Loadpoint Settings: Current limit options should be limited based on loadpoint configuration #13355

Open
hyperbart opened this issue Apr 9, 2024 · 5 comments
Assignees
Labels
backlog Things to do later enhancement New feature or request

Comments

@hyperbart
Copy link
Contributor

Describe the bug

EVCC with Alfen Pro Line 22KW (32A)
When you configure EVCC and set a maximum amps as below:

image

The GUI does not limit the list of amps you can set (so you can get wrong expectations).
GUI should limit the list of amps to the max amps configured in GUI/YAML.

image

Steps to reproduce

EVCC with Alfen Pro Line 22KW (32A)
When you configure EVCC and set a maximum amps as below:

image

The GUI does not limit the list of amps you can set (so you can get wrong expectations).
GUI should limit the list of amps to the max amps.

image

Configuration details

loadpoints:
- title: Voortuin # display name for UI
  charger: ChargingPointAlfen # Wallbox Referenz
  mode: minpv # charge mode (off, now, minpv, pv)
  phases: 0 
  mincurrent: 6 
  maxcurrent: 22
  guardduration: 2m
  enable:
    threshold: 0
    delay: 1m
  disable:
    threshold: 0 # maximum import power (W)
    delay: 3m

Log details

N/A

What type of operating system are you running?

Docker container

Version

125

@mdkeil
Copy link
Contributor

mdkeil commented Apr 9, 2024

mincurrent, maxcurrent and phases are depricated parameters in yaml-config and should be configured via UI only.

guardduration is obsolete too.

@hyperbart
Copy link
Contributor Author

mincurrent, maxcurrent and phases are depricated parameters in yaml-config and should be configured via UI only.

guardduration is obsolete too.

Ok, valid feedback but not relevant for this point I think, because regardless of where you configure that limit (be that via YML or WebGUI) the list can/should still be limited according to config in my opinion.

@mdkeil
Copy link
Contributor

mdkeil commented Apr 9, 2024

ah ok.. your opinion is (after initial configuration) that the shown GUI-settings are limited to the real device parameter limits.

@VolkerK62
Copy link
Contributor

the list in the (WebGUI) loadpoint settings is the replacement of the parameter mincurrent, maxcurrent of the yaml.

@andig andig added the question Rather clarification than issue label Apr 9, 2024
@naltatis
Copy link
Member

This is a topic we already talked about a couple of times. Currently, the loadpoint only has one(!) set of min-/maxcurrent limits. Previously it was defined in the evcc.yaml, now it's in the loadpoints setting screen. What you're looking for is to have two sets:

  1. installation level: you or an installer defines min/max while installation/configuration based on the device's capability and fuse protection.
  2. user level: ability to adjust min/max current on a daily basis for specify demands (manual peak shaving, manual optimization, ...). Maybe also mode specific (later). Here, it should be only possible to specify values that are inside the boundaries defined in 1.

With Config UI #12958 we introduce min/max current settings in the loadpoint setup/configuration interface. When we are done with that, we can introduce the second set of limits in core and limit the Main UI settings accordingly.

We already have (planned) two distinct endpoints for changing the limits, but right now, both modify the same "installation level" value.

PUT /api/config/loadpoints/1 {maxcurrent: 16} # used in Config UI (see PR)
POST /api/loadpoints/1/maxcurrent/16 # used in Main UI

In short, yes, we should implement this once #12958 is live.

@naltatis naltatis added enhancement New feature or request backlog Things to do later and removed question Rather clarification than issue labels Apr 12, 2024
@naltatis naltatis changed the title [GUI] Amps dropdown list should be limited based on underlying configuration of loadpoint Loadpoint Settings: Current limit options should be limited based on loadpoint configuration Apr 12, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment