Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Axes do not respect the auto delta ET and delta BT check boxes when running designer #1062

Closed
wbj828 opened this issue Dec 25, 2022 · 1 comment

Comments

@wbj828
Copy link

wbj828 commented Dec 25, 2022

Describe the bug
When Tools | designer is checked, you may have a shortened delta scale even if auto BT and auto ET are checked in Config / Axes. This makes it impossible to see the entire Delta BT curve.

To Reproduce

  1. Open Artisan and click on Reset to clear the current roast.
  2. Go to Config | Axes and turn on Auto ET and Auto BT in the Delta Axis block.
  3. Start Designer by clicking Tools | Designer.

Expected behavior
The designer should have set the delta axis to a reasonable value…but in my case the min value was 0 and the max value was not shown. The Delta BT curve is not visible other than the extreme first part. (Axes max value set to 1)

Screenshots
If this is not clear…let me know and I will update screenshots.

Setup (please complete the following information):

  • Artisan Version [e.g. v2.8.2]:
  • Platform (MacOs 13.1):

Additional context
There is also some weirdness where the max values will be reset if the min values are less than 0 and the auto boxes are checked.

Note: If you set the delta BT and ET axes to “manual” by unchecking the auto checkboxes you can set reasonable values for the max and min delta axis value…this works fine.

@wbj828
Copy link
Author

wbj828 commented Dec 25, 2022

Image 12-25-22 at 1 07 PM

Here is screenshot of what I am seeing when auto axes is checked and in designer. Note the Delta BT curve is only partially visible.

MAKOMO added a commit that referenced this issue Dec 26, 2022
…ssue #1062)

- don't deactivate auto DeltaET/DeltaBT axis without changing the delta max limit (resolves Issue #1062)
- fixes missed pick in Designer after string from a profile
@MAKOMO MAKOMO closed this as completed Dec 26, 2022
@MAKOMO MAKOMO added this to the v2.10.0 milestone Dec 26, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Development

No branches or pull requests

2 participants