Connecting to a running HPX application works only once #567

Closed
hkaiser opened this issue Oct 10, 2012 · 2 comments
Closed

Connecting to a running HPX application works only once #567

hkaiser opened this issue Oct 10, 2012 · 2 comments
Assignees
Milestone

Comments

@hkaiser
Copy link
Member

hkaiser commented Oct 10, 2012

Using the runflag runtimemode_connect (as used in the heartbeat example) is functional only once. Reconnecting a second time gives errors caused by lingering sockets.

@ghost ghost assigned hkaiser Oct 10, 2012
@sithhell
Copy link
Member

This still fails on linux:
https://gist.github.com/3872122
The exception is thrown when trying to connect a second time

@sithhell sithhell reopened this Oct 11, 2012
@sithhell
Copy link
Member

This was a false report. The connecting application was closed with ctrl-c. The console couldn't possible detect this. Closing again.