Notifications
You must be signed in to change notification settings - Fork 22
/
Copy pathConfigure_HEV_Simulation.m
49 lines (43 loc) · 1.88 KB
/
Configure_HEV_Simulation.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
% Copyright 2011-2024 The MathWorks, Inc.
%disp('CONFIGURING MODEL...');
HEV_Solver_Selection = 'ode15s';
%HEV_Solver_Selection = 'ode23t';
%evalin('base',['disp([''Mode Logic TS = '' num2str(HEV_Param.Control.Mode_Logic_TS)])']);
%disp('Checking blocks...');
expModel = bdroot;
HEV_Model_DLevel_blk = [expModel '/Electrical'];
DetailLevel = get_param(HEV_Model_DLevel_blk,'OverrideUsingVariant');
f = Simulink.FindOptions('FollowLinks',1,'LookUnderMasks','all',...
'MatchFilter',@Simulink.match.activeVariants,'SearchDepth',3);
HEV_Model_BattModel_blk = Simulink.findBlocks(bdroot,'Name','Battery',f);
BattModel = get_param(HEV_Model_BattModel_blk,'OverrideUsingVariant');
if (strcmp(DetailLevel,'Mean_Value'))
decimation = 500;
assignin('base','Ts',60e-6)
assignin('base','decimation',decimation)
if (strcmp(BattModel,'Predefined'))
set_param(expModel,'Solver',HEV_Solver_Selection,'MaxStep','1e-3')
else
set_param(expModel,'Solver',HEV_Solver_Selection,'MaxStep','1e-3')
end
set_param([expModel,'/powergui'],'SimulationMode','Discrete');
elseif (strcmp(DetailLevel,'Detailed'))
decimation = 5000;
% decimation = 50; % FOR POWER QUALITY
% decimation = 1; % FOR PLOTS
assignin('base','Ts',2e-6)
assignin('base','decimation',decimation)
if (strcmp(BattModel,'Predefined'))
set_param(expModel,'Solver',HEV_Solver_Selection,'MaxStep','1e-3')
%set_param(expModel,'Solver','ode23tb','MaxStep','1e-3')
else
set_param(expModel,'Solver',HEV_Solver_Selection,'MaxStep','1e-3')
end
set_param([expModel,'/powergui'],'SimulationMode','Discrete');
elseif strcmp(DetailLevel,'System_Level')
decimation = 1;
assignin('base','Ts',[])
assignin('base','decimation',decimation)
set_param(expModel,'Solver',HEV_Solver_Selection,'MaxStep','auto')
set_param([expModel,'/powergui'],'SimulationMode','Continuous');
end