint: 48.00 18:56:50.037845 BD0013000 Write-Ack Control setpoint: 48.00 18:56:50.886701 T00000300 Read-Data Status: 00000011 00000000 18:56:50.993895 BC000030A Read-Ack Status: 00000011 00001010 18:56:51.884600 T00110000 Read-Data Relative modulation level: 0.00 18:56:51.978049 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:52.883546 T00060000 Read-Data Remote parameter flags: 00000000 00000000 18:56:52.980091 BC0060303 Read-Ack Remote parameter flags: 00000011 00000011 18:56:53.883790 T80190000 Read-Data Boiler water temperature: 0.00 18:56:53.981398 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:54.882620 T10013000 Write-Data Control setpoint: 48.00 18:56:55.027873 BD0013000 Write-Ack Control setpoint: 48.00 18:56:55.881858 T00000300 Read-Data Status: 00000011 00000000 18:56:55.974867 BC000030A Read-Ack Status: 00000011 00001010 18:56:56.880704 T00110000 Read-Data Relative modulation level: 0.00 18:56:56.996765 BC0110000 Read-Ack Relative modulation level: 0.00 18:56:57.880919 T907E010B Write-Data Master product version: 1 11 18:56:57.901061 R807A0000 Read-Data DHW pump/valve operation hours: 0 18:56:58.046365 B407A21E4 Read-Ack DHW pump/valve operation hours: 8676 18:56:58.061423 AF07E010B Unk-DataId Master product version: 1 11 18:56:58.879583 T80190000 Read-Data Boiler water temperature: 0.00 18:56:58.974484 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:56:59.879157 T10013000 Write-Data Control setpoint: 48.00 18:57:00.000883 BD0013000 Write-Ack Control setpoint: 48.00 18:57:00.877846 T00000300 Read-Data Status: 00000011 00000000 18:57:00.975190 BC000030A Read-Ack Status: 00000011 00001010 18:57:01.877733 T00110000 Read-Data Relative modulation level: 0.00 18:57:01.974246 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:02.877098 T807F0000 Read-Data Slave product version: 0 0 18:57:02.973825 BC07F1401 Read-Ack Slave product version: 20 1 18:57:03.876180 T80190000 Read-Data Boiler water temperature: 0.00 18:57:03.974218 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:04.883882 T10013000 Write-Data Control setpoint: 48.00 18:57:05.046327 BD0013000 Write-Ack Control setpoint: 48.00 18:57:05.876470 T00000300 Read-Data Status: 00000011 00000000 18:57:05.974974 BC000030A Read-Ack Status: 00000011 00001010 18:57:06.874516 T00110000 Read-Data Relative modulation level: 0.00 18:57:06.974457 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:07.873693 T80380000 Read-Data DHW setpoint: 0.00 18:57:07.973829 B40383C00 Read-Ack DHW setpoint: 60.00 18:57:08.873964 T80190000 Read-Data Boiler water temperature: 0.00 18:57:08.977290 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:09.877136 T10013000 Write-Data Control setpoint: 48.00 18:57:10.029003 BD0013000 Write-Ack Control setpoint: 48.00 18:57:10.871838 T00000300 Read-Data Status: 00000011 00000000 18:57:10.974256 BC000030A Read-Ack Status: 00000011 00001010 18:57:11.876303 T00110000 Read-Data Relative modulation level: 0.00 18:57:11.973316 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:12.870033 T00300000 Read-Data DHW setpoint boundaries: 0 0 18:57:12.974546 BC0304128 Read-Ack DHW setpoint boundaries: 65 40 18:57:13.869633 T80190000 Read-Data Boiler water temperature: 0.00 18:57:13.975033 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:14.868525 T10013000 Write-Data Control setpoint: 48.00 18:57:15.018808 BD0013000 Write-Ack Control setpoint: 48.00 18:57:15.886327 T00000300 Read-Data Status: 00000011 00000000 18:57:15.975096 BC000030A Read-Ack Status: 00000011 00001010 18:57:16.867111 T00110000 Read-Data Relative modulation level: 0.00 18:57:16.975308 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:17.866478 T00120000 Read-Data CH water pressure: 0.00 18:57:17.974840 B40120200 Read-Ack CH water pressure: 2.00 18:57:18.864864 T80190000 Read-Data Boiler water temperature: 0.00 18:57:18.974347 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:19.866219 T10013000 Write-Data Control setpoint: 48.00 18:57:20.022062 BD0013000 Write-Ack Control setpoint: 48.00 18:57:20.866145 T00000300 Read-Data Status: 00000011 00000000 18:57:20.990094 BC000030A Read-Ack Status: 00000011 00001010 18:57:21.864424 T00110000 Read-Data Relative modulation level: 0.00 18:57:21.973985 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:22.863559 T80130000 Read-Data DHW flow rate: 0.00 18:57:22.879909 R007B0000 Read-Data DHW burner operation hours: 0 18:57:22.978795 BC07B0053 Read-Ack DHW burner operation hours: 83 18:57:22.988331 A70130000 Unk-DataId DHW flow rate: 0.00 18:57:23.862142 T80190000 Read-Data Boiler water temperature: 0.00 18:57:23.975105 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:24.862225 T10013000 Write-Data Control setpoint: 48.00 18:57:25.014696 BD0013000 Write-Ack Control setpoint: 48.00 18:57:25.860904 T00000300 Read-Data Status: 00000011 00000000 18:57:25.974259 BC000030A Read-Ack Status: 00000011 00001010 18:57:26.859277 T00110000 Read-Data Relative modulation level: 0.00 18:57:26.980212 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:27.859306 T801A0000 Read-Data DHW temperature: 0.00 18:57:27.974476 BE01A0000 Data-Inv DHW temperature: 0.00 18:57:28.611151 SC: 18:57/3 18:57:28.858700 T80190000 Read-Data Boiler water temperature: 0.00 18:57:28.974232 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:29.858652 T10013000 Write-Data Control setpoint: 48.00 18:57:30.004752 BD0013000 Write-Ack Control setpoint: 48.00 18:57:30.858149 T00000300 Read-Data Status: 00000011 00000000 18:57:30.989346 BC000030A Read-Ack Status: 00000011 00001010 18:57:31.855765 T00110000 Read-Data Relative modulation level: 0.00 18:57:31.974587 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:32.858456 T801C0000 Read-Data Return water temperature: 0.00 18:57:32.974352 BC01C211C Read-Ack Return water temperature: 33.11 18:57:33.855148 T80190000 Read-Data Boiler water temperature: 0.00 18:57:33.975801 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:34.855223 T10013000 Write-Data Control setpoint: 48.00 18:57:35.010110 BD0013000 Write-Ack Control setpoint: 48.00 18:57:35.853093 T00000300 Read-Data Status: 00000011 00000000 18:57:35.974570 BC000030A Read-Ack Status: 00000011 00001010 18:57:36.851245 T00110000 Read-Data Relative modulation level: 0.00 18:57:36.974397 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:37.852284 T000A0000 Read-Data Number of TSPs: 0 18:57:37.867193 R00740000 Read-Data Burner starts: 0 18:57:37.974459 B40742713 Read-Ack Burner starts: 10003 18:57:37.989913 AF00A0000 Unk-DataId Number of TSPs: 0 18:57:38.851523 T80190000 Read-Data Boiler water temperature: 0.00 18:57:38.988902 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:39.850003 T10013000 Write-Data Control setpoint: 48.00 18:57:39.987781 BD0013000 Write-Ack Control setpoint: 48.00 18:57:40.848439 T00000300 Read-Data Status: 00000011 00000000 18:57:40.976758 BC000030A Read-Ack Status: 00000011 00001010 18:57:41.848650 T00110000 Read-Data Relative modulation level: 0.00 18:57:41.974027 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:42.848536 T000C0000 Read-Data Size of fault buffer: 0 18:57:42.866018 R80750000 Read-Data CH pump starts: 0 18:57:42.988643 B407520D5 Read-Ack CH pump starts: 8405 18:57:43.001254 AF00C0000 Unk-DataId Size of fault buffer: 0 18:57:43.847207 T80190000 Read-Data Boiler water temperature: 0.00 18:57:43.973839 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:44.845721 T10013000 Write-Data Control setpoint: 48.00 18:57:44.975026 BD0013000 Write-Ack Control setpoint: 48.00 18:57:45.845306 T00000300 Read-Data Status: 00000011 00000000 18:57:45.973423 BC000030A Read-Ack Status: 00000011 00001010 18:57:46.849092 T00110000 Read-Data Relative modulation level: 0.00 18:57:46.991638 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:47.844645 T00050000 Read-Data Application-specific flags: 00000000 0 18:57:47.974714 BC00500FF Read-Ack Application-specific flags: 00000000 255 18:57:48.843310 T80190000 Read-Data Boiler water temperature: 0.00 18:57:48.974583 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:49.845330 T10013000 Write-Data Control setpoint: 48.00 18:57:49.990768 BD0013000 Write-Ack Control setpoint: 48.00 18:57:50.842218 T00000300 Read-Data Status: 00000011 00000000 18:57:50.992663 BC000030A Read-Ack Status: 00000011 00001010 18:57:51.841243 T00110000 Read-Data Relative modulation level: 0.00 18:57:51.974066 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:52.840340 T00090000 Read-Data Remote override room setpoint: 0.00 18:57:52.856561 R80760000 Read-Data DHW pump/valve starts: 0 18:57:52.975051 B4076172E Read-Ack DHW pump/valve starts: 5934 18:57:52.991367 AC0090000 Read-Ack Remote override room setpoint: 0.00 18:57:53.855229 T80190000 Read-Data Boiler water temperature: 0.00 18:57:53.975115 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:54.839257 T10013000 Write-Data Control setpoint: 48.00 18:57:54.974615 BD0013000 Write-Ack Control setpoint: 48.00 18:57:55.837891 T00000300 Read-Data Status: 00000011 00000000 18:57:55.974525 BC000030A Read-Ack Status: 00000011 00001010 18:57:56.836966 T00110000 Read-Data Relative modulation level: 0.00 18:57:56.974706 BC0110000 Read-Ack Relative modulation level: 0.00 18:57:57.835961 T900E6400 Write-Data Maximum relative modulation level: 100.00 18:57:57.975206 B500E6400 Write-Ack Maximum relative modulation level: 100.00 18:57:58.835559 T80190000 Read-Data Boiler water temperature: 0.00 18:57:58.974044 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:57:59.836641 T10013000 Write-Data Control setpoint: 48.00 18:57:59.974962 BD0013000 Write-Ack Control setpoint: 48.00 18:58:00.833129 T00000300 Read-Data Status: 00000011 00000000 18:58:00.974748 BC000030A Read-Ack Status: 00000011 00001010 18:58:01.833215 T00110000 Read-Data Relative modulation level: 0.00 18:58:01.973926 BC0110000 Read-Ack Relative modulation level: 0.00 18:58:02.831703 T10101400 Write-Data Room setpoint: 20.00 18:58:02.980533 BD0101400 Write-Ack Room setpoint: 20.00 18:58:03.831664 T80190000 Read-Data Boiler water temperature: 0.00 18:58:03.977034 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:58:04.830405 T10013000 Write-Data Control setpoint: 48.00 18:58:04.975116 BD0013000 Write-Ack Control setpoint: 48.00 18:58:05.829807 T00000300 Read-Data Status: 00000011 00000000 18:58:05.974455 BC000030A Read-Ack Status: 00000011 00001010 18:58:06.835324 T00110000 Read-Data Relative modulation level: 0.00 18:58:06.974604 BC0110000 Read-Ack Relative modulation level: 0.00 18:58:07.829190 T90181400 Write-Data Room temperature: 20.00 18:58:07.987885 B50181400 Write-Ack Room temperature: 20.00 18:58:08.827229 T80190000 Read-Data Boiler water temperature: 0.00 18:58:08.974662 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:58:09.826749 T10013000 Write-Data Control setpoint: 48.00 18:58:09.986169 BD0013000 Write-Ack Control setpoint: 48.00 18:58:10.826265 T00000300 Read-Data Status: 00000011 00000000 18:58:10.974167 BC000030A Read-Ack Status: 00000011 00001010 18:58:11.825706 T00110000 Read-Data Relative modulation level: 0.00 18:58:11.974312 BC0110000 Read-Ack Relative modulation level: 0.00 18:58:12.825042 T80310000 Read-Data Max CH setpoint boundaries: 0 0 18:58:12.974503 BC0314600 Read-Ack Max CH setpoint boundaries: 70 0 18:58:13.824900 T80190000 Read-Data Boiler water temperature: 0.00 18:58:13.976035 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:58:14.823407 T10013000 Write-Data Control setpoint: 48.00 18:58:14.976644 BD0013000 Write-Ack Control setpoint: 48.00 18:58:15.822704 T00000300 Read-Data Status: 00000011 00000000 18:58:15.973318 BC000030A Read-Ack Status: 00000011 00001010 18:58:16.826126 T00110000 Read-Data Relative modulation level: 0.00 18:58:16.974254 BC0110000 Read-Ack Relative modulation level: 0.00 18:58:17.820955 T1002010D Write-Data Master configuration: 00000001 13 18:58:17.978108 BD002010D Write-Ack Master configuration: 00000001 13 18:58:18.821177 T80190000 Read-Data Boiler water temperature: 0.00 18:58:18.975334 BC0193D66 Read-Ack Boiler water temperature: 61.40 18:58:19.819311 T10013000 Write-Data Control setpoint: 48.00 18:58:19.973815 BD0013000 Write-Ack Control setpoint: 48.00 18:58:20.837976 T00000300 Read-Data Status: 00000011 00000000 18:58:20.987782 B40000302 Read-Ack Status: 00000011 00000010 18:58:21.819105 T00000300 Read-Data Status: 00000011 00000000 18:58:22.103500 B40000302 Read-Ack Status: 00000011 00000010 18:58:23.063771 T00110000 Read-Data Relative modulation level: 0.00 18:58:23.078719 BC0110000 Read-Ack Relative modulation level: 0.00 18:58:23.826214 T00000300 Read-Data Status: 00000011 00000000 18:58:23.973908 B40000302 Read-Ack Status: 00000011 00000010 18:58:24.815863 T100E0000 Write-Data Maximum relative modulation level: 0.00 18:58:24.988318 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 18:58:25.815282 T00030000 Read-Data Slave configuration: 00000000 0 18:58:25.974160 B4003410B Read-Ack Slave configuration: 01000001 11